首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Abdominal muscle use during breathing in unanesthetized dogs   总被引:2,自引:0,他引:2  
The pattern of abdominal muscle use during breathing in unanesthetized dogs is unknown. Therefore, we have recorded the electromyograms of the rectus abdominis, external oblique, and transversus abdominis in eight conscious animals breathing quietly in the sitting, standing, and prone postures. During quiet breathing in the sitting posture, all animals invariably had a large amount of phasic expiratory activity in the transversus abdominis. In contrast, only four animals showed some expiratory activity in the external oblique, and only one animal had expiratory activity in the rectus abdominis. A similar pattern was observed when the animals were standing or lying prone, although the amount of expiratory activity was less in this posture. Bilateral cervical vagotomy in four animals did not affect the degree of transversus abdominis expiratory activation or the influence of posture. We conclude that in conscious dogs 1) the abdominal muscles play an important role during breathing and make spontaneous quiet expiration a very active process, 2) the transversus abdominis is the primary respiratory muscle of the abdomen, and 3) unlike in anesthetized animals, extrapulmonary receptors play a major role in promoting abdominal expiratory contraction.  相似文献   

3.
4.
5.
During an antiorthostatic posture change, left atrial (LA) diameter and arterial pulse pressure (PP) increase, and plasma arginine vasopressin (AVP) is suppressed. By comparing the effects of a 15-min posture change from seated to supine with those of 15-min seated negative pressure breathing in eight healthy males, we tested the hypothesis that with similar increases in LA diameter, suppression of AVP release is dependent on the degree of increase in PP. LA diameter increased similarly during the posture change and negative pressure breathing (-9 to -24 mmHg) from between 30 and 31 +/- 1 to 34 +/- 1 mm (P < 0.05). The increase in PP from 38 +/- 2 to 44 +/- 2 mmHg (P < 0.05) was sustained during the posture change but only increased during the initial 5 min of negative pressure breathing from 36 +/- 3 to 42 +/- 3 mmHg (P < 0.05). Aortic transmural pressure decreased during the posture change and increased during negative pressure breathing. Plasma AVP was suppressed to a lower value during the posture change (from 1.5 +/- 0.3 to 1.2 +/- 0.2 pg/ml, P < 0.05) than during negative pressure breathing (from 1.5 +/- 0.3 to 1.4 +/- 0.3 pg/ml). Plasma norepinephrine was decreased similarly during the posture change and negative pressure breathing compared with seated control. In conclusion, the results are in compliance with the hypothesis that during maneuvers with similar cardiac distension, suppression of AVP release is dependent on the increase in PP and, furthermore, probably unaffected by static aortic baroreceptor stimulation.  相似文献   

6.
7.
8.
Pressure-area behavior of the excised trachea is well documented, but little is known of tracheal compliance in vivo. Extratracheal tissue pressures are not directly measurable, but transmural pressure for the intrathoracic trachea is inferred from intra-airway and pleural pressure differences. Extramural pressure of the cervical trachea is assumed to be atmospheric. The difference in transmural pressure between the intra- and extrathoracic tracheal segments should be exaggerated during Mueller and Valsalva maneuvers. We used the acoustic reflection technique to measure tracheal areas above and below the thoracic inlet during these isovolume-pressure maneuvers. We found that 10 cmH2O positive pressure increased tracheal area in the extrathoracic segment by 34 +/- 16% (mean +/- SD) and in the intrathoracic segment by 35 +/- 15%. There was a reduction in area of 27 +/- 16 and 24 +/- 14%, respectively, for the extra- and intrathoracic segments with 10 cmH2O negative pressure. We conclude that the effective transmural pressure gradients do not vary significantly between intra- and extrathoracic tracheal segments.  相似文献   

9.
10.
Although there is electromyographic evidence for abdominal muscle activity during quiet breathing in standing subjects, several studies have shown, or assumed, that subjects normally breathe on their relaxation characteristics. This latter observation would by itself suggest that abdominal muscles do not contract during quiet breathing. To test this assumption we observed abdominal and rib cage displacements with magnetometers in 17 uninformed subjects. During quiet breathing most subjects showed evidence of tonic or phasic abdominal muscle contraction while standing and sitting but not supine. Subjects studied during hyperpnea immediately following exercise-showed evidence of greater abdominal muscle contraction than at rest. We conclude that most subjects standing at rest normally contract their abdominal muscles.  相似文献   

11.
Changes of respiratory input impedance during breathing in humans.   总被引:4,自引:0,他引:4  
Changes of total respiratory resistance (Rrs) and reactance (Xrs) were studied between 8 and 32 Hz at five moments during the respiratory cycle in healthy adults (group A) and children (group B) and in patients with chronic obstructive lung disease (group C) and with upper airway obstruction (group D). Two forced oscillation techniques were used: the conventional one and the head generator, with the oscillations applied at the mouth and around the head of the subject, respectively. Both techniques yielded similar results. Rrs is lowest during the transition from inspiration to expiration and highest in the course of expiration, except in group D. Mean Xrs is highest at the transitions from inspiration to expiration or vice versa and lowest during expiration, except in group D. In groups C and D, the increases of Rrs are accompanied by a more pronounced negative frequency dependence of Rrs. The variations of Rrs and Xrs appear to be markedly flow dependent and may be a consequence of the interaction of breathing with oscillatory flows.  相似文献   

12.
13.
14.
Rib cage mechanics during quiet breathing and exercise in humans   总被引:4,自引:0,他引:4  
Kenyon, C. M., S. J. Cala, S. Yan, A. Aliverti, G. Scano, R. Duranti, A. Pedotti, and Peter T. Macklem. Rib cage mechanics during quiet breathing and exercise in humans. J. Appl. Physiol. 83(4): 1242-1255, 1997.Duringexercise, large pleural, abdominal, and transdiaphragmatic pressureswings might produce substantial rib cage (RC) distortions. We used athree-compartment chest wall model (J. Appl.Physiol. 72: 1338-1347, 1992) to measuredistortions of lung- and diaphragm-apposed RC compartments (RCp andRCa) along with pleural and abdominal pressures in five normal men. RCpand RCa volumes were calculated from three-dimensional locations of 86 markers on the chest wall, and the undistorted (relaxation) RCconfiguration was measured. Compliances of RCp and RCa measured duringphrenic stimulation against a closed airway were 20 and 0%,respectively, of their values during relaxation. There was marked RCdistortion. Thus nonuniform distribution of pressures distorts the RCand markedly stiffens it. However, during steady-state ergometerexercise at 0, 30, 50, and 70% of maximum workload, RC distortionswere small because of a coordinated action of respiratory muscles, sothat net pressures acting on RCp and RCa were nearly the samethroughout the respiratory cycle. This maximizes RC compliance andminimizes the work of RC displacement. During quiet breathing, plots ofRCa volume vs. abdominal pressure were to the right of the relaxationcurve, indicating an expiratory action on RCa. We attribute this topassive stretching of abdominal muscles, which more thancounterbalances the insertional component of transdiaphragmatic pressure.

  相似文献   

15.
16.
17.
18.
Previous fiber-optic studies in humans have demonstrated narrowing of the glottic aperture in expiration during application of expiratory resistive loads. Nine healthy subjects were studied to determine the effect of expiratory resistive loads on the electromyographic activity of the thyroarytenoid (TA) muscle, a vocal cord adductor. Four of the nine subjects also underwent the application of inspiratory resistive loads and voluntary prolongation of either inspiratory (TI) or expiratory (TE) time. TA activity was recorded by intramuscular hooked-wire electrodes. During quiet breathing in all subjects, the TA was phasically active on expiration and often tonically active throughout the respiratory cycle. TA expiratory activity progressively increased with increasing levels of expiratory load. Inspiratory loads resulted in increased TA "inspiratory" activity. Voluntary prolongation of TE to times similar to those reached during loaded breathing induced increases in TA expiratory activity similar to those reached during the loaded state. Voluntary prolongation of TI was associated with an increase in TA inspiratory activity. Similar increases in TI during inspiratory loading or voluntary conditions were associated with comparable increases in TA inspiratory activity in three of the four subjects. In conclusion, increased activation of TA during the application of expiratory resistive loads implies that the reported narrowing of glottic aperture during expiratory loading is an active phenomenon. Changes in activation of the TA with resistive loads appear to be related to changes in respiratory pattern.  相似文献   

19.
Heart rate varies with breathing patterns, especially in sleep apnea. To assess the effects on heart rate of recurrent apneas interrupting tidal breathing, we studied five normal awake male subjects. These subjects voluntarily changed their breathing pattern from regular tidal breathing to tidal breathing interrupted by breath holding at end expiration. This recurrent apneic breathing pattern did not change mean heart rate but increased its variance significantly. In addition, the variations in heart rate formed a cyclic pattern of oscillation with a mean cycle length identical to both arterial O2 saturation (SaO2) (R = 0.95; P less than 0.01) and ventilation (R = 0.92; P less than 0.01). Cyclic changes in either SaO2 or ventilation reproduced the oscillatory patterns of heart rate seen with tidal breathing interrupted by multiple apneas, but the amplitude of the variance in heart rate was smaller. Finally, preventing the cyclic declines in SaO2 with supplemental O2 did not significantly alter the heart rate changes seen in tidal breathing interrupted by apneas.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号