首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel water-compatible macroporous molecularly imprinted film (MIF) has been developed for rapid, sensitive, and label-free detection of small molecule testosterone in urine. The MIF was synthesized by photo copolymerization of monomers (methacrylic acid [MAA] and 2-hydroxyethyl methacrylate [HEMA]), cross-linker (ethylene glycol dimethacrylate, EGDMA), and polystyrene nanoparticles (PS NPs) in combination with template testosterone molecules. The PS NPs and template molecules were subsequently removed to form an MIF with macroporous structures and the specific recognition sites of testosterone. Incubation of artificial urine and human urine on the MIF and the non-imprinted film (NIF), respectively, indicated undetectable nonspecific adsorption. Accordingly, the MIF was applied on a surface plasmon resonance (SPR) sensor for the detection of testosterone in phosphate-buffered saline (PBS) and artificial urine with a limit of detection (LOD) down to 10−15 g/ml. To the best of our knowledge, the LOD is considered as one of the lowest among the SPR sensors for the detection of small molecules. The control experiments performed with analogue molecules such as progesterone and estradiol demonstrated the good selectivity of this MIF for sensing testosterone. Furthermore, this MIF-based SPR sensor shows high stability and reproducibility over 8 months of storage at room temperature, which is more robust than protein-based biosensors.  相似文献   

2.
Human serum 8-hydroxy-2′-deoxyguanosine (8-OHdG) was measured by HPLC-ECD method combined with solid phase extraction (SPE) developed by our group: (our proprietary kit, named 8-OHdG Pre-treatment Kit (TANITA Corporation)). The major interfering substances and proteins in serum were removed by 8-OHdG Pre-treatment Kit. This measurement method was highly reproducible (CV = 2.2–7.1%) and demonstrated the lower detection limit for control serum sample of less than 10 pg/ml without the sample evaporation. The other hand 8-OHdG concentration in serum for healthy people was in the range of 0–70 pg/ml (25.5 ± 13.8 pg/ml, n = 37). Secondary a relationship between the HPLC-ECD and ELISA methods was investigated. ELISA method could not detect 8-OHdG concentration in serum for healthy people, because the detection limit of 130 pg/ml was higher than the normal range for healthy people. These results show our SPE method has high sensitivity and quantitative accuracy for 8-OHdG analysis.  相似文献   

3.
A rapid, inexpensive, sensitive and specific HPLC-ECD method for the determination of lipoic acid in human plasma was developed and validated over the linearity range of 0.001–10 μg/ml using naproxen sodium as an internal standard (IS). Extraction of lipoic acid and IS from plasma (250 μl) was carried out with a simple one step liquid–liquid extraction using dichloromethane. Similarly solid-phase extraction was carried out using dichloromethane as extraction solvent. The separated organic layer was dried under the stream of nitrogen at 40 °C and the residue was reconstituted with the mobile phase. Complete separation of both lipoic acid and IS at 30 °C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 6 min using 0.05 M phosphate buffer (pH 2.5 adjusted with phosphoric acid):acetonitrile (50:50, v/v) as a mobile phase pumped at the rate of 1.5 ml/min using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification of lipoic acid were 200 pg/ml and 1 ng/ml, respectively. While on column limit of detection and limit of quantification of lipoic acid were 10 and 50 pg/ml, respectively. The absolute recoveries of lipoic acid with liquid–liquid and solid-phase extraction were 98.43, 95.65, 101.45, and 97.36, 102.73, 100.17% at 0.5, 1 and 5 μg/ml levels, respectively. Coefficient of variations for both intra-day and inter-day were between 0.28 and 4.97%. The method is validated and will be quite suitable for the analysis of lipoic acid in the plasma of human volunteers as well as patients with diabetes and cardiovascular diseases.  相似文献   

4.
A convenient, specific, and highly sensitive electrochemical immunosensor based on an indirect competitive assay format was developed for the determination of ochratoxin A (OTA), a common toxic contaminant in various kinds of agricultural products. The sensing substrate was prepared using a gold electrode modified with a self-assembled monolayer of 1,6-hexanedithiol that mediated the assembly of a gold colloid layer, which could enhance the surface loading of OTA-ovalbumin conjugate and improve the sensitivity in electrochemical readouts. After competition of the limited anti-OTA mouse monoclonal antibody between immobilized hapten and OTA analyte in sample solution, alkaline phosphatase (ALP)-labeled horse anti-mouse immunoglobulin G (IgG) antibody was selectively bound onto the surface of the electrode, affording an indicator for OTA concentration in the sample. Electrochemical response arising from the oxidation of enzymatic product of 1-naphthyl phosphate was observed to be inversely proportional to OTA concentration in the range from 10 pg/ml to 100 ng/ml with a detection limit as low as 8.2 pg/ml. Furthermore, a negligible matrix effect and good recoveries were obtained in the determination of corn samples, evidencing the feasibility of the proposed method for accurate determination of OTA in corn samples.  相似文献   

5.
Fentanyl and its major metabolite norfentanyl often occur in low doses in biological samples. Therefore, a highly sensitive liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed and fully validated. Sample preparation was performed on a mixed-mode cation exchange solid phase extraction (SPE) cartridge with an additional alkaline wash step to decrease matrix effects and thus increase sensitivity. Ionization of fentanyl and norfentanyl with electrospray ionization (ESI) was more efficient than atmospheric pressure chemical ionization (APCI). The use of a mobile phase of high pH resulted in higher ESI signals than the conventional low pH mobile phases. In the final method, gradient elution with 10 mM ammonium bicarbonate (pH 9) and methanol was performed. A comparison of columns with different internal diameter and/or smaller particles showed optimal resolution and sensitivity when an Acquity C18 column (1.7 μm, 2.1 mm × 50 mm) was used. Deuterium labeled internal standards were used, but with careful evaluation of their stability since loss of deuteriums was seen. With limits of detection of 0.25 pg/ml for fentanyl and 2.5 pg/ml for norfentanyl in urine and 5 pg/ml for fentanyl and norfentanyl in whole blood the presented method is highly appropriate for the analysis of fentanyl and norfentanyl in forensic urine and blood samples.  相似文献   

6.
Using a newly developed fluorescent nanoparticle (NP) that gives rise to a high-intensity and stable fluorescent light, a sensitive antibody (Ab) microarray assay system has been developed for specific detection of bioterrorism agents, as exemplified by ricin, cholera toxin (CT), and staphylococcal enterotoxin B (SEB). The Ab microarray uses a sandwich format that consists of capture Abs, analytes (toxins), biotinylated detection Abs, and avidin-conjugated NP. In all three cases, polyclonal Abs (pAbs) displayed superiority over monoclonal antibodies (mAbs) in capturing toxins on microarray slides even when the pAbs and mAbs had similar affinity as determined by enzyme-linked immunosorbent assay (ELISA). The detection system was successfully used to detect toxins spiked in milk, apple cider, and blood samples. We were able to detect ricin at 100 pg/ml in buffer and at 1 ng/ml in spiked apple cider or milk, whereas CT and SEB were detected at 10 pg/ml in buffer and 100 pg/ml in spiked apple cider or milk. High specificities were also demonstrated in the detection of mixed toxin samples with similar sensitivities. The matrix effect of blood samples on the detection of mixed toxins seems to be minimal when the toxin concentration is at or above 100 ng/ml. The current study highlights the significant role of pAb and NP in increasing selectivity and sensitivity of toxin detection in a microarray format.  相似文献   

7.
A novel and sensitive immunoassay method has been developed in which the conventional sandwich immunoassay and the highly sensitive DNA detection method, the Invader method, are combined. The signal amplification function of the latter method has been successfully used to enhance the sensitivity of the sandwich immunoassay. The new assay method may be called the Immuno-Invader assay. The assay format involves three important steps: (1) a target antigen is captured and flagged with a biotin-conjugated detection antibody by the sandwich method, (2) streptavidin and a biotin-conjugated oligonucleotide are added to form a complex with the detection antibody, and (3) the oligonucleotide in the complex is detected using the Invader method. The method was applied to the assay of human tumor necrosis factor-α (hTNF-α). Detection limits obtained were 0.1 pg/ml hTNF-α when a luminescent europium chelate was used with a time-resolved measurement mode, and 0.8 pg/ml when fluorescein was used with a normal prompt fluorescence measurement mode. On the other hand, the detection limit of a commercially available hTNF-α enzyme-linked immunosorbent assay that uses horseradish peroxidase was 3.5 pg/ml. These results demonstrate the feasibility and potential of the new assay method for highly sensitive immunoassay.  相似文献   

8.
We have developed a highly sensitive immunoassay using graphene nano platelets (GNPs) for the rapid detection of human lipocalin-2 (LCN2) in plasma, serum, and whole blood. It has the dynamic range, linear range, limit of detection, and analytical sensitivity of 0.6 to 5120, 80 to 2560, 0.7, and 1 pg/ml, respectively. It is the most sensitive assay for the detection of LCN2, which has 80-fold higher analytical sensitivity and 3-fold lesser immunoassay duration than the commercially available sandwich enzyme-linked immunosorbent assay (ELISA) kit. The functionalization of microtiter plate (MTP) with GNPs, dispersed in 3-aminopropyltriethoxysilane (APTES), provided the increased surface area that leads to higher immobilization density of capture antibodies. Moreover, the generation of free amino groups on MTP and GNPs by APTES enables the leach-proof covalent crosslinking of anti-human LCN2 capture antibody by its carboxyl groups using 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride (EDC) as the heterobifunctional crosslinker. The anti-LCN2 antibody-bound MTPs were highly stable given that they did not show any significant decrease in their functional activity when stored at 4 °C in 0.1 M phosphate-buffered saline (PBS) for 8 weeks. The developed immunoassay correlated well with the conventional ELISA, thereby demonstrating its high precision and potential utility for highly sensitive analyte detection in industrial and clinical settings.  相似文献   

9.
Here we report a simple, biomolecular-friendly protocol for the fabrication of a hydroxyapatite nanowires array (HANWA) biosensor of spatial positioning, large surface area, and abundant adsorbing sites and its application to cyanide sensing. The fabrication of HANWA is performed by template-assisted electrodeposition. The well-aligned hydroxyapatite nanoarray is composed of vertical nanowires with a diameter of approximately 200 nm and an average length of 1 μm. The electrochemical biosensor for the determination of cyanide through its inhibitory effect on horseradish peroxidase (HRP) encapsulated by chitosan (CHIT) on the platform of HANWA is demonstrated. The current organic-inorganic hybrid nanostructure provides excellent enzyme-substrate contact with enzyme activity well maintained. The densely distributed HANWA with large surface area and abundant adsorbing sites can provide a favorable electrochemical interface for the construction of electrochemical biosensor. A sensitive detection limit of 0.6 ng ml−1 was obtained for cyanide. The proposed CHIT-HRP/HANWA biosensor has the advantages of spatial resolution, high sensitivity, rapid regeneration, and fast response associated with individual nanowires. It broadens the possible applications of chemosensors and biosensors, and it offers an alternative method for toxic substance determination. The new device holds great promise for environmental and food industrial monitoring of toxins.  相似文献   

10.
Surface plasmon resonance (SPR) biosensor formats using gold nanoparticle or protein signal amplification for the sensitive assay of small molecules were developed using progesterone as a model compound. Progesterone was immobilized to a dextran surface in the Biacore biosensor through in situ covalent immobilization using an oligoethylene glycol linker attached to the 4 position of the steroid. This surface produced stable antibody binding for in excess of 1100 assay cycles. Using this surface, assays were developed for progesterone using 10- and 20-nm gold-streptavidin labels attached to biotinylated monoclonal antibody in both label prebinding and sequential binding formats. Prelabeling formats gave no signal enhancement but produced assays with limits of detection of 143 pg/ml, compared with approximately 1 ng/ml in previous studies. Sequential binding formats gave signal enhancements of 2.2-fold over the monoclonal antibody and a limit of detection of 23.1 pg/ml. It was found that secondary antibody labeling gave 8.1-fold signal enhancements and a limit of detection of 20.1 pg/ml, whereas use of secondary antibody-25 nm gold complexes provided more signal enhancement (13-fold) and a further improvement in limit of detection of 8.6 pg/ml.  相似文献   

11.
A simple and rapid analytical method is described for the simultaneous quantitative analysis of three different N-acylethanolamides in human biological samples: anandamide (AEA), oleoylethanolamide (OEA), and palmitoylethanolamide (PEA). The method is based on a new hybrid solid phase extraction-precipitation technology followed by ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) analysis using d4-AEA as the internal standard. The method is linear up to 100 ng/ml with a limit of quantitation of 50 pg/ml for AEA and 100 pg/ml for OEA and PEA. Good reproducibility, accuracy, and precision were demonstrated during the method validation. Application of this new methodology to the analysis of clinical study samples is presented.  相似文献   

12.
For the quantitative evaluation of low levels of an estriol metabolite of estriol (estriol-16-glucuronide (E3-16G)) in liquid media, we developed a simple and highly sensitive immunoassay using a surface plasmon resonance (SPR) biosensor which did not require any time-consuming sample pretreatment steps. E3-16G was conjugated to ovalbumin (OVA) through an oligoethylene glycol (OEG) linker to form protein conjugates (E3-16G-OEG-OVA), which were then immobilized on a carboxymethyl dextran-coated sensor chip via amine coupling to develop inhibition immunoassays. A limit of detection (LOD) of 76 pg/mL was achieved using a rabbit anti-sheep primary antibody as a binding agent. The detection limit was further improved by using synthesized gold colloids (15 nm) as high mass labels conjugated to the primary antibody. In this Au nanoparticle-enhanced assay, the concentration of E3-16G in aqueous samples could be determined in 7.5 min at a level as low as 14 pg/mL. In addition, the high stability of the E3-16G-OEG-OVA surface gave no obvious drop in antibody-binding capability after more than 1000 binding/regeneration cycles which significantly lowered the research cost.  相似文献   

13.
This paper presents a comparison between surface plasmon resonance (SPR) and capacitive immunosensors for a flow injection label-free detection of cancer antigen 125 (CA 125) in human serum. Anti-CA 125 was immobilized on gold surface through a self-assembled monolayer. Parameters affecting the responses of each system were optimized. Under optimal conditions, SPR provided a detection limit of 0.1 U ml−1 while 0.05 U ml−1 was obtained for the capacitive system. Linearity for SPR was between 0.1 and 40 U ml−1 and 0.05–40 U ml−1 for capacitive system. These immunosensors were applied to analyze CA 125 concentrations in human serum samples and compared with conventional enzyme linked fluorescent assay (ELFA). Both systems showed good agreement with ELFA (P < 0.05). Moreover, these immunosensors were very stable and provided good reproducible responses after regeneration, up to 32 times for SPR and 48 times for capacitive system with relative standard deviation lower than 4%. The SPR immunosensor provided advantages in term of fast response and real-time monitoring while capacitive immunosensor offered a sensitive and cost-effective method for CA 125 detection.  相似文献   

14.
A simple colorimetric biosensing technique based on the interaction of gold nanoparticles (AuNPs) with the aptamer was developed for detection of p53, a tumor suppressor protein, in the current study. Aggregation of AuNPs was induced by desorption of the p53 binding RNA aptamer from the surface of AuNPs as a result of the aptamer target interaction leading to the color change of AuNPs from red to purple. The detection limit of p53 protein by the colorimetric approach was 0.1 ng/ml after successful optimization of the amount of aptamer, AuNPs, salts, and incubation time. Furthermore, the catalytic activity of the aggregated AuNPs was greatly enhanced by chemiluminescence (CL) reaction, where the detection limit was enhanced to 10 pg/ml with a regression coefficient of R2 = 0.9907. Here the sensitivity was increased by 10-fold compared with the AuNP-based colorimetric method. Hence, the sensitivity of detection was increased by employing CL, by using the catalytic activity of aggregated AuNPs, on the luminol–hydrogen peroxide reaction. Thus, the combination of colorimetric and CL-based aptasensor can be of great advantage in increasing the sensitivity of detection for any target analyte.  相似文献   

15.
An electrochemical immunosensor was developed for the detection of hepatitis B surface antigen (HBsAg). The biotinylated hepatitis B surface antibody was immobilized on streptavidin magnetic nanoparticles and used for targeting the HBsAg. By the addition of horseradish peroxidase conjugated with secondary antibody (HRP–HBsAb), a sandwich-type immunoassay format was formed. Aminophenol as substrate for conjugated HRP was enzymatically changed into 3-aminophenoxazone (3-APZ). This electroactive enzymatic production (3-APZ) was transferred into an electrochemical cell and monitored by cyclic voltammetry. Under optimal conditions, the cathodic current response of 3-APZ, which was proportional to the HBsAg concentration, was measured by a glassy carbon electrode. The immunosensor response was linear toward HBsAg in the concentration range from 0.001 to 0.015 ng/ml with a detection limit of 0.9 pg/ml at a signal/noise ratio of 3.  相似文献   

16.
Obestatin regulates fluid and electrolyte homeostasis mainly by opposing the action of vasopressin (AVP). We measured plasma concentration of obestatin and AVP in patients with cardiorenal syndrome (CRS). Plasma AVP and obestatin concentration were measured in 34 patients with type II CRS. The data were compared to that in 31 patients with chronic kidney disease (CKD), 41 patients with chronic heart failure (CHF) and 30 healthy subjects. Obestatin was significantly higher in the patients with CRS (355.8 ± 85.1 pg/ml) than that in the healthy controls (212.3 ± 37.9 pg/ml, P < 0.01), the patients with CKD (246.7 ± 34.3 pg/ml, P < 0.01) and the patients with CHF (258.4 ± 112.1 pg/ml, P < 0.01). AVP was also significantly higher in the patients with CRS (65.1 ± 36.0 pg/ml) than that in the healthy controls (38.5 ± 20.1 pg/ml, P < 0.01), the patients with CKD (50.4 ± 24.8 pg/ml, P < 0.01) and the patients with CHF (54.6 ± 16.3 pg/ml, P < 0.01). Plasma concentration of obestatin was positively correlated with AVP plasma concentration in the overall analysis that included subjects from all disease categories (r = 0.219, P < 0.05), but not within the CRS group. Plasma obestatin and vasopressin were elevated in patients with CRS. Plasma obestatin concentration seemed to be positively correlated with plasma AVP.  相似文献   

17.
A sensitive, simple and rapid ultra fast liquid chromatography (UFLC)–ESI-MS/MS method was developed for the determination of 2-hydroxyflutamide in human plasma using tegafur as the internal standard. The plasma sample was pretreated with methanol for protein precipitation and the analytes were separated on an Ultimate C18 column (5 μm, 2.1 mm × 50 mm, MD, USA) with the mobile phase consisted of acetonitrile and water (2:1, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer under a negative multiple reaction-monitoring mode (MRM). The mass transition ion-pair was followed as m/z 290.90–204.8 for 2-hydroxyflutamide and 198.9–128.8 for tegafur. Linear calibration curves were obtained in the concentration range of 1.742–1452 ng/ml with a lower limit of quantification of 1.742 ng/ml. The intra- and inter-batch precision values were less than 8.1% and 5.6%, respectively. The established method was successfully applied to a bioequivalence study of two flutamide preparations (250 mg) in 20 healthy male volunteers.  相似文献   

18.
A sensitive and specific liquid chromatography–electrospray ionization-mass spectrometry (LC–ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid–liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C18 (5 μm, 150 mm × 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H]+ ions, m/z 373.9 → m/z184.0 for clebopride, m/z 359.9 → m/z71.5 for itopride. The method was validated over the concentration range of 69.530–4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from −8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride.  相似文献   

19.
A biosensor based on surface plasmon resonance (SPR) is developed for the detection of 2-hydroxybiphenyl (HBP). A monoclonal antibody against HBP (abbreviated hereafter as HBP-mAb) is developed and used for the detection of HBP by competitive SPR-based immunoassay and enzyme linked immunosorbent assay (ELISA) methods. A novel HBP-hapten compound, HBP-bovine serum albumin conjugate (HBP-BSA), derived by binding several HBP units with BSA by an aliphatic chain spacer is used in the development of antibody and for the functionalization of immunoprobes. HBP-BSA linked to the Au surface of the SPR sensor chip undergoes inhibitive immunoreaction with HBP-mAb in the presence of free HBP. The SPR-based immunoassay provides a rapid determination (response time: approximately 20 min) of the concentration of HBP in the range of 0.1-1000 ppb (ng/ml). Regeneration of the sensor chip is gained by treating the antibody-anchored SPR sensor chip with a pepsin solution (100 ppm (microg/ml); pH 2.0) for few minutes. The SPR sensor chip is reusable for the detection of HBP for more than 20 cycles with average loss of 0.35% reactivity per regeneration step. HBP concentration is determined as low as 0.1 and 3 ppb using the SPR sensor and ELISA measurements, respectively. The developed SPR sensor for HBP is free from interference by coexisting benzo[a]pyrene (BaP), 2,4-dichlorophenoxyacetic acid (2,4-D) and benz[a]anthracene; SPR angle shift obtained to the flow of HBP is almost same irrespective to the presence or absence of a same concentration of these carcinogenic polycyclic aromatic hydrocarbons together. The SPR sensor for HBP is proved to be applicable in simultaneous detection of HBP and BaP in parallel with another SPR sensor for BaP.  相似文献   

20.
A highly sensitive, specific and rapid electrochemical oxalate biosensor was constructed by covalently immobilizing sorghum leaf oxalate oxidase on carboxylated multiwalled carbon nanotubes and conducting polymer, polyaniline nanocomposite film electrodeposited over the surface of platinum (Pt) wire using N-ethyl-N′-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectrophotometry. The optimized oxalate biosensor showed linear response range of 8.4-272 μM with correlation coefficient of 0.93 and rapid response within 5 s at a potential of 0.4 V vs Ag/AgCl. The sensitivity was approximately 0.0113 μA/μM with a detection limit of 3.0 μM. Proposed oxalate biosensor was successfully applied to human urine sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号