首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Staining of esterase-active bacteria with carboxyfluorescein diacetate (CFDA) has been used to evaluate the viability of various types of cell. However, the outer membrane of Gram-negative bacteria prevents CFDA from permeating into the cell. Although EDTA can increase the permeability of the outer membrane allowing CFDA to enter the cells, it was experimentally confirmed that there is still considerable difficulty in visualizing viable cells due to passive diffusion of carboxyfluorescein (CF), a hydrolyzed product of CFDA, out of the cells. We found that glutaraldehyde enhances the discriminative recognition of esterase-active Gram-negative bacteria under microscopic observation by improving the efficacy of staining. We believe the successful staining in the presence of glutaraldehyde is due to two separate effects: an increase in the permeability of CFDA into the cell and prevention of leakage of CF out of the cell.  相似文献   

2.
Most techniques for assessing cell division can either detect limited numbers of cell divisions (bromodeoxyuridine incorporation) or only quantify overall proliferation (tritiated thymidine incorporation). In the majority of cases, viable cells of known division history cannot subsequently be obtained for functional studies. The cells of the immune system undergo marked proliferation and differentiation during the course of an immune response. The relative lack of an organized structure of the lymphohaemopoietic system, in contrast with other organ systems, makes lineage interrelationships difficult to study. Coupled with the remarkable degree of mobility engendered by recirculation, the differentiation occurring along with cell division in the immune system has not been readily accessible for investigation. The present article reviews the development of a cell division analysis procedure based on the quantitative serial halving of the membrane permeant, stably incorporating fluorescent dye carboxyfluorescein diacetate succinimidyl ester (CFSE or CFDA, SE). The technique can be used both in vitro and in vivo, allowing eight to 10 successive divisions to be resolved by flow cytometry. Furthermore, viable cells from defined generation numbers can be sorted by flow cytometry for functional analysis.  相似文献   

3.
Protein glycation is a ubiquitous process involved in vascular complications observed in diabetes. Glyoxal (GO), an intracellular reactive oxoaldehyde that is one of the most potent glycation agents, readily reacts with amines present on proteins to produce the lysine-derived adduct carboxymethyllysine, which is a prevalent advanced glycation end-product (AGE). Our group previously showed that cell exposure to GO leads to an alteration in the cell contractile activity that could occur as a result of the glycation of various proteins regulating the cell contractile machinery. Here, we measured the extent of glycation on three functionally distinct proteins known to participate in cell contraction and cytoskeletal organization—Rho-kinase (ROCK), actin, and gelsolin (GSN)—using an assay based on the reaction of the cell membrane-permeable fluorescent probe carboxyfluorescein diacetate succinimidyl ester (CFDA–SE), which reacts with primary amine groups of proteins. By combining CFDA–SE fluorescence and Western blot detection, we observed (following GO incubation) increased glycation of actin and ROCK as well as an increased interaction between actin and GSN as observed by co-immunoprecipitation. Thus, we conclude that the use of the fluorescent probe CFDA–SE offers an interesting alternative to perform a comparative analysis of the extent of intracellular protein glycation in live cells.  相似文献   

4.
Bergsdorf C  Beyer C  Umansky V  Werr M  Sapp M 《FEBS letters》2003,536(1-3):120-124
Human papillomavirus virus-like particles (VLPs) have recently been used to deliver genes into mammalian cells in vitro and in vivo. Here, we investigated whether VLPs may serve as an efficient carrier of low molecular weight compounds (e.g. hormones, vitamins, peptides etc.) into cells. COS7 cells were incubated with recombinant HPV-16L1/L2 VLPs labelled with the fluorescence dye carboxyfluorescein diacetate succinimidyl ester. Using flow cytometry, we demonstrate that labelled VLPs can specifically bind to the cell surface followed by their complete internalisation. Our results indicate that VLPs are promising vehicles for highly efficient delivery of low molecular weight compounds into cells.  相似文献   

5.
Previous bacterial transport studies have utilized fluorophores which have been shown to adversely affect the physiology of stained cells. This research was undertaken to identify alternative fluorescent stains that do not adversely affect the transport or viability of bacteria. Initial work was performed with a groundwater isolate, Comamonas sp. strain DA001. Potential compounds were first screened to determine staining efficiencies and adverse side effects. 5-(And 6-)-carboxyfluorescein diacetate, succinimidyl ester (CFDA/SE) efficiently stained DA001 without causing undesirable effects on cell adhesion or viability. Members of many other gram-negative and gram-positive bacterial genera were also effectively stained with CFDA/SE. More than 95% of CFDA/SE-stained Comamonas sp. strain DA001 cells incubated in artificial groundwater (under no-growth conditions) remained fluorescent for at least 28 days as determined by epifluorescent microscopy and flow cytometry. No differences in the survival and culturability of CFDA/SE-stained and unstained DA001 cells in groundwater or saturated sediment microcosms were detected. The bright, yellow-green cells were readily distinguished from autofluorescing sediment particles by epifluorescence microscopy. A high throughput method using microplate spectrofluorometry was developed, which had a detection limit of mid-105 CFDA-stained cells/ml; the detection limit for flow cytometry was on the order of 1,000 cells/ml. The results of laboratory-scale bacterial transport experiments performed with intact sediment cores and nondividing DA001 cells revealed good agreement between the aqueous cell concentrations determined by the microplate assay and those determined by other enumeration methods. This research indicates that CFDA/SE is very efficient for labeling cells for bacterial transport experiments and that it may be useful for other microbial ecology research as well.  相似文献   

6.
The cytoplasmic dye carboxyfluorescein diacetate succinimidyl ester (CFSE) is used to quantify cell kinetics. It is particularly important in studies of lymphocyte homeostasis where its labelling of cells irrespective of their stage in the cell cycle makes it preferable to deuterated glucose and BrdU, which only label dividing cells and thus produce unrepresentative results. In the past, experiments have been limited by the need to obtain a clear separation of CFSE peaks forcing scientists to adopt a strategy of in vitro labelling of cells followed by their injection into the host. Here we develop a framework for analysis of in vivo CFSE labelling data. This enables us to estimate the rate of proliferation and death of lymphocytes in situ, and thus represents a considerable advance over current procedures. We illustrate this approach using in vivo CFSE labelling of B lymphocytes in sheep.  相似文献   

7.
This protocol outlines the carboxyfluorescein diacetate succinimidyl ester (CFSE) method for following the proliferation of human lymphocytes in vitro and mouse lymphocytes both in vitro and in vivo. The method relies on the ability of CFSE to covalently label long-lived intracellular molecules with the highly fluorescent dye, carboxyfluorescein. Following each cell division, the equal distribution of these fluorescent molecules to progeny cells results in a halving of the fluorescence of daughter cells. The CFSE labeling protocol described, which typically takes <1 h to perform, allows the detection of up to eight cell divisions before CFSE fluorescence is decreased to the background fluorescence of unlabeled cells. Protocols are outlined for labeling large and small numbers of human and mouse lymphocytes, labeling conditions being identified that minimize CFSE toxicity but maximize the number of cell divisions detected. An important feature of the technique is that division-dependent changes in the expression of cell-surface markers and intracellular proteins are easily quantified by flow cytometry.  相似文献   

8.
Intravital fluorescence microscopy (IVM) is a predestined tool for investigating the fate of leukocytes during the process of leukocyte recruitment. In the present study, the commonly used dye for this purpose, rhodamine 6G, and carboxyfluorescein diacetate succinimidyl ester (CFDA‐SE) were compared for leukocytes labelling with respect to suitability for IVM studies. Their potential in labelling different leukocytes subpopulations as well as their fluorescence intensities were assessed by flow cytometry revealing distinct differences between both dyes. These differences had a profound impact on their application for in vivo imaging of leukocyte‐endothelium interactions. In summary, CFDA‐SE revealed superior in labelling leukocytes for in vivo microscopy with respect to image quality. In addition, we could show the efficiency of CFDA‐SE also under disease condition in an animal model of sepsis. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

9.
Bartonella infection (Bartonella henselae in particular) is responsible for a widening spectrum of human diseases. The persistent colonization of erythrocytes is a feature of Bartonella infection. Endothelial and epithelial cells are also widely used to study the pathogenesis of bartonellosis in vitro. Exploring a convenient method for visualizing the bacillus without affecting infectivity would be very interesting. Carboxyfluorescein diacetate succinimidyl ester (CFSE) has been previously used for staining several bacterial species to study their adhesion to host cells. The present study demonstrated the efficiency and safety of using CFSE in staining B. henselae. The staining of bacillus-invaded erythrocytes and epithelial cells in vitro successfully allowed for flow cytometry and confocol microscopy analyses. Parallel tests using untreated bacteria confirmed that CFSE staining did not result in side effects on the infectivity of B. henselae. Labeling Bartonella with CFSE is a valuable method for studying the bacteria-host interaction.  相似文献   

10.
Yeast cells and mould spores can be fluorescently labelled with the viability stain carboxyfluorescein diacetate (CFDA) and detected on a membrane filter by laser scanning (solid phase cytometry, SPC). Although the selectivity of an existing commercial SPC procedure for fungi is ensured by using a 2 microm pore size membrane filter and a pre-incubation on a proprietary spore swelling/activation medium, some bacteria are still co-detected. In the present study, the selectivity for fungi has been enhanced by combining the green fluorescent CFDA with a second red fluorescent label, i.e. TRITC-concanavalin A, targetting fungal but not commonly bacterial cells. Additional improvements resulted from the prolongation of the pre-incubation and from the extra-rinsing of the membrane filter. The improved method was applied to detect fungi in hospital waters, dialysis fluids and endoscopic rinse waters. In general, SPC detected more fungi in water than plate methods. The occurrence of fungi in dialysis fluid and endoscopic rinse water was rare. Evidence for the presence of fungal viable but non-culturable (VBNC) cells in water was weak.  相似文献   

11.

Background  

Phagocytosis assays are traditionally performed in vitro using polymorphonuclear leukocytes (PMNs) isolated from peripheral blood or the peritoneum and heat-killed, pre-opsonized organisms. These assays may not adequately mimic the environment within the infected lung. Our laboratory therefore has developed a flow cytometric in vivo phagocytosis assay that enables quantification of PMN phagocytosis of viable bacteria within the lungs of rats. In these studies, rats are injected transtracheally with lipopolysaccharide (LPS) to recruit PMNs to their lungs. They are then infected with live 5(-and 6) carboxyfluorescein diacetate succinimidyl ester (CFDA/SE) labeled type 3 Streptococcus pneumoniae. Bronchoalveolar lavage is performed and resident alveolar macrophages and recruited PMNs are labeled with monoclonal antibodies specific for surface epitopes on each cell type. Three color flow cytometry is utilized to identify the cell types, quantify recruitment, and determine uptake of the labeled bacteria.  相似文献   

12.
Laboratory and field-scale studies with stained cells were performed to monitor cell growth in groundwater systems. During cell division, the fluorescence intensity of the protein stain 5-(and 6-)-carboxyfluorescein diacetate succinimidyl ester (CFDA/SE) for each cell is halved, and the intensity can be tracked with a flow cytometer. Two strains of bacteria, Comamonas sp. strain DA001 and Acidovorax sp. strain OY-107, both isolated from a shallow aquifer, were utilized in this study. The change in the average generation or the average fluorescence intensity of the CFDA/SE-stained cells could be used to obtain estimates of doubling times. In microcosm experiments, the CFDA/SE-based doubling times were similar to the values calculated by total cell counting and were independent of cell concentration. Intact and repacked sediment core experiments with the same bacteria indicated that changes in groundwater chemistry were just as important as growth rates in determining planktonic cell concentrations. The growth rates within the sediment cores were similar to those calculated in microcosm experiments, and preferential transport of the daughter cells was not observed. The experiments indicated that the growth rates could be determined in systems with cell losses due to other phenomena, such as attachment to sediment or predation. Application of this growth rate estimation method to data from a field-scale bacterial transport experiment indicated that the doubling time was approximately 15 days, which is the first known direct determination of an in situ growth rate for bacteria in an aquifer.  相似文献   

13.
Mature T and B lymphocytes respond to receptor-delivered signals received during and following activation. These signals regulate the rates of cell death, growth, differentiation and migration that ultimately establish the behaviour patterns collectively referred to as immune regulation. We have been pursuing the philosophy that in vitro systems of lymphocyte stimulation, when analysed quantitatively, help reveal the logical attributes of lymphocyte behaviour. The development of carboxyfluorescein diacetate succinimidyl ester (CFSE) to track division has enabled the variable of division number to be incorporated into these quantitative analyses. Our studies with CFSE have established a fundamental link between differentiation and division number. Isotype switching, expression of T cell cytokines, surface receptor alterations and changes to intracellular signalling components all display independent patterns of change with division number. The stochastic aspects of these changes and the ability of external signals to independently regulate them argue for a probabilistic modelling framework for describing and understanding immune regulation.  相似文献   

14.
Previous bacterial transport studies have utilized fluorophores which have been shown to adversely affect the physiology of stained cells. This research was undertaken to identify alternative fluorescent stains that do not adversely affect the transport or viability of bacteria. Initial work was performed with a groundwater isolate, Comamonas sp. strain DA001. Potential compounds were first screened to determine staining efficiencies and adverse side effects. 5-(And 6-)-carboxyfluorescein diacetate, succinimidyl ester (CFDA/SE) efficiently stained DA001 without causing undesirable effects on cell adhesion or viability. Members of many other gram-negative and gram-positive bacterial genera were also effectively stained with CFDA/SE. More than 95% of CFDA/SE-stained Comamonas sp. strain DA001 cells incubated in artificial groundwater (under no-growth conditions) remained fluorescent for at least 28 days as determined by epifluorescent microscopy and flow cytometry. No differences in the survival and culturability of CFDA/SE-stained and unstained DA001 cells in groundwater or saturated sediment microcosms were detected. The bright, yellow-green cells were readily distinguished from autofluorescing sediment particles by epifluorescence microscopy. A high throughput method using microplate spectrofluorometry was developed, which had a detection limit of mid-10(5) CFDA-stained cells/ml; the detection limit for flow cytometry was on the order of 1,000 cells/ml. The results of laboratory-scale bacterial transport experiments performed with intact sediment cores and nondividing DA001 cells revealed good agreement between the aqueous cell concentrations determined by the microplate assay and those determined by other enumeration methods. This research indicates that CFDA/SE is very efficient for labeling cells for bacterial transport experiments and that it may be useful for other microbial ecology research as well.  相似文献   

15.
Our objective was to study the properties of the carboxyfluorescein diacetate succinimidyl ester (CFDA-SE) and the methodology of cell labeling using CFDA-SE fluorescent dye. First, we analyzed the kinetics of CFDA-SE fluorescent dye intensity over time. Second, we determined the optimal concentration of CFDA-SE fluorescent dye for cell labeling. Third, we tested the toxicity of CFDA-SE fluorescent dye on labeled cells. Finally, we determined the optimal staining time of CFDA-SE fluorescent dye for cell labeling.The results show that the optimal concentration of CFDA-SE fluorescent dye for cell labeling varies according to different cell types. CFDA-SE fluorescent dye is non-toxic to cells as the cell death rate caused by CFDASE labeling is below 5%. The optimal cell labeling time was determined to be 8 min of incubation with CFDA-SE fluorescent dye. We concluded that the advantages of using CFDA-SE fluorescent dye for cell labeling are as follows: (1) the binding of CFDA-SE fluorescent dye to cells is stable; (2) CFDA-SE fluorescent dye is not toxic and does not modify the viability of labeled cells; and (3) CFDA-SE fluorescent dye is a suitable fluorochrome for cell labeling.  相似文献   

16.
The use of fluorogenic esters to detect viable bacteria by flow cytometry   总被引:7,自引:4,他引:3  
The ability of flow cytometry (FCM) to detect viable bacteria after staining with a range of fluorogenic esters was investigated with several bacterial species. The dyes studied were the fluorescein diacetate (FDA) derivatives carboxyfluorescein diacetate, 2',7'-bis-(2-carboxyethyl)-5(6)-carboxyfluorescein acetoxymethyl ester and calcein acetoxymethyl ester, as well as ChemChrome B, a commercially-available stain for the detection of viable bacteria in suspension. No one dye was found to be universal but ChemChrome B dye stained the widest number of Gram-positive and Gram-negative species, whereas the FDA derivatives preferentially stained Gram-positive bacteria. The use of ChemChrome B to detect viable bacteria in environmental samples was investigated further by studying the survival of Klebsiella pneumoniae in lakewater. During survival studies, a higher number of viable bacteria were detected both by direct viable counts and FCM after staining with rhodamine 123 and ChemChrome B than by colony-forming units, suggesting the presence of viable but nonculturable cells. These results demonstrate the potential use of FCM to enumerate viable bacteria in natural waters.  相似文献   

17.
Two differentially labeled bacterial strains were monitored in near-real time during two field-scale bacterial transport experiments in a shallow aquifer in July 2000 and July 2001. Comamonas sp. strain DA001 and Acidovorax sp. strain OY-107 were grown and labeled with the vital fluorescent stain TAMRA/SE (5 [and -6]-carboxytetramethylrhodamine, succinimidyl ester) or CFDA/SE (5 [and -6]-carboxyfluorescein diacetate, succinimidyl ester). Fluorescently labeled cells and a conservative bromide tracer were introduced into a suboxic superficial aquifer, followed by groundwater collection from down-gradient multilevel samplers. Cells were enumerated in the field by microplate spectrofluorometry, with confirmatory analyses for selected samples done in the laboratory by epifluorescence microscopy, flow cytometry, and ferrographic capture. There was general agreement in the results from all of the vital-stain-based enumeration methods, with differences ranging from <10% up to 40% for the analysis of identical samples between different tracking methods. Field analysis by microplate spectrofluorometry was robust and efficient, allowing thousands of samples to be analyzed in quadruplicate for both of the injected strains. The near-real-time data acquisition allowed adjustments to the predetermined sampling schedule to be made. The microplate spectrofluorometry data sets for the July 2000 and July 2001 experiments allowed the transport of the injected cells to be related to the site hydrogeology and injection conditions and enabled the assessment of differences in the transport of the two strains. This near-real-time method should prove effective for a number of microbial ecology applications.  相似文献   

18.
Maintaining optimal conditions in catchments or distribution systems relies heavily on water authorities having access to rapid and accurate water quality data, including an indication of bacteriological quality. In this study, the BacLight bacterial viability kit and carboxyfluorescein diacetate (CFDA) were coupled with flow cytometry (FCM) for rapid detection of physiologically active bacteria from raw and potable waters taken from various locations around South Australia. Results were compared to the direct viable count (DVC) and quantitative DVC (qDVC), in addition to the culture-based methods of the heterotrophic plate count (HPC) and a commercial SimPlate technique. Raw and potable water analysis revealed that DVC and culture-based techniques reported significantly fewer viable bacteria compared to the number of physiologically active bacteria detected using the rapid FCM assays, where this difference appeared to be nonlinear across different samples. Inconclusive results were obtained using qDVC as a viability assay. In particular, HPC results were 2-4 log orders of magnitude below that reported by the FCM assays for raw waters. Few bacteria in potable waters examined were culturable by HPC, even though FCM assays reported between 5.56 x 10(2) and 3.94 x 10(4) active bacteria ml(-1). These differences may be attributed to the presence of nonheterotrophic bacteria, sublethal injury or the adoption of an active but nonculturable (ABNC) state.  相似文献   

19.
Inhibitory effect of 1,25dihydroxycholecalciferol (1,25D3 = calcitriol) in different cell type is well recognized but its promoting effect on vascular smooth muscle cells (SMCs) is poor established. Therefore, the aim of this study was to determine stimulatory effect of calcitriol on aortal SMCs proliferation in culture. We used the cell division analysis procedure based on the quantitative sequential halving of the stably incorporating fluorescent dye carboxyfluorescein diacetate succinimidyl ester (CFSE). This technique allowed the visualization of cycles of SMCs division by flow cytometry. Rat aortal SMCs were labeled with CFSE and cultured for up to 10 days with defined concentration of calcitriol in medium. Proliferative activity as the percentage of SMCs in different phases of the cell cycle using propidium iodide was determined. Apoptosis was assessed using Annexin-V/CFDA method. The results suggest that low concentrations of an active form of vitamin D—1,25dihydroxycholecalciferol applied in supraphysiological concentration of 10 nmol/l is a mitogenic factor for aortal SMCs. None of the applied concentrations of calcitriol caused apoptosis. The findings well support our morphological (LM) and ultrastructural (TEM and SEM) observations.  相似文献   

20.
Two differentially labeled bacterial strains were monitored in near-real time during two field-scale bacterial transport experiments in a shallow aquifer in July 2000 and July 2001. Comamonas sp. strain DA001 and Acidovorax sp. strain OY-107 were grown and labeled with the vital fluorescent stain TAMRA/SE (5 [and -6]-carboxytetramethylrhodamine, succinimidyl ester) or CFDA/SE (5 [and -6]-carboxyfluorescein diacetate, succinimidyl ester). Fluorescently labeled cells and a conservative bromide tracer were introduced into a suboxic superficial aquifer, followed by groundwater collection from down-gradient multilevel samplers. Cells were enumerated in the field by microplate spectrofluorometry, with confirmatory analyses for selected samples done in the laboratory by epifluorescence microscopy, flow cytometry, and ferrographic capture. There was general agreement in the results from all of the vital-stain-based enumeration methods, with differences ranging from <10% up to 40% for the analysis of identical samples between different tracking methods. Field analysis by microplate spectrofluorometry was robust and efficient, allowing thousands of samples to be analyzed in quadruplicate for both of the injected strains. The near-real-time data acquisition allowed adjustments to the predetermined sampling schedule to be made. The microplate spectrofluorometry data sets for the July 2000 and July 2001 experiments allowed the transport of the injected cells to be related to the site hydrogeology and injection conditions and enabled the assessment of differences in the transport of the two strains. This near-real-time method should prove effective for a number of microbial ecology applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号