首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dental implantology has high success rates, and a suitable estimation of how stresses are transferred to the surrounding bone sheds insight into the correct design of implant features. In this study, we estimate stress transfer properties of four commercial implants (GMI, Lifecore, Intri and Avinent) that differ significantly in macroscopic geometry. Detailed three-dimensional finite element models were adopted to analyse the behaviour of the bone-implant system depending on the geometry of the implant (two different diameters) and the bone-implant interface condition. Occlusal static forces were applied and their effects on the bone, implant and bone-implant interface were evaluated. Large diameters avoided overload-induced bone resorption. Higher stresses were obtained with a debonded bone-implant interface. Relative micromotions at the bone-implant interface were within the limits required to achieve a good osseointegration. We anticipate that the methodology proposed may be a useful tool for a quantitative and qualitative comparison between different commercial dental implants.  相似文献   

2.
Implant dimensions greatly influence load transfer characteristics and the lifetime of a dental system. Excessive stresses at peri-implant area may result in bone failure. Finding the critical point at the implant–bone interface and evaluating the influence of implant diameter-to-length ratio on adjacent bone stresses makes it possible to select implant dimensions. For this, different cylindrical implants were numerically analysed using geometrical models generated from computed tomography images of mandible with osseointegrated implants. All materials were assumed to be linearly elastic and isotropic. Masticatory load was applied in its natural direction, oblique to occlusal plane. Maximum von Mises stresses were located around the implant neck at the critical point of its intersection with the plane of loading and were functions of implant diameter-to-length ratio. It was demonstrated that there exists a certain spectrum of diameter-to-length ratios, which will keep maximum bone stresses at a preset level chosen in accordance with patient's bone strength.  相似文献   

3.
Three-dimensional finite element analysis of glass-ceramic dental crowns   总被引:7,自引:0,他引:7  
Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due to the larger magnitude of biting forces on posterior teeth, intraoral fracture of all-ceramic crowns tends to occur more frequently in posterior crowns (Moffa, 1988). The objective of this study was to determine the relative influence of load orientation and the occlusal thickness of posterior ceramic crowns on the stress distribution which develops under these loading and design conditions. Three-dimensional finite element models for a molar crown were developed to determine the stress distribution under simulated applied loads. Glass-ceramic crowns with occlusal thicknesses of 0.5, 1.5, and 3.0 mm were considered. The largest principal tensile stresses induced in ceramic due to a distributed load of 600 N applied in a cuspal region were approximately 12 and 182 MPa for vertical and horizontal loading orientations, respectively. Stresses which developed in the facial and lingual marginal regions were primarily compressive under vertical loads. However, tensile stresses developed when the load was applied horizontally. Differences in stress distribution within crowns with the three occlusal thicknesses occurred only near the site of loading. Because of the relatively large failure rates of ceramic crowns in the posterior regions, these restorations should be strengthened by improvement in design, composition, and thermal processing conditions. Before any significant progress is made in these areas, these restorations should be used for the anterior teeth. The results of this study suggest that orientation of the applied load has a more important effect on development of large tensile stresses than the occlusal thickness of ceramic.  相似文献   

4.
5.
Plantar heel pain is a common condition that is often exacerbated by the repetitive stresses of walking. Treatment usually includes an in-shoe intervention designed to reduce plantar pressure under the heel by using insoles and a variety of off-the-shelf products. The design process for these products is often intuitive in nature and does not always rely on scientifically derived guidelines. Finite element analysis provides an efficient computational framework to investigate the performance of a large number of designs for optimal plantar pressure reduction. In this study, we used two-dimensional plane strain finite element modeling to investigate 27 insole designs. Combinations of three insole conformity levels (flat, half conforming, full conforming), three insole thickness values (6.3, 9.5 and 12.7 mm) and three insole materials (Poron Cushioning, Microcel Puff Lite and Microcel Puff) were simulated during the early support phase of gait. Plantar pressures predicted by the model were validated by experimental trials conducted in the same subject whose heel was modeled by loading the bare foot on a rigid surface and on foam mats. Conformity of the insole was the most important design variable, whereas peak pressures were relatively insensitive to insole material selection. The model predicted a 24% relief in pressure compared to barefoot conditions when using flat insoles; the reduction increased up to 44% for full conforming insoles.  相似文献   

6.
Finite element analysis plays an important role in dental implant design. The objective of this study was to show the effect of the overall geometry of dental implants on their biomechanics after implantation. In this study, 12 dental implants, with the same length, diameter and screw design, were simulated from different implant systems. Numerical model of right mandibular incisor bone segment was generated from CT data. The von-Mises stress distributions and the total deformation distributions under vertical/lateral load were compared for each implant by scores ranking method. The implants with cylindrical shapes had highest scores. Results indicated that cylindrical shape represented better geometry over taper implant. This study is helpful in choosing the optimal dental implant for clinical application and also contributes to individual implant design. Our study could also provide reference for choice and modification of dental implant in any other insertion sites and bone qualities.  相似文献   

7.
Implant separation from bone tissue, resulting in the necessity for revision surgery, is a serious drawback of cementless total joint replacement. Unnatural stress distribution around the implant is considered the main reason for the failure. Optimization of the implant properties, especially its geometric parameters, is believed to be the right way to improve reliability of joint prosthetics. An efficient numerical model of thefemur-implant system is presented in the paper, including the finite element formulation featuring computation of sensitivity gradients, parametric mesh generator, and a gradient-based optimization scheme. Numerical examples show results of shape optimization of an implant for two sets of design parameters and for the initial stability criterion taken as the optimization goal. The optimum shape appears to be relatively long and proximally porous-coated on about half of its length. The method can be flexibly adjusted to various implant types, stress- and displacement-based optimum criteria, and geometric design parameters.  相似文献   

8.
Cardiovascular stent design and vessel stresses: a finite element analysis   总被引:19,自引:0,他引:19  
Intravascular stents of various designs are currently in use to restore patency in atherosclerotic coronary arteries and it has been found that different stents have different in-stent restenosis rates. It has been hypothesized that the level of vascular injury caused to a vessel by a stent determines the level of restenosis. Computational studies may be used to investigate the mechanical behaviour of stents and to determine the biomechanical interaction between the stent and the artery in a stenting procedure. In this paper, we test the hypothesis that two different stent designs will provoke different levels of stress within an atherosclerotic artery and hence cause different levels of vascular injury. The stents analysed using the finite-element method were the S7 (Medtronic AVE) and the NIR (Boston Scientific) stent designs. An analysis of the arterial wall stresses in the stented arteries indicates that the modular S7 stent design causes lower stress to an atherosclerotic vessel with a localized stenotic lesion compared to the slotted tube NIR design. These results correlate with observed clinical restenosis rates, which have found higher restenosis rates in the NIR compared with the S7 stent design. Therefore, the testing methodology outlined here is proposed as a pre-clinical testing tool, which could be used to compare and contrast existing stent designs and to develop novel stent designs.  相似文献   

9.
This paper presents a rig that was specifically designed to simulate the shaking of mechanical models of biological systems, especially those related to shaken baby syndrome (SBS). The scope of this paper includes the testing of an anthropomorphic model that simulates an infant head and provides validation data for complex finite element (FE) modelling using three numerical methods (Lagrangian, Arbitrary-Lagrangian–Eulerian (ALE) and Eulerian method) for fluid structure coupling.The experiments for this study aim to provide an understanding of the influence of two factors on intracranial brain movement of the infant head during violent shaking: (1) the specific paediatric head structure: the anterior fontanelle and (2) the brain–skull interface.The results show that the Eulerian analysis method has significant advantages for the FSI modelling of brain–CSF–skull interactions over the more commonly used methods, e.g. the Lagrangian method. To the knowledge of the authors, this methodology has not been discussed in previous publication.The results indicate that the biomechanical investigation of SBS can provide more accurate results only if the skull with paediatric features and the brain–skull interface are correctly represented, which were overlooked in previous SBS studies.  相似文献   

10.
Biomechanics and Modeling in Mechanobiology - In orthopaedics, conventional implant plates such as locking compression plate (LCP) made from non-biodegradable materials play a vital role in the...  相似文献   

11.
This study investigates the bone/implant mechanical responses in an implant overdenture retained by ball attachments on two conventional regular dental implants (RDI) and four mini dental implants (MDI) using finite element (FE) analysis. Two FE models of overdentures retained by RDIs and MDIs for a mandibular edentulous patient with validation within 6% variation errors were constructed by integrating CT images and CAD system. Bone grafting resulted in 2 mm thickness at the buccal side constructed for the RDIs-supported model to mimic the bone augmentation condition for the atrophic alveolar ridge. Nonlinear hyperelastic material and frictional contact element were used to simulate characteristic of the ball attachment-retained overdentures. The results showed that a denture supported by MDIs presented higher surrounding bone strains than those supported by RDIs under different load conditions. Maximum bone micro strains were up to 6437/2987 and 13323/5856 for MDIs/RDIs under single centric and lateral contacts, respectively. Corresponding values were 4429/2579 and 9557/5774 under multi- centric and lateral contacts, respectively. Bone micro strains increased 2.06 and 1.96-folds under single contact, 2.16 and 2.24-folds under multiple contacts for MDIs and RDIs when lateral to axial loads were compared. The maximum RDIs and MDIs implant stresses in all simulated cases were found by far lower than their yield strength. Overdentures retained using ball attachments on MDIs in poor edentulous bone structure increase the surrounding bone strain over the critical value, thereby damaging the bone when compared to the RDIs. Eliminating the occlusal single contact and oblique load of an implant-retained overdenture reduces the risk for failure.  相似文献   

12.
To isolate the primary variables influencing acetabular cup and interface stresses, we performed an evaluation of cup loading and cup support variables, using a Statistical Design of Experiments (SDOE) approach. We developed three-dimensional finite element (FEM) models of the pelvis and adjacent bone. Cup support variables included fixation mechanism (cemented or noncemented), amount of bone support, and presence of metal backing. Cup loading variables included head size and cup thickness, cup/head friction, and conformity between the cup and head. Interaction between and among variables was determined using SDOE techniques. Of the variables tested, conformity, head size, and backing emerged as significant influences on stresses. Since initially nonconforming surfaces would be expected to wear into conforming surfaces, conformity is not expected to be a clinically significant variable. This indicates that head size should be tightly toleranced during manufacturing, and that small changes in head size can have a disproportionate influence on the stress environment. In addition, attention should be paid to the use of nonmetal backed cups, in limiting cup/bone interface stresses. No combination of secondary variables could compensate for, or override the effect of, the primary variables. Based on the results using the SDOE approach, adaptive FEM models simulating the wear process may be able to limit their parameters to head size and cup backing.  相似文献   

13.
A finite element/multi-body model of a newborn infant has been developed by researchers at the University of Windsor. The geometry of this model is derived from a Nita newborn hospital training mannequin. It consists of 17 parts: eight upper and lower limb segments, the torso, head, and a seven-segment neck with seven translational and eight rotational joints. Anthropometry is consistent with hospital growth charts, measurements requested from health professionals and data from the open literature. The biomechanical properties of the model (i.e. joint stiffnesses) are implementations of data identified in the open literature. The model has been validated with respect to studies of the biomechanics of shaken baby syndrome, infant falls and the Q0 anthropomorphic testing device. A significant conclusion of this study is that the kinetics of the Q0 neck is not biofidelic. This model is currently used in an analysis of airway patency for infants in modern automotive child restraints.  相似文献   

14.
Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core – MAu; zirconia core – MZi) and the quality of the veneer/core interface (complete bonded – MZi; incomplete bonded – MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.  相似文献   

15.
Breast conserving therapy (BCT), comprising a complete surgical excision of the tumour (partial mastectomy) with post-operative radiotherapy to the remaining breast tissue, is feasible for most women undergoing treatment for breast cancer. The goal of BCT is to achieve local control of the cancer, as well as to preserve a breast that satisfies a woman's cosmetic concerns. Although most women undergo partial mastectomy with satisfactory cosmetic results, in many patients the remaining breast is left with major cosmetic defects including concave deformities, distortion of the nipple–areolar complex, asymmetry and changes in tissue density characterised by excessive density associated with parenchymal scarring, as well as breast pain. There are currently no tools, other than surgical experience and judgement, which can predict the impact of partial mastectomy on the contour, the deformity of the treated breast and the mechanical stress that it induces. In this study, we use a finite element model to execute virtual surgery and carry out a sensitivity analysis on the resection location, the resection size, the breast tissue mechanical property and the different post-surgery recovery stage. We output the result in two different built-in indicators labelled as the cosmetic and the functional indicators. This study used the breast model for three women with breast cancer who have been elected to undergo BCT and are being treated at the Methodist Hospital in Houston, TX. The goal of this study was to propose a first glimpse of the key parameter leading to satisfactory post-BCT cosmetic results.  相似文献   

16.
Load direction of applied forces, implant geometry and other biomechanical parameters lead to varying reactions in the surrounding bone structure. Three types of endosseous implant measuring 9 mm in length and 3.3 mm in diameter with and without superperiosteal step, and a threaded surface were investigated with the aid of a finite element method using the COSMOS/M 2.5 program. The load on the implant was investigated under vertical, horizontal, and diagonal forces of between 0.01 N and 100 N. Vertical loading of simple implants caused bone deformation of more than 600 mu eps. The application of the superperiosteal step clearly reduced the deformation. The largest deformations under vertical loading were observed in the trabecular bone with all 3 implant geometries. On horizontal loading the deformation shifted from the trabecular to the cortical bone and was particularly marked at the transition between the two. The smallest deformations, less than 300 mu eps, were measured at implants with a superperiosteal step under diagonal loading. The thread did not improve loading capacity. Implants with a superperiosteal step are recommended since they contribute to more rapid healing and strengthening of the bone.  相似文献   

17.
Telescopic overdentures supported by the combination of natural teeth and implants have been thought a valuable treatment for the severely compromised partially edentulous patients. But the combination of teeth and implants involves highly complex biomechanical problems. This study is to evaluate biomechanical behaviors of the natural abutment teeth with the treatment of combined tooth-implant supported telescopic crown prostheses in mandible through 3D FEA. According to this study, the prosthetic option supported by a combination of teeth and implants and retained by double crowns could protect teeth and their periodontal support tissues acting as a rigid splint, and may be a valuable treatment option for partially edentulous patients with severely reduced remaining teeth in mandible.  相似文献   

18.
The relative vulnerability of spinal motion segments to different loading combinations remains unknown. The meta-analysis described here using the results of a validated L2-L3 nonlinear viscoelastic finite element model was designed to investigate the critical loading and its effect on the internal mechanics of the human lumbar spine. A Box-Behnken experimental design was used to design the magnitude of seven independent variables associated with loads, rotations and velocity of motion. Subsequently, an optimization method was used to find the primary and secondary variables that influence spine mechanical output related to facet forces, disc pressure, ligament forces, annulus matrix compressive/shear stresses and anulus fibers strain. The mechanical responses with respect to the two most-relevant variables were then regressed linearly using the response surface quadratic model. Axial force and sagittal rotation were identified as the most-relevant variables for mechanical responses. The procedure developed can be used to find the critical loading for finite element models with multi input variables. The derived meta-models can be used to predict the risk associated with various loading parameters and in setting safer load limits.  相似文献   

19.
20.
This paper is concerned with the mechanical strength of fixed osseointegrated dental implants subjected to cyclic external loads, applied mainly in a direction orthogonal to their axis. Such a loading condition, seen as a basic design action for the implant, has been given little attention so far. Experimental results and numerical simulations, performed on two- and three-dimensional Finite Element models, are discussed. The shakedown theory is used to show that a common implant design (threaded fixture-abutment-connection screw) is susceptible of low-cycle fatigue failure under loading conditions well within the working range, even if the same design is able to withstand loading of the same type, but applied monotonically, much in excess of the working values. The shakedown analyses give an indication of several possible failure modalities: the low-cycle fatigue either of the implant or of the connection screw, or the loosening of the connection screw itself. Experimental and numerical results are in good qualitative agreement, and both suggest that the issue of transversal cyclic loading on fixed dental implants should be carefully reconsidered in the design phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号