首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and their quality of life. In the present study, 9 persons with unilateral transtibial amputation and 13 able-bodied controls walked on a large treadmill in a Computer Assisted Rehabilitation Environment (CAREN). While walking, subjects were either not perturbed, or were perturbed either by continuous mediolateral platform movements or by continuous mediolateral movements of the visual scene. Means and standard deviations of both step lengths and step widths increased significantly during both perturbation conditions (all p<0.001) for both groups. Measures of variability, local and orbital dynamic stability of trunk movements likewise exhibited large and highly significant increases during both perturbation conditions (all p<0.001) for both groups. Patients with amputation exhibited greater step width variability (p=0.01) and greater trunk movement variability (p=0.04) during platform perturbations, but did not exhibit greater local or orbital instability than healthy controls for either perturbation conditions. Our findings suggest that, in the absence of other co-morbidities, patients with unilateral transtibial amputation appear to retain sufficient sensory and motor function to maintain overall upper body stability during walking, even when substantially challenged. Additionally, these patients did not appear to rely more heavily on visual feedback to maintain trunk stability during these walking tasks.  相似文献   

2.
Understanding how humans maintain stability when walking, particularly when exposed to perturbations, is key to preventing falls. Here, we quantified how imposing continuous, pseudorandom anterior-posterior (AP) and mediolateral (ML) oscillations affected the control of dynamic walking stability. Twelve subjects completed five 3-minute walking trials in the Computer Assisted Rehabilitation ENvironment (CAREN) system under each of 5 conditions: no perturbation (NOP), AP platform (APP) or visual (APV) or ML platform (MLP) or visual (MLV) oscillations. We computed AP and ML margins of stability (MOS) for each trial. Mean MOS(ml) were consistently slightly larger during all perturbation conditions than during NOP (p≤0.038). Mean MOS(ap) for the APP, MLP and MLV oscillations were significantly smaller than during NOP (p<0.0005). Variability of both MOS(ap) and MOS(ml) was significantly greater during the MLP and MLV oscillations than during NOP (p<0.0005). We also directly quantified how the MOS on any given step affected the MOS on the following step using first-return plots. There were significant changes in step-to-step MOS(ml) dynamics between experimental conditions (p<0.0005). These changes suggested that subjects may have been trying to control foot placement, and consequently stability, during the perturbation conditions. Quantifying step-to-step changes in margins of dynamic stability may be more useful than mean MOS in assessing how individuals control walking stability.  相似文献   

3.
Understanding how lower-limb amputation affects walking stability, specifically in destabilizing environments, is essential for developing effective interventions to prevent falls. This study quantified mediolateral margins of stability (MOS) and MOS sub-components in young individuals with traumatic unilateral transtibial amputation (TTA) and young able-bodied individuals (AB). Thirteen AB and nine TTA completed five 3-min walking trials in a Computer Assisted Rehabilitation ENvironment (CAREN) system under each of three test conditions: no perturbations, pseudo-random mediolateral translations of the platform, and pseudo-random mediolateral translations of the visual field. Compared to the unperturbed trials, TTA exhibited increased mean MOS and MOS variability during platform and visual field perturbations (p<0.010). AB exhibited increased mean MOS during visual field perturbations and increased MOS variability during both platform and visual field perturbations (p<0.050). During platform perturbations, TTA exhibited significantly greater values than AB for mean MOS (p<0.050) and MOS variability (p<0.050); variability of the lateral distance between the center of mass (COM) and base of support at initial contact (p<0.005); mean and variability of the range of COM motion (p<0.010); and variability of COM peak velocity (p<0.050). As determined by mean MOS and MOS variability, young and otherwise healthy individuals with transtibial amputation achieved lateral stability similar to that of their able-bodied counterparts during unperturbed and visually-perturbed walking. However, based on mean and variability of MOS, unilateral transtibial amputation was shown to have affected lateral walking stability during platform perturbations.  相似文献   

4.
Obesity in older adults is a growing public health problem. Excess weight causes biomechanical burden to lower extremity joints and contribute to joint pathology. The aim of this study was to identify specific characteristics of gait associated with body mass index (BMI). Preferred and maximum speed walking and related gait characteristics were examined in 164 (50–84 years) participants from Baltimore Longitudinal Study of Aging (BLSA) able to walk unassisted. Participants were divided into three groups based on their BMI: normal weight (19≤BMI<25 kg/m2), overweight (25≤BMI<30 kg/m2) and obese (BMI 30≤BMI<40 kg/m2). Total ankle generative mechanical work expenditure (MWE) in the anterior–posterior (AP) plane was progressively and significantly lower with increase in BMI for both preferred (p=0.026) and maximum speed walking (p<0.001). In the medial–lateral (ML) plane, total knee generative MWE was higher in obese participants in the preferred speed task (p=0.002), and total hip absorptive MWE was higher in obese in both preferred speed (p<0.001) and maximum speed (p=0.002) walking task compared to the normal weight participants. Older adults with obesity show spatiotemporal gait patterns that may help in reducing contact impacts. In addition, in obese persons mechanical energy usages tend to be lower in the AP plane and higher in the ML plane. Since forward progression forces are mainly implicated in normal walking, this pattern found in obese participants is suggestive of lower energetic efficiency.  相似文献   

5.
The aim of this cross-sectional study was to delineate age-associated kinematic and kinetic gait patterns of normal walking, and to test the hypothesis that older adults exhibit gait patterns that reduce generative mechanical work expenditures (MWEs). We studied 52 adult Baltimore Longitudinal Study of Aging participants (means age 72±9, from 60 to 92 years) who could walk 4 m unaided. Three-dimensional kinematic and kinetic parameters assessed during rotation-defined gait periods were used to estimate MWEs for the rotation of lower extremities about the medial–lateral (ML) and anterior–posterior (AP) axes of proximal joints, which represent MWEs in the AP and ML sides, respectively. Relationships between gait parameters and age were examined using regression analysis with adjustments for walking speed, sex, height, and weight. Older age was associated with slower self-selected walking speed (p<0.001), shorter stride length (p<0.001), and greater propensity of landing flat-footed (p=0.003). With older age, hip generative MWE for thigh rotation was lower about the AP axis (hip abduction and adduction) during stance (p=0.010) and higher about the ML axis (hip extension and flexion) during late stance (p<0.001). Knee absorptive MWE for shank rotation about the AP axis (knee abduction and adduction) during early stance was also lower with older age (p<0.003). These age-related gait patterns may represent a compensatory effort to maintain balance and may also reflect mobility limitations.  相似文献   

6.
In gait stability research, neither self-selected walking speeds, nor the same prescribed walking speed for all participants, guarantee equivalent gait stability among participants. Furthermore, these options may differentially affect the response to different gait perturbations, which is problematic when comparing groups with different capacities. We present a method for decreasing inter-individual differences in gait stability by adjusting walking speed to equivalent margins of stability (MoS). Eighteen healthy adults walked on a split-belt treadmill for two-minute bouts at 0.4 m/s up to 1.8 m/s in 0.2 m/s intervals. The stability-normalised walking speed (MoS = 0.05 m) was calculated using the mean MoS at touchdown of the final 10 steps of each speed. Participants then walked for three minutes at this speed and were subsequently exposed to a treadmill belt acceleration perturbation. A further 12 healthy adults were exposed to the same perturbation while walking at 1.3 m/s: the average of the previous group. Large ranges in MoS were observed during the prescribed speeds (6–10 cm across speeds) and walking speed significantly (P < 0.001) affected MoS. The stability-normalised walking speeds resulted in MoS equal or very close to the desired 0.05 m and reduced between-participant variability in MoS. The second group of participants walking at 1.3 m/s had greater inter-individual variation in MoS during both unperturbed and perturbed walking compared to 12 sex, height and leg length-matched participants from the stability-normalised walking speed group. The current method decreases inter-individual differences in gait stability which may benefit gait perturbation and stability research, in particular studies on populations with different locomotor capacities. [Preprint: https://doi.org/10.1101/314757]  相似文献   

7.
During human walking, plantar flexor activation in late stance helps to generate a stable and economical gait pattern. Because plantar flexor activation is highly mediated by proprioceptive feedback, the nervous system must modulate reflex pathways to meet the mechanical requirements of gait. The purpose of this study was to quantify ankle joint mechanical output of the plantar flexor stretch reflex response during a novel unexpected gait perturbation. We used a robotic ankle exoskeleton to mechanically amplify the ankle torque output resulting from soleus muscle activation. We recorded lower-body kinematics, ground reaction forces, and electromyography during steady-state walking and during randomly perturbed steps when the exoskeleton assistance was unexpectedly turned off. We also measured soleus Hoffmann- (H-) reflexes at late stance during the two conditions. Subjects reacted to the unexpectedly decreased exoskeleton assistance by greatly increasing soleus muscle activity about 60 ms after ankle angle deviated from the control condition (p<0.001). There were large differences in ankle kinematic and electromyography patterns for the perturbed and control steps, but the total ankle moment was almost identical for the two conditions (p=0.13). The ratio of soleus H-reflex amplitude to background electromyography was not significantly different between the two conditions (p=0.4). This is the first study to show that the nervous system chooses reflex responses during human walking such that invariant ankle joint moment patterns are maintained during perturbations. Our findings are particularly useful for the development of neuromusculoskeletal computer simulations of human walking that need to adjust reflex gains appropriately for biomechanical analyses.  相似文献   

8.
Human walking requires active neuromuscular control to ensure stability in the lateral direction, which inflicts a certain metabolic load. The magnitude of this metabolic load has previously been investigated by means of passive external lateral stabilization via spring-like cords. In the present study, we applied this method to test two hypotheses: (1) the effect of external stabilization on energy cost depends on the stiffness of the stabilizing springs, and (2) the energy cost for balance control, and consequently the effect of external stabilization on energy cost, depends on walking speed. Fourteen healthy young adults walked on a motor driven treadmill without stabilization and with stabilization with four different spring stiffnesses (between 760 and 1820 N m−1) at three walking speeds (70%, 100%, and 130% of preferred speed). Energy cost was calculated from breath-by-breath oxygen consumption. Gait parameters (mean and variability of step width and stride length, and variability of trunk accelerations) were calculated from kinematic data. On average external stabilization led to a decrease in energy cost of 6% (p<0.005) as well as a decrease in step width (24%; p<0.001), step width variability (41%; p<0.001) and variability of medio-lateral trunk acceleration (12.5%; p<0.005). Increasing stabilizer stiffness increased the effects on both energy cost and medio-lateral gait parameters up to a stiffness of 1260 N m−1. Contrary to expectations, the effect of stabilization was independent of walking speed (p=0.111). These results show that active lateral stabilization during walking involves an energetic cost, which is independent of walking speed.  相似文献   

9.
To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities—using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (p<0.01, 95% confidence interval of Pearson?s coefficient r>0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (p>0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction.  相似文献   

10.
Perturbation training is an emerging approach to reduce fall risk in the elderly. This study examined potential differences in retention of improvements in reactive gait stability over 14 weeks resulting from unexpected trip-like gait perturbations. Twenty-four healthy middle-aged adults (41–62 years) were assigned randomly to either a single perturbation group (SINGLE, n = 9) or a group subjected to eight trip-like gait perturbations (MULTIPLE, n = 15). While participants walked on a treadmill a custom-built brake-and-release system was used to unexpectedly apply resistance during swing phase to the lower right limb via an ankle strap. The anteroposterior margin of stability (MoS) was calculated as the difference between the anterior boundary of the base of support and the extrapolated centre of mass at foot touchdown for the perturbed step and the first recovery step during the first and second (MULTIPLE group only) perturbation trials for the initial walking session and retention-test walking 14 weeks later. Group MULTIPLE retained the improvements in reactive gait stability to the perturbations (increased MoS at touchdown for perturbed and first recovery steps; p < 0.01). However, in group SINGLE no differences in MoS were detected after 14 weeks compared to the initial walking session. These findings provide evidence for the requirement of a threshold trip-perturbation dose if adaptive changes in the human neuromotor system over several months, aimed at the improvement in fall-resisting skills, are to occur.  相似文献   

11.
Several efforts have been made to study gait stability using measures derived from nonlinear time-series analysis. The maximum finite time Lyapunov exponent (λmax) quantifies how a system responds to an infinitesimally small perturbation. Recent studies suggested that slow walking leads to lower λmax values, and thus is more stable than fast walking, but these studies suffer from methodological limitations. We studied the effects of walking speed on the amount of kinematic variability and stability in human walking. Trunk motions of 15 healthy volunteers were recorded in 3D during 2 min of treadmill walking at different speeds. From those time series, maximum Lyapunov exponents, indicating short-term and long-term divergence (λS-stride and λL-stride), and mean standard deviation (MeanSD) were calculated. λS-stride showed a linear decrease with increasing speed for forward–backward (AP) movements and quadratic effects (inverted U-shaped) for medio-lateral (ML) and up–down (VT) movements. λL-stride showed a quadratic effect (inverted U-shaped) of walking speed for AP movements, a linear decrease for ML movements, and a linear increase for VT movements. Moreover, positive correlations between λS and MeanSD were found for all directions, while λL-stride and MeanSD were correlated negatively in the AP direction. The different effects of walking speed on λS-stride and λL-stride for the different planes suggest that slow walking is not necessarily more stable than fast walking. The absence of a consistent pattern of correlations between λL-stride and MeanSD over the three directions suggests that variability and stability reflect, at least to a degree, different properties of the dynamics of walking.  相似文献   

12.
Postural control is commonly investigated by observing responses to perturbations. We developed a perturbation paradigm mimicking self-generated errors in weight shifting, which are a common cause of falling among older adults. Our aim was to determine the effects of this small, but complex, perturbation on postural sway of healthy young adults and evaluate the role of vision and cognition during movement dependent perturbations. Fifteen participants stood hip-width apart with their eyes open, closed and while performing two different cognitive tasks. Participants were continuously perturbed by medial-lateral (ML) support surface translations corresponding to, and hence doubling, their own center of mass sway. We analyzed the standard deviation (SD), root mean square (RMS), range, and mean power frequency (MPF) of center of pressure displacements. ML postural sway increased due to the perturbation (SD p ≤ .001, range p < .001, RMS p ≤ .001, MPF p < .001). Cognitive load increased the ML sway range (p = .048). Lack of vision increased ML MPF (p = .001) and anterior-posterior (AP) range (p < .001), SD (p < .001), and RMS (p = .001). Significant interaction of vision with the perturbation was found for the ML range (p = .045) and AP SD (p = .018). The perturbation specifically affected ML postural sway. Increased MPF is indicative of a postural control strategy change, which was insufficient for fully controlling the increased sway. Despite being small, this type of perturbation appears to be challenging for young adults.  相似文献   

13.
Knowledge about intra-limb coordination (ILC) during challenging walking conditions provides insight into the adaptability of central nervous system (CNS) for controlling human gait. We assessed the effects of cognitive load and speed on the pattern and variability of the ILC in young people during walking. Thirty healthy young people (19 female and 11 male) participated in this study. They were asked to perform 9 walking trials on a treadmill, including walking at three paces (preferred, slower and faster) either without a cognitive task (single-task walking) or while subtracting 1?s or 3?s from a random three-digit number (simple and complex dual-task walking, respectively). Deviation phase (DP) and mean absolute relative phase (MARP) values—indicators of variability and phase dynamic of ILC, respectively—were calculated using the data collected by a motion capture system. We used a two-way repeated measure analysis of variance for statistical analysis. The results showed that cognitive load had a significant main effect on DP of right shank–foot and thigh–shank, left shank–foot and pelvis–thigh (p<0.05), and MARP of both thigh–shank segments (p<0.01). In addition, the main effect of walking speed was significant on DP of all segments in each side and MARP of both thigh–shank and pelvis–thigh segments (p<0.001). The interaction of cognitive load and walking speed was only significant for MARP values of left shank–foot and right pelvis–thigh (p<0.05 and p<0.001, respectively). We suggest that cognitive load and speed could significantly affect the ILC and variability and phase dynamic during walking.  相似文献   

14.
One of the challenges in collecting ground reaction force (GRF) and moment data for gait analysis is to obtain “good hits” when the subject walks past the forceplates. We examined whether centerline-guided walking would significantly increase the chance of good hits and alter gait characteristics. Thirty-five healthy individuals (age: 37±13 yrs) walked on a walkway with five embedded forceplates at comfortable self-selected speeds under two conditions: (1) free walking and (2) walking along a centerline and avoiding stepping on it. Gait kinematics and GRF were collected using an 8-camera optoelectronic system and five forceplates, respectively. Surface electromyographic (EMG) activity of the rectus femoris, hamstring, gastrocnemius (GAS), and tibialis anterior (TA) were monitored bilaterally. The probability of good hits significantly increased with the centerline-guided walking (p=0.008). Repeated measures MANOVA and follow-up univariate tests revealed no significant differences between the two conditions in any of the spatiotemporal parameters except for a significant increase in step width with centerline walking (p<0.001). Centerline guiding significantly increased peak mediolateral GRF (p<0.001) and hip adduction/abduction and ankle internal/external rotation ranges of motion (p<0.01). In addition, the average EMG activity in GAS and TA during the stance phase significantly increased with the centerline walking (p<0.001). In general, the centerline walking tended to impact women more than men. Centerline-guided walking increases the chance of good hits but biomechanical characteristics of gait in the frontal and transverse planes and EMG activity should be interpreted with caution, especially in women.  相似文献   

15.
External perturbations applied to the walking surface or visual field can challenge an individual's ability to maintain stability during walking. Accurately quantifying and predicting changes in stability during walking will further our understanding of how individuals respond to challenges encountered during daily life and guide the development of assessments and rehabilitation interventions for individuals at increased risk of falling. This study is the first to determine how orbital and local dynamic stability metrics, including maximum Floquet multipliers and local divergence exponents, change in response to continuous mediolateral visual and surface perturbations of different amplitudes. Eleven healthy individuals walked in a fully immersive virtual environment. Participants completed two 3-min walking trials each under the following nine conditions: no perturbations, surface perturbations at each of 3 amplitudes, and visual perturbations at each of 5 amplitudes. All perturbations were applied as continuous pseudo-random oscillations. During both surface and visual perturbations, individuals were significantly more orbitally and locally unstable compared to un-perturbed walking. As walking surface perturbation amplitudes increased, individuals were more orbitally (but not locally) unstable. As visual perturbation amplitudes increased, individuals were more locally (but not orbitally) unstable between lower and higher amplitudes. Overall, these dynamic stability metrics were much less sensitive to changes in perturbation amplitudes than to differences between un-perturbed and perturbed walking, or to differences between mechanical and visual perturbations. This suggests that the type of perturbation(s) applied has a far greater impact than the magnitude of those perturbations in determining the response that will be elicited.  相似文献   

16.
Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual) walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1–50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the lowest minimum detectable change values, supporting their use for tracking changes over multiple testing sessions. The between-session reliability and minimum detectable change values reported here provide an objective means for interpreting changes in temporal-spatial, kinematic variability, and dynamic stability measures during perturbed walking which may assist in identifying instability.  相似文献   

17.
The purpose of this study was to determine any potential falls-resistance benefits that might arise from treadmill-slip-perturbation training. One hundred sixty-six healthy community-dwelling older adults were randomly assigned to either the treadmill-slip-training group (Tt) or the treadmill-control group (Tc). Tt received 40 slip-like perturbations during treadmill walking. Tc received unperturbed treadmill walking for 30 min. Following their treadmill session, both groups were exposed to a novel slip during over-ground walking. Their responses to this novel slip were also compared to previously collected data from participants who received either over-ground-slip training (Ot) with 24 slips or over-ground walking (Oc) with no training before experiencing their novel over-ground slip. Fall rates and both proactive (pre-slip) and reactive (post-slip) stability were assessed and compared for the novel over-ground slip in groups Tt, Tc, and Oc, as well as for the 24th slip in Ot. Results showed Tt had fewer falls than Tc (9.6% versus 43.8%, p < 0.001) but more falls than Ot (9.6% versus 0%, p < 0.001). Tt also had greater proactive and reactive stability than Tc (Tt > Tc, p < 0.01), however, Tt’s stabilities were lower than those of Ot (p < 0.01). There was no difference in fall-rate or reactive stability between Tc and Oc, though treadmill walking did improve the proactive stability control of the latter. While the treadmill-slip-training protocol could immediately reduce the numbers of falls from a novel laboratory-reproduced slip, such improvements were far less than that from the motor adaptation to the over-ground-slip-training protocol.  相似文献   

18.
《Journal of biomechanics》2014,47(14):3502-3508
The spatial distribution pattern of neuromuscular activation within the human rectus femoris (RF) muscle was investigated during gait by multi-channel surface electromyography (surface EMG). Eleven healthy men walked on a treadmill with three gait speeds (4, 5, and 6 km/h) and gradients (0°, 12.5°, and 25°). The spatial distribution of surface EMG was tested by central locus activation (CLA), which is calculated from 2-D multi-channel surface EMG with 46 surface electrodes. For all conditions, CLA was around the middle regions during the swing-to-stance transition and moved in a proximal direction during the stance phase and stance-to-swing transition (p<0.05). CLA during the stance-to-swing transition and early swing phase significantly moved to proximal site with increasing gait speed (p<0.05). During the early stance and swing phases, with increasing grade, CLA significantly moved distally (p<0.05). These results suggest that the RF muscle is regionally activated during a gait cycle and is non-uniformly regulated longitudinally.  相似文献   

19.
《IRBM》2022,43(5):447-455
ObjectivesThe deviation in gait cycle due to trunk acceleration and muscle activity on even and uneven inclined planes should be analyzed for the design of lower limb exoskeletons. This study compares the gait variability of gastrocnemius and medial hamstring muscle activity variation of twenty young male adults on inclined even and uneven planes.Material and methodsThe individuals walked on a long, 10° inclined even and uneven plane in both up-the-plane and down-the-plane directions at their preferred speed (average speed is 1.2 m/s). Gait variability during walking was calculated using an average standard deviation of trunk acceleration and the significance of change was calculated using two-way-ANOVA. For studying the difference between integrated electromyography (IEMG) values of walking on even and uneven planes, two parameters Normalized IEMG Percentage (NIP) and IEMG Variation Percentage (IVP) were chosen for the analysis.ResultsThe results strongly agree with the hypothesis that gait variability hikes in the vertical direction of subject with a p-value of 0.04. The IEMG range of medial-hamstring muscle while walking on even and uneven plane is not highly significant for swing (0.44) as well as stance phase (0.47). While walking on an inclined uneven plane, the response of gastrocnemius muscle indicated the variation of NIP between 14.31% to 64.63%. It was observed that NIP and IEMG values of medial-hamstring muscles during backward walking have a resemblance.ConclusionTrunk variability had a significant change in the vertical direction (V) and was insignificant in medial-lateral (ML) and anterior-posterior (AP) orientations for both even and uneven inclined planes during forward and reverse walking. The muscle activity of gastrocnemius and medial-hamstring muscles does not have sound variations while walking on the inclined uneven plane.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号