6.
Ceramic-on-metal (CoM) bearings are considered to be a promising alternative to polyethylene-based bearings or hard-on-hard bearings (Ceramic-on-Ceramic (CoC) and Metal-on-Metal (MoM)). Although, CoM shows lower wear rates than MoM, in-vitro wear testing of CoM shows widely varying results. This may be related to limitations of wear-measuring methods. Therefore, the aim of this study was to improve the gravimetric measurement technique and to test wear behaviour of CoM bearings compared to CoC bearings. Level walking according to ISO-14242 was simulated for four CoM and four CoC bearings. Prior to simulation, errors in measurement of gravimetric wear were detected and improvements in measurement technique incorporated. The results showed no differences in mean wear rates between CoM and CoC bearings. However, the CoM bearings showed wear results over a wide range of wear performance. High reliability of wear results was recorded for the CoC bearings. Material transfer was observed on the ceramic heads of the CoM bearings. Therefore, for level walking a partial mixed or boundary lubrication has to be assumed for this type of bearing. CoM is a highly sensitive wear-couple. The reasons for the observed behaviour cannot be clarified from this study. Simulator studies have to be considered as an ideal loading condition. Therefore, high variations in wear rates as seen in this study, even at low levels, may have an adverse effect on the in-vivo wear behavior. Careful clinical use may be advisable until the reasons for the variation are fully clarified and understood.  相似文献   

7.
<正> Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces.  相似文献   

8.
金属对金属全髋假体由于其具有良好的活动度因而被广泛应用全髋关节置换,但是由于金属对金属全髋假体置换术后可以产生大量的钴铬金属离子而使机体内血液尿液中金属离子水平升高,而金属离子水平升高后可能会对机体产生不利影响,本文就金属对金属全髋假体置换术后对机体的影响作一综述。  相似文献   

9.
张方杰  雷光华 《生物磁学》2011,(13):2558-2561,2583
金属对金属全髋假体由于其具有良好的活动度因而被广泛应用全髋关节置换,但是由于金属对金属全髋假体置换术后可以产生大量的钴铬金属离子而使机体内血液尿液中金属离子水平升高,而金属离子水平升高后可能会对机体产生不利影响,本文就金属对金属全髋假体置换术后对机体的影响作一综述。  相似文献   

10.
11.
Multinucleate giant cells (MGCs) are formed by the fusion of 5 to 15 monocytes or macrophages. MGCs can be generated by hip implants at the site where the metal surface of the device is in close contact with tissue. MGCs play a critical role in the inflammatory processes associated with adverse events such as aseptic loosening of the prosthetic joints and bone degeneration process called osteolysis. Upon interaction with metal wear particles, endothelial cells upregulate pro-inflammatory cytokines and other factors that enhance a localized immune response. However, the role of endothelial cells in the generation of MGCs has not been completely investigated. We developed a three-dimensional peripheral tissue-equivalent model (PTE) consisting of collagen gel, supporting a monolayer of endothelial cells and human peripheral blood mononuclear cells (PBMCs) on top, which mimics peripheral tissue under normal physiological conditions. The cultures were incubated for 14 days with Cobalt chromium alloy (CoCr ASTM F75, 1–5 micron) wear particles. PBMC were allowed to transit the endothelium and harvested cells were analyzed for MGC generation via flow cytometry. An increase in forward scatter (cell size) and in the propidium iodide (PI) uptake (DNA intercalating dye) was used to identify MGCs. Our results show that endothelial cells induce the generation of MGCs to a level 4 fold higher in 3-dimentional PTE system as compared to traditional 2-dimensional culture plates. Further characterization of MGCs showed upregulated expression of tartrate resistant alkaline phosphatase (TRAP) and dendritic cell specific transmembrane protein, (DC-STAMP), which are markers of bone degrading cells called osteoclasts. In sum, we have established a robust and relevant model to examine MGC and osteoclast formation in a tissue like environment using flow cytometry and RT-PCR. With endothelial cells help, we observed a consistent generation of metal wear particle- induced MGCs, which heralds metal on metal hip failures.  相似文献   

12.
13.
14.
15.
Pseudocapacitive materials are used for supercapacitor applications due to their exceptionally high capacitance and low cost. Good capacitive performance of the pseudocapacitive materials at high active mass loadings is vital for the development of the next generation of supercapacitor devices. This review describes recent advances in materials and nanotechnologies, which allows the development of advanced pseudocapacitive devices with high active mass. An important breakthrough is the discovery of novel dispersing and capping agents for the colloidal processing of nanoparticles. Particularly important are novel co‐dispersants that exhibit enhanced adsorption on materials of different types, such as inorganic nanoparticles, carbon nanotubes, and graphene. Conceptually new strategies are designed to fabricate coated particles. Recent innovations pave the way for the development of multifunctional redox‐active dopants‐dispersants and dopants‐oxidants to manufacture conductive polymer composites. Among the most important advances in nanotechnology is the development of template methods and heterocoagulation techniques for composite manufacturing. The progress in the design of novel surface modification techniques and materials, discovery of advanced anchoring groups, and development of liquid–liquid extraction allows agglomerate‐free processing of nanomaterials and composites. This review describes fundamental aspects of novel technologies and their applications in the manufacturing of pseudocapacitive devices for energy storage.  相似文献   

16.
The optical responses of metal nanoparticles induced by subtle variations in geometry, especially by the rounding of the edges and corners, have generated great interest at present due to the requirement of fabricating refined structures of metal nanoparticles and theoretical simulations of the real particles. We study the effect of both inner and outer edge rounding on the optical properties of gold nanobox and gold nanobox dimer with small interparticle distances by using the discrete dipole approximation method. The shift of extinction peaks, the electric field distribution, and the variation of refractive index sensitivities by changing the curvature of the inner and outer edges of gold nanobox are investigated. We demonstrate that the optical properties of nanobox are more sensitive to the outer edge rounding than the inner edge rounding. By edge rounding of two very close gold nanoboxes, the blue shift of the dipolar and the quadrupolar plasmonic resonances of nanobox dimer are shown. Comparing with the inner edge rounding of nanobox dimer, we find that rounding of the outer edges causes the larger shift of the quadrupolar mode and approximate shift of the dipole mode.  相似文献   

17.
The net charge of a folded protein is hypothesized to influence myriad biochemical processes (e.g., protein misfolding, electron transfer, molecular recognition); however, few tools exist for measuring net charge and this elusive property remains undetermined—at any pH—for nearly all proteins. This study used lysine-acetyl “protein charge ladders” and capillary electrophoresis to measure the net charge of superoxide dismutase-1 (SOD1)—whose aggregation causes amyotrophic lateral sclerosis (ALS)—as a function of coordinated metal ions and pH. The net negative charge of apo-SOD1 was similar to predicted values; however, the binding of a single Zn2 + or Cu2 + ion reduced the net negative charge by a greater magnitude than predicted (i.e., ~ 4 units, instead of 2), whereas the SOD1 protein underwent charge regulation upon binding 2–4 metal ions. From pH5 to pH8 (i.e., a range consistent with the multiple subcellular loci of SOD1), the holo-SOD1 protein underwent smaller fluctuations in net negative charge than predicted (i.e., ~ 3 units, instead of ~ 14) and did not undergo charge inversion at its isoelectric point (pI = 5.3) but remained anionic. The regulation of SOD1 net charge along its pathways of metal binding, and across solvent pH, provides insight into its metal-induced maturation and enzymatic activity (which remains diffusion-limited across pH5–8). The anionic nature of holo-SOD1 across subcellular pH suggests that ~ 45 different ALS-linked mutations to SOD1 will reduce its net negative charge regardless of subcellular localization.  相似文献   

18.

Purpose

To compare and combine dual-energy based and iterative metal artefact reduction on hip prosthesis and dental implants in CT.

Material and Methods

A total of 46 patients (women:50%,mean age:63±15years) with dental implants or hip prostheses (n = 30/20) were included and examined with a second-generation Dual Source Scanner. 120kV equivalent mixed-images were derived from reconstructions of the 100/Sn140kV source images using no metal artefact reduction (NOMAR) and iterative metal artefact reduction (IMAR). We then generated monoenergetic extrapolations at 130keV from source images without IMAR (DEMAR) or from source images with IMAR, (IMAR+DEMAR). The degree of metal artefact was quantified for NOMAR, IMAR, DEMAR and IMAR+DEMAR using a Fourier-based method and subjectively rated on a five point Likert scale by two independent readers.

Results

In subjects with hip prosthesis, DEMAR and IMAR resulted in significantly reduced artefacts compared to standard reconstructions (33% vs. 56%; for DEMAR and IMAR; respectively, p<0.005), but the degree of artefact reduction was significantly higher for IMAR (all p<0.005). In contrast, in subjects with dental implants only IMAR showed a significant reduction of artefacts whereas DEMAR did not (71%, vs. 8% p<0.01 and p = 0.1; respectively). Furthermore, the combination of IMAR with DEMAR resulted in additionally reduced artefacts (Hip prosthesis: 47%, dental implants 18%; both p<0.0001).

Conclusion

IMAR allows for significantly higher reduction of metal artefacts caused by hip prostheses and dental implants, compared to a dual energy based method. The combination of DE-source images with IMAR and subsequent monoenergetic extrapolation provides an incremental benefit compared to both single methods.  相似文献   

19.
Raised levels of cobalt and chromium are found in the blood and urine of patients with metallic total hip replacements. When one of the hip components is made of polyethylene much less metal seems to be released from the joint. The long-term effects of the accumulation of chromium in the body need to be studied further.  相似文献   

20.
The production of highly efficient single‐ and multijunction metal halide perovskite (MHP) solar cells requires careful optimization of the optical and electrical properties of these devices. Here, precise control of CH3NH3PbI3 perovskite layers is demonstrated in solar cell devices through the use of dual source coevaporation. Light absorption and device performance are tracked for incorporated MHP films ranging from ≈67 nm to ≈1.4 µm thickness and transfer‐matrix optical modeling is utilized to quantify optical losses that arise from interference effects. Based on these results, a device with 19.2% steady‐state power conversion efficiency is achieved through incorporation of a perovskite film with near‐optimum predicted thickness (≈709 nm). Significantly, a clear signature of photon reabsorption is observed in perovskite films that have the same thickness (≈709 nm) as in the optimized device. Despite the positive effect of photon recycling associated with photon reabsorption, devices with thicker (>750 nm) MHP layers exhibit poor performance owing to competing nonradiative charge recombination in a “dead‐volume” of MHP. Overall, these findings demonstrate the need for fine control over MHP thickness to achieve the highest efficiency cells, and accurate consideration of photon reabsorption, optical interference, and charge transport properties.  相似文献   