首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Curcumin, a derivative of the plant Curcuma longa, is used extensively in the food industry. It is a major component of curry powder, and research has shown that curcumin may prevent cancer and other chronic diseases. We have developed a robust automated analytical method for the determination of curcumin in plasma and urine. The method involves extracting the curcumin from 0.2 ml sample volume with ethyl acetate/methanol organic solvents, and use of an internal standard, beta-17-estradiol acetate. Analysis utilizes a reversed-phase C(18) column and UV detection at 262 nm. Performance characteristics have been assessed. The assay is linear from 0.2 to 7.0 microgram/ml. The coefficient of variation for intra- and inter-day assays is <7.5%. The average recovery of curcumin from plasma and urine is greater than 96%. The data presented in this report demonstrate that the method provides rapid, sensitive, precise and accurate measurements of curcumin concentrations in plasma and urine.  相似文献   

2.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

3.
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma.  相似文献   

4.
A SPE-HPLC method was developed and validated for the simultaneous determination of flavonols, isoquercitrin (1), hibifolin (2), myricetin (3), quercetin-3'-O-d-glucoside (4) and quercetin (5) in rat plasma and urine after oral administration of the total flavonoids from Abelmoschus manihot (TFA). The astragalin (6) and kaempferol (7) were used as internal standards (IS). Plasma and urine samples were pretreated by solid-phase extraction using Winchem C(18) reversed-phase cartridges. Analysis of the plasma and urinary extract was performed on YMC-Pack ODS-A C(18) and Thermo ODS-2HYEPRSIL C(18) reversed-phase column, respectively and a mobile phase of acetonitrile-0.1% phosphoric acid was employed. HPLC analysis was conducted with different elution gradients. The flow rate was 1.0 mL/min and the detection wavelength was set at 370 nm. Calibration ranges in plasma for flavonols 2-5 were at 0.011-2.220, 0.014-2.856, 0.022-4.320, and 0.028-5.600 microg/mL, respectively. In urine calibration ranges for flavonols 1, 2, 4 and 5 were at 2.00-16.00, 8.56-102.72, 2.70-21.60, and 3.00-24.00 microg/mL, respectively. The RSD of intra- and inter-day was less than 5.40% and 4.89% in plasma, and less than 3.96% and 6.85% in urine for all the analyses. A preliminary experiment to investigate the plasma concentration and urinary excretion of the flavonols after oral administration of TFA to rats demonstrated that the present method was suitable for determining the flavonols in rat plasma and urine.  相似文献   

5.
A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5-100 microg/mL and 0.25-50 microg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 microg/mL. Validation data for accuracy and precision were CV<2.48 and 8.25%, accuracy in the range 98.1-104.2% and 102.2-108.4%, respectively, for intra and inter-day.  相似文献   

6.
An isocratic and sensitive HPLC assay was developed allowing the determination of the new anticancer drug nilotinib (AMN107) in human plasma, urine, culture medium and cell samples. After protein precipitation with perchloric acid, AMN107 underwent an online enrichment using a Zirchrom-PBD precolumn, was separated on a Macherey-Nagel C18-HD column and finally quantified by UV-detection at 258 nm. The total run time is 25 min. The assay demonstrates linearity within a concentration range of 0.005-5.0 microg/ml in plasma (r(2)=0.9998) and 0.1-10.0 microg/ml in urine (r(2)=0.9913). The intra-day precision expressed as coefficients of variation ranged depending on the spiked concentration between 1.27-9.23% in plasma and 1.77-3.29% in urine, respectively. The coefficients of variation of inter-day precision was lower than 10%. Limit of detection was 0.002 microg/ml in plasma and 0.01 microg/ml in urine. The described method is stable, simple, economic and is routinely used for in vivo and in vitro pharmacokinetic studies of AMN107.  相似文献   

7.
The paper describes a method for the sensitive and selective determination of zearalenone and its metabolites in urine, plasma and faeces of horses by high performance liquid chromatography and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS). While only one step sample clean-up by an immunoaffinity column (IAC) was sufficient for plasma samples, urine and faeces samples had to be prepared by a combination of a solid-phase extraction (SPE) and an immunoaffinity column. The method allows the simultaneous determination of zearalenone and all of its metabolites; alpha-zearalenol, beta-zearalenol, alpha-zearalanol, beta-zearalanol and zearalanone. Dideuterated zearalanone was used as internal standard for quantification and the study of the matrix effect. Recovery rates between 56 and slightly above 100% were achieved in urine samples, and more than 80% in plasma and faeces samples. The limits of detection ranged from 0.1-0.5 microg/l or microg/kg, the limits of quantification from 0.5-1.0 microg/l or microg/kg. The practical use of the method is demonstrated by the analysis of spiked and naturally contaminated urine, plasma and faeces of horses.  相似文献   

8.
A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%. A linear dynamic range of 100-10,000 ng/mL for both theophylline and etofylline was established. This HPLC method was validated with between-batch precision of 2.2-6.0 and 1.4-3.7% for theophylline and etofylline, respectively. The between-batch accuracy was 94.3-98.0 and 95.4-98.2%, respectively. Stability of theophylline and etofylline in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and rugged enough to be used in pharmacokinetic studies.  相似文献   

9.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

10.
A simple and sensitive high-performance liquid chromatography (HPLC) method utilizing ultraviolet (UV) detection was developed for the determination of inosine and hypoxanthine in human plasma. For component separation, a monolithic C(18) column at a flow rate of 1.0 mL/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water pH 2.2, v/v) and methanol gradient was used. The method employed a one-step sample preparation utilizing centrifugal filtration with high component recoveries (approximately 98%) from plasma, which eliminated the need of an internal standard. The method demonstrated excellent linearity (0.25-5 microg/mL, R>0.9990) for both inosine and hypoxanthine with detection limits of 100 ng/mL. This simple and cost effective method was utilized to evaluate potential endogenous plasma biomarker(s), which may aid hospital emergency personnel in the early detection of acute cardiac ischemia in patients presenting with non-traumatic chest pain.  相似文献   

11.
Indomethacin (IND) is the drug of choice for the closure of a patent ductus arteriosus (PDA) in neonates. This paper describes a simple, sensitive, accurate and precise microscale HPLC method suitable for the analysis of IND in plasma of premature neonates. Samples were prepared by plasma protein precipitation with acetonitrile containing the methyl ester of IND as the internal standard (IS). Chromatography was performed on a Hypersil C(18) column. The mobile phase of methanol, water and orthophosphoric acid (70:29.5:0.5, v/v, respectively), was delivered at 1.5 mL/min and monitored at 270 nm. IND and the IS were eluted at 2.9 and 4.3 min, respectively. Calibrations were linear (r>0.999) from 25 to 2500 microg/L. The inter- and intra-day assay imprecision was less than 4.3 % at 400-2000 microg/L, and less than 22.1% at 35 microg/L. Inaccuracy ranged from -6.0% to +1.0% from 35 to 2000 microg/L. The absolute recovery of IND over this range was 93.0-113.3%. The IS was stable for at least 36 h when added to plasma at ambient temperature. This method is suitable for pharmacokinetic studies of IND and has potential for monitoring therapy in infants with PDA when a target therapeutic range for IND has been validated.  相似文献   

12.
A simple and rapid HPLC method that includes ultrafiltration to remove plasma and peritoneal fluid protein was developed to determine doripenem concentrations in human plasma and peritoneal fluid. Doripenem was stabilized by immediate mixing of the plasma or peritoneal fluid with 1M 3-morpholinopropanesulfonic acid buffer (pH 7.0) (1:1). Doripenem and an internal standard were detected by measuring their ultraviolet absorbance at 300 nm. The calibration curves for doripenem in human plasma and peritoneal fluid were linear from 0.05 to 100 microg/mL. For plasma, both the intra- and the interday precision were less than 3.41% (CV), and the accuracy was between 97.4 and 101.7% above 0.05 microg/mL. For peritoneal fluid, the intra- and the interday precision were less than 2.98% (CV), and the accuracy was between 94.4 and 103.9% above 0.05 microg/mL. The limit of detection was 0.02 microg/mL in both plasma and peritoneal fluid. The assay has been applied to the therapeutic drug monitoring of doripenem in both plasma and peritoneal fluid.  相似文献   

13.
Gadocoletate ion is a new paramagnetic intravascular contrast agent for magnetic resonance imaging (MRI). An high-performance liquid chromatographic method for assaying Gadocoletate ion in human plasma, urine and faecal samples is described. The analysis is based on the reversed-phase chromatographic separation of Gadocoletate ion from the endogenous components of the biological matrices and its detection during elution by ultraviolet light absorption at 200 nm. The selectivity of the method was satisfactory. The mean absolute recovery during the analytical sample preparation was greater than 87%. The precision, expressed as coefficient of variation (CV%) ranged from 0.29 to 5.90% and the accuracy, expressed as mean relative error (R.E.%) of the analytical method ranged from -3.7 to +7.1%. The detection limit in plasma and urine was 2.01 and 10.0 microg/mL (0.00203 and 0.0101 micromol/mL), respectively. The detection limit in homogenized faecal samples was 17.7 microg/g (0.0179 micromol/g). Stability studies were performed in human plasma and urine samples during the analytical cycle. Gadocoletate ion was shown to be stable in human plasma and in human urine when stored at about +4 degrees C for up 24 h, and after three freeze-thaw cycles. In addition, it was shown to be stable in samples of processed plasma and in diluted urine at about +4 degrees C for 48 h, and at room temperature for at least 24 h. As regards the long-term stability of Gadocoletate ion, the results of dedicated studies showed that Gadocoletate ion is stable in human plasma samples when stored at +4 degrees C for up to 30 days and at -80 degrees C for up to 90 days. Gadocoletate ion is stable in samples of human urine when stored at +4 degrees C for up to 30 days, and when stored at -20 degrees C and at -80 degrees C for up to 90 days. The method has been successfully validated in human plasma, urine and faeces and it has been shown to be precise, accurate and reliable.  相似文献   

14.
A HPLC method was developed for determination of cimetidine in human plasma and urine. Plasma samples were alkalinized followed by liquid extraction with water-saturated ethyl acetate then evaporated under nitrogen. The extracts were reconstituted in mobile phase and injected onto a C(18) reversed-phase column; UV detection was set at 228 nm. Urine samples were diluted with an internal standard/mobile phase mixture (1:9) prior to injection. The lower limit of quantification in plasma and urine were 100 ng/ml and 10 microg/ml, respectively; intra- and inter-day coefficients of variation were 相似文献   

15.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

16.
We describe here a simple, precise, and highly sensitive method for the simultaneous determination of methamphetamine (MA) and amphetamine (AM) in urine using a high performance liquid chromatography (HPLC) column-switching method. A PK-2A (Shodex) column was used for extraction and deproteinization, and a CAPCELL PAK SCX semi-micro, polymer-coated cation-exchange column was employed for separation. The urine sample was mixed with an equal volume of borate buffer (0.1M, pH 9.4), and then 100 microl of the mixture was injected into the HPLC column. The column was switched for 6 min, and then 10 min later detection was performed at 210 nm. Recovery yields of the MA and AM spiked in the urine were 93.0-100.4% with a coefficient of variation of less than 1%. The calibration curves of MA and AM were in the range of 0.1-10 microg/ml with good linearity (r(2)=0.999), with the limit of qualification being 0.005 microg/ml. This method of using HPLC with column-switching can be used for both qualification and quantification of MA and its metabolite, AM, in urine, especially in forensic cases.  相似文献   

17.
A simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of epimedin C in rat plasma and applied to a pharmacokinetic study in rats after administration of Herba Epimedii extract. After addition of carbamazepine as an internal standard plasma samples were extracted with ethyl acetate. HPLC analysis of the extracts was performed on a Hypersil ODS2 analytical column using acetonitrile -0.4% acetic acid (25:75, v/v) as the mobile phase. The UV detector was set at 260 nm. The standard curve was linear over the range 0.05-4.0 microg/mL. The lower limit of quantification was 0.05 microg/mL. The HPLC method developed could be easily applied to the determination and pharmacokinetic study of epimedin C in rat plasma after giving the animals Herba Epimedii extract.  相似文献   

18.
A simple, rapid, sensitive and reliable high performance liquid chromatography (HPLC) method for the determination of the anti-ulcer drug sofalcone in human plasma was developed. Plasma was extracted with ethyl acetate under acidic conditions and sofalcone was determined by HPLC using a C18 column and (methanol-0.1% formic acid aqueous 80:20) mobile phase. The linear calibration curves of sofalcone in human plasma were obtained over the concentration range of 0.01-5.0 microg/ml. The lower limit of quantitation (LLOQ) was 10 ng/ml in human plasma. The precision measured for plasma was within 15%. Extraction recovery was over 85% in blood. The method was successfully applied to the identification and quantification of sofalcone in pharmacokinetic studies.  相似文献   

19.
A simple, rapid, and precise high-performance liquid chromatography (HPLC) method using ultrafiltration to remove plasma protein was developed to determine meropenem concentrations in human plasma in a clinical setting. Plasma was separated by centrifugation at 4 degrees C from blood collected in heparinized vacuum tubes, and meropenem was stabilized by immediately mixing the plasma with 1M 3-morpholinopropanesulfonic acid buffer (pH 7.0) (1:1). Ultrafiltration was used for plasma deproteinization. Meropenem was detected by ultraviolet absorbance at 300 nm with no interfering plasma peak. The calibration curve of meropenem in human plasma was linear from 0.05 to 100 microg/mL. Intraday and interday precision was less than 7.17% (CV), and accuracy was between 97.7% and 106.3% over 0.05 microg/mL. The limit of detection was 0.01 microg/mL. The assay has been clinically applied to a real-time therapeutic drug monitoring in pediatric patients and pharmacokinetic studies.  相似文献   

20.
A HPLC method for determination of trans-resveratrol concentrations in rat plasma was developed. Plasma samples were treated with acetonitrile to deposit proteins. The analysis used a Hypersil ODS(2) C(18) column (5 microm, 4.6 mm x 250 mm) and methanol/distilled water as the mobile phase (flow-rate=1 mL/min). The UV detection wavelength was 303 nm, and chlorzoxazone was used as the internal standard. The calibration curve was linear over the range of 0.02-40 microg/mL with a correlation coefficient of 0.9997. This concentration range corresponds well with the plasma concentrations of resveratrol in pharmacokinetic studies. There was 98.7%, 91.3% and 84.4% recovery from 0.02, 0.4 and 40 microg/mL plasma samples respectively. The R.S.D. of intra- and inter-day assay variations were all less than 12%. This HPLC assay is a quick, precise and reliable method for the analysis of resveratrol in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号