首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Accuracy in microarray technology requires new approaches to microarray reader development. A microarray reader system (optical scanning array or OSA reader) based on automated microscopy with large field of view, high speed 3 axis scanning at multiple narrow-band spectra of excitation light has been developed. It allows fast capture of high-resolution, multi-fluorescence images and is characterized by a linear dynamic range and sensitivity comparable to commonly used photo-multiplier tube (PMT)-based laser scanner. Controlled by high performance software, the instrument can be used for scanning and quantitative analysis of any type of dry microarray. Studies implying temperature-controlled hybridization chamber containing a microarray can also be performed. This enables the registration of kinetics and melting curves. This feature is required in a wide range of on-chip chemical and enzymatic reactions including on-chip PCR amplification. We used the OSA reader for the characterization of hybridization and melting behaviour of oligonucleotide:oligonucleotide duplexes on three-dimensional Code Link slides.  相似文献   

2.
Optical inteference (OI) coated slides with unique optical properties were utilized in microarray analyses, demonstrating their enhanced detection sensitivity over traditional microarray substrates. The OI coating is comprised of a proprietary multilayered, dielectric, thin-film interference coating located beneath the functional coating (aminosilane or epoxysilane). It is designed to enhance the fluorescence in the Cy3 and Cy5 channel by increasing the light absorption of the dyes by about 6-fold and by redirecting emitted fluorescence into the detector during scanning, resulting in a theoretical limit of about 12-fold signal amplification. Two-color DNA microarray experiments conducted on the OI slides showed over 8-fold signal amplification, conservation of gene expression ratios, and increased signal-to-noise ratio when compared to control slides, indicating enhanced detection sensitivity. Protein microarray assays also exhibited over 8-fold signal amplification at three different target concentrations, demonstrating the versatility of the OI slides for different microarray applications. Further, the DNA and protein assays performed on the OI slides exhibited excellent detection sensitivity even at the low target amounts essential for diagnostic applications. The OI slides are compatible with commonly used protocols, printers, scanners and other microarray equipment. Therefore, the OI slides offer an attractive alternative to traditional microarray substrates, where enhanced detection sensitivity is desired.  相似文献   

3.
This article presents a new technique to fabricate patterns of functional molecules surrounded by a coating of the inert poly(ethylene glycol) (PEG) on glass slides for applications in protein microarray technology. The chief advantages of this technique are that it is based entirely on standard lithography processes, makes use of glass slides employing surface chemistries that are standard in the microarray community, and has the potential to massively scale up the density of microarray spots. It is shown that proteins and antibodies can be made to self-assemble on the functional patterns in a microarray format, with the PEG coating acting as an effective passivating agent to prevent non-specific protein adsorption. Various standard surface chemistries such as aldehyde, epoxy and amine are explored for the functional layer, and it is conclusively demonstrated that only an amine-terminated surface satisfies all the process constraints imposed by the lithography process sequence. The effectiveness of this microarray technology is demonstrated by patterning fluorescent streptavidin and a fluorescent secondary antibody using the well-known and highly specific interaction between biotin and streptavidin.  相似文献   

4.

Background  

The antibody microarray technique is a newly emerging proteomics tool for differential protein expression analyses that uses fluorescent dyes Cy 3 and Cy 5. Environmental factors, such as light exposure, can affect the signal intensity of fluorescent dyes on microarray slides thus, it is logical to scan microarray slides immediately after the final wash and drying processes. However, no research data are available concerning time-dependent changes of fluorescent signals on antibody microarray slides to this date. In the present study, microarray slides were preserved at -20°C after regular microarray experiments and were rescanned at day 10, 20 and 30 to evaluate change in signal intensity.  相似文献   

5.
Park T  Yi SG  Lee S  Lee JK 《BioTechniques》2005,38(3):463-471
Different sources of systematic and random error variations are often observed in cDNA microarray experiments. A simple scatter plot is commonly used to examine outlying slides that have unusual expression patterns or larger variability than other slides. These outlying slides tend to have large impacts on the subsequent analyses, such as identification of differentially expressed genes and clustering analysis. However, it is difficult to select outlying slides rigorously and consistently based on subjective human pattern recognition on their scatter plots. A graphical method and a rigorous diagnostic measure are proposed to detect outlying slides. The proposed graphical method is easy to implement and shown to be quite effective in detecting outlying slides in real microarray data sets. This diagnostic measure is also informative to compare variability among slides. Two cDNA microarray data sets are carefully examined to illustrate the proposed approach. A 3840-gene microarray experiment for neuronal differentiation of cortical stem cells and a 2076-gene microarray experiment for anticancer compound time-course expression of the NCI-60 cancer cell lines.  相似文献   

6.
A novel class of chemical microchips consisting of glass microscope slides was prepared for the covalent attachment of small molecule ligands and peptides through site-specific oxime bond or thiazolidine ring ligation reaction. Commercially available microscope slides were thoroughly cleaned and derivatized with (3-aminopropyl)triethoxysilane (APTES). The amino slides were then converted to glyoxylyl derivatives via two different routes: (1) coupling of Fmoc-Ser followed by deprotection and oxidation, or (2) coupling with protected glyoxylic acid and final deprotection with HCl. Biotin or peptide ligands derivatized at the carboxyl terminus with a 4,7,10-trioxa-1,13-tridecanediamine succinimic acid linker and an amino-oxy group or a 1,2-amino-thiol group (e.g., cysteine with a free N(alpha)-amino group) were printed onto these slides using a DNA microarray spotter. After chemical ligation, the microarray of immobilized ligands was analyzed with three different biological assays: (1) protein-binding assay with fluorescence detection, (2) functional phosphorylation assay using [gamma(33)P]-ATP and specific protein kinase to label peptide substrate spots, and (3) adhesion assay with intact cells. In the cell adhesion assay, not only can we determine the binding specificity of the peptide against different cell lines, we can also determine functional cell signaling of attached cells using immunofluorescence techniques in situ on the microchip. This chemical microchip system enables us to rapidly analyze the functional properties of numerous ligands that we have identified from the "one-bead one-compound" combinatorial library method.  相似文献   

7.
8.
Dufva M  Petronis S  Jensen LB  Krag C  Christensen CB 《BioTechniques》2004,37(2):286-92, 294, 296
An agarose film has been proposed as an efficient substrate for producing microarrays. The original film preparation procedure was simplified significantly by grafting the agarose layer directly onto unmodified microscope glass slides instead of aminated glass slides, and the blocking procedure was replaced with a wash in 0.1x standard saline citrate (SSC) and 0.5% sodium dodecyl sulfate (SDS) without decreasing the performance of the produced microarrays. Characterization of the grafted agarose film using atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that the agarose film had a 10-fold increase in surface roughness compared to glass and that the interior of the agarose film was porous, with pore sizes between 100-500 nm. A comparison of hybridization on aldehyde-activated agarose-coated microarray slides and commercial amino-reactive microarray slides showed that aldehyde-activated agarose-coated slides had the highest signal-to-noise ratio of 850, suggesting that the aldehyde-activated agarose microarray slides are suitable in applications where analytes have a wide concentration range. By immobilizing the DNA probes using ultraviolet (UV) light, the signal-to-noise ratio was further increased to 3000 on the agarose microarray slides. The specificity of the UV cross-linked DNA probes was demonstrated using 21 and 25 bp long capture probes, enabling discrimination of target molecules differing in only one base.  相似文献   

9.
This paper describes an approach for preparing unimolecular double-stranded DNA (uni-dsDNA) microarray chip. In this method, the various target oligonucleotides containing a reverse complementary sequence at 5' end were firstly annealed to a same universal oligonucleotide with amino group at 5' end and immobilized on aldehyde-derivatized glass slide. An on-chip DNA polymerization reaction was then performed to elongate the universal oligonucleotides. After a denaturation and a followed intra-strand annealing, a hairpin structure was formed at the free 3' end of the immobilized oligonucleotides. Finally, another on-chip DNA polymerization was done to synthesize the uni-dsDNA microarray. Combining with a PCR amplification of chemically synthesized target oligonucleotides, this method was much cost-effective for production of the uni-dsDNA microarray. The uni-dsDNA microarray was verified applicable for detecting the presence and monitoring the DNA-binding activity of the sequence-specific DNA-binding proteins.  相似文献   

10.
DNA microarray technology holds significant promise for human DNA diagnostics. A number of technical approaches directed at the parallel identification of mutations or single nucleotide polymorphisms make use of polymerase-based specificity, like minisequencing or allele-specific primer elongation. These techniques, however, require separate laborious sample amplification, preparation, and purification steps, making large-scale analyses time and cost consuming. Here, we address this challenge by applying an experimental setup using simultaneous solid and liquid phase PCR on polyethyleneimine-coated glass slides, a novel microarray support allowing on-chip amplification reactions with exquisite specificity. A gene-specific oligonucleotide tiling array contains covalently attached allele-specific primers which interrogate single nucleotide positions within a genomic region of interest. During a thermal cycling reaction amplification products remain covalently bound to the solid support and can be visualized and analyzed by the incorporation of fluorescent dyes. Using the described procedure we unequivocally defined the presence of point mutations in the human tumor suppressor gene p53 directly from a natural DNA source. This semi-multiplex solid phase amplification format allowed the rapid and correct identification of 20 nucleotide positions from minute amounts of human genomic DNA. Our results suggest that this approach might constitute a vital component of future integrated DNA chip devices used in gene analysis.  相似文献   

11.
Microarrays have been used extensively in gene expression profiling and genotyping studies. To reduce the high cost and enhance the consistency of microarray experiments, it is often desirable to strip and reuse microarray slides. Our genome-wide analysis of microRNA expression involves the hybridization of fluorescently labeled nucleic acids to custom-made, spotted DNA microarrays based on GAPSII-coated slides. We describe here a simple and effective method to regenerate such custom microarrays that uses a very low-salt buffer to remove labeled nucleic acids from microarrays. Slides can be stripped and reused multiple times without significantly compromising data quality. Moreover, our analyses of the performance of regenerated slides identifies parameters that influence the attachment of oligonucleotide probes to GAPSII slides, shedding light on the interactions between DNA and the microarray surface and suggesting ways in which to improve the design of oligonucleotide probes.  相似文献   

12.
Affibody molecules, 58-amino acid three-helix bundle proteins directed to different targets by combinatorial engineering of staphylococcal protein A, were used as capture ligands on protein microarrays. An evaluation of slide types and immobilization strategies was performed to find suitable conditions for microarray production. Two affibody molecules, Z(Taq) and Z(IgA), binding Taq DNA polymerase and human IgA, respectively, were synthesized by solid phase peptide synthesis using an orthogonal protection scheme, allowing incorporation of selective immobilization handles. The resulting affibody variants were used for random surface immobilization (through amino groups) or oriented surface immobilization (through cysteine or biotin coupled to the side chain of Lys58). Evaluation of the immobilization techniques was carried out using both a real-time surface plasmon resonance biosensor system and a microarray system using fluorescent detection of Cy3-labeled target protein. The results from the biosensor analyses showed that directed immobilization strategies significantly improved the specific binding activity of affibody molecules. However, in the microarray system, random immobilization onto carboxymethyl dextran slides and oriented immobilization onto thiol dextran slides resulted in equally good signal intensities, whereas biotin-mediated immobilization onto streptavidin-coated slides produced slides with lower signal intensities and higher background staining. For the best slides, the limit of detection was 3 pM for IgA and 30 pM for Taq DNA polymerase.  相似文献   

13.
14.
15.
To establish a rapid, sensitive and specific diagnostic assay for Hantavirus with microarray techniques, specific primers and probes were designed according to the conservative and specific DNA sequence of 76-118 strain and R22 strain. The probes were spotted on glass slides to form microarrays.The Cy3-1abled single stranded DNA fragments prepared by dissymmetical PCR were hybridized with the probes on the glass slides. The microarrays were scanned and analyzed with a scanner. The results showed that the DNA microarray could detect the different typed DNA of HTN and SEO with adequate specificity and sensitivity. The developed DNA microarray and techniques might be a very useful method for diagnosis and prevention, and could be widely applied in specific pathogens detection ofinfectious diseases such as hemorrhagic fever with renal syndrome.  相似文献   

16.
FAST slides: a novel surface for microarrays   总被引:3,自引:0,他引:3  
We have evaluated FAST slides, a glass slide with a microporous polymeric surface that is a suitable substrate for microarray technology. The surface is a nitrocellulose-based polymer that binds DNA and proteins in a noncovalent but irreversible manner. FAST slides are compatible with robotic systems currently used to create microarrays and can easily accommodate volumes of 0.03-2 nL/spot. Our data indicate that FAST slides have a much higher binding capacity for DNA and better spot-to-spot consistency than traditional poly-lysine-coated slides. In addition, FAST slides are well suited for fluorescent detection because of their relatively low light scatter and efficient retention of arrayed DNA. These properties translate into fluorescent sensitivity comparable to modified glass surfaces. FAST slides are also ideal for arraying proteins, making them the only substrate of their kind currently available for microarray applications.  相似文献   

17.
High-throughput methods for generating aptamer microarrays are described. As a proof-of-principle, the microarrays were used to screen the affinity and specificity of a pool of robotically selected antilysozyme RNA aptamers. Aptamers were transcribed in vitro in reactions supplemented with biotinyl-guanosine 5'-monophosphate, which led to the specific addition of a 5' biotin moiety, and then spotted on streptavidin-coated microarray slides. The aptamers captured target protein in a dose-dependent manner, with linear signal response ranges that covered seven orders of magnitude and a lower limit of detection of 1 pg/mL (70 fM). Aptamers on the microarray retained their specificity for target protein in the presence of a 10,000-fold (w/w) excess of T-4 cell lysate protein. The RNA aptamer microarrays performed comparably to current antibody microarrays and within the clinically relevant ranges of many disease biomarkers. These methods should also prove useful for generating other functional RNA microarrays, including arrays for genomic noncoding RNAs that bind proteins. Integrating RNA aptamer microarray production with the maturing technology for automated in vitro selection of antiprotein aptamers should result in the high-throughput production of proteome chips.  相似文献   

18.
Serodiagnosis of infectious diseases with antigen microarrays   总被引:9,自引:0,他引:9  
AIMS: To generate protein microarrays by printing microbial antigens on slides to enable the simultaneous determination in human sera of antibodies directed against Toxoplasma gondii, rubella virus, cytomegalovirus and herpes simplex virus (HSV) types 1 and 2. METHODS AND RESULTS: Antigens were printed on activated glass slides using high-speed robotics. The slides were incubated with serum samples and subsequently with fluorescently labelled secondary antibodies. Human IgG and IgM bound to the printed antigens were detected using confocal scanning microscopy and quantified with internal calibration curves. The microarray assay could detect as little as 0.5 pg of both IgG and IgM bound onto the glass surface. Precision profiles ranged from 1.7 to 18.5% for all the antigens. Microarrays and commercial ELISAs were utilized to detect serum antibodies against the ToRCH antigens in a panel of characterized human sera. Overall >80% concordance was obtained between microarray and ELISA kits in the classification of sera. CONCLUSIONS: These results indicate that the microarray is a suitable assay format for the serodiagnosis of infectious diseases. SIGNIFICANCE AND IMPACT OF STUDY: Antigen microarrays can be optimized for clinical use, their performance is equivalent to ELISA but they offer significant advantages in throughput, convenience and cost.  相似文献   

19.
High-density arrays of DNA bound to solid substrates offer a powerful approach to identifying changes in gene expression in response to toxicants. While DNA arrays have been used to explore qualitative changes in gene regulation, less attention has focused on the quantitative aspects of this technology. Arrays containing expressed sequence tags for xenobiotic metabolizing enzymes, proteins associated with glutathione regulation, DNA repair enzymes, heat shock proteins, and housekeeping genes were used to examine gene expression in response to beta-naphthoflavone (beta-NF). Upregulation of cytochrome P4501a1 (Cyp1a1) and 1a2 in mouse liver was maximal 8 h after beta-NF administration. Significant upregulation of Cyp1a2 was noted at beta-NF doses as low as 0.62 and 1.2 mg/kg when gene expression was measured by microarray or Northern blotting, respectively. Maximal Cyp1a2 induction is 5-fold by Northern analysis and 10-fold by microarray. Induction of Cyp1a1 was 15- and 20-fold by Northern and microarray analysis, respectively. The coefficient of variation for spot to spot and slide to slide comparisons was <15%; this variability was smaller than interanimal variability (18-60%). Comparison of mRNA expression in control animals indicated that there are differences in labeling/detection associated with Cy3/Cy5 dyes; accordingly, experiments must include methods for establishing baseline signals for all genes. We conclude that the dynamic range and sensitivity of DNA microarrays on glass slides is comparable to Northern blotting analysis and that variability of the data introduced during spotting and hybridization is less than the interanimal variability.  相似文献   

20.
A lipase substrate microarray was obtained by printing aliphatic C2-C12 monoesters of (5R)- and (5S)-3-(5,6-dihydroxyhexyloxy)benzaldehyde by reductive alkylation on amine-functionalized glass slides coated with bovine serum albumin and a short PEG linker. The microarray features 12 substrates and their 66 possible binary mixtures spotted in a 9 x 36 spot array. Lipase reactions are detected by chemoselective NaIO(4)-oxidation of the 1,2-diol hydrolysis product to form an aldehyde, which is then tagged with the red-fluorescent dye rhodamine B sulfohydrazide . Specific fingerprints are produced by active enzymes. These experiments provide the first example of lipase fingerprinting using microarrays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号