首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Current cell-based assays for determining the functional properties of high-density lipoproteins (HDL) have limitations. We report here the development of a new, robust fluorometric cell-free biochemical assay that measures HDL lipid peroxidation (HDLox) based on the oxidation of the fluorochrome Amplex Red. HDLox correlated with previously validated cell-based (r = 0.47, p<0.001) and cell-free assays (r = 0.46, p<0.001). HDLox distinguished dysfunctional HDL in established animal models of atherosclerosis and Human Immunodeficiency Virus (HIV) patients. Using an immunoaffinity method for capturing HDL, we demonstrate the utility of this novel assay for measuring HDLox in a high throughput format. Furthermore, HDLox correlated significantly with measures of cardiovascular diseases including carotid intima media thickness (r = 0.35, p<0.01) and subendocardial viability ratio (r = −0.21, p = 0.05) and physiological parameters such as metabolic and anthropometric parameters (p<0.05). In conclusion, we report the development of a new fluorometric method that offers a reproducible and rapid means for determining HDL function/quality that is suitable for high throughput implementation.  相似文献   

2.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

3.
Miniaturization of high-throughput screening (HTS) assays has several obvious advantages, including increased throughput and lower cost by reduction in reagent consumption. Although absorbance assays are widely used in research laboratories, their application for HTS in a low-volume format has been met with mixed success because they are difficult to miniaturize. Challenges for the miniaturization of absorbance assays include low signal due to short path lengths and meniscus distortions in small well sizes. Here we describe a method to miniaturize absorbance assays to standard, white, low-volume 384-well and 1536-well microplates using a fluorometric plate reader for detection. The premise of this absorbance assay is based on the fluorescent properties of white microplates and the ability of a colored product to quench the fluorescence signal from the plate by absorbing either the excitation light or the emission light. This method was applied to the detection of inorganic phosphate using Quinaldine red and Malachite green dyes and to the monitoring of alkaline phosphatase hydrolysis of p-nitrophenyl phosphate. These assays can be carried out in low volumes, give robust screening statistics, and can be accomplished with a simple, inexpensive fluorometric plate reader.  相似文献   

4.
The green alga Pseudokirchneriella subcapitata has been extensively used for the assessment of adverse impacts of pollutants. Glutathione is involved in antioxidant defence and drug detoxification. Intracellular reduced glutathione (GSH) concentration can be used as an indicator of the health of cells. This work describes a simple and fast fluorescent cell-based assay for the evaluation of intracellular GSH in the alga P. subcapitata, using monochlorobimane (mBCl). Metabolically active algal cells incubated with 50?μmol?L?1 mBCl form fluorescent bimane–glutathione (B-SG) adducts that can be measured fluorometrically. The distribution of GSH (B-SG adducts) in whole cells can be observed by epifluorescence microscopy, in the form of blue fluorescent spots. Depletion of cellular GSH with iodoacetamide, inhibition of glutathione S-transferase with ethacrynic acid or heat-induced death of the cells inhibited the formation of fluorescent adducts in the presence of mBCl. The fluorometric assay, using the 96-well microplate format, was able to detect GSH depletion in algal cells. This cell-based assay can be used to evaluate decreases in GSH content due to exposure to toxicants. This assay is amenable to automation and may be useful in high-throughput toxicity screening using the alga P. subcapitata.  相似文献   

5.
High-throughput screening in the 1536-well format has been largely restricted to solution-based and cell-based screens. In this article, we show the feasibility of a completely automated, robust scintillation proximity assay in the 1536-well format that is suitable to identify inhibitors for a serine/threonine kinase from a compound library. The introduction of [(33)P]phosphate into a biotinylated peptide substrate mirrors the activity of the kinase. The peptide is immobilized on streptavidin-coated LEADseeker imaging beads and [(33)P]phosphate incorporation is detected with the LEADseeker imaging system of Amersham Pharmacia Biotech. To improve the liquid handling procedures for imaging bead suspensions in the low microliter range, we developed a novel trough with an integrated stirring function. A comparison of the 1536-well assay to a 384-well assay revealed a comparable assay quality with Z' factors of about 0.7 for the 384-well format and 0.6 for the 1536-well format. In an automated screen of a random compound collection, 94.4% of the inhibitory compounds could be identified with both assay formats. Dose-response curves were performed for a selection of identified kinase inhibitors and revealed similar IC(50) values for both assay formats.  相似文献   

6.
7.
TRPM2 is a member of the transient receptor potential melastatin (TRPM)-related ion channel family. The activation of TRPM2 induced by oxidative/nitrosative stress leads to an increase in intracellular free Ca(2+). Although further progress in understanding TRPM2's role in cell and organism physiology would be facilitated by isolation of compounds able to specifically modulate its function in primary cells or animal models, no cell-based assays for TRPM2 function well suited for high-throughput screening have yet been described. Here, a novel suspension B lymphocyte cell line stably expressing TRPM2 was used to develop a cell-based assay. The assay uses the Ca(2+)-sensitive fluorescence dye, Fluo-4 NW (no wash), to measure TRPM2-dependent Ca(2+) transients induced by H(2)O(2) and N-methyl-N'-nitrosoguanidine in a 96-well plate format. Assay performance was evaluated by statistical analysis of the Z' factor value and was consistently greater than 0.5 under optimal conditions, suggesting that the assay is very robust. For assay validation, the effects of known inhibitors of TRPM2 and TRPM2 gating secondary messenger production were determined. Overall, the authors have developed a cell-based assay that may be used to identify TRPM2 ion channel modulators from large compound libraries.  相似文献   

8.
A sensitive fluorometric assay for the quantification of phosphite has been developed. The assay uses the enzymatic oxidation of phosphite to phosphate by a recombinant phosphite dehydrogenase with NAD+ as cosubstrate to produce the highly fluorescent reaction product resorufin. The optimized assay can be carried out in a 96-well microtiter plate format for high-throughput screening purposes and has a detection limit of 0.25 nmol phosphite. We used the method to quantify phosphite levels in plant tissue extracts and to determine phosphite dehydrogenase activity in transgenic plants. The assay is suitable for other biological or environmental samples. Because phosphite is a widely used fungicide to protect plants from pathogenic oomycetes, the assay provides a cost-effective and easy-to-use method to monitor the fate of phosphite following application.  相似文献   

9.
The authors describe a cell-based assay for anti-microtubule compounds suitable for automation. This assay allows the identification, in a single screening campaign, of both microtubule-destabilizing and microtubule-stabilizing agents. Its rationale is based on the substrate properties of the tubulin-modifying enzymes involved in the tubulin tyrosination cycle. This cycle involves the removal of the C-terminal tyrosine of the tubulin alpha-subunit by an ill-defined tubulin carboxypeptidase and its readdition by tubulin tyrosine ligase. Because of the substrate properties of these enzymes, dynamic microtubules, sensitive to depolymerizing drugs, are composed of tyrosinated tubulin, whereas non-dynamic, stabilized microtubules are composed of detyrosinated tubulin. Thus depolymerization or stabilization of the microtubule network can easily be detected with double-immunofluorescence staining using antibodies specific to tyrosinated and detyrosinated tubulin. The authors have scaled this assay to the 96-well plate format and adapted its process for an automated handling, including a readout using a microplate reader. They describe the different steps of this adaptation. This assay was validated using known compounds. This new cell-based assay represents an alternative to both global cytotoxicity assays and in vitro tubulin assembly assays commonly used for the detection of microtubule poisons.  相似文献   

10.
11.
12.
Decreases in mitochondrial membrane potential (MMP) have been associated with mitochondrial dysfunction that could lead to cell death. The MMP is generated by an electrochemical gradient via the mitochondrial electron transport chain coupled to a series of redox reactions. Measuring the MMP in living cells is commonly used to assess the effect of chemicals on mitochondrial function; decreases in MMP can be detected using lipophilic cationic fluorescent dyes. To identify an optimal dye for use in a high-throughput screening (HTS) format, we compared the ability of mitochondrial membrane potential sensor (Mito-MPS), 5,5',6,6'-tetrachloro-1,1',3,3' tetraethylbenzimidazolylcarbocyanine iodide, rhodamine 123, and tetramethylrhodamine to quantify a decrease in MMP in chemically exposed HepG2 cells cultured in 1,536-well plates. Under the conditions used, the optimal dye for this purpose is Mito-MPS. Next, we developed and optimized a homogenous cell-based Mito-MPS assay for use in 1,536-well plate format and demonstrated the utility of this assay by screening 1,280 compounds in the library of pharmacologically active compounds in HepG2 cells using a quantitative high-throughput screening platform. From the screening, we identified 14 compounds that disrupted the MMP, with half-maximal potencies ranging from 0.15 to 18 μM; among these, compound clusters that contained tyrphostin and 3'-substituted indolone analogs exhibited a structure-activity relationship. Our results demonstrate that this homogenous cell-based Mito-MPS assay can be used to evaluate the ability of large numbers of chemicals to decrease mitochondrial function.  相似文献   

13.
A fluorometric method for the enzymatic determination of cholesterol content has been developed using a novel fluorogenic H2O2 probe, Amplex Red. This assay is performed in a 96-well microplate, and it is a one-step method amenable to automated procedures. Using commercially available cholesterol, our assay allows detection of 5 pmol (2 ng) cholesterol per well, which is 100-fold more sensitive than published fluorometric and colorimetric methods. When applied to the measurement of cholesterol levels in serum and food samples, the Amplex Red-based method has been found more attractive since the oxidation product of the Amplex Red method has superior long wavelength spectra which are less susceptible to interference from the biological compounds.  相似文献   

14.
High-throughput screening of RNAi libraries has become an essential part of functional analysis in academic and industrial settings. The transition of a cell-based RNAi assay into a 384-well format requires several optimization steps to ensure the phenotype being screened is appropriately measured and that the signal-to-background ratio is above a certain quantifiable threshold. Methods currently used to assess small interfering RNA (siRNA) efficacy after transfection, including quantitative PCR or branch DNA analysis, face several technical limitations preventing the accurate measurement of mRNA levels in a 384-well format. To overcome these difficulties, the authors developed an approach using a viral-based transfection system that measures siRNA efficacy in a standardized 384-well assay. This method allows measurement of siRNA activity in a phenotypically neutral manner by quantifying the knockdown of an exogenous luciferase gene delivered by a lentiviral vector. In this assay, the efficacy of a luciferase siRNA is compared to a negative control siRNA across many distinct assay parameters including cell type, cell number, lipid type, lipid volume, time of the assay, and concentration of siRNA. Once the siRNA transfection is optimized as a 384-well luciferase knockdown, the biologically relevant phenotypic analysis can proceed using the best siRNA transfection conditions. This approach provides a key technology for 384-well assay development when direct measurement of mRNA knockdown is not possible. It also allows for direct comparison of siRNA activity across cell lines from almost any mammalian species. Defining optimal conditions for siRNA delivery into mammalian cells will greatly increase the speed and quality of large-scale siRNA screening campaigns.  相似文献   

15.
A novel cell-based functional assay to directly monitor G protein-coupled receptor (GPCR) activation in a high-throughput format, based on a common GPCR regulation mechanism, the interaction between beta-arrestin and ligand-activated GPCR, is described. A protein-protein interaction technology, the InteraX trade mark system, uses a pair of inactive beta-galactosidase (beta-gal) deletion mutants as fusion partners to the protein targets of interest. To monitor GPCR activation, stable cell lines expressing both GPCR- and beta-arrestin-beta-gal fusion proteins are generated. Following ligand stimulation, beta-arrestin binds to the activated GPCR, and this interaction drives functional complementation of the beta-gal mutant fragments. GPCR activation is measured directly by quantitating restored beta-gal activity. The authors have validated this assay system with two functionally divergent GPCRs: the beta2-adrenergic amine receptor and the CXCR2 chemokine-binding receptor. Both receptors are activated or blocked with known agonists and antagonists in a dose-dependent manner. The beta2-adrenergic receptor cell line was screened with the LOPAC trade mark compound library to identify both agonists and antagonists, validating this system for high-throughput screening performance in a 96-well microplate format. Hit specificity was confirmed by quantitating the level of cAMP. This assay system has also been performed in a high-density (384-well) microplate format. This system provides a specific, sensitive, and robust methodology for studying and screening GPCR-mediated signaling pathways.  相似文献   

16.
This report describes the development of a cell-based assay for high-throughput screening and detection of small-molecule inhibitors for hepatitis C virus (HCV) NS2/3 protease. The HCV NS2/3 protease is essential for the normal infectious cycle of HCV. Generation of a cell-based assay for this cis-acting viral protease involved reporter constructs in which the NS2/3 protease sequence was inserted between the ,B-lactamase (BLA) reporter and a ubiquitin-based destabilization domain. In stable cell lines, NS2/3 cis cleavage of the NS2/3-BLA fusion protein resulted in differential stability of the cleaved versus uncleaved BLA reporter, providing a robust readout for protease activity. BLA reporter activity was shown to be a function of NS2/3-specific protease activity, by using genetic mutants of the NS2/3 sequence. In addition, the cell-based assay was validated and screened in a 384-well format on a fully automated robotic platform where small-molecule inhibitors of NS2/3 protease activity were identified.  相似文献   

17.
Endothelial lipase (EL) is a 482-amino-acid protein from the triglyceride lipase gene family that uses a Ser-His-Asp triad for catalysis. Its expression in endothelial cells and preference for phospholipids rather than triglycerides are unique. Animal models in which it is overexpressed or knocked out indicate EL levels are inversely correlated with high-density lipoprotein cholesterol (HDL-C). HDL-C is commonly referred to as the good form of cholesterol because it is involved in the reverse cholesterol transport pathway, in which excess cholesterol is effluxed from peripheral tissues for excretion or reabsorption. Thus, EL inhibition in humans is expected to lead to increases in HDL levels and possibly a decrease in cardiovascular disease. To discover inhibitors of EL, a coupled assay for EL has been developed, using its native substrate, HDL. Hydrolysis of HDL by EL yields free fatty acids, which are coupled through acyl-CoA synthetase, acyl-CoA oxidase, and horseradish peroxidase to produce the fluorescent species resorufin. This assay was developed into a 5-microL, 1536-well assay format, and a high-throughput screen was executed against the GSK collection. In addition to describing the screening results, novel post-HTS mechanism-of-action studies were developed for EL and applied to 1 of the screening hits as an example.  相似文献   

18.
A simple, optical density-based assay for inhibitors of the mevalonate-dependent pathway for isoprenoid biosynthesis was developed. The assay uses pathway-sensitized Staphylococcus aureus strains and is fully compatible with high-density screening in a 1536-well format. S. aureus strains were constructed in which genes required for mevalonate-dependent isopentenyl pyrophosphate (IPP) synthesis were regulated by an isopropyl-β-D-thiogalactopyranoside (IPTG)-inducible promoter. Inhibitors of the target enzymes displayed greater antibacterial potency in media containing low concentrations of IPTG, and therefore less induction of mevalonate pathway genes, than in media with high IPTG conditions. This differential growth phenotype was exploited to bias the cell-based screening hits toward specific inhibitors of mevalonate-dependent IPP biosynthesis. Screens were run against strains engineered for regulation of the enzymes HMG-CoA synthase (MvaS) and mevalonate kinase (mvaK1), mevalonate diphosphate decarboxylase (mvaD), and phosphomevalonate kinase (mvaK2). The latter three enzymes are regulated as an operon. These assays resulted in the discovery of potent antibacterial hits that were progressed to an active hit-to-lead program. The example presented here demonstrates that a cell sensitization strategy can be successfully applied to a 1.3-million compound high-throughput screen in a high-density 1536-well format.  相似文献   

19.
A standardized dichlorofluorescin (DCF) fluorometric assay capable of measuring radiation-induced oxidative stress was used to determine the effectiveness of protons and high-mass, high-atomic number (Z) and high-energy (HZE) particles to produce oxidative stress in vitro. Protons were found to be about equally as effective as X rays in the generation of oxidative stress in cultured cells. However, 56Fe-ion beams with energies of 1 GeV/nucleon and 5 GeV/nucleon were less effective than X rays or gamma rays in inducing dichlorofluorescin (DCFH) oxidation. The relatively lower slope values for the dose responses of HZE-particle radiation-induced DCFH oxidation indicate that the sensitivity of the DCF fluorometric assay is probably dependent on the linear energy transfer (LET) of the radiation beam.  相似文献   

20.
p56(lck) is a lymphocyte-specific tyrosine kinase that plays an important role in both T-cell maturation and activation. We have developed a homogeneous assay in which p56(lck) catalyzes the transfer of the gamma-phosphate group from [gamma-(33)P]ATP to a biotinylated peptide substrate. The labeled peptide is then captured on a streptavidin-coated scintillation proximity assay (SPA) bead or imaging proximity bead. The SPA is counted in a microplate scintillation counter and the imaging proximity assay is counted in a charge-coupled device-based imaging system called LEADseekertrade mark, recently launched as a homogeneous imaging system by Amersham Pharmacia Biotech. We show, via time-dependence assays and inhibitor studies, that this assay can be performed in 1536-well microplate format using imaging proximity as the method of detection. The results compare favorably with the same assay performed in 384-well microplate format using both SPA and imaging proximity as the detection methods. From this study, we conclude that a kinase assay can be performed in 384- and 1536-well format using imaging as the detection method, with significant time savings over standard scintillation counting. In addition, we show cost saving advantages of 1536- over 384-well format in terms of reagent usage, higher throughput, and waste disposal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号