首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 890 毫秒
1.
A technique has been developed to record 18O2 dilution curves of an organ in vivo by use of 51Cr-labeled erythrocytes as a reference tracer. The technique employs anaerobic sampling of venous outflow following an intraarterial injection of tracer-laden blood and off-line determination of [18O2] and [51Cr] profiles in the venous outflow. O2 and reference indicator-dilution curves of cerebral circulation were recorded in eight experiments with six halothane-anesthetized dogs. Autologous blood labeled with the tracers was injected into a carotid artery, and brain venous outflow was sampled from the sagittal sinus. The total net extraction of O2 tracer was equal to the extraction of elemental O2. Instantaneous extraction of 18O2 along the outflow curve fell linearly with time, from an initial value of 0.6-0.7 to very small or even negative values toward the end of a pulse. This indicates that O2 undergoes a flow-limited distribution. In all experiments, the mean transit time of unmetabolized 18O2 was longer than the mean transit time of the Cr tracer. An index of the tissue O2 dilution space, hence the mean tissue PO2, is calculated from this data with the use of a modified central volume principle. This estimate of mean tissue PO2 increases as a linear function of sagittal sinus PO2 with a slope of 0.97. The method may provide an index of the critical PO2 of venous blood, the PO2 below which O2 diffusion from blood to tissue may limit its rate of metabolic uptake.  相似文献   

2.
After a single inhalation of C15O2 labelled air, from residual volume to total lung capacity, followed by a few seconds apnea, it is possible to record in four or six lung zones the regional activity changes on a time basis. A first fast rise in activity is seen during the inhalation phase, corresponding to the ventilation in the region of interest (ROI). During the apnea, a slower decreasing component is observed in the different ROI, proportional to the regional blood flow, as almost instantaneously C15O2 is converted to labelled water. After the pioneer work of West & Dollery (1962) very few papers appeared on the subject despite technical improvements as, for instance, coincidence counting of radioactive events. We thus decided to improve the reproducibility and accuracy of the method which were of such a poor quality that no individual measurements were possible in the past. Were of critical importance: a careful positioning of the patients between the counters, a faster electronics improving true coincidence counting. In six healthy volunteers (age 22-35) the values obtained for regional ventilation with the C15O2 single breath were compared to the values given by the inhalation of a poorly soluble gas (Nitrogen13). The correlation between the two sets of measurements is high (r = 0.975). The slope of the regression line is 0.859, ordinate at origin is 2.35. This reveals a systematic error. A mathematical model was therefore developed to take into account the "washout" occurring during the constitution of the ventilation peak, and to correct its value.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
Hyperoxic adult rats have prolonged survival and reduced morphological evidence of lung injury when treated with a single dose of bacterial endotoxin; this effect is mediated by an augmentation of antioxidant enzyme activity in lung homogenate. To determine whether endotoxin would prolong survival and influence antioxidant enzyme levels in lambs whose physiological response to O2 breathing can be serially measured, we administered a single intravenous dose of endotoxin (0.75 microgram/kg body wt) to 13 lambs before exposing them to greater than 95% O2 (n = 11) or air (n = 2). Seven additional lambs were placed in O2 after receiving only saline vehicle. All lambs had been instrumented to measure pulmonary vascular pressures and cardiac output, and 10 lambs had lung lymph fistulas. O2-exposed control lambs developed noncardiogenic pulmonary edema and respiratory failure within 85 +/- 10 h (range 76-110 h); antioxidant enzymes were not increased, but reduced glutathione (GSH) levels fell and oxidized glutathione (GSSG) increased, reflecting the oxidant stress of O2 exposure. By contrast, endotoxin-treated O2-exposed lambs had a delayed increase in microvascular permeability to protein, a reduced rate of lung edema formation, normal gas exchange after 72 h in O2, and prolonged survival (136 +/- 15 h; range 90-160 h; all variables P less than 0.05). Despite prolonged survival, postmortem lung water content was no greater in the lambs that received endotoxin. Treatment with endotoxin did not increase antioxidant enzyme levels in lung homogenate, but levels of GSH relative to GSSG were significantly elevated.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
We have measured regional pulmonary blood flow (PBF) in normal dogs with positron emission tomography (PET) and 15O-labeled water (H2(15)O). The method is nondestructive, quantitative, and repeatable. To measure PBF, PET is used to measure both the initial and equilibrium distribution of lung activity after H2(15)O infusion. The data are then interpreted with a one-compartment mathematical model. Measurements of PBF in dogs with H2(15)O (PBF-water) were compared with PBF measured with 68Ga microspheres (PBF-MS), and a close correlation was observed: PBF-water = 0.82 PBF-MS + 25.4 (R = 0.97, n = 52). In another set of animals an important assumption of the method, namely that the tracer is fully extracted during a single pass through the lung, was demonstrated using a single-probe residue-detection technique. Computer simulations were performed to illustrate the sensitivity of the method to errors in the measured variables of tracer activity or tissue-blood partition coefficient. Results showed only small error magnification for the range of values observed in these studies.  相似文献   

5.
The purpose of these studies was a comparison of [14C]urea (U) and 1,3-[14C]propanediol (Pr) as measures of lung vascular permeability-surface area (PS) under base-line conditions and after lung injury caused by alloxan infusion in isolated perfused dog lungs. Indicator mixtures of 125I-albumin, 51Cr-red blood cells, 3HOH, and U or Pr were injected under base-line conditions, after 1.2 g of alloxan, and after an additional 0.8 g of alloxan. Indicator-dilution curves were analyzed from sampled outflow blood to provide PS, the square root of effective extravascular diffusivity multiplied by exchange surface area (D1/2S), and extravascular lung water (EVLW) from the tracer mean transit times (VW). Results show that alloxan increases PS and D1/2S for U, D1/2S for Pr, and VW and EVLW by desiccation. All indicator-dilution parameters correlate significantly with alloxan dose. Interpretation of Pr transport suggests that materials with lipid and hydrophilic pathways might be used in conjunction with U to minimize the effects of surface area changes and increase the sensitivity of these tracers to permeability alteration. In addition Pr may be a useful alternative to U as a marker of vascular damage.  相似文献   

6.
We recently reported that endotoxin infusion before O2 exposure significantly reduced or delayed the onset of pulmonary edema formation and respiratory failure by reducing the oxidant stress of O2 exposure. Despite these beneficial effects of endotoxin treatment, lung microvascular permeability eventually increased, but postmortem lung water content was less than expected. Prolonged O2 breathing blunts or abolishes the pulmonary constrictor response to alveolar hypoxia in some species, and it is possible that the loss of this response could contribute further to edema formation. To determine whether the reduction in lung edema observed in endotoxin-treated, O2-exposed lambs was linked to the preservation of hypoxic pulmonary vasoconstriction (HPV), we measured pulmonary vascular resistance before and after 8 min of isocarbic hypoxia (inspired O2 fraction 0.12) during each day of O2 exposure. In six control lambs, the pressor response to hypoxia was abolished after 72 h in O2, and the lambs developed respiratory failure shortly thereafter. In six endotoxin-treated lambs, HPV was preserved for as long as 144 h of O2 exposure. In two control O2-exposed lambs in whom HPV was abolished, the infusion of either angiotensin or prostaglandin H2 analogue increased pulmonary vascular resistance by greater than 75%. We conclude that in lambs 1) hyperoxia abolishes the pulmonary vascular response to hypoxia, 2) endotoxin pretreatment reduces acute O2-induced lung injury and preserves the pulmonary constrictor response to hypoxia, and 3) the loss of HPV during O2 exposure may be the result of oxidant-mediated injury to the hypoxia response itself and not the result of diffuse damage to the vasoconstrictor effector mechanism.  相似文献   

7.
We compared the ability of three aerosolized tracers to discriminate among control, lung inflation with a positive end expired pressure of 10 cmH2O, lung vascular hypertension and edema without lung injury, and lung edema with lung injury due to intravenous oleic acid. The tracers were 99mTc-diethylenetriaminepentaacetate (99mTc-DTPA, mol wt 492), 99mTc-human serum albumin (99mTc-ALB, mol wt 69,000), and 99mTc-aggregated albumin (99mTc-AGG ALB, mol wt 383,000). 99mTc-DTPA clearance measurements were not able to discriminate lung injury from lung inflation. The 99mTc-AGG ALB clearance rate was unchanged by lung inflation and increased slightly with lung injury. The 99mTc-ALB clearance rate (0.06 +/- 0.02%/min) was unchanged by lung inflation (0.09 +/- 0.02%/min, P greater than 0.05) or 4 h of hypertension without injury (0.09 +/- 0.04%/min, P greater than 0.05). Deposition of 99mTc-ALB within 15 min of the administration of the oleic acid increased the clearance rate to 0.19 +/- 0.06%/min, which correlated well with the postmortem lung water volume (r = 0.92, P less than 0.01). This did not occur when there was a 60-min delay in the deposition of 99mTc-ALB. We conclude that 99mTc-ALB is the best indicator for studying the effects of lung epithelial injury on protein and fluid transport into and out of the air spaces of the lungs in a minimally invasive manner.  相似文献   

8.
We used the multiple indicator-dilution technique with norepinephrine, a vascular endothelium surface marker, to study the pulmonary vascular changes in awake exercising dogs. The vascular space tracers, labeled erythrocytes and albumin, and a water space tracer, 1,8-octanediol, were injected with the norepinephrine, and right atrium-aortic root dilution curves were obtained in nine dogs, at rest and at two increasing levels of exercise. Extravascular lung water multiple tracer dilutional estimates increased with flow and rapidly approached a maximal asymptotic value representing 75% of the postmortem lung weight. The ratio of the extravascular lung water measured in this way to that measured gravimetrically also increased, to reach an asymptotic proportion of close to 100%. The transit time-defined central vascular space increased linearly with flow; the ratio of lung tissue space to lung vascular space, therefore, decreased with increasing flow. The mean tracer upslope norepinephrine extractions at rest and at the two levels of exercise were 17 +/- 1.2, 14 +/- 0.8, and 15 +/- 0.8% (SE). With the use of the Crone approximation, we computed permeability-surface area products for norepinephrine; these increased linearly with flow. If permeability does not change, the increase in the permeability-surface area product with flow can be attributed to capillary recruitment. We conclude that when all lung tissue has become accessible to 1,8-octanediol delivered via the perfused vascular space, there is nevertheless further recruitment, with increase in flow, of vascular surface that can extract norepinephrine.  相似文献   

9.
The volume and complexity of their vascular systems make the dynamics of long-distance water transport in large trees difficult to study. We used heat and deuterated water (D2)) as tracers to characterize whole-tree water transport and storage properties in individual trees belonging to the coniferous species Pseudotsuga menziesii (Mirb.) Franco and Tsuga heterophylla (Raf.) Sarg. The trees used in this study spanned a broad range of height (13.5-58 m) and diameter (0.14-1.43 m). Sap flow was monitored continuously with heat dissipation probes near the base of the trunk prior to, during and following injection of D2O. The transit time for D2O transport from the base of the trunk to the upper crown and the tracer residence time were determined by measuring hydrogen isotope ratios in water extracted from leaves sampled at regular intervals. Transit times for arrival of D2O in the upper crown ranged from 2.5 to 21 d and residence times ranged from 36 to 79 d. Estimates of maximum sap velocity derived from tracer transit times and path length ranged from 2.4 to 5.4 m d(-1). Tracer residence time and half-life increased as tree diameter increased, independent of species. Species-independent scaling of tracer velocity with sapwood-specific conductivity was also observed. When data from this study were combined with similar data from an earlier study of four tropical angiosperm trees, species-independent scaling of tracer velocity and residence time with sapwood hydraulic capacitance was observed. Sapwood capacitance is an intrinsic tissue-level property that appears to govern whole-tree water transport in a similar manner among both tracheid- and vessel-bearing species.  相似文献   

10.
Several groups of investigators are using external detection of radiolabeled protein to study the flux of protein from plasma into the pulmonary interstitium. A basic assumption for these studies has been that the unbound (free) tracer concentration is small and insignificant. The purpose of this study is to evaluate how free tracer influences the determination of normalized slope index. A five-compartment model for the lung was used with transport equations for both unbound and bound nuclide flux. Parameters of the unbound and bound transport equations were varied to evaluate the sensitivity of normalized slope index to each parameter. The model was also compared with published protein flux data to investigate the validity of the transport model. Application of the model to external scan data provides a sensitive method for evaluating the flux of bound and unbound tracers into the pulmonary interstitium. We conclude that because the distribution volume for unbound tracer is large with respect to protein distribution volume, even a small amount of unbound tracer (2-5%) can create large errors in the determination of normalized slope index.  相似文献   

11.
Importance of vasoconstriction in lipid mediator-induced pulmonary edema   总被引:2,自引:0,他引:2  
Lipid mediators of inflammation cause pulmonary edema, yet it is unclear to what degree hemodynamic alterations or increased vascular permeability contribute to lung edema formation. The isolated rat lung preparation was used to examine the effect of leukotriene C4 (LTC4) and platelet-activating factor (PAF) on pulmonary arterial pressure (Ppa), lung microvascular pressure (Pmv), lung wet-to-dry weight ratio, and the 125I-albumin escape index. We first defined the response of the isolated rat lung perfused with protein-free salt solution to hydrodynamic stress by raising the lung outflow pressure. Sustained elevation of the lung outflow pressure less than 5.5 cmH2O (4.01 mmHg) caused a negligible increase in Ppa and wet-to-dry lung weight ratio. Elevation of outflow pressures greater than 7.5 cmH2O (5.4 mmHg) increased the vascular albumin escape index more than the lung wet-to-dry weight ratio. Dibutyryl adenosine 3',5'-cyclic monophosphate (db-cAMP) inhibited the increase in albumin escape index because of increased lung outflow pressure, suggesting perhaps a pressure-independent microvascular membrane effect of db-cAMP. Both LTC4 (2-micrograms bolus) and PAF (2-2,000 ng/ml perfusate) increased the albumin escape index in association with increases in Ppa and Pmv. Because the increased albumin escape index after LTC4 or PAF injection was largely accounted for by the increased vascular pressures and because db-cAMP and papaverine inhibited the rise in vascular pressures and in the albumin escape index, we conclude that vasoconstriction is an important contributor to LTC4- and PAF-induced edema formation in rat lungs.  相似文献   

12.
Extravascular thermal volume of the lung (ETVL) is a double indicator dilution technique of use in measuring pulmonary edema. ETVL and lung mechanics measurements were followed to find a less invasive monitor of pulmonary edema than the double indicator dilution technique. Pulmonary edema was induced by overloading the dogs' circulation with dextran. Phases of overload were defined on the basis of a previous electron microscopic study (Noble et al., Can. Anesthetists Soc. J. 21:275, 1974) of lung biopsies relating anatomic changes to physiologic measurements of ETVL and central blood volume (CBV). Congestion occurred when CBV was elevated and ETVL was not, interstitial edema when ETVL was elevated but smaller than 60% above control and alveolar edema when ETVL greater than 85% above control. Once the dogs were in alveolar edema, they were mechanically ventilated with 4, 8, 12, and 16 cmH2O end-tidal pressure (CPPV). Mean functional residual capacity (FRC) for all 15 dogs did not change up to the time CPPV was applied. Pulmonary resistance did not rise until alveolar edema was present. Once in pulmonary edema, lung compliance always fell as lung water increased. In individual dogs, the compliance fall was directly proportional to the rising lung water. However, the variations in slope and beginning point among dogs made it difficult to predict the amount of lung water from dynamic compliance values. PaO2 fell markedly in alveolar edema as a result of a widened A-a gradient. CPPV did not decrease lung water but did increase FRC and PaO2.  相似文献   

13.
The application of isotope tracers for investigating metabolism in mice is discussed. To familiarize the reader, some basic principles regarding the use of tracer methods are outlined. Emphasis is placed on showing how investigators are using isotope tracers to study the regulation of carbohydrate, fat and/or protein turnover in vivo. Finally, some of the advantages of using labeled water (i.e., 2H(2)O and/or H(2)18O) to trace the kinetics of biological processes are considered. The background provided in this report should assist engineers in designing studies that enhance our understanding of conditions in which metabolism is altered (e.g., diabetes, cancer cachexia, failure to thrive and travel at zero-gravity).  相似文献   

14.
The detection of radioactive compounds by liquid scintillation has revolutionized modern biology, yet few investigators make full use of the power of this technique. Even though multiple isotope counting is considerably more difficult than single isotope counting, many experimental designs would benefit from using more than one isotope. The development of accurate isotope counting techniques enabling the simultaneous use of three beta-emitting tracers has facilitated studies in our laboratory using the multiple tracer indicator dilution technique for assessing rates of transmembrane transport and cellular metabolism. The details of sample preparation, and of stabilizing the liquid scintillation spectra of the tracers, are critical to obtaining good accuracy. Reproducibility is enhanced by obtaining detailed efficiency/quench curves for each particular set of tracers and solvent media. The numerical methods for multiple-isotope quantitation depend on avoiding error propagation (inherent to successive subtraction techniques) by using matrix inversion. Experimental data obtained from triple-label beta counting illustrate reproducibility and good accuracy even when the relative amounts of different tracers in samples of protein/electrolyte solutions, plasma, and blood are changed.  相似文献   

15.
孙守家  孟平  张劲松  贾长荣  任迎丰 《生态学报》2012,32(12):3892-3901
利用同位素示踪和热扩散技术研究了不同胁迫处理栓皮栎的水分运输和储存差异。结果表明,注射氘同位素后,充分灌溉、轻度和重度胁迫处理的最大氘同位素比率分别升高到586.67‰、997.33‰和1364.89‰,处理间差异显著。轻度和重度胁迫处理的示踪速率分别为0.10 m/h和0.07 m/h,显著低于充分灌溉处理,但半减期和残留期显著高于充分灌溉。轻度和重度胁迫处理的枝条栓塞程度(PLC)比充分灌溉显著增加,液流通量、水势和蒸腾速率则显著减小。统计分析表明蒸腾作用强弱决定树体水分运输速率,PLC的增加和枝条水势的降低阻碍木质部水分运输。半减期和残留期内,轻度和重度胁迫处理的累积液流量显著高于充分灌水处理,运载相同体积的示踪剂,胁迫处理栓皮栎需要的水量增加,表明胁迫环境下受到PLC、蒸腾以及与树体储水交换的影响,水分运输效率下降。栓皮栎通过栓塞和储水交换来降低水分运输速率和效率,调控水分的收支平衡来适应干旱的环境。  相似文献   

16.
Lateral exchange of water and nutrients between xylem and surrounding tissues helps to de‐couple uptake from utilization in all parts of a plant. We studied the dynamics of these exchanges, using stable isotope tracers for water (H218O), magnesium (26Mg), potassium (41K) and calcium (44Ca) delivered via a cut stem for various periods to the transpiration stream of bean shoots (Phaseolus vulgaris cv. Fardenlosa Shiny). Tracers were subsequently mapped in stem cross‐sections with cryo‐secondary ion mass spectrometry. The water tracer equilibrated within minutes across the entire cross‐section. In contrast, the nutrient tracers showed a very heterogeneous exchange between xylem vessels and the different stem tissues, even after 4 h. Dynamics of nutrients in the tissues revealed a fast and extensive exchange of nutrients in the xylem parenchyma, with, for example, calcium being completely replaced by tracer in less than 5 min. Dilution of potassium tracer during its 30 s transit in xylem sap through the stem showed that potassium concentration was up‐regulated over many hours, to the extent that some of it was probably supplied by phloem recirculation from the shoot.  相似文献   

17.
The relations (inflow) = (dose)/(area under indicator curve), and (volume of distribution) = (throughflow) × (mean transit time) are derived by a matrix method for a system of interconnected subsystems, within which spatial indicator activity gradients may exist, and for compartments, within which the indicator activity is spatially uniform. The inflow theorem, is different from the outflow theorem. Equivalent labeling of multi-input systems reduces them formally to single input systems. Foreign indicator flow-volume kinetics are more general than, and include as a special case, tracer flux-mass (metabolic) kinetics. Volume of distribution in the indicator steady state may be different from the equilibrium volume of distribution.  相似文献   

18.
An immunochromatographic-based assay (Quixtrade mark E. coli O157 Sprout Assay) and a polymerase chain reaction (PCR)-based assay (TaqMan E. coli O157:H7 Kit) were used to detect Escherichia coli O157:H7 strain 380-94 in spent irrigation water from alfalfa sprouts grown from artificially contaminated seeds. Ten, 25, 60, or 100 seeds contaminated by immersion for 15 min in a suspension of E. coli O157:H7 at concentrations of 10(6) or 10(8) cfu/ml were mixed with 20 g of non-inoculated seeds in plastic trays for sprouting. The seeds were sprayed with tap water for 15 s every hour and spent irrigation water was collected at intervals and tested. E. coli O157:H7 was detected in non-enriched water by both the TaqMan PCR (30 of 30 samples) and the immunoassay (9 of 24 samples) in water collected 30 h from the start of the sprouting process. However, enrichment of the spent irrigation water in brain heart infusion (BHI) broth at 37 degrees C for 20 h permitted detection of E. coli O157:H7 in water collected 8 h from the start of sprouting using both methods, even in trays containing as few as 10 inoculated seeds. The TaqMan PCR assay was more sensitive (more positive samples were observed earlier in the sprouting process) than the immunoassay; however, the immunoassay was easier to perform and was more rapid. At 72 h after the start of the sprouting process, the sprouts were heated at 100 degrees C for 30 s to determine the effectiveness of blanching for inactivation of E. coli O157:H7. All of the 32 samples tested with the TaqMan assay and 16 of 32 samples tested with the Quixtrade mark assay gave positive results for E. coli O157:H7 after enrichment of the blanched sprouts at 37 degrees C for 24 h. In addition, the organism was detected on Rainbow Agar O157 in 9 of 32 samples after 24 h of enrichment of the blanched sprouts. In conclusion, E. coli O157:H7 was detected in spent irrigation water collected from sprouts grown from artificially contaminated seeds by both the TaqMan and Quixtrade mark assays. The data also revealed that blanching may not be effective to completely inactivate all the E. coli O157:H7 that may be present in sprouts.  相似文献   

19.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

20.
Sixty-six respiratory disease-free rats, divided into four groups, were exposed to 70% O2 for 1.5, 4, 7, and 10 days and compared with 31 littermates exposed to room air for equal times. Lung surfactant was separated from macrophages and potential serum protein contamination by differential centrifugation of endobronchial washings. In the O2-exposed rats, developing lung edema was demonstrated by decreased dried/fresh lung weight ratio and increased alveolar protein content at 7 and 10 days. At 7 days, lung compliance slope and hysteresis loop area decreased, while critical opening pressure increased. Ultrastructurally, the only abnormality seen was an irregular widening of the alveolar capillary basement membrane on day 10. Alveolar lecithin content decreased slightly during the 10 days exposure, but remained highly saturated, whereas whole lung lecithin content increased. These results suggest that the initial mechanical and morphological alterations in rats exposed to 70% O2 are related to lung edema and are not dependent upon lung surfactant alterations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号