首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An amperometric enzyme-linked immunosensor was developed to detect and quantify levels of Staphylococcus aureus electrically in pure cultures and in foods. The assay was a modification of a 'sandwich' ELISA for the protein A of Staph. aureus, employing catalase-labelled anti-protein A antibody. On addition of hydrogen peroxide to the assay system the catalase released O2 which was monitored using an amperometric oxygen electrode. The rate of current increase was proportional to the antigen concentration (protein A or Staph. aureus). Protein A was detected reliably at 0.1 ng/ml representing a 20-fold increase in sensitivity over the conventional ELISA that used horseradish peroxidase. Pure cultures of Staph. aureus were detected at 10(-3)-10(-4) cfu/ml with the amperometric electrode (cf greater than 10(5)/ml for conventional ELISA). The same level of sensitivity was achieved for inoculated food samples. Low levels of contamination (1 cfu/g) of Staph. aureus were detected after incubation at 37 degrees C for 18 h, and the immunosensor could from the basis of a test for screening and identification of protein A-bearing Staph. aureus in 24 h, although natural variations in protein A content between different strains could make the system unreliable in accurate quantification of cell numbers.  相似文献   

2.
Summary A semi-homogeneous amperometric immunosensor specific to the protein A of Staphylococcus aureus was developed using direct electrochemical detection of phenol produced by alkaline phosphatase from phenyl phosphate. The immunosensor could reliably detect strains of protein A-bearing S. aureus in pure cultures at ca. 304 cfu/ml, and at ca. 105 cfu/g or ml in various food samples. Due to its semi-homogeneous nature, the system was very simple, easy to operate, and labour-saving. The good correlation between the amperomatric current generated by the immunosensor and plate counts illustrated the potential usefulness of this simple system. It proved to be a reliable 24-h detection method for food samples containing very low numbers of protein A-bearing S. aureus after pre-enrichment, as it was able to detect cells that could not directly be enumerated by plate counts.Offprint requests to: R. G. Kroll  相似文献   

3.
摘要:【目的】结合纳米技术建立检测大肠杆菌(Escherichia coli)O157︰H7高灵敏检测技术。【方法】采用化学共沉淀法制备出核心粒径约为10 nm的免疫纳米磁颗粒,柠檬酸钠还原法制备粒径约为20 nm的免疫胶体金。压电免疫传感器通过金黄色葡萄球菌蛋白A(Protein A from Staphylococcus aureus SPA)法将抗体固定于石英晶振上,两种免疫纳米颗粒借助不同的抗体连接于传感器上对检测频率信号进行放大。【结果】SPA在石英晶振上的最佳固定浓度和时间为1.2 mg/mL和40 min,抗体的最佳固定浓度和时间为1.0 mg/mL和60 min。压电免疫传感器通过两种免疫纳米颗粒的放大作用,使其对大肠杆菌O157︰H7的检测限从104 cfu/mL提高到101 cfu/mL。【结论】免疫纳米颗粒强化对压电免疫传感器的检测频率信号具有很好的放大效应,可以明显提高其检测灵敏度。  相似文献   

4.
In this paper, we describe a novel method for detecting Escherichia coli (E. coli) O157:H7 by using a quartz crystal microbalance (QCM) immunosensor based on beacon immunomagnetic nanoparticles (BIMPs), streptavidin-gold, and growth solution. E. coli O157-BIMPs were magnetic nanoparticles loaded with polyclonal anti-E. coli O157:H7 antibody (target antibody, T-Ab) and biotin-IgG (beacon antibody, B-Ab) at an optimized ratio of 1:60 (T-Ab:B-Ab). E. coli O157:H7 was captured and separated by E. coli O157-BIMPs in a sample, and the streptavidin-gold was subsequently conjugated to E. coli O157-BIMPs by using a biotin-avidin system. Finally, the gold particles on E. coli O157-BIMPs were enlarged in growth solution, and the compounds containing E. coli O157:H7, E. coli O157-BIMPs, and enlarged gold particles were collected using a magnetic plate. The QCM immunosensor was fabricated with protein A from Staphylococcus aureus and monoclonal anti-E. coli O157:H7 antibody. The compounds decreased the immunosensor's resonant frequency. E. coli O157-BIMPs and enlarged gold particles were used as "mass enhancers" to amplify the frequency change. The frequency shift was correlated to the bacterial concentration. The detection limit was 23 CFU/ml in phosphate-buffered saline and 53 CFU/ml in milk. This method could successfully detect E. coli O157:H7 with high specificity and stability. The entire procedure for the detection of E. coli O157:H7 took only 4 h.  相似文献   

5.
A surface plasmon resonance (SPR) based immunosensor using self-assembled protein G was developed for the detection of Salmonella paratyphi. In order to endow a solid substrate binding affinity to protein G, the free amine (-NH2) of protein G was substituted into thiol (-SH) using 2-iminothiolane. Thus, self-assembled protein G was fabricated on gold (Au) substrate. The formation of protein G layer on Au surface, and the binding of antibody and antigen in series were confirmed by SPR spectroscopy. The surface morphology analysis of the protein G layer on Au surface was performed by atomic force microscope (AFM). Consequently, an immunosensor based on SPR for the detection of S. paratyphi using self-assembled protein G was developed with a detection range of 10(2)-10(7) CFU/ml. The current fabrication technique of a SPR immunosensor for the detection of S. paratyphi could be applied to construct other immnosensors or protein chips.  相似文献   

6.
A piezoelectric immunosensor was developed for rapid detection of Escherichia coli O157:H7. It was based on the immobilization of affinity-purified antibodies onto a monolayer of 16-mercaptohexadecanoic acid (MHDA), a long-chain carboxylic acid-terminating alkanethiol, self-assembled on an AT-cut quartz crystal's Au electrode surface with N-hydroxysuccinimide (NHS) ester as a reactive intermediate. The binding of target bacteria onto the immobilized antibodies decreased the sensor's resonant frequency, and the frequency shift was correlated to the bacterial concentration. The stepwise assembly of the immunosensor was characterized by means of both quartz crystal microbalance (QCM) and cyclic voltammetry techniques. Three analytical procedures, namely immersion, dip-and-dry and flow-through methods, were investigated. The immunosensor could detect the target bacteria in a range of 10(3)-10(8)CFU/ml within 30-50 min, and the sensor-to-sensor reproducibility obtained at 10(3) and 10(5) colony-forming units (CFU)/ml was 18 and 11% R.S.D., respectively. The proposed sensor was comparable to Protein A-based piezoelectric immunosensor in terms of the amount of immobilized antibodies and detection sensitivity.  相似文献   

7.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

8.
A sensitive amperometric immunosensor for carcinoembryonic antigen (CEA) was prepared. Firstly, a porous nano-structure gold (NG) film was formed on glassy carbon electrode (GCE) by electrochemical reduction of HAuCl4 solution, then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, and finally the anti-CEA was adsorbed onto the surface of the bilayer gold nanoparticles to construct an anti-CEA/nano-Au/Chit/NG/GCE immunosensor. The characteristics of the modified electrode at different stages of modification were studied by cyclic voltammetry (CV). The gold colloid, chitosan and nano-Au/Chit were characterized by transmission electron microscopy and UV–vis spectroscopy. In addition, the performances of the immunosensor were studied in detail. The resulting immunosensor offers a high-sensitivity (1310 nA/ng/ml) for the detection of CEA and has good correlation for detection of CEA in the range of 0.2 to 120.0 ng/ml with a detection limit of 0.06 ng/ml estimated at a signal-to-noise ratio of 3. The proposed method can detect the CEA through one-step immunoassay and would be valuable for clinical immunoassay.  相似文献   

9.
A fluorescence-based continuous-flow immunosensor for sensitive, precise, accurate and fast determination of paclitaxel was developed. The sensor utilizes anti-paclitaxel antibody immobilized through its Fc region and crosslinked by dimethylpimelimidate to protein A attached covalently onto the silanized inner walls of a glass capillary column followed by saturation of the paclitaxel-binding sites with rhodamine-labeled paclitaxel. The assay is based on the displacement and detection downstream of the rhodamine-labeled paclitaxel, by a flow-through spectrofluorometer, as a result of the competition with paclitaxel introduced as a pulse into the stream of carrier buffer flowing through the system. The peak height of the fluorescence intensity profile of the displaced rhodamine-labeled paclitaxel was directly proportional to the concentration of paclitaxel applied and was a function of the carrier buffer flow rate. The sensitivity of the immunosensor response ranged from 0.31 relative fluorescence units (RFU)/ng/ml at a flow rate 0.1 ml/min to 0.52 RFU/ng/ml at 1 ml/min, while the lower detection limit ranged from 1 ng/ml at 0.1 ml/min to 4 ng/ml at 1 ml/min. The immunosensor response was very reproducible (RSD=4.8%; n=10) and linear up to 100 ng/ml. The assay time ranged from 2 min at 1 ml/min to 8 min at 0.1 ml/min. A technique developed to resaturate the antigen binding sites of the immobilized antibody with rhodamine-labeled paclitaxel was successful in regenerating the capillary column without affecting its performance, thus enhancing the economic viability of the immunosensor. The immunosensor was successfully applied for the determination of paclitaxel in human plasma.  相似文献   

10.
Yi W  Liang W  Li P  Li S  Zhang Z  Yang M  Chen A  Zhang B  Hu C 《Biotechnology letters》2011,33(8):1539-1543
N-Terminal pro-brain natriuretic peptide (NT-proBNP) is an important marker for heart failure that reflects ventricular volume expansion, ventricular overload and the degree of cardiac injury. To establish a sensitive and simple detection method for it in serum, a regeneration-free immunosensor with novel Fab fragment monoclonal antibodies was prepared. The sensor detected NT-proBNP from 0.04 to 2.5 ng/ml with a limit of 0.03 ng/ml. The immunosensor is therefore a simple, cost-effective method to detect NT-proBNP and the proposed immunoassay system would enable other proteins to be detected and open new opportunities for protein diagnostics.  相似文献   

11.
A label-free immunosensor for the detection of α-fetoprotein (AFP) is proposed based on controlled fabrication of monoclonal antibodies of AFP (anti-AFP) and gold nanoparticles (GNPs) inside the pores of mesoporous silica (MPS). The silanol groups on the internal pore walls were grafted by aminopropyltriethoxyl silane, whereas the silanol groups on the external surface of MPS were blocked by trimethylchlorosilane (TMCS). Thus, anti-AFP and GNPs could be confined inside the mesopores of TMCS-MPS by the covalent linking with the amino groups. The prepared anti-AFP/GNPs/TMCS-MPS particles were used to modify glassy carbon electrode (GCE) to construct a label-free immunosensor. After incubating the sample AFP with the anti-AFP/GNPs/TMCS-MPS/GCE, the immunoconjugates were formed on the surface of GCE and the spatial block increased. Thus, the peak current decreased with increasing concentrations of AFP. GNPs inside the mesopores could promote the electron transportation through the pore channel. Under the optimal experimental conditions, the fabricated immunosensor could detect AFP in a linear range from 1.0 to 90 ng ml(-1) with a detection limit of 0.2 ng ml(-1) (3σ). It provided a novel alternative method for the label-free determination of other antigens.  相似文献   

12.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

13.
An immunosensor based on surface plasmon resonance (SPR) using protein G was developed for the detection of Salmonella typhimurium. A protein G layer was fabricated by binding chemically to self-assembly monolayer (SAM) of 11-mercaptoundecanoic acid (MUA) on gold (Au) surface. The formation of protein G layer on Au surface modified with 11-MUA and the binding of antibody and antigen in series were confirmed by SPR spectroscopy. The effect of detergent such as Tween-20 on binding efficiency of antibody and antigen was investigated by SPR. The binding efficiency of antigen to the antibody immobilized on Au surface was improved up to about 85% and 100% by using protein G and Tween-20, respectively. The surface morphology analyses of 11-MUA monolayer on Au substrate, protein G layer on 11-MUA monolayer and antibody layer immobilized on protein G layer were performed by atomic force microscope (AFM). Consequently, an immunosensor based on SPR for the detection of S. typhimurium using protein G was developed with a detection range of 10(2) to 10(9)CFU/ml. The current fabrication technique of a SPR immunosensor for the detection of S. typhimurium could be applied to construct other immnosensors or protein chips.  相似文献   

14.
An amperometric immunosensor for polycyclic aromatic hydrocarbons (PAHs) was developed. The immunosensor was based on disposable screen-printed carbon electrodes. The coating antigen used was phenanthrene-9-carboxaldehyde coupled to bovine serum albumin (BSA) via adipic acid dihydrazide. Antibodies were monoclonal mouse anti-phenanthrene. The enzyme alkaline phosphatase (AP) was used in combination with the substrate p-aminophenyl phosphate (pAPP) for detection at +300 mV (vs. Ag/AgCl). Various assay types were compared. Good results were achieved with an indirect co-exposure competition assay with a LOD of 0.8 ng/ml (800 ppt) and an IC(50) of 7.1 ng/ml (7.1 ppb) for phenanthrene. An indirect competition assay could detect phenanthrene with a LOD of 2 ng/ml (IC(50): 15 ng/ml) and an indirect displacement assay with a LOD of 2 ng/ml (IC(50): 11 ng/ml) at a 5 microl surface coating of 8.8 microg/ml phenanthrene-BSA conjugate. A coating concentration of 2.2 microg/ml allowed detection with a LOD of 0.25 ng/ml (250 ppt) with the indirect competition assay. The influence of the coating concentration on the sensor performance was investigated. Cross-reactivities were tested for 16 important PAHs. Anthracene and chrysene showed strong cross-reactivity, whereas benzo[g,h,i]perylene and dibenzo[a,h]anthracene showed no cross-reactivity.  相似文献   

15.
In this study, five polyaniline compounds were synthesized using different protonic acids and incorporated into a conductometric biosensor used for bovine viral diarrhea virus detection. The biosensor was developed and evaluated by the authors for bacterial pathogen detection in previous studies. The biosensor consisted of two parts: the immunosensor and the electronic data collection system. Liquid sample moved through the immunosensor surface by capillary action. The specificity of the biosensor was based on the unique binding characteristics of the polyclonal and monoclonal antibodies immobilized on the immunosensor. Polyaniline was used in the biosensor architecture as the transducer due to its electronic and bio-molecular properties. Results showed that the biosensor was sensitive at a concentration of 10(3) cell culture infective dose per milliliter (CCID/ml) of BVDV antigens. The promising results on the BVDV detection demonstrated that the conductometric biosensor was interchangeable for different target molecules of detection. Further modification could be implemented to evaluate the biosensor as a rapid diagnostic device to detect other infectious disease outbreaks in livestock population.  相似文献   

16.
An amperometric immunosensor was fabricated for the detection of osteoproteogerin (OPG) by covalently immobilizing a monoclonal OPG antibody (anti-OPG) onto the gold nanoparticles (AuNPs) deposited functionalized conducting polymer (5,2′:5′,2″-terthiophene-3′-carboxylic acid). AuNPs were electrochemically deposited onto the conducting polymer using cyclic voltammetry. The particle size of deposited AuNPs was controlled by varying the scan rate and was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The immobilization of anti-OPG was also confirmed using XPS. The principle of immunosensor was based on a competitive immunoassay between free-OPG and labeled-OPG for the active sites of anti-OPG. HRP was used as a label that electrochemically catalyzes the H2O2 reduction. The catalytic reduction was monitored amperometrically at −0.4 V vs. Ag/AgCl. The immunosensor showed a linear range between 2.5 and 25 pg/ml and the detection limit was determined to be 2 pg/ml. The proposed immunosensor was successfully applied for real human samples to detect OPG.  相似文献   

17.
A multiplexing electrochemical immunosensor was developed for ultrasensitive detection of cancer related protein biomarkers. We employed disposable screen-printed carbon electrode (SPCE) array as the detection platform. A universal multi-labeled nanoprobe was developed by loading HRP and goat-anti-rabbit IgG (secondary antibody, Ab2) onto multiwalled carbon nanotube (MWNT). This universal nanoprobe was available for virtually any sandwich-based antigen detection and showed superiority in several areas. By using the SPCE array and the universal nanoprobe, we could detect as low as 5 pg mL−1 of prostate specific antigen (PSA) and 8 pg mL−1 of Interleukin 8 (IL-8) with the electrochemical immunosensor. We also demonstrated simultaneous detection of two protein biomarkers with this platform. With these attracted features, our immunoassay system shows promising applications for in-field and point-of-care test in clinical diagnostics.  相似文献   

18.
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.  相似文献   

19.
A novel multi-array immunoassay device based on the insert-plug model of piezoelectric (Pz) immunosensor fabricated with the screw clamp apparatus has been developed for quantitative detection of tumor markers such as alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate specific antigen (PSA), and carcinoma antigen 125 (CA125) in serum, in which single immunosensor can oscillate independently with the frequency stability of +/-1 Hz (hertz) in air phase and +/-2 Hz in liquid phase. These response characteristics of Pz tumor marker multi-array immunoassay device such as time-cost, reproducibility and specificity, etc. were also investigated, respectively. The detection range for AFP, CEA, PSA and CA125 obtained by multi-array Pz immunosensor were 20-640 ng/ml, 1.5-30 microg/ml, 1.5-40 ng/ml and 5-150 IU/ml, respectively, with the coefficient of variance (CV) less than 5% and no cross-reactivates with other tumor markers in serum were observed. Application of the multi-array immunosensor to clinical samples demonstrated that results were in good agreement with chemiluminescence immunoassay (CLIA). Moreover, the multi-array Pz immunosensor could be regenerated to be reused for three cycles without appreciable loss of response activity. Therefore, the proposed multi-array immunoassay device based on Pz immunosensor provides a rapid, sensitive, specific, reusable, convenient and reliable alternative for the detection of tumor markers in clinical laboratory.  相似文献   

20.
The sensitivity and specificity of a polyethylene glycol terminated alkanethiol mixed self-assembled monolayers (SAM) on surface plasmon resonance (SPR) immunosensor to detect Escherichia coli O157:H7 is demonstrated. Purified monoclonal (Mabs) or polyclonal antibodies (PAbs) against E. coli O157:H7 were immobilized on an activated sensor chip and direct and sandwich assays were carried to detect E. coli O157:H7. Effect of Protein G based detection and effect of concentrations of primary and secondary antibodies in sandwich assay were investigated. The sensor surface was observed under an optical microscope at various stages of the detection process. The sensor could detect as low as 10(3)CFU/ml of E. coli O157:H7 in a sandwich assay, with high specificity against Salmonella Enteritidis. The detection limit using direct assay and Protein G were 10(6)CFU/ml and 10(4)CFU/ml, respectively. Results indicate that an alkanethiol SAM based SPR biosensor has the potential for rapid and specific detection of E. coli O157:H7, using a sandwich assay.  相似文献   