1.
Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR). A three-dimensional finite element model was developed based on a modular MoP bearing. Different cup inclination angles and head lateral microseparation were modelled and their effect on the contact mechanics of the modular MoP hip replacement were examined. The results showed that lateral microseparation caused loading of the head on the rim of the cup, which produced substantial increases in the maximum von Mises stress in the polyethylene liner and the maximum contact pressure on both the articulating surface and backside surface of the liner. Plastic deformation of the liner was observed under both standard conditions and microseparation conditions, however, the maximum equivalent plastic strain in the liner under microseparation conditions of 2000 µm was predicted to be approximately six times that under standard conditions. The study has indicated that correct positioning the components to avoid edge loading is likely to be important clinically even for hard-on-soft bearings for THR.  相似文献   

2.
Squeaking of hip replacements with ceramic-on-ceramic bearings has put the use of this material into question despite its superior wear behavior. Squeaking has been related to implant design. The purpose of this study was to determine the influence of particular acetabular cup and femoral stem designs on the incidence of squeaking and its characteristics. The dynamic behavior of the stem, head and stem assembled with head was investigated by determining their eigenfrequencies using experimental and numerical modal analysis. Four different stem and three different cup designs were investigated. Operational system vibrations resulting in audible squeaking were reproduced in a hip simulator and related to the respective component eigenfrequencies. The applied joint load and bearing clearance were varied in the clinically relevant range. Stems with lower eigenfrequencies were related to lower squeaking frequencies and increased acoustic pressure (loudness), and therefore to a higher susceptibility to squeaking. Higher load increased the squeaking frequency, while the acoustic pressure remained unchanged. No influence of the clearance or the cup design was found. Stem design was found to have an important influence on squeaking characteristics and its incidence, confirming and explaining similar clinical observations. Cup design itself was found to have no major influence on the dynamic behavior of the system but plays an important indirect role in influencing the magnitude of friction: Squeaking only occurs if the friction in the joint articulation is sufficient to excite vibrations to audible magnitudes. If friction is low, no squeaking occurs with any of the designs investigated.  相似文献   

3.
A crutch is prescribed to permit the patient to walk safely and independently immediately after total hip replacement (THR) surgery. Purpose of this study is to evaluate the influence of the crutch setup on upper limbs biomechanics, including shoulder joint kinematics and kinetics parameters that will be evaluated to detect possible differences related to the crutch length.Thirty patients were randomly assigned to elbow flexed (EF) or elbow extended (EE) forearm crutch setup. Subjects were asked to walk on the laboratory path, instrumented with motion tracking system and force platforms. Spatiotemporal gait parameters, crutch ground reaction force (GRF) and crutch displacement (measured as the relative distance between the crutch position on the floor and the shoulder joint center), were evaluated. A three-dimensional (3D) biomechanical model was implemented to determine shoulder joint kinematics and kinetics during crutch walking.Results showed that the stride length significantly decreased, and base of support width increased for the EF group when compared to the EE group. Crutch forces and distance to the body significantly decreased in the EE group. Furthermore, shoulder joint moments in all planes of motion, vertical and lateral forces were significantly reduced in the EE group.The present study showed that crutch setup influenced performance and upper limb loading during walking, with EE setup allowing a more stable walking and reducing stress on the shoulder joint when compared to the EF setup. Results may help therapists in rationalizing crutch length adjustments for patients after THR surgery.  相似文献   

4.
Patient imaging and explant analysis has shown evidence of edge loading of hard-on-hard hip replacements in vivo. Experimental hip simulator testing under edge loading conditions has produced increased, clinically-relevant, wear rates for hard-on-hard bearings when compared to concentric conditions. Such testing, however, is time consuming and costly. A quick running computational edge loading model (Python Edge Loading (PyEL) - quasi-static, rigid, frictionless), capable of considering realistic bearing geometries, was developed. The aim of this study was to produce predictions of separation within the typical experimental measurement error of ∼0.5 mm. The model was verified and validated against comparable finite element (FE) models (including inertia and friction) and pre-existing experimental test data for 56 cases, covering a variety of simulated cup orientations, positions, tissue tensions, and loading environments. The PyEL model agreed well with both the more complex computational modelling and experimental results. From comparison with the FE models, the assumption of no inertia had little effect on the maximum separation prediction. With high contact force cases, the assumption of no friction had a larger effect (up to ∼5% error). The PyEL model was able to predict the experimental maximum separations within ∼0.3 mm. It could therefore be used to optimise an experimental test plan and efficiently investigate a much wider range of scenarios and variables. It could also help explain trends and damage modes seen in experimental testing through identifying the contact locations on the liner that are not easily measured experimentally.  相似文献   

5.
The purpose of this study was to evaluate whether preoperative gait adaptations persist one year after THR in the same set of subjects. The hypothesis tested was that hip dynamic range of motion and peak external moments during walking return to normal after THR. Hip kinematics and kinetics were measured for 28 subjects before and one year after THR and compared to those of 25 subjects with radiographically normal hips. All THR subjects improved clinically after surgery with Harris hip scores improving from 33-85 (average 53) to 61-100 (average 95) (sign test p<0.001). Preoperatively dynamic hip range of motion (ROM), and all peak external moments were reduced compared to normal (Mann-Whitney p< or =0.040). Improvement was seen in the ROM and all but the frontal plane, and external rotation peak moments (Friedman p< or =0.023). The preoperative and postoperative values of the ROM, and peak flexion, abduction and external rotation moments were all significantly correlated (Spearman p<0.020) indicating a possible learned effect from before THR surgery. Postoperative THR subjects continued to have a significantly lower than normal ROM, and peak adduction and peak internal rotation moments (Mann-Whitney p< or =0.003). Despite good to excellent clinical functional outcome, gait in THR patients does not return to normal by one year after surgery. Aggressive muscle strengthening is currently not emphasized after THR surgery. Some THR patients may benefit from more intensive rehabilitation before and after surgery.  相似文献   

6.
7.
Knee joint kinematics is the focus of a significant amount of experimental study for the purpose of knee prosthesis design and for testing the wear of current and prospective bearing materials. This study reports the wear assessment of a series of 94 explanted tibial bearings of various designs and manufacturers and focuses on the extent to which clinical wear is symmetric in the medial-lateral aspect, or is indicative of a systematic asymmetry that would be informative to the design and testing of knee prostheses or surgical practice. Wear assessment of the series of retrievals indicates that, statistically, there was more clinical wear on the medial side. Patterns of wear varied greatly among individual knees; a majority showed very similar extents of wear on the medial and lateral sides, however there were cases with significantly more wear on one condylar articulation than the other. Evidence of edge loading, whereby the femoral component articulates at the margin of the tibial bearing, was common. It was seen most frequently in the central zone of the medial condylar area, and, like the overall wear, edge loading was significantly more frequent on the medial side of bearings. Total bearing wear was seen to generally increase with time over the 208 months of in vivo duration covered by the retrievals in the study. The medial-lateral asymmetry of the wear does not appear to be significantly dependent on duration, however.  相似文献   

8.
This paper presents a computational simulator for the hip to compute the wear and heat generation on artificial joints. The friction produced on artificial hip joints originates wear rates that can lead to failure of the implant. Furthermore, the frictional heating can increase the wear. The developed computational model calculates the wear in the joint and the temperature in the surrounding zone, allowing the use of different combinations of joint materials, daily activities and different individuals. The pressure distribution on the joint bearing surfaces is obtained with the solution of a contact model. The heat generation by friction and the volumetric wear is computed from the pressure distribution and the sliding distance. The temperature is obtained from the solution of a transient heat conduction problem that includes the time-dependent heat generated by friction. The contact and heat conduction problems are solved numerically with the Finite Element Method. The developed computational model performs a full simulation of the acetabular bearing surface behaviour, which is useful for acetabular cup design and material selection. The results obtained by the present model agree with experimental and clinical data, as well as other numerical studies.  相似文献   

9.
As one of the alternatives to traditional metal-on-polyethylene total hip replacements, metal-on-metal hip resurfacing prostheses demonstrating lower wear have been introduced for younger and more active patients during the past decade. However, in vitro hip simulator testing for the predicted increased lifetime of these surface replacements is time-consuming and costly. Computational wear modelling based on the Archard wear equation and finite element contact analysis was developed in this study for artificial hip joints and particularly applied to metal-on-metal resurfacing bearings under simulator testing conditions to address this issue. Wear factors associated with the Archard wear equation were experimentally determined and based on the short-term hip simulator wear results. The computational wear simulation was further extended to a long-term evaluation up to 50 million cycles assuming that the wear rate stays constant. The prediction from the computational model shows good agreement with the corresponding simulator study in terms of volumetric wear and the wear geometry. The simulation shows the progression of linear wear penetrations, and the complexity of contact stress distribution on the worn bearing surfaces. After 50 million cycles, the maximum linear wear was predicted to be approximately 6 and 8 microm for the cup and head, respectively, and no edge contact was found.  相似文献   

10.
To examine functional differences in total hip replacement patients (THR) when stratified either by age or by functional ability as defined by self-selected walking speed. THR patients and a control group underwent three-dimensional motion analysis under self-selected normal and fast walking conditions. Patients were stratified into five age groups for comparison with existing literature. The THR cohort was also stratified into three functional groups determined by their self-selected gait speed (low function <1SD of total cohort’s mean walking speed; high function >1SD; normal function within 1SD). Hip kinematics, ground reaction forces, joint moments and joint powers in all three planes (x-y-z) were analysed. 137 THR and 27 healthy control patients participated. When stratified by age, during normal walking the youngest two age groups walked quicker than the oldest two groups (p < 0.0001) but between-group differences were not consistent across age strata. The differences were diminished under the fast walking condition. When stratified by function, under normal walking conditions, the low function and normal function THR groups had a reduced extension angle (mean = 1.75°, SD = ±7.75, 1.26° ± 7.42, respectively) compared to the control group (−6.07° ± 6.43; p < 0.0001). The low function group had a reduced sagittal plane hip power (0.75 W/kg ± 0.24), reduced flexor (0.60 Nm/kg ± 0.85) and extensor moment (0.51 Nm/kg ± 0.17) compared to controls (p < 0.0001). These differences persisted under the fast walking condition. There were systematic differences between patients when stratified by function, in both walking conditions. Age-related differences were less systematic. Stratifying by biomechanical factors such as gait speed, rather than age, might be more robust for investigating functional differences.  相似文献   

11.
Variation in hip joint contact forces directly influences the performance of total hip replacements (THRs). Measurement and calculation of contact forces in THR patients has been limited by small sample sizes, wide variation in patient and surgical factors, and short-term follow-up. This study hypothesised that, at long-term follow-up, unilateral THR patients have similar calculated hip contact forces compared to controls walking at similar (self-selected) speeds and, in contrast, THR patients walking at slower (self-selected) speeds have reduced hip contact forces. It was further hypothesised that there is no difference in calculated hip contact forces between operated and non-operated limbs at long-term follow-up for both faster and slower patients. Gait analysis data for THR patients walking at faster (walking speed: 1.29 ± 0.12 m/s; n = 11) and slower (walking speed: 0.72 ± 0.09 m/s; n = 11) speeds were used. Healthy subjects constituted the control group (walking speed: 1.36 ± 0.12 m/s; n = 10). Hip contact forces were calculated using static optimisation. There was no significant difference (p > 0.31) in hip contact forces between faster and control groups. Conversely, force was reduced at heel strike by 19% (p = 0.002), toe-off by 31% (p < 0.001) and increased at mid-stance by 15% (p = 0.02) for the slower group compared to controls. There were no differences between operated and non-operated limbs for the slower group or the faster group, suggesting good biomechanical recovery at long-term follow-up. Loading, at different walking speeds, presented here can improve the relevance of preclinical testing methods.  相似文献   

12.
Wear particle accumulation is one of the main contributors to osteolysis and implant failure in hip replacements. Altered kinematics produce significant differences in wear rates of hip replacements in simulator studies due to varying degrees of multidirectional motion. Gait analysis data from 153 hip-replacement patients 10-years post-operation were used to model two- and three-dimensional wear paths for each patient. Wear paths were quantified in two dimensions using aspect ratios and in three dimensions using the surface areas of the wear paths, with wear-path surface area correlating poorly with aspect ratio. The average aspect ratio of the patients wear paths was 3.97 (standard deviation=1.38), ranging from 2.13 to 10.86. Sixty percent of patients displayed aspect ratios between 2.50 and 3.99. However, 13% of patients displayed wear paths with aspect ratios >5.5, which indicates reduced multidirectional motion. The majority of total hip replacement (THR) patients display gait kinematics which produce multidirectional wear paths, but a significant minority display more linear paths.  相似文献   

13.
Although hip simulators for in vitro wear testing of prosthetic materials used in total hip arthroplasty (THA) have been available for a number of years, similar equipment has yet to appear for endurance testing of fixation in cemented THA, despite considerable evidence of late aseptic loosening as one of the most significant failure mechanisms in this type of replacements. An in vitro study of fatigue behavior in cemented acetabular replacements has been carried out, utilizing a newly developed hip simulator. The machine was designed to simulate the direction and the magnitude of the hip contact force under typical physiological loading conditions, including normal walking and stair climbing, as reported by Bergmann et al. (2001, Hip 98, Freie Universitaet, Berlin). A 3D finite element analysis has been carried out to validate the function of the hip simulator and to evaluate the effects of boundary conditions and geometry of the specimen on the stress distribution in the cement mantle. Bovine pelvic bones were implanted with a Charnley cup, using standard manual cementing techniques. Experiments were carried out under normal walking and descending stairs loading conditions with selected load levels from a body weight of 75-125 kg. Periodically, the samples were removed from the test rigs to allow CT scanning for the purpose of monitoring damage development in the cement fixation. The hip simulator was found to be satisfactory in reproducing the hip contact force during normal walking and stair climbing, as reported by Bergmann et al. Finite element analysis shows that the stress distributions in the cement mantle and at the bone-cement interface are largely unaffected by the geometry and the boundary conditions of the model. Three samples were tested up to 17 x 10(6) cycles and sectioned post-testing for microscopic studies. Debonding at the bone-cement interface of various degrees in the posterior-superior quadrant was revealed in these samples, and the location of the failures corresponds to the highest stressed region from the finite-element analysis. Preliminary experimental results from a newly developed hip simulator seem to suggest that debonding at the bone-cement interface is the main failure mechanism in cemented acetabular replacements, and descending stairs seem to be more detrimental than normal walking or ascending stairs with regard to fatigue integrity of cement fixation.  相似文献   

14.
For clinically predictive testing and design-phase evaluation of prospective total knee replacement (TKR) implants, devices should ideally be evaluated under physiological loading conditions which incorporate population-level variability. A challenge exists for experimental and computational researchers in determining appropriate loading conditions for wear and kinematic knee simulators which reflect in vivo joint loading conditions. There is a great deal of kinematic data available from fluoroscopy studies. The purpose of this work was to develop computational methods to derive anterior–posterior (A–P) and internal–external (I–E) tibiofemoral (TF) joint loading conditions from in vivo kinematic data. Two computational models were developed, a simple TF model, and a more complex lower limb model. These models were driven through external loads applied to the tibia and femur in the TF model, and applied to the hip, ankle and muscles in the lower limb model. A custom feedback controller was integrated with the finite element environment and used to determine the external loads required to reproduce target kinematics at the TF joint. The computational platform was evaluated using in vivo kinematic data from four fluoroscopy patients, and reproduced in vivo A–P and I–E motions and compressive force with a root-mean-square (RMS) accuracy of less than 1 mm, 0.1°, and 40 N in the TF model and in vivo A–P and I–E motions, TF flexion, and compressive loads with a RMS accuracy of less than 1 mm, 0.1°, 1.4°, and 48 N in the lower limb model. The external loading conditions derived from these models can ultimately be used to establish population variability in loading conditions, for eventual use in computational as well as experimental activity simulations.  相似文献   

15.
A new definition of the experimental wear factor was established and reported as a function of cross-shear motion and contact pressure using a multi-directional pin-on-plate wear testing machine for conventional polyethylene in the present study. An independent computational wear model was developed by incorporating the cross-shear motion and contact pressure-dependent wear factor into the Archard's law, in additional to load and sliding distance. The computational prediction of wear volume was directly compared with a simulator testing of a polyethylene hip joint with a 28 mm diameter. The effect of increasing the femoral head size was subsequently considered and was shown to increase wear, as a result of increased sliding distance and reduced contact pressure.  相似文献   

16.
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.  相似文献   

17.
The purposes of this study were to compare lower-limb kinematics between genders, and determine the relationships among eccentric hip abductor and lateral rotator torques and lower-limb kinematics. The movements of the pelvis, femur, and knee were calculated for 16 women and 16 men during the single-leg squat. Eccentric hip abductor and lateral rotator torques were measured using an isokinetic dynamometer. The results showed that women had greater contralateral pelvic depression, femur adduction, and knee abduction than men. The eccentric hip abductor and lateral rotator torques were correlated with coronal plane femur and knee movements in the overall sample. When the genders were analyzed separately, it was observed that women with greater eccentric hip abductor torque exhibited less femur adduction and femur medial rotation, and greater knee adduction excursion. No significant relationship was observed between the isokinetic and kinematic variables in the male group. The differences between the genders help to explain the greater rate of knee disorders observed in women. Moreover, the eccentric hip abduction action seemed to be more important in women to control the lower-limb movements.  相似文献   

18.
The purpose of the present study was to determine the effects of orthoses designed to support the forefoot and rearfoot on the kinematics and kinetics of the lower extremity joints during walking. Fifteen participants volunteered for this study. Kinematic and kinetic variables during overground walking were compared with the participants wearing sandals without orthoses or sandals with orthoses. Orthoses increased knee internal abduction moment during late stance and knee abduction angular impulse, and reduced the medial ground reaction force during late stance, adduction free moment, forefoot eversion angle, ankle inversion moment and angular impulse, hip adduction angle, hip abduction moment, and hip external rotation moment and angular impulse (p<0.05). Orthoses decreased the torsional forces on the lower extremity and reduced the loading at the hip during walking. These findings combined with our previous studies and those of others suggest that forefoot abnormalities are critically important in influencing lower extremity kinematics and kinetics, and may underlie some non-traumatic lower extremity injuries.  相似文献   

19.
Knee varus position and motion have been correlated with increased medial knee loading during gait. The purpose of this study is to determine whether runners with excessive varus excursion (EVE) at the knee demonstrate frontal plane knee and hip kinetics that are different from those of runners with normal varus excursion (NVE). Twelve runners with EVE were compared with 12 NVE subjects using three-dimensional kinematics and kinetics. Frontal plane angles and moments were compared at the knee and hip. Runners with EVE had significantly greater abductor moment of the knee (p = .004) and lower peak abductor moment of the hip (p = .047). Runners with EVE demonstrate knee and hip mechanics thought to be associated with increased medial tibiofemoral loading. Further understanding of how changing hip abductor moments may affect changes in knee abductor moments during running may potentially lead to interventions that augment long-term risk of injury.  相似文献   

20.
Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.  相似文献   