首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
As a guide in distinguishing between organic and functional systolic murmurs, five characteristics of a murmur should always be noted, namely, (a) the location of maximal intensity of the murmur; (b) the intensity of the murmur itself; (c) the character of the murmur, that is, whether it is blowing, rumbling, rough or harsh; (d) the transmission of the murmur; and (e) the duration of the murmur and its time within the cardiac cycle. Functional systolic murmurs may be found at any of the "valve areas," are usually faint to moderately loud, are usually soft and blowing in quality, are usually only slightly transmitted, and are usually not heard immediately following the first heart sound. In doubtful cases, those in which history and physical examination alone are not sufficient to make a diagnosis of functional systolic murmur, further studies should be undertaken to determine the presence or absence of organic heart disease. Until a diagnosis of organic heart disease can be made with reasonable certainty, there should be no restriction of activity imposed, because of the likelihood of the development of cardiac neurosis in the patient.  相似文献   

3.
4.
Congestive heart failure with preserved left ventricular systolic function has emerged as a growing epidemic medical syndrome in developed countries, which is characterized by high morbidity and mortality rates. Rapid and accurate diagnosis of this condition is essential for optimizing the therapeutic management. The diagnosis of congestive heart failure is challenging in patients presenting without obvious left ventricular systolic dysfunction and additional diagnostic information is most commonly required in this setting. Comprehensive Doppler echocardiography is the single most useful diagnostic test recommended by the ESC and ACC/AHA guidelines for assessing left ventricular ejection fraction and cardiac abnormalities in patients with suspected congestive heart failure, and non-invasively determined basal or exercise-induced pulmonary capillary hypertension is likely to become a hallmark of congestive heart failure in symptomatic patients with preserved left ventricular systolic function. The present review will focus on the current clinical applications of spectral tissue Doppler echocardiography used as a reliable noninvasive surrogate for left ventricular diastolic pressures at rest as well as during exercise in the diagnosis of heart failure with preserved left ventricular systolic function. Chronic congestive heart failure, a disease of exercise, and acute heart failure syndromes are characterized by specific pathophysiologic and diagnostic issues, and these two clinical presentations will be discussed separately.  相似文献   

5.
6.
7.
8.
9.
Systolic time intervals are commonly used to identify changes in ventricular function. The method described facilitates measurement and calculation of many such intervals. This method utilizes a printed polygraph recording of electrocardiogram, phonocardiogram, and carotid pulse contour; a digitizing device for reading the necessary coordinates from the record; and a minicomputer for calculation of the intervals and for data analysis. Intervals related to approximately 100 pulse beats can be read, calculated, printed in chart and graph form, and subjected to some analyses in about an hour.  相似文献   

10.
This paper presents the algorithm and technical aspects of an intelligent diagnostic system for the detection of heart murmurs. The purpose of this research is to address the lack of effectively accurate cardiac auscultation present at the primary care physician office by development of an algorithm capable of operating within the hectic environment of the primary care office. The proposed algorithm consists of three main stages. First; denoising of input data (digital recordings of heart sounds), via Wavelet Packet Analysis. Second; input vector preparation through the use of Principal Component Analysis and block processing. Third; classification of the heart sound using an Artificial Neural Network. Initial testing revealed the intelligent diagnostic system can differentiate between normal healthy heart sounds and abnormal heart sounds (e.g., murmurs), with a specificity of 70.5% and a sensitivity of 64.7%.  相似文献   

11.

Background

Heart failure (HF) is a complex clinical syndrome characterized by impaired cardiac function and poor exercise tolerance. Enhanced inflammation is associated with worsening outcomes in HF patients and may play a direct role in disease progression. Interleukin-1β (IL-1β) is a pro-inflammatory cytokine that becomes chronically elevated in HF and exerts putative negative inotropic effects.

Methods and Results

We developed a model of IL-1β-induced left ventricular (LV) dysfunction in healthy mice that exhibited a 32% reduction in LV fractional shortening (P<0.001) and a 76% reduction in isoproterenol response (P<0.01) at 4 hours following a single dose of IL-1β 3 mcg/kg. This phenotype was reproducible in mice injected with plasma from HF patients and fully preventable by pretreatment with IL-1 receptor antagonist (anakinra). This led to the design and conduct of a pilot clinical to test the effect of anakinra on cardiopulmonary exercise performance in patients with HF and evidence of elevated inflammatory signaling (n = 7). The median peak oxygen consumption (VO2) improved from 12.3 [10.0, 15.2] to 15.1 [13.7, 19.3] mL·kg–1·min–1 (P = 0.016 vs. baseline) and median ventilator efficiency (VE/VCO2 slope) improved from 28.1 [22.8, 31.7] to 24.9 [22.9, 28.3] (P = 0.031 vs. baseline).

Conclusions

These findings suggest that IL-1β activity contributes to poor exercise tolerance in patients with systolic HF and identifies IL-1β blockade as a novel strategy for pharmacologic intervention.

Trial Registration

ClinicalTrials.gov NCT01300650  相似文献   

12.
13.
14.
Vitamin E and heart disease: basic science to clinical intervention trials   总被引:19,自引:0,他引:19  
A review is presented of studies on the effects of vitamin E on heart disease, studies encompassing basic science, animal studies, epidemiological and observational studies, and four intervention trials. The in vitro, cellular, and animal studies, which are impressive both in quantity and quality, leave no doubt that vitamin E, the most important fat-soluble antioxidant, protects animals against a variety of types of oxidative stress. The hypothesis that links vitamin E to the prevention of cardiovascular disease (CVD) postulates that the oxidation of unsaturated lipids in the low-density lipoprotein (LDL) particle initiates a complex sequence of events that leads to the development of atherosclerotic plaque. This hypothesis is supported by numerous studies in vitro, in animals, and in humans. There is some evidence that the ex vivo oxidizability of a subject's LDL is predictive of future heart events. This background in basic science and observational studies, coupled with the safety of vitamin E, led to the initiation of clinical intervention trials. The three trials that have been reported in detail are, on balance, supportive of the proposal that supplemental vitamin E can reduce the risk for heart disease, and the fourth trial, which has just been reported, showed small, but not statistically significant, benefits. Subgroup analyses of cohorts from the older three trials, as well as evidence from smaller trials, indicate that vitamin E provides protection against a number of medical conditions, including some that are indicative of atherosclerosis (such as intermittent claudication). Vitamin E supplementation also produces an improvement in the immune system and protection against diseases other than cardiovascular disease (such as prostate cancer). Vitamin E at the supplemental levels being used in the current trials, 100 to 800 IU/d, is safe, and there is little likelihood that increased risk will be found for those taking supplements. About one half of American cardiologists take supplemental vitamin E, about the same number as take aspirin. In fact, one study suggests that aspirin plus vitamin E is more effective than aspirin alone. There are a substantial number of trials involving vitamin E that are in progress. However, it is possible, or even likely, that each condition for which vitamin E provides benefit will have a unique dose-effect curve. Furthermore, different antioxidants appear to act synergistically, so supplementation with vitamin E might be more effective if combined with other micronutrients. It will be extremely difficult to do trials that adequately probe the dose-effect curve for vitamin E for each condition that it might affect, or to do studies of all the possible combinations of other micronutrients that might act with vitamin E to improve its effectiveness. Therefore, the scientific community must recognize that there never will be a time when the science is "complete." At some point, the weight of the scientific evidence must be judged adequate; although some may regard it as early to that judgement now, clearly we are very close. In view of the very low risk of reasonable supplementation with vitamin E, and the difficulty in obtaining more than about 30 IU/day from a balanced diet, some supplementation appears prudent now.  相似文献   

15.
Background A growing number of patients with end-stage heart failure undergo implantation of ventricular assist devices as a bridge to heart transplantation. Objectives In this study we investigated whether functional and haemodynamic recovery after implantation is sufficient to warrant the use of them as long-term alternative to heart transplantation. Methods We compared peak VO2 of a group of patients three months after implantation of a ventricular assist device and three months after heart transplantation. Furthermore, we analysed the degree of haemodynamic recovery, by comparing plasma levels of BNP and creatinine before and after implantation of the device. Results After implantation of a ventricular assist device, exercise capacity improved considerably; three months after implantation peak VO2 was 20.0±4.9 ml/kg/min (52% of predicted for age and gender). After heart transplantation exercise capacity improved even further; 24.0±3.9 ml/ kg/min (62% of predicted for age and gender) (p<0.001). In the three months after implantation, BNP plasma levels decreased from 570±307 pmol/l to 31±25 pmol/l and creatinine levels decreased from 191±82 μmol/l to 82±25 μmol/l, indicating significant unloading of the ventricles and haemodynamic recovery. Conclusion With regard to functional and haemodynamic recovery, the effect of implantation of a ventricular assist device is sufficient to justify its use as an alternative to heart transplantation. (Neth Heart J 2008;16:41-6.)  相似文献   

16.
Changes in muscle fiber orientation across the wall of the left ventricle (LV) cause the apex of the heart to turn 10-15 deg in opposition to its base during systole and are believed to increase stroke volume and lower wall stress in healthy hearts. Studies show that cardiac torsion is sensitive to various disease states, which suggests that it may be an important aspect of cardiac function. Modern imaging techniques have sparked renewed interest in cardiac torsion dynamics, but no work has been done to determine whether mechanically augmented apical torsion can be used to restore function to failing hearts. In this report, we discuss the potential advantages of this approach and present evidence that turning the cardiac apex by mechanical means can displace a clinically significant volume of blood from failing hearts. Computational models of normal and reduced-function LVs were created to predict the effects of applied apical torsion on ventricular stroke work and wall stress. These same conditions were reproduced in anesthetized pigs with drug-induced heart failure using a custom apical torsion device programmed to rotate over various angles during cardiac systole. Simulations of applied 90 deg torsion in a prolate spheroidal computational model of a reduced-function pig heart produced significant increases in stroke work (25%) and stroke volume with reduced fiber stress in the epicardial region. These calculations were in substantial agreement with corresponding in vivo measurements. Specifically, the computer model predicted torsion-induced stroke volume increases from 13.1 to 14.4 mL (9.9%) while actual stroke volume in a pig heart of similar size and degree of dysfunction increased from 11.1 to 13.0 mL (17.1%). Likewise, peak LV pressures in the computer model rose from 85 to 95 mm Hg (11.7%) with torsion while maximum ventricular pressures in vivo increased in similar proportion, from 55 to 61 mm Hg (10.9%). These data suggest that: (a) the computer model of apical torsion developed for this work is a fair and accurate predictor of experimental outcomes, and (b) supra-physiologic apical torsion may be a viable means to boost cardiac output while avoiding blood contact that occurs with other assist methods.  相似文献   

17.
Wilson disease (WD) is an autosomal recessive disorder of copper metabolism characterized by hepatic and/or neurological damage. More than 300 mutations in gene ATP7B causing this defect have been reported. The data on correlation between WD patient genotypes and clinical presentation are controversial. In this paper, the results of ATP7B mutation analysis by testing for mutation H1069Q and direct sequencing of six exons together with the clinical data of 40 Latvian WD patients are presented. Two previously described and two novel mutations as well as one previously reported polymorphism were identified. The H1069Q mutation was present at 52.5% of the disease alleles. One individual among 157 healthy Latvians was also found to be a mutation H1069Q carrier. The estimated incidence of WD in Latvia is ∼1 in 25600. Wide clinical variability was observed among individuals with the same ATP7B genotype, thus supporting the suggestion that modifying factors play an additional role in the pathogenesis of WD. An algorithm for the diagnosis of WD, including testing for mutation H1069Q, is recommended for the populations where mutation H1069Q accounts for 50% of WD alleles or more. The text was submitted authors English.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号