首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Transected flexor tendons are typically treated by suture repair followed by rehabilitation that generates repetitive tendon loading. Recent results in an in vivo canine model indicate that during the first 10 days after injury and repair, there is an increase in the rigidity of the tendon repair site. Our objective was to determine whether or not ex vivo cyclic loading of repaired flexor tendons causes a similar increase in repair-site rigidity. We simulated 10 days of rehabilitation by applying 6000 loading cycles to repaired canine flexor tendons ex vivo at force levels generated during passive motion rehabilitation; we then evaluated their tensile mechanical properties. High-force (peak force, 17 N) cyclic loading increased repair-site rigidity by 100% and decreased repair-site strain by 50%, whereas low-force (5 N) loading did not change the properties of the repair site. This mechanical conditioning effect may explain, in part, the changes in tensile properties observed after only 10 days of healing in vivo. Mechanical conditioning of repaired flexor tendons by repetitive forces applied during rehabilitation may lead to increases in repair-site rigidity and decreases in strain, thereby altering the mechanical loading environment of tissues and cells at the repair site.  相似文献   

2.
This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4–0 or 3–0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand repairs by 21% when 4–0, and 33% when 3–0 suture was used, and caused a shift in failure mode from suture pullout to suture breakage. 8-strand repairs with half hitch loops but without a terminal knot produced equivalent mechanical properties to those without half hitch loops but with a terminal knot. 4-strand repairs were limited by the strength of the suture in all groups and, as a result, the presence of half hitch loops did not alter the mechanical properties. Overall, half hitch loops improved repair mechanics, allowing failure strength to reach the full capability of suture strength. Improving the mechanical properties of flexor tendon repair with half hitch loops has the potential to reduce the postoperative risk of gap formation and catastrophic rupture in the early postoperative period.  相似文献   

3.
The technique of surgical repair for zone two flexor tendon injuries has been debated extensively throughout the years, yet adhesion formation, suture rupture, and suture locking on the pulley edge remain possible consequences of a poor repair. The partially lacerated tendon is especially challenging to treat since there can be justification for not intervening surgically. In a partial laceration canine model we measured failure load and suture gap formation for tendons repaired with the Lee, modified four-strand Savage, Kessler, modified Kessler, and Augmented Becker core suture techniques and with a simple running peripheral suture. The modified Kessler (106.3 N, SD 18.8 N) and modified Savage (108.2 N, SD 19.9 N) repair techniques had a significantly higher failure load than the Lee (85.0 N, SD 20.6 N) suture method (P < 0.05), while there were no differences among the other techniques. There were no significant differences in resistance to gap formation among the repair techniques, with the mean values ranging from 38.9 N/mm (SD 15.7 N/mm) using the simple running suture to 53.2 N/mm (SD 25.8 N/mm) with the Kessler repair. The mean load to produce a 1.5 mm repair site gap ranged from 71.1 N (SD 21.5 N) in the Lee repair to 91.3 N (SD 22.2 N) in the Augmented Becker repair although there were no significant differences among repair methods. All repair methods were much weaker than tendons left unrepaired (184.7 N, SD 41.3 N).  相似文献   

4.
Active mobilization of repaired flexor tendons requires sufficient suture strength. This study was designed to investigate the suitability of four newly developed and comparatively strong tendon sutures for flexor tendon repair with active digital mobilization. Fifty fresh flexor digitorum profundus tendons were randomly assigned to five groups and repaired using the Tang, cruciate, Robertson, Silfverskiold, and modified Kessler suture methods. The repaired tendons were subjected to mechanical testing in an Instron tensile machine to determine the 2-mm gap formation force, ultimate strength, elastic modulus, and energy to failure of the sutures. The 2-mm gap formation forces of the sutures were 43.0 N for the Tang, 37.4 N for the cruciate, 25.0 N for the Robertson, 32.3 N for the Silfverskiold, and 21.2 N for the modified Kessler methods. The ultimate strength of the sutures was 53.6 N for the Tang, 46.3 N for the cruciate, 41.6 N for the Robertson, 41.0 N for the Silfverskiold, and 24.7 N for the modified Kessler methods. Statistically, the gap formation force and ultimate strength were the highest in the Tang, higher in the cruciate, and the lowest for the Robertson and the modified Kessler methods. The elastic modulus of the repaired tendons, as represented by the linear slope of the force-displacement curve, was also statistically the largest in the Tang, larger in the cruciate, and lowest for the Robertson and modified Kessler methods. Energy to failure was statistically the largest in the Tang, higher in the cruciate, lower in the Silfverskiold and the Robertson, and the lowest for the modified Kessler methods. It was concluded that significant differences exist in mechanical properties of the newly developed tendon suture methods. Among the methods for tendon repair that were tested, the Tang and the cruciate sutures were the best candidates for flexor tendon repair in the hand with postoperative active mobilization because of their superior tensile strength, elastic properties, energy to failure, and reasonable operation time.  相似文献   

5.
Following surgical Achilles tendon reconstruction surgery, there is a distinct trend towards an early and faster rehabilitation protocol to avoid muscle atrophy. However, this procedure involves the risk of a higher complication rate. In order to reduce the occurrence of re-ruptures and pathological tendon extensions, a tendon reconstruction with the highest possible primary stability is desirable. Therefore, the aim of this study was to determine if augmentation using synthetic polyester tapes (QuadsTape™) could provide greater primary stability in case of different tendon suture techniques.90 tendons of the superficial toe flexor of pigs were divided into 9 groups. The reconstruction method was combined using the factors suture technique (Kessler and Bunnell), augmentation (non-augmented and augmented with QuadsTape™) and defect type (end-to-end and 10 mm gap). The biomechanical measurements were performed on a material testing machine and consisted of a creep test, a cyclic test and a tear-off test. This study compared creep strain, ultimate load failure, maximum stress and stiffness.Irrespective of the type of defect involved, augmentation of the tendon sutures led to a significant increase of the maximum force (not augmented: 82.30 ± 25.48 N, augmented: 135.73 ± 30.69 N, p < 0.001) and the maximum stress (not augmented: 2.26 ± 0.83 MPa, augmented: 4.13 ± 1.79 MPa, p < 0.001). Furthermore, there was a non-significant increase in stiffness and no significant differences were observed with respect to creep strain.Augmentation of Achilles tendon reconstruction using QuadsTape™ increases composite strength and stiffness in the in vitro model, thus potentially contributing to the feasibility of early rehabilitation programs. Biological factors still need to be investigated in order to formulate appropriate indications.  相似文献   

6.
The aim of this article is to present two new techniques for digital flexor tendon repair: a modification to the conventional Kessler technique (wrap core suture) and tendon splints (H-shaped splint). These techniques were aimed at enhancing the biomechanical properties of such repairs as related to resistance to both gap formation and repair failure. Comparing (in an ex vivo study) the tensiometric properties (gap formation and failure strengths) of 24 flexor digitorum profundus tendons repaired with the described techniques (12 repairs per each technique) and the conventional Kessler repair (24 repairs), we found that the former provided significantly stronger repairs than the latter in vitro. A statistically significant difference (p < 0.001) was found between each of the two presented techniques and the Kessler repair. The wrap core suture increased the load at which a visible (1 mm) gap formed by 22.6 percent when compared with the conventional Kessler suture. The mean gap strength of the wrap core repair was 6.5 N, whereas that of the conventional Kessler was 5.3 N. The failure loads (ultimate strength) of the wrap core suture were 33.8 percent higher than those of the conventional Kessler. The mean breaking load of the wrap core repair was 19.4 N, whereas that of the conventional Kessler was 14.5 N. The H-splint repair increased the load at which a visible gap formed and the failure loads (ultimate strength) by 158.5 and 333.1 percent, respectively, when compared with the conventional Kessler suture. The mean gap strength of the H-splint repair was 13.7 N, and its mean breaking load was 62.8 N.  相似文献   

7.
An increasing number of tissue banks have begun to focus on gamma irradiation and freeze-thaw in the reconstruction of anterior cruciate ligaments using allografts. The purpose of this study was to evaluate the biomechanical properties of human tendons after exposure to gamma radiation and repeated freeze-thaw cycles and to compare them with fresh specimens. Forty flexor digitorum superficialis tendons were surgically procured from five fresh cadavers and divided into four groups: fresh tendon, gamma irradiation, freeze-thaw and gamma irradiation+freeze-thaw. The dose of gamma irradiation was 25 kGy. Each freeze-thaw cycle consisted of freezing at -80 °C for 7 day and thawing at 25 °C for 6 h. These tendons underwent 4 freeze-thaw cycles. Biomechanical properties were analyzed during load-to-failure testing. The fresh tendons were found to be significantly different in ultimate load, stiffness and ultimate stress relative to the other three groups. The tendons of the gamma+freeze-thaw group showed a significant decrease in ultimate load, ultimate stress and stiffness compared with the other three groups. Gamma irradiation and repeated freezing-thawing (4 cycles) can change the biomechanical properties. However, no significant difference was found between these two processes on the effect of biomechanical properties. It is recommended that gamma irradiation (25 kGy) and repetitive freeze-thaw cycles (4 cycles) should not be adopted in the processing of the allograft tendons.  相似文献   

8.
Trauma by suturing tendon form areas devoid of cells termed “acellular zones” in the matrix. This study aimed to characterise the cellular insult of suturing and acellular zone formation in mouse tendon. Acellular zone formation was evaluated using single grasping sutures placed using flexor tendons with time lapse cell viability imaging for a period of 12 h. Both tension and injury were required to induce cell death and cell movement in the formation of the acellular zone. DNA fragmentation studies and transmission electron microscopy indicated that cells necrosed.Parallel in vivo studies showed that cell-to-cell contacts were disrupted following grasping by the suture in tensioned tendon. Without tension, cell death was lessened and cell-to-cell contacts remained intact. Quantitative immunohistochemistry and 3D cellular profile mapping of wound healing markers over a one year time course showed that acellular zones arise rapidly and showed no evidence of healing whilst the wound healing response occurred in the surrounding tissues. The acellular zones were also evident in a standard modified “Kessler” clinical repair. In conclusion, the suture repair of injured tendons produces acellular zones, which may potentially cause early tendon failure.  相似文献   

9.
Resistance forces acting on suture needles   总被引:2,自引:0,他引:2  
Understanding the resistance forces encountered by a suture needle during tissue penetration is important for the development of robotic surgical devices and virtual reality surgical simulators. Tensile forces applied to skin and tendon during suturing were measured. Fresh sheep achilles tendons were tensioned with a static load 4.9 N, 9.8 N or 19.6 N and sheepskin with 0.98 N, 2.9 N or 4.9 N static load. A straight 2/0 cutting suture needle in series with a load cell on a materials testing machine penetrated the tissue at 90 degrees with a velocity of 1, 5 or 10mm/s for each tissue tension (n=5). Continuous load versus displacement data was obtained and penetration load and stiffness were noted. The load versus displacement curve for skin during needle penetration demonstrated two characteristic peaks, corresponding to initial penetration and emergence of needle from the undersurface of the tissue. Increasing the tension within the tissue (skin and tendon) increased the amount of force required to penetrate the tissue with a suture needle (p<0.05). Needle displacement rate did not affect the resistance to needle penetration (p<0.05). This study provides a simple model for measuring force-feedback during needle penetration of soft tissues and is a good starting point for future studies of the penetration resistance properties of human tissues.  相似文献   

10.
Flexor tendon repair in zone II is complicated by adhesions that impair normal postoperative gliding. Transforming growth factor-beta (TGF-beta) is a family of growth factors that has been implicated in scar formation. The TGF-beta family of proteins binds to three distinct classes of membrane receptors, termed RI, RII, and RIII. In this study, we analyzed the temporal and spatial distribution of TGF-beta receptor isoforms (RI, RII, and RIII) in a rabbit zone II flexor tendon wound healing model.Twenty-eight adult New Zealand White rabbit forepaws underwent isolation of the middle digit flexor digitorum profundus tendon in zone II. The tendons underwent transection in zone II and immediate repair. The tendons were harvested at increasing time points: 1, 3, 7, 14, 28, and 56 days postoperatively (n = 4 at each time point). The control flexor tendons were harvested without transection and repair (n = 4). Immunohistochemical analysis was used to detect the expression patterns for TGF-beta receptors RI, RII, and RIII.Immunohistochemical staining of the transected and repaired tendons demonstrated up-regulation of TGF-beta RI, RII, and RIII protein levels. TGF-beta receptor production in the experimental group (transection and repair) was concentrated in the epitenon and along the repair site. Furthermore, the TGF-beta receptor expression levels peaked at day 14 and decreased by day 56 postoperatively. In contrast, minimal receptor expression was observed in the untransected and unrepaired control tendons.These data provide evidence that (1) TGF-beta receptors are up-regulated after injury and repair; (2) peak levels of TGF-beta receptor expression occurred at day 14 and decreased by day 56 after wounding and repair; and (3) both the tendon sheath and epitenon have the highest receptor expression, and both may play critical roles in flexor tendon wound healing. Understanding the up-regulation of TGF-beta isoforms and the up-regulation of their corresponding receptors during flexor tendon wound healing provides new targets for biomolecular modulation of postoperative scar formation.  相似文献   

11.
Terminal sterilization of tendon allografts with high dose gamma irradiation has deleterious effects on tendon mechanical properties and stability after implantation. Our goal is to minimize these effects with radio protective methods. We previously showed that radio protection via combined crosslinking and free radical scavenging maintained initial mechanical properties of tendon allografts after irradiation at 50 kGy. This study further evaluates the tissue response and simulated mechanical degradation of tendons processed with radio protective treatment, which involves crosslinking in 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide followed by soaking in an ascorbate/riboflavin-5-phosphate solution. Control untreated and treated tendons were irradiated at 50 kGy and implanted in New Zealand White rabbit knees within the joint capsule for four and 8 weeks. Tendons were also exposed to cyclic loading to 20 N at one cycle per 12 s in a collagenase solution for 150 cycles, followed by tension to failure. Control irradiated tendons displayed increased degradation in vivo, and failed prematurely during cyclic processing at an average of 25 cycles. In contrast, radio protected irradiated tendons displayed greater stability following implantation over 8 weeks, and possessed strength at 59 % of native tendons and modulus equivalent to that of native tendons after cyclic loading in collagenase. These results suggest that radio protective treatment improves the strength and the stability of tendon allografts.  相似文献   

12.
Tendon or ligament reconstructions often use autologous or allogenic tendons from either extrasynovial or intrasynovial sources. Allograft tendons must be lyophilized for preservation before transplantation, a process which can impact mechanical properties of the graft. Reconstituted graft properties that are similar to native tendon are desirable. Although tensile and compressive properties of tendons have been investigated, there is a paucity of information describing flexural properties of tendon, which can impact the gliding resistance. This study aims to design a testing method to quantify tendon flexural modulus, and investigate the effects of lyophilization/rehydration procedures on tendon flexibility. A total of 20 peroneus longus tendons (extrasynovial) and 20 flexor digitorum profundus tendons (intrasynovial) were collected. Ten of each tendon were processed with 5 freeze–thaw cycles followed by lyophilization and rehydration with saline solution (0.9%). Bend testing was conducted on tendons to quantify the flexural modulus with and without processing. As canine FDP tendons contain fibrous and fibrocartilaginous tissue regions, the flexural moduli were measured in both regions. Flexural modulus of rehydrated, lyophilized extrasynovial PL tendon was significantly lower than that of similarly processed intrasynovial FDP tendon (p < 0.001). Flexural moduli of both the fibrocartilaginous and non-fibrocartilaginous regions of intrasynovial tendon significantly increased after lyophilization (p < 0.001). The flexural modulus of the fibrocartilaginous region was significantly higher than that of the non-fibrocartilaginous region in intrasynovial tendon (p < 0.001). Lyophilization significantly increases the flexural modulus of extrasynovial and intrasynovial tendons, and flexural modulus differs significantly between these two tendon types. Increases in stiffness caused by lyophilization may impact the mechanical performance of the allograft in vivo.  相似文献   

13.
Measurements of in-vitro carpal kinematics of the wrist provide valuable biomechanical data. Tendon loading is often applied during cadaver experiments to simulate natural stabilizing joint compression in the wrist joint. The purpose of this study was to investigate the effect of tendon loading on carpal kinematics in-vitro.A cyclic movement was imposed on 7 cadaveric forearms while the carpal kinematics were acquired by a 4-dimensional rotational X-ray imaging system. The extensor- and flexor tendons were loaded with constant force springs of 50 N, respectively. The measurements were repeated without a load on the tendons. The effect of loading on the kinematics was tested statistically by using a linear mixed model.During flexion and extension, the proximal carpal bones were more extended with tendon loading. The lunate was on the average 2.0° (p=0.012) more extended. With tendon loading the distal carpal bones were more ulnary deviated at each angle of wrist motion. The capitate was on the average 2.4° (p=0.004) more ulnary deviated.During radioulnar deviation, the proximal carpal bones were more radially deviated with the lunate 0.7° more into radial deviation with tendon loading (p<0.001). Conversely, the bones of distal row were more flexed and supinated with the capitate 1.5° more into flexion (p=0.025) and 1.0° more into supination (p=0.011).In conclusion, the application of a constant load onto the flexor and extensor tendons in cadaver experiments has a small but statistically significant effect on the carpal kinematics during flexion–extension and radioulnar deviation.  相似文献   

14.
Flexor tendon injuries are a common clinical problem, and repairs are frequently complicated by post-operative adhesions forming between the tendon and surrounding soft tissue. Prostaglandin E2 and the EP4 receptor have been implicated in this process following tendon injury; thus, we hypothesized that inhibiting EP4 after tendon injury would attenuate adhesion formation. A model of flexor tendon laceration and repair was utilized in C57BL/6J female mice to evaluate the effects of EP4 inhibition on adhesion formation and matrix deposition during flexor tendon repair. Systemic EP4 antagonist or vehicle control was given by intraperitoneal injection during the late proliferative phase of healing, and outcomes were analyzed for range of motion, biomechanics, histology, and genetic changes. Repairs treated with an EP4 antagonist demonstrated significant decreases in range of motion with increased resistance to gliding within the first three weeks after injury, suggesting greater adhesion formation. Histologic analysis of the repair site revealed a more robust granulation zone in the EP4 antagonist treated repairs, with early polarization for type III collagen by picrosirius red staining, findings consistent with functional outcomes. RT-PCR analysis demonstrated accelerated peaks in F4/80 and type III collagen (Col3a1) expression in the antagonist group, along with decreases in type I collagen (Col1a1). Mmp9 expression was significantly increased after discontinuing the antagonist, consistent with its role in mediating adhesion formation. Mmp2, which contributes to repair site remodeling, increases steadily between 10 and 28 days post-repair in the EP4 antagonist group, consistent with the increased matrix and granulation zones requiring remodeling in these repairs. These findings suggest that systemic EP4 antagonism leads to increased adhesion formation and matrix deposition during flexor tendon healing. Counter to our hypothesis that EP4 antagonism would improve the healing phenotype, these results highlight the complex role of EP4 signaling during tendon repair.  相似文献   

15.
For testing of fixation devices such as suture anchors used in rotator cuff repair often animal bones are used. They are easily obtained, inexpensive and some have been found to be similar to human bone. But can we rely on the results drawn from these studies in our daily surgical practice?The purpose of this study was to compare the trabecular bone mineral density, the trabecular bone volume fraction and the cortical layer thickness in the greater tubercle in different species to evaluate their influence on primary stability of suture anchors under a cyclic loading protocol representing the physiologic forces placed on rotator cuff repairs in vivo.Bovine and ovine humeri are not suitable for suture anchor testing. The statistical significances for pullout forces between the anchors varied from species to species. Therefore, no very applicable information can be obtained from testing suture anchors in ovine or bovine humeri with regard to ultimate failure loads in human humeri. The ultimate failure load seems to depend mainly on the cortical thickness and on the subcortical trabecular bone quality.  相似文献   

16.
A non-invasive ultrasonic (US) technique of tendon force measurement has been recently developed. It is based on the relationship demonstrated between the speed of sound (SOS) in a tendon and the traction force applied to it. The objectives of the present study were to evaluate the variability of this non-linear relationship among 7 equine superficial digital flexor (SDF) tendons, and the reproducibility of SOS measurements in these tendons over successive loading cycles and tests. Seven SDF tendons were equipped with an US probe (1 MHz), secured in contact with the skin overlying the tendon metacarpal part. The tendons were submitted to a traction test consisting in 5 cycles of loading/unloading between 50 and 4050 N. Four tendons out of the 7 were submitted to 5 additional cycles up to 5550 N. The SOS-tendon force relationships appeared similar in shape, although large differences in SOS levels were observed among the tendons. Reproducibility between cycles was evaluated from the root mean square of the standard deviations (RMS-SD) of SOS values observed every 100 N, and of force values every 2 m/s. Reproducibility of SOS measurements revealed high between successive cycles: above 500 N the RMS-SD was less than 2% of the corresponding traction force. Reproducibility between tests was lower, partly due to the experimental set-up; above 500 N the difference between the two tests stayed nevertheless below 15% of the corresponding mean traction force. The reproducibility of the US technique here demonstrated in vitro has now to be confirmed in vivo.  相似文献   

17.
The force and excursion within the canine digital flexor tendons were measured during passive joint manipulations that simulate those used during rehabilitation after flexor tendon repair and during active muscle contraction, simulating the active rehabilitation protocol. Tendon force was measured using a small buckle placed upon the tendon while excursion was measured using a suture marker and video analysis method. Passive finger motion imposed with the wrist flexed resulted in dramatically lower tendon force (approximately 5 N) compared to passive motion imposed with the wrist extended (approximately 17 N). Lower excursions were seen at the level of the proximal interphalangeal joint with the wrist flexed (approximately 1.5 mm) while high excursion was observed when the wrist was extended or when synergistic finger and wrist motion were imposed (approximately 3.5 mm). Bivariate discriminant analysis of both force and excursion data revealed a natural clustering of the data into three general mechanical paradigms. With the wrist extended and with either one finger or four fingers manipulated, tendons experienced high loads of approximately 1500 g and high excursions of approximately 3.5 mm. In contrast, the same manipulations performed with the wrist flexed resulted in low tendon forces (4-8 N) and low tendon excursions of approximately 1.5 mm. Synergistic wrist and finger manipulation provided the third paradigm where tendon force was relatively low (approximately 4 N) but excursion was as high as those seen in the groups which were manipulated with the wrist extended. Active muscle contraction produced a modest tendon excursion (approximately 1 mm) and high or low tendon force with the wrist extended or flexed, respectively. These data provide the basis for experimentally testable hypotheses with regard to the factors that most significantly affect functional recovery after digital flexor tendon injury and define the normal mechanical operating characteristics of these tendons.  相似文献   

18.
Minimising post-operative donor site morbidity is an important consideration when selecting a graft for surgical reconstruction of the torn anterior cruciate ligament (ACL). One of the most common procedures, the bone-patellar tendon-bone (BPTB) graft involves removal of the central third from the tendon. However, it is unknown whether the mechanical properties of the donor site (patellar tendon) recover. The present study investigated the mechanical properties of the human patellar tendon in 12 males (mean±S.D. age: 37±14 years) who had undergone surgical reconstruction of the ACL using a BPTB graft between 1 and 10 years before the study (operated knee; OP). The uninjured contralateral knee served as a control (CTRL). Patellar tendon mechanical properties were assessed in vivo combining dynamometry with ultrasound imaging. Patellar tendon stiffness was calculated from the gradient of the tendon's force–elongation curve. Tendon stiffness was normalised to the tendon's dimensions to obtain the tendon's Young's modulus. Cross-sectional area (CSA) of OP patellar tendons was larger by 21% than CTRL tendons (P<0.01). Patellar tendon stiffness was not significantly different between OP and CTRL tendons, but the Young's modulus was lower by 24% in OP tendons (P<0.01). A compensatory enlargement of the patellar tendon CSA, presumably due to scar tissue formation, enabled a recovery of tendon stiffness in the OP tendons. The newly formed tendon tissue had inferior properties as indicated by the reduced tendon Young's modulus, but it increased to a level that enabled recovery of tendon stiffness.  相似文献   

19.
The locking loop tendon suture is suggested as an effective method for suturing tendons where tension is likely during the early post-operative period. The relationship of the intratendinous parts of the suture to each other is critical to the resultant tensile strength. Experimental work has confirmed its strength and its lack of interference with the intrinsic vasculature of the tendons. Our results from this clinical repair of 72 tendons by this method have been better, in general, than we obtained with other currently popular methods.  相似文献   

20.
Extensive clinical and laboratory studies have demonstrated that growth factors accelerate and modulate the wound-healing process. The purpose of this experiment was to apply the principles of growth factor-enhanced wound healing to an in vitro rat tendon model. A method was developed for covalently binding a biologically active peptide to nonabsorbable braided polyester suture (Mersilene). Sutures were treated with various growth factors, which included epidermal growth factor, platelet-derived growth factor, and keratinocyte growth factor, and bovine serum albumin was the control. Spectrophotometric assessment was used to verify the peptide's activity. The suture was subsequently placed through individual harvested rat flexor tendons, which were arranged in standard tissue culture conditions. Markedly increased cellular proliferation along the suture was appreciated on the tendons treated with epidermal growth factor-bound suture. Platelet-derived growth factor was shown to have a lesser effect, whereas keratinocyte growth factor had no visible effect on cellular proliferation. This preliminary study describes a new technique of binding growth factors to suture. It also demonstrates that the presence of growth factors may help facilitate flexor tendon healing and allow early postoperative rehabilitation to decrease adhesion formation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号