首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective and sensitive method for analysis of perfluorooctanoic acid (PFOA) in human serum and plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. A simple, automated sample preparation procedure, involving extraction of the target analyte with acetonitrile on protein precipitation media in a 96-well plate format was developed, allowing efficient handling of large numbers of samples. The proposed method uses the calibration standards prepared in a surrogate matrix (rabbit serum or plasma) and (13)C-labeled PFOA as the internal standard to account for matrix effects, instrument drift, and extraction efficiency. Human serum and plasma could not be used for matrix matching of calibration standards as endogenous levels of PFOA observed in the control human serum and plasma significantly exceeded the targeted lower limit of quantitation (LLOQ) of the method. Precision and accuracy of the method were demonstrated by analysis of rabbit serum and plasma control samples fortified at 0.5, 5, and 40 ng/mL PFOA and human serum and plasma fortified at 1.0, 5.0, 40 ng/mL PFOA. The LLOQ of 0.5 ng/mL PFOA was experimentally demonstrated for rabbit and human serum and plasma. Within-day precision and accuracy, short-term stability, freeze-thaw stability, equivalence of response between PFOA and APFO (the ammonium salt of PFOA), and dilution of concentrated samples were also investigated. The results of the validation experiments comply with the precision and accuracy limits defined by the FDA guidance document: "Guidance for Industry, Bioanalytical Method Validation", May 2001.  相似文献   

2.
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration.  相似文献   

3.
An analytical method was developed and validated to determine Formoterol in human serum in the range from 0.40 to 100.24 pg/mL by high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) due to the lack of efficient methods to determine very low levels of Formoterol in serum and plasma. Serum was diluted by water and mixed with the internal standard (d6-Formoterol). Formoterol and internal standard were extracted using a cation-exchange solid phase column (SCX-3). After eliminating endogenous serum constituents through washing steps with water and methanol, elution took place using methanol/ammonia. After evaporation of the elution liquid the residue was redissolved and analyzed by HPLC-MS/MS with electrospray ionisation (ESI) in positive mode. A gradient between 10 mM ammonium formate and acetonitrile was used. The inter-batch precision of the calibration standards ranged from 1.55% to 9.01%. The inter-batch accuracy of the calibration standards ranged from 93.37% to 107.30%. The lower limit of quantitation (LLOQ, 0.40 pg/mL) had a precision of 19.67% and an accuracy of 96.78%. Comparable results were obtained for quality control samples. Stability in human serum was given over three freeze/thaw cycles and 2h at room temperature. Formoterol in human serum was stable for at least 6 months below -20 degrees C. This method has been used widely for quantifying Formoterol after inhalation of 9-36 microg of the drug by volunteers. A cross validation with human plasma versus serum was performed after this method was successfully validated in human serum.  相似文献   

4.
Dialkylphosphates (DAP) are urinary markers of the exposure to organophosphates pesticides. The aim of this study was to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitative determination of the following DAP: dimethylphosphate (DMP), dimethythiophosphate (DMTP), dimethyldithiophosphate (DMDTP), diethylphosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP). Dibutylphosphate (DBP) was used as internal standard. This method was based on a liquid-liquid extraction procedure, a chromatographic separation using an Inertsil ODS3 C18 column and mass spectrometric detection in the negative ion, multiple reaction monitoring (MRM) mode, following two ion transitions per compound. It yielded a limit of quantification of 2 microg/L for the six compounds and intra-assay coefficients of variation (CV%) lower than 20%. This method was applied to the analysis of urines samples from a small cohort of non-exposed volunteers. At least one of the six DAP was detected in each sample. This result confirmed the feasibility of a LC-MS/MS procedure for monitoring the general population exposure to some frequently employed organophosphate pesticides.  相似文献   

5.
Ion-exchange chromatography (IEC) is the most widely used method for amino acid analysis in physiological fluids because it provides excellent separation and reproducibility, with minimal sample preparation. The disadvantage, however, is the long analysis time needed to chromatographically resolve all the amino acids. To overcome this limitation, we evaluated a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method, which utilizes aTRAQ reagents, for amino acid analysis in urine. aTRAQ reagents tag the primary and secondary amino groups of amino acids. Internal standards for each amino acid are also labeled with a modified aTRAQ tag and are used for quantification. Separation and identification of the amino acids is achieved by liquid chromatography tandem mass spectrometry using retention times and mass transitions, unique to each amino acid, as identifiers. The run time, injection-to-injection, is 25 min, with all amino acids eluting within the first 12 min. This method has a limit of quantification (LOQ) of 1 μmol/L, and is linear up to 1000 μmol/L for most amino acids. The Coefficient of Variation (CV) was less than 20% for all amino acids throughout the linear range. Method comparison demonstrated concordance between IEC and LC-MS/MS and clinical performance was assessed by analysis of samples from patients with known conditions affecting urinary amino acid excretion. Reference intervals established for this method were also concordant with reference intervals obtained with IEC. Overall, aTRAQ reagents used in conjunction with LC-MS/MS should be considered a comparable alternative to IEC. The most attractive features of this methodology are the decreased run time and increased specificity.  相似文献   

6.
Despite the new advances in bioanalytical techniques, the analysis of low-molecular-weight organic acids in complex matrices is still a challenge. Although new strategies applying liquid chromatography-tandem mass spectrometry (LC-MS/MS) seem to be promising, sample preparation methodologies hamper its application in most clinical laboratories. The quantitation of methylmalonic acid (MMA) in biological matrices is an emblematic example due to its low concentration, the need for derivatization to increase its molecular weight, and the presence of the physiologically more abundant isomer succinic acid. Here we present a new strategy for rapid and sensitive MMA quantitation by combining alkylative extraction and LC-MS/MS. Alkylative extraction conditions were optimized to allow endogenous detection of MMA using only 50 μL of serum with a short sample preparation procedure. The formation of a unique ion from the MMA dipentafluorobenzyl derivative in negative atmospheric pressure chemical ionization (APCI) allowed its detection with high sensitivity and with no interference from succinic acid, a more abundant physiologically present isomer.  相似文献   

7.
Fatty acid ethanolamides (FAE) represent a group of lipid signaling molecules associated with many physiological and pharmacological actions; however, low FAE tissue levels pose challenges in terms of analytical characterization. The objective was to develop a competent ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for analysis of multiple FAE in animal and human tissue samples. Analytes were extracted using lipid-phase and solid-phase extraction procedures. Chromatographic separation was achieved using a gradient elution in 8 min. FAE were quantified by MS/MS in positive electrospray ionization mode. Linearity was shown in lower and higher FAE concentration ranges, with a limit of quantification (LOQ) ≤0.2 ng/ml for FAE including alpha-linolenoylethanolamide (ALEA), arachidonoylethanolamide (AEA), docosahexaenoylethanolamide (DHEA), linoleoylethanolamide (LEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA). Accuracy was shown to be between 92.4% and 108.8%, and precision was <10% for all FAE species. In sum, this sensitive and reproducible method can be used to simultaneously determine multiple FAE at low concentrations in order to facilitate further study of the role of FAE on physiological state.  相似文献   

8.
Plasma vitamin K1 (phylloquinone) determination is commonly used for the diagnosis of vitamin K deficiency in patients suffering from lipid malabsorption. Moreover, current evidence that adequate vitamin K intake, and correspondingly adequate plasma vitamin K1 concentration, could also be of importance in relation to bone and brain diseases emphasizes the need to improve the current analytical methods. We developed a liquid chromatography coupled to tandem mass spectrometry method using a stable isotope ring-D4-labeled internal standard of vitamin K1 and operating in the multiple reaction monitoring mode by the selection of a precursor and product ions. The atmospheric pressure chemical ionization (APCI) method was shown to be more sensitive than electrospray ionization. After a single-step extraction with cyclohexane, chromatographic separation was performed on a C18 column with an isocratic mobile phase. The linearity was up to 5400 ng/L, and the limit of detection was 14 ng/L. Intra- and interrun precision were 2.4% and 8.3%, respectively, for the lower limit of the reference range. Recovery was better than 98%. The method is simple and reliable, allowing accurate vitamin K1 measurement in plasma samples from healthy subjects and patients suffering from vitamin K deficiency.  相似文献   

9.
With the growing interest for peptides and proteins in different kinds of fields, e.g. pharmacy, clinical diagnostics or food industry, the quantification of these compounds is becoming more and more important. Quantitative analysis of these analytes in biological matrices, however, remains a challenging task, due to the complexity of both the matrix and the analytical characteristics of these large bio-molecules. Liquid chromatography coupled to (tandem) mass spectrometry (LC-MS or LC-MS/MS) is the preferred analytical technique for peptide analysis as it allows very selective and sensitive measurements. This article summarizes the numerous published LC-MS applications for the quantification of peptides in biological matrices and discusses all different issues herewith concerned. This includes chromatographic aspects as the selection and effects of mobile and stationary phase, flow rate and temperature, as well as mass spectrometric characteristics such as ionization and detection modes, collision-induced dissociation of peptides and factors influencing the mass spectrometric response. For both techniques the main properties of all described methods have been listed, creating a comprehensive overview with the peptide analytes divided into different classes. Likewise, all other issues concerned with quantitative bioanalysis have been evaluated in detail, including extensive consideration of several different applied sample pre-treatment techniques and reflection of subjects as the choice for an internal standard and assay validation. Furthermore, several issues which are of particular interest for the quantitative bioanalysis of peptide compounds like peptide adsorption and degradation have been regarded.  相似文献   

10.
A sensitive, reproducible, and rapid analytical method for the analysis of trace-level heterocyclic amines (HCAs) that are expected to have high levels of human exposure was developed. Liquid–liquid extraction (LLE) with dichloromethane (DCM) followed by solid-phase extraction (SPE) was carried out. Liquid extraction with DCM under basic conditions was efficient in extracting HCAs from urine samples. For further purification, mixed mode cationic exchange (MCX) cartridges were applied to eliminate the remaining interferences after liquid extraction. Separation and quantification were performed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) in selected reaction monitoring (SRM) mode. The overall recoveries ranged between 71.0% and 113.6% with relative standard deviations (RSDs) of 5.1% to 14.7% for the entire procedure. The limits of detection (LODs) and limits of quantification (LOQs) of the proposed analytical method were in the ranges of 0.04 to 0.10 ng/ml and 0.15 to 0.36 ng/ml, respectively. This method was applied to the analysis of monitoring in urine samples for Korean school children, and the results demonstrated that the method can be used for the trace determination of HCAs in urine samples.  相似文献   

11.
A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-fluorouracil in monkey serum. A liquid/liquid extraction with ethyl acetate (90%) and isopropyl alcohol (10%) was used to extract simultaneously doxifluridine and 5-FU which have considerable difference in the polarity. Optimum chromatographic separation was achieved on a Agilent Zorbax C(18) (100 mm x 2.1mm, 3.5 microm) column with a mobile phase of methanol-water (20:80, v/v). The flow rate was 0.2 mL/min with total cycle time of 5 min. The lower limit of quantification (LLOQ) was validated at 10.0 ng/mL of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both compounds met FDA Guidance criteria of +/-15% with average QC accuracy of 95.5-105.0% and coefficients of variation of 1.1-9.5% in the 10-2000 ng/mL concentration range. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability to support the analysis of monkey serum samples.  相似文献   

12.
A sensitive method for the separation and determination of amlodipine enantiomers in plasma has been developed based on solid-phase extraction (SPE) with disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE technique is used to isolate the drug from the biological matrix and to prepare a cleaner sample before injection and analysis by HPLC coupled to mass spectrometry. The DEC is filled with ethyl silica (50 mg) and is first conditioned with a 2.5% ammonia in methanol solution and then with ammonium acetate buffer. A 1.0-ml volume of plasma is then applied on the DEC. The washing step is first performed with ammonium acetate buffer and secondly with a mixture of water and methanol (65:35, v/v), while the final elution step is obtained by dispensing methanol containing 2.5% of ammonia. The eluate is then collected and evaporated to dryness before being dissolved in the LC mobile phase and injected into the LC system. The stereoselective analysis of amlodipine is achieved on a Chiral AGP column containing alpha(1)-acid glycoprotein as chiral selector by using a mobile phase consisting of a 10-mM acetate buffer (pH 4.5) and 1-propanol (99:1, v/v). The LC system is coupled to tandem mass spectrometry with an APCI interface in the positive-ion mode. The chromatographed analytes are detected in the selected reaction monitoring mode (SRM). The MS/MS ion transitions monitored are 409 to 238 for amlodipine, and 260 to 116 for S-(-)-propranolol used as internal standard (IS). The method was validated considering different parameters, such as linearity, precision and accuracy. The limit of quantitation was found to be 0.1 ng/ml for each amlodipine enantiomer.  相似文献   

13.
A simple liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method with highly improved sensitivities for the determination of helicid in rat bile, urine, feces and most tissues was developed. The tissues and feces were firstly homogenized mechanically using deionized water as the media. Bile, urine, tissues and feces homogenates were extracted by liquid–liquid extraction with n-butyl alcohol for sample preparation. The subsequent analysis procedures were performed on a Shimadzu LCMS2010A system (electrospray ionization single quadrupole mass analyzer). A Luna C18 column (150 mm × 2.00 mm, 5 μm) was used as the analytical column, while a mixture of acetonitrile and ammonium chloride water solution was used as the mobile phase. The proportions of mobile phase were changed timely according to gradient programs. Chlorinated adducts of molecular ions [M+Cl]? at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard), respectively. The method was validated to be accurate, precise and rugged with good linearity. The proposed method was successfully applied to the preclinical tissue distribution and excretion studies of helicid in rats.  相似文献   

14.
An assay to quantify several possible breast cancer peptide biomarkers in human serum has been developed and validated, using liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). The peptides include bradykinin, Hyp3-bradykinin, des-Arg9-bradykinin and fragments of fibrinogen α-chain (Fib-α[605–629]), inter-α-trypsin inhibitor heavy chain 4 (ITIH4[666–687]) and complement component 4a (C4a[1337–1350]). Ile13-ITIH4[666–687], d20-C4a[1337–1350] and Sar-D-Phe8-des-Arg9-bradykinin were used as internal standards. Bovine plasma, with 2 mM captopril and 2 mM d-l-mercaptoethanol-3-guanidino-ethylthiopropanoic acid (MEGETPA) to prevent rapid degradation of the bradykinins, was used as analyte-free matrix. Recoveries for solid-phase extraction (SPE) on mixed-mode weak cation exchange sorbents were between 62 and 90%. Multiple reaction monitoring (MRM) on a triple quadrupole mass spectrometer equipped with a heated electrospray source (H-ESI), operating in the positive ion-mode, was used for detection. The assay was fully validated and stabilities of the peptides were extensively explored. Bradykinin (10–500 ng/ml), Hyp3-bradykinin (4–200 ng/ml), des-Arg9-bradykinin (2–100 ng/ml), Fib-α[605–629] (120–3000 ng/ml), ITIH4[666–687] (0.4–10 ng/ml) and C4a[1337–1350] (1–25 ng/ml) were simultaneously quantified with deviations from the nominal concentrations below 22% and intra- and inter-assay precisions below 15 and 20%, respectively, for all peptides at all concentrations. The method has been successfully applied to several serum samples from breast cancer patients and matched controls.  相似文献   

15.
Preclinical efficacy testing commonly involves studies that require considerable resources and time. One valuable tool in this endeavor is the characterization of relevant biomarkers. A method has been developed for the simultaneous determination of collagen biomarker candidates as an instrument in screening compounds for efficacy. Two potential candidates, the 3-hydroxypyridinium crosslinks pyridinoline and deoxypyridinoline, were selected for analysis in collagen degradation models. Tissue or urine samples were collected, prepared, and quantitated for the biomarkers using spiked calibration curves and liquid chromatography tandem mass spectrometry. The development of a quick and simple assay method would allow us to increase the chances for success in efficacy screening by eliminating compounds with poor biomarker profiles. The method proposed here appears to be more selective, convenient, precise (generally <10% RSD), accurate (generally <10% RE), and sensitive relative to previously established methodology.  相似文献   

16.
The tissue distribution of folate in its numerous coenzyme forms may influence the development of disease at different sites. For instance, the susceptibility of human colonic mucosa to localized folate deficiency may predispose to the development of colorectal cancer. We report a sensitive and robust ultra high-performance liquid chromatography (UHPLC) tandem mass spectrometry method for quantifying tissue H4folate, 5-CH3-H4folate, 5-CHO-H4folate, folic acid, and 5,10-CH+-H4folate concentration. Human colonic mucosa (20–100 mg) was extracted using lipase and conjugase enzyme digestion. Rapid separation of analytes was achieved on a UHPLC 1.9-μm C18 column over 7 min. Accurate quantitation was performed using stable isotopically labeled (13C5) internal standards. The instrument response was linear over physiological concentrations of tissue folate (R2 > 0.99). Limits of detection and quantitation were less than 20 and 30 fmol on column, respectively, and within- and between-run imprecision values were 6–16%. In colonic mucosal samples from 73 individuals, the average molar distribution of folate coenzymes was 58% 5-CH3-H4folate, 20% H4folate, 18% formyl-H4folate (sum of 5-CHO-H4folate and 5,10-CH+-H4folate), and 4% folic acid. This assay would be useful in characterizing folate distribution in human and animal tissues as well as the role of deregulated folate homeostasis on disease pathogenesis.  相似文献   

17.
The potential importance of the methylation cycle during embryonic development necessitates the establishment of methodology to detect alterations in the relative abundance of s-adenosylmethionine (SAM) and s-adenosylhomocysteine (SAH) in an embryonic experimental system. We have developed a precise and sensitive method for measurement of SAM and SAH based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in single neurulation-stage mouse embryos. Use of a penta-fluorinated high-performance liquid chromatography (HPLC) stationary phase gave enhanced sensitivity due to optimal ionisation in organic mobile phase and increased retention time compared to standard reversed-phase separation. Calibration curves suitable for the analysis of neurulation-stage mouse embryos (SAM 0.02-25.0microM, SAH 0.01-10.0microM) were linear (r(2)>0.997) with limits of detection for SAM and SAH of 10 and 2.5nmol/L, respectively.  相似文献   

18.
The six phenolic constituents are water-soluble components extracted from the Chinese medical herb danshen, the dried roots of Salvia miltiorrhiza Bunge (Labiatae). An liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based method has been developed for the simultaneous quantification of six phenolic constituents of danshen (magnesium lithospermate B (MLB), rosmarinic acid (RA) and lithospermic acid (LA), caffeic acid (CAA), protocatechuic aldehyde (3,4-dihydroxybenzaldehyde, Pal), 3,4-dihydroxyphenyllactic acid (danshensu)) in human serum with chloramphenicol as internal standard. The serum samples were treated by special liquid-liquid extraction, and the analytes were determined using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode, with sufficient sensitivity to allow analysis of human serum samples generated following administration of a clinically relevant dose. Good linearity over the range 8-2048 ng/mL for six phenolic constituents was observed. The intra- and inter-day precisions (CV) of analysis were <13%, and the accuracy ranged from 88 to 116%. This quantitation method was successfully applied to a pharmacokinetic study of i.v. drip infusion of Danshen injection fluid in human.  相似文献   

19.
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号