首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved.  相似文献   

2.
This study combines finite element method and animal studies, aiming to investigate tissue remodelling processes around dental implants inserted into sika deer antler and to develop an alternative animal consuming model for studying bone remodelling around implants. Implants were inserted in the antlers and loaded immediately via a self-developed loading device. After 3, 4, 5 and 6 weeks, implants and surrounding tissue were taken out. Specimens were scanned by μCT scanner and finite element models were generated. Immediate loading and osseointegration conditions were simulated at the implant-tissue interface. A vertical force of 10 N was applied on the implant. During the healing time, density and Young’s modulus of antler tissue around the implant increased significantly. For each time point, the values of displacement, stresses and strains in the osseointegration model were lower than those of the immediate loading model. As the healing time increased, the displacement of implants was reduced. The 3-week immediate loading model (9878 ± 1965 μstrain) illustrated the highest strains in the antler tissue. Antler tissue showed similar biomechanical properties as human bone in investigating the bone remodelling around implants, therefore the use of sika deer antler model is a promising alternative in implant biomechanical studies.  相似文献   

3.
In this paper, a qualitative comparison between two types of dental implants with respect to their behaviour under immediate loading is presented. This analysis has been carried out using the finite element method. Since micromotions (and not the load) are responsible of the appearance of a fibrous interface avoiding osseointegration, the relative displacement between the bone surface and the implant has been the main variable analyzed at different loading states and for the two implant types here considered. The implants analyzed differ in their mechanical behavior: rigid or resilient. Their main difference lies in the joining between the different pieces that make up the dental system. While in the rigid implant all the pieces are screwed, in the resilient implant a relative displacement between the pieces is allowed, with the additional introduction of a silicone gasket that acts like the periodontal ligament. Both implants were considered with a similar geometry and under two different loading scenarios, one equivalent to the force of chewing applied to a molar and another which corresponds to a premolar. For the resilient implant, a hyperelastic behaviour for the silicone and contact conditions between the different mobile parts of the implant are considered. The displacements of the emerging-body in both designs are also compared with the values obtained by several authors. However, the results show that both implants fulfill the constraint of the immediate loading protocol. The micromotions of the resilient implant are lower to those of the rigid one, favouring therefore a good osseointegration process while keeping the stresses in the implant under admissible maximum values.  相似文献   

4.
Zou D  He J  Zhang K  Dai J  Zhang W  Wang S  Zhou J  Huang Y  Zhang Z  Jiang X 《PloS one》2012,7(3):e32355
The presence of insufficient bone volume remains a major clinical problem for dental implant placement to restore the oral function. Gene-transduced stem cells provide a promising approach for inducing bone regeneration and enhancing osseointegration in dental implants with tissue engineering technology. Our previous studies have demonstrated that the hypoxia-inducible factor-1α (HIF-1α) promotes osteogenesis in rat bone mesenchymal stem cells (BMSCs). In this study, the function of HIF-1α was validated for the first time in a preclinical large animal canine model in term of its ability to promote new bone formation in defects around implants as well as the osseointegration between tissue-engineered bone and dental implants. A lentiviral vector was constructed with the constitutively active form of HIF-1α (cHIF). The ectopic bone formation was evaluated in nude mice. The therapeutic potential of HIF-1α-overexpressing canine BMSCs in bone repair was evaluated in mesi-implant defects of immediate post-extraction implants in the canine mandible. HIF-1α mediated canine BMSCs significantly promoted new bone formation both subcutaneously and in mesi-implant defects, including increased bone volume, bone mineral density, trabecular thickness, and trabecular bone volume fraction. Furthermore, osseointegration was significantly enhanced by HIF-1α-overexpressing canine BMSCs. This study provides an important experimental evidence in a preclinical large animal model concerning to the potential applications of HIF-1α in promoting new bone formation as well as the osseointegration of immediate implantation for oral function restoration.  相似文献   

5.
The failure of orthopedic and dental implants has been attributed mainly to loosening of the implant from host bone, which may be due to weak bonding of the implant material to bone tissue. Titanium (Ti) is used in the field of orthopedic and dental implants because of its excellent biocompatibility and outstanding mechanical properties. Therefore, in the field of materials science and tissue engineering, there has been extensive research to immobilize bioactive molecules on the surface of implant materials in order to provide the implants with improved adhesion to the host bone tissue.In this study, chemically active functional groups were introduced on the surface of Ti by a grafting reaction with heparin and then the Ti was functionalized by immobilizing alendronate onto the heparin-grafted surface. In the MC3T3-E1 cell osteogenic differentiation study, the alendronate-immobilized Ti substrates significantly enhanced alkaline phosphatase activity (ALP) and calcium content. Additionally, nuclear factor kappa B ligand (RANKL)-induced osteoclast differentiation of RAW264.7 cells was inhibited with the alendronate-immobilized Ti as confirmed by TRAP analysis. Real time PCR analysis showed that mRNA expressions of osteocalcin and osteopontin, which are markers for osteogenesis, were upregulated in MC3T3-E1 cells cultured on alendronate-immobilized Ti. The mRNA expressions of TRAP and Cathepsin K, markers for osteoclastogenesis, in RAW264.7 cells cultured on alendronate-immobilized Ti were down-regulated. Our study suggests that alendronate-immobilized Ti may be a bioactive implant with dual functions to enhance osteoblast differentiation and to inhibit osteoclast differentiation simultaneously.  相似文献   

6.
The aims of this study were to examine the effect of implant neck design and cortical bone thickness using 3D finite element analysis and to analyse the stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants for a type IV bone and maxillary segments were created. Various parameters were considered, including the osseointegration condition, loading direction and cortical bone thickness. Micromotion and principal stresses were used to evaluate the failure of osseointegration and bone overloading, respectively. It was found that the maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as cortical bone thickness increases. The cortical bone thickness should be measured before surgery to help select a proper implant. In the early stage of implantation, the horizontal loading component induces stress concentration in bone around the implant neck more easily than does the vertical loading component, and this may result in crestal bone loss.  相似文献   

7.
This paper proposes a rapid inverse analysis approach based on the reduced-basis method (RBM) and neural network (NN) to identify the “unknown” elastic modulus (Young's modulus) of the interfacial tissue between a dental implant and the surrounding bones. In the present RBM–NN approach, a RBM model is first built to compute displacement responses of dental implant-bone structures subjected to a harmonic loading for a set of “assumed” Young's moduli. The RBM model is then used to train a NN model that is used for actual inverse analysis in real-time. Actual experimental measurements of displacement responses are fed into the trained NN model to inversely determine the “true” elastic modulus of the interfacial tissue. As an example, a physical model of dental implant-bone structure is built and inverse analysis is conducted to verify the present RBM–NN approach. Based on numerical simulation and actual experiments, it is confirmed that the identified results are very accurate, reliable, and the computational saving is very significant. The present RBM–NN approach is found robust and efficient for inverse material characterizations in noninvasive and/or nondestructive evaluations.  相似文献   

8.
钛的优良特性早已被公认为首选牙用种植材料,其表面氧化膜是形成骨结合的关建。为了进一步增加其耐腐蚀性和生物相容性,人们采取了多种方式进行表面处理,最终达到在植入体的不同部位产生不同的粗糙表面,以利于不同细胞在不同地方的附着,增加其生物活性。同时,达到避免各种污染物对纯钛种植体影响的目的。近年来钛种植体材料表面处理已经成为研究热点,本文就表面处理的方法进行综述。  相似文献   

9.
Abstract

The success of dental implant treatment depends on the healing of both hard and soft tissues. While osseointegration provides initial success, the biological seal of the peri-implant soft tissue is crucial for maintaining the long term success of implants. Most studies of the biological seal of peri-implant tissues are based on animal or monolayer cell culture models. To understand the mechanisms of soft tissue attachment and the factors affecting the integrity of the soft tissue around the implants, it is essential to obtain good quality histological sections for microscopic examination. The nature of the specimens, however, which consist of both metal implant and soft peri-implant tissues, poses difficulties in preparing the specimens for histomorphometric analysis of the implant-soft tissue interface. We review various methods that have been used for the implant-tissue interface investigation with particular focus on the soft tissue. The different methods are classified and the advantages and limitations of the different techniques are highlighted.  相似文献   

10.
Stability of an implant is defined by its ability to undergo physiological loading–unloading cycles without showing excessive tissue damage and micromotions at the interface. Distinction is usually made between the immediate primary stability and the long-term, secondary stability resulting from the biological healing process. The aim of this research is to numerically investigate the effect of initial implantation press-fit, bone yielding, densification and friction at the interface on the primary stability of a simple bone–implant system subjected to loading–unloading cycles. In order to achieve this goal, human trabecular bone was modeled as a continuous, elasto-plastic tissue with damage and densification, which material constants depend on bone volume fraction and fabric. Implantation press-fit related damage in the bone was simulated by expanding the drilled hole to the outer contour of the implant. The bone–implant interface was then modeled with unilateral contact with friction. The implant was modeled as a rigid body and was subjected to increasing off-axis loading cycles. This modeling approach is able to capture the experimentally observed primary stability in terms of initial stiffness, ultimate force and progression of damage. In addition, it is able to quantify the micromotions around the implant relevant for bone healing and osseointegration. In conclusion, the computationally efficient modeling approach used in this study provides a realistic structural response of the bone–implant interface and represents a powerful tool to explore implant design, implantation press-fit and the resulting risk of implant failure under physiological loading.  相似文献   

11.
The aim of this study is to predict the evolution of the resonance frequency of the bone-implant interface in a dental implant by means of finite element simulation. A phenomenological interface model able to simulate the mechanical effects of the osseointegration process at the bone-implant interface is applied and compared with some experimental results in rabbits. An early stage of slow bone ingrowth, followed by a faster osseointegration phase until final stability is predicted by the simulations. The evolution of the resonance frequency of the implant and surrounding tissues along the simulation period was also obtained, observing a 3-fold increase in the first principal frequency. These findings are in quantitative agreement with the experimental measurements and suggest that the model can be useful to evaluate the influence of mechanical factors such as implant geometry or implant loading on the indirect evaluation of the process of implant osseintegration.  相似文献   

12.
Osseointegration of implant provides a stable support for the prosthesis under functional loads. The timing of loading is a critical parameter that can govern the success of the osseointegration of implant. However, it is not clear whether the early loading can affect the success of osseointegration, or whether the no-loading healing period can be shortened. This paper presents an animal study conducted to investigate how external loads influence the osseointegration at the initial stage of healing. Titanium implants were inserted into the goat tibia laterally, and different axial loadings were applied to the implants in 4 weeks after surgery. After the 2 weeks period of early loading, animals were sacrificed and the tibia bones with the implants were cut off from the bodies. Then mechanical test was employed to find out the differences in the pull-out force, and shear strength at the bone-implant interface between the non-loaded and the loaded implants. The implant-bone interfaces were analyzed by histomorphometric method, SEM (scanning electron micrograph) and EDS (energy density spectrum). The results indicated that the bone-implant interface did not well integrate 4 weeks after surgery, and the fibrous tissue could be found at the interfaces of the specimens without loadings. While the results of loaded specimens with 10 N axial force showed that that parts of the interface were well integrated, indicating that the early mild loading may play a positive role in the process of the osseointegration. The results support that a certain range of external loading would influence the process of osseointegration, and appropriate mechanical loading can be applied to shorten the osseointegration period after surgery. Supported by the National Natural Science Foundation of China (Grant Nos. 30370376, 10529202 and 10672015).  相似文献   

13.
We consider a non-standard design for a fixed dental implant, incorporating a soft layer which simulates the presence of the periodontal ligament (PDL). Instead of being aimed at causing an a priori defined stress/strain field within the surrounding bone, upon loading, such a design simply tries to better reproduce the natural tooth–PDL configuration. To do this, the mechanical properties of the internal layer match those of the PDL, determined experimentally to be strongly nonlinear. Three-dimensional finite element analyses show that the presence of such a layer produces (i) a prosthesis mobility very similar to that of a healthy tooth, for several loading conditions, and (ii) a stress/strain distribution substantially different from that arising, upon loading, around a conventional implant. The lack of knowledge of the real mechanical fields existing, under loading, in the bone around a healthy tooth makes it very difficult to state that the stress distribution produced by the modified implant is “better” than that produced by the standard one. Nevertheless, the comparison of the results obtained here, with those of previous refined analyses of the tooth–PDL–bone system, indicates that the modified implant tends to produce a stress distribution in the bone, upon loading, closer to “natural” than that given by the standard one, within the limits imposed by the presence of threads coupling the implant with the bone.  相似文献   

14.
《Organogenesis》2013,9(3):151-157
The field of tissue engineering has made considerable strides since it was first described in the late 1980s. The advent and subsequent boom in stem cell biology, emergence of novel technologies for biomaterial development, and further understanding of developmental biology have contributed to this accelerated progress. However, continued efforts to translate tissue engineering strategies into clinical therapies have been hampered by the problems associated with scaling up laboratory methods to produce large, complex tissues. The significant challenges faced by tissue engineers include the production of an intact vasculature within a tissue-engineered construct and recapitulation of the size and complexity of a whole organ. Here we review the basic components necessary for bioengineering organs – biomaterials, cells and bioactive molecules–and discuss various approaches for augmenting these principles to achieve organ level tissue engineering. Ultimately, the successful translation of tissue-engineered constructs into everyday clinical practice will depend upon the ability of the tissue engineer to “scale up” every aspect of the research and development process.  相似文献   

15.
The main reason for the revision of total hip replacements is aseptic loosening, caused by stress shielding and wear particle induced osteolysis. In order to detect an implant loosening early, the osseointegration of endoprosthetic implants must be measured exactly. Currently applied diagnostic methods, such as standard radiographs and clinical symptomatology, often result in an imprecise diagnosis. A novel radiation-free method to improve the diagnostic investigation of implant loosening is presented. The osseointegration of an implant can be identified using mechanical magnetic sensors (oscillators), which impinge on small membranes inside an implant component, e.g., the femoral hip stem. The maximum velocity after impingement of the oscillator depends on the osseointegration of the implant. Excitation of the oscillator is realized by a coil outside the human body. Another external coil is used to detect the velocity of the oscillator. To demonstrate the principle of the novel loosening sensor, an overdimensioned test device was designed to measure simulated loosening phases in the first experimental tests with different material layers. The overdimensioned test device of the loosening sensor showed significant differences in the various phases of fixation. Analysis of the membrane without any material layer in the case of advanced loosening resulted in a 23% higher maximum velocity compared to an attached artificial bone layer. Based on these preliminary results, the sensor system shows potential for the detection of implant loosening. Moreover, the proposed system could be used in experimental applications to determine the quality of bioactive coatings and new implant materials.  相似文献   

16.
The long-term stability and success of orthopedic implants depend on the osseointegration process, which is strongly influenced by the biomaterial surface. A promising approach to enhance implant integration involves the modification of the surface of the implant by means of polymers that mimic the natural components of the extracellular matrix, for example, polysaccharides. In this study, methacrylate thermosets (bisphenol A glycidylmethacrylate/triethyleneglycol dimethacrylate), a widely used composition for orthopedic and dental applications, have been coated by electrostatic deposition of a bioactive chitosan-derivative. This polysaccharide was shown to induce osteoblasts aggregation in vitro, to stimulate cell proliferation and to enhance alkaline phosphatase activity. The coating deposition was studied by analyzing the effect of pH and ionic strength on the grafting of the polysaccharide. Contact angle studies show that the functionalized material displays a higher hydrophilic character owing to the increase of surface polar groups. The mechanical properties of the coating were evaluated by nanoindentation studies which point to higher values of indentation hardness and modulus (E) of the polysaccharide surface layer, while the influence of cyclic stress on the construct was assessed by fatigue tests. Finally, in vivo tests in minipigs showed that the polysaccharide-based implant showed a good biocompatibility and an ability for osseointegration at least similar to that of the titanium Ti6Al4V alloy with roughened surface.  相似文献   

17.
Thirteen patients with large ameloblastomas of the mandible underwent segmental mandibulectomy and immediate reconstruction, with simultaneous placement of osseointegrated implants. All patients received palatal mucosal grafts around the dental implants 6 to 10 months after surgical treatment and received implant-supported prostheses another 1 to 2 months later. There were five female and eight male patients, with a mean age of 32 years (range, 17 to 50 years). The mean length of the mandibular defect was 8.8 cm (range, 5 to 13 cm). All free fibula flap procedures were successful, with no reexplorations or partial flap losses. There was no clinical or radiographic evidence of failure during the osseointegration process for any implant. With functional occlusal loading, the marginal bone loss around the implants was less than 1.5 mm in a mean follow-up period of 40 months (range, 18 to 70 months). There were no recurrences during that time. The technique described allows improved access to the bone at the time of reconstruction, immediate assessment of alveolar ridge relationships, and accurate fixation of the implant-fibula construct. The advantages of this procedure include a reduced risk of recurrence with segmental resection, reliable mandibular reconstruction, and reduction of the number of surgical procedures, allowing full oral rehabilitation in a shorter time. It is concluded that segmental mandibulectomy and immediate vascularized fibula osteoseptocutaneous flap reconstruction, with simultaneous placement of osseointegrated implants, represent an ideal treatment method for large ameloblastomas of the mandible.  相似文献   

18.
The assessment of the behavior of immediately loaded dental implants using biomechanical methods is of particular importance. The primary goal of this investigation is to optimize the function of the implants to serve for immediate loading. Animal experiments on reindeer antlers as a novel animal model will serve for investigation of the bone remodeling processes in the implant bed. The main interest is directed towards the time and loading-dependant behavior of the antler tissue around the implants. The aim and scope of this work was to design an autonomous loading device that has the ability to load an inserted implant in the antler with predefined occlusal forces for predetermined time protocols. The mechanical part of the device can be attached to the antler and is capable of cyclically loading the implant with forces of up to 100 N. For the calibration and testing of the loading device a biomechanical measuring system has been used. The calibration curve shows a logarithmic relationship between force and motor current and is used to control the force on the implant. A first test on a cast reindeer antler was performed successfully.  相似文献   

19.
An intra-oral hydraulic system for controlled loading of dental implants   总被引:2,自引:0,他引:2  
This study reports a method for controlling loads on an in vivo dental implant and its application for the investigation of early loading versus delayed loading of dental implants. The method was developed for the purpose of studying an ongoing hypothesis that amounts to bone loss around dental implants are related to mechanical-mediated adaptation of the alveolar bone. Using a customized intra-oral hydraulic system, the daily loading over a dental implant has been completed and recorded for six Sinclair swine. Each pig had a 5-month duration implant loading. During the experiments (loading), no analgesic treatment was supplied. The mean of the in vivo daily loadings was confirmed through an in vitro bench test after each animal was euthanized. Variations of the averaged loading input among the six animals were smaller than 10%. Preliminary data produced by the model suggests that cervical bone loss is less for early loading than for delayed loading. The current system is expected to provide a useful load control model for the study of alveolar bone adaptation around dental implants in relation to various loadings.  相似文献   

20.
Despite the ongoing improvement in implant characteristics, bone intrinsic potential for regeneration may be stimulated with adjuvant therapies to standard surgical procedures, as it is important to achieve the best possible implant osseointegration into the adjacent bone and to ensure therefore long-term implant stability. For this purpose various pharmacological, biological or biophysical modalities have been developed, such as bone grafting materials, pharmacological agents, growth factors and bone morphogenetic proteins. Biophysical stimulation of osseointegration includes two non-invasive and safe methods that have been initially developed to enhance fracture healing: pulsed electromagnetic fields (PEMFs) and lowintensity ultrasounds (LIPUS), for which most studies confirm their beneficial effects. The present paper is an overview of bone-implant osseointegration and the current trends on its enhancement, focusing mainly on the two methods of biophysical stimulation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏