首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Microbial ecology of drinking water distribution systems   总被引:5,自引:0,他引:5  
The supply of clean drinking water is a major, and relatively recent, public health milestone. Control of microbial growth in drinking water distribution systems, often achieved through the addition of disinfectants, is essential to limiting waterborne illness, particularly in immunocompromised subpopulations. Recent inquiries into the microbial ecology of distribution systems have found that pathogen resistance to chlorination is affected by microbial community diversity and interspecies relationships. Research indicates that multispecies biofilms are generally more resistant to disinfection than single-species biofilms. Other recent findings are the increased survival of the bacterial pathogen Legionella pneumophila when present inside its protozoan host Hartmannella vermiformis and the depletion of chloramine disinfectant residuals by nitrifying bacteria, leading to increased overall microbial growth. Interactions such as these are unaccounted for in current disinfection models. An understanding of the microbial ecology of distribution systems is necessary to design innovative and effective control strategies that will ensure safe and high-quality drinking water.  相似文献   

2.
The relative chlorine sensitivities of bacteria isolated from chlorinated and unchlorinated drinking water distribution systems were compared by two independent methods. One method measured the toxic effect of free chlorine on bacteria, whereas the other measured the effect of combined chlorine. Bacteria from the chlorinated system were more resistant to both the combined and free forms of chlorine than those from the unchlorinated system, suggesting that there may be selection for more chlorine-tolerant microorganisms in chlorinated waters. Bacteria retained on the surfaces of 2.0-microns Nuclepore membrane filters were significantly more resistant to free chlorine compared to the total microbial population recovered on 0.2-micron membrane filters, presumably because aggregated cells or bacteria attached to suspended particulate matter exhibit more resistance than unassociated microorganisms. In accordance with this hypothesis, scanning electron microscopy of suspended particulate matter from the water samples revealed the presence of attached bacteria. The most resistant microorganisms were able to survive a 2-min exposure to 10 mg of free chlorine per liter. These included gram-positive spore-forming bacilli, actinomycetes, and some micrococci. The most sensitive bacteria were readily killed by chlorine concentrations of 1.0 mg liter-1 or less, and included most gram-positive micrococci, Corynebacterium/Arthrobacter, Klebsiella, Pseudomonas/Alcaligenes, Flavobacterium/Moraxella, and Acinetobacter.  相似文献   

3.
Regrowth of micro-organisms in drinking water distribution systems is caused by the utilisation of biodegradable compounds which are either present in treated water or originate from materials in contact with drinking water. In the Netherlands most drinking water is distributed without disinfectant residual and regrowth is limited by achieving biostable drinking water. A combination of methods is used to assess the biostability of drinking water. These methods are: (1) determination of the concentration of easily assimilable organic carbon (AOC); and (2) assessment of the biofilm formation rate (BFR). Assimilated organic carbon concentrations in drinking water in the Netherlands range from a few μg C/l in slow sand filtrates and in ground water supplies to values of ~ 50 μg C/l in supplies using ozonation in water treatment. Biofilm formation rate values were found to range from < 1 pg ATP/cm(2)/d in supplies using anaerobic ground water as the source. Increase of heterotrophic plate counts is limited at AOC values below 10 μg C/l. At BFR values below 10 pg ATP/cm(2)/d the risk of exceeding the guideline value for aeromonads (90 percentile < 200 c.f.u./100 ml) is less than 20%. Calculations based on the decrease of the AOC concentration observed in distributions systems confirm that very low concentrations of AOC can cause considerable biofilm formation on the pipe wall. The methods for assessing the biostability of drinking water combine with the assessment of the Biofilm Formation Potential of materials in contact with drinking water, thus providing a framework, the Unified Biofilm Approach, for evaluating the biostability of drinking water and materials.  相似文献   

4.
Drinking water distribution systems were analyzed for viable counts of mycobacteria by sampling water from waterworks and in different parts of the systems. In addition, loose deposits collected during mechanical cleaning of the main pipelines were similarly analyzed. The study covered 16 systems at eight localities in Finland. In an experimental study, mycobacterial colonization of biofilms on polyvinyl chloride tubes in a system was studied. The isolation frequency of mycobacteria increased from 35% at the waterworks to 80% in the system, and the number of mycobacteria in the positive samples increased from 15 to 140 CFU/liter, respectively. Mycobacteria were isolated from all 11 deposits with an accumulation time of tens of years and from all 4 deposits which had accumulated during a 1-year follow-up time. The numbers of mycobacteria were high in both old and young deposits (medians, 1.8 x 10(5) and 3.9 x 10(5) CFU/g [dry weight], respectively). Both water and deposit samples yielded the highest numbers of mycobacteria in the systems using surface water and applying ozonation as an intermediate treatment or posttreatment. The number and growth of mycobacteria in system waters correlated strongly with the concentration of assimilable organic carbon in the water leaving the waterworks. The densities of mycobacteria in the developing biofilms were highest at the distal sites of the systems. Over 90% of the mycobacteria isolated from water and deposits belonged to Mycobacterium lentiflavum, M. tusciae, M. gordonae, and a previously unclassified group of mycobacteria. Our results indicate that drinking water systems may be a source for recently discovered new mycobacterial species.  相似文献   

5.
Sphingomonadaceae (n = 86) were isolated from a drinking water treatment plant (n = 6), tap water (n = 55), cup fillers for dental chairs (n = 21), and a water demineralization filter (n = 4). The bacterial isolates were identified based on analysis of the 16S rRNA gene sequence, and intraspecies variation was assessed on the basis of atpD gene sequence analysis. The isolates were identified as members of the genera Sphingomonas (n = 27), Sphingobium (n = 28), Novosphingobium (n = 12), Sphingopyxis (n = 7), and Blastomonas (n = 12). The patterns of susceptibility to five classes of antibiotics were analyzed and compared for the different sites of isolation and taxonomic groups. Colistin resistance was observed to be intrinsic (92%). The highest antibiotic resistance prevalence values were observed in members of the genera Sphingomonas and Sphingobium and for beta-lactams, ciprofloxacin, and cotrimoxazole. In tap water and in water from dental chairs, antibiotic resistance was more prevalent than in the other samples, mainly due to the predominance of isolates of the genera Sphingomonas and Sphingobium. These two genera presented distinct patterns of association with antibiotic resistance, suggesting different paths of resistance development. Antibiotic resistance patterns were often related to the species rather than to the site or strain, suggesting the importance of vertical resistance transmission in these bacteria. This is the first study demonstrating that members of the family Sphingomonadaceae are potential reservoirs of antibiotic resistance in drinking water.  相似文献   

6.
A drinking water distribution system (DWDS) is the final and essential step to supply safe and high-quality drinking water to customers. Biological processes, such as biofilm formation and detachment, microbial growth in bulk water, and the formation of loose deposits, may occur. These processes will lead to deterioration of the water quality during distribution. In extreme conditions, pathogens and opportunistic pathogens may proliferate and pose a health risk to consumers. It is, therefore, necessary to understand the bacteriology of DWDSs to develop effective strategies that can ensure the water quality at consumers' taps. The bacteriology of DWDSs, both the quantitative growth and the qualitative bacterial community, has attracted considerable research attention. However, the researchers have focused mainly on the pipe wall biofilm. In this review, DWDS bacteriology has been reviewed multidimensionally, including both the bacterial quantification and identification. For the first time, the available literature was reviewed with an emphasis on the subdivision of DWDS into four phases: bulk water, suspended solids, loose deposits, and pipe wall biofilm. Special concentration has been given to potential contribution of particulate matter: suspended particles and loose deposits. Two highlighted questions were reviewed and discussed: (1) where does most of the growth occur? And (2) what is the contribution of particle-associated bacteria to DWDS bacteriology and ecology? At the end of this review, recommendations were given based on the conclusion of this review to better understand the integral DWDS bacteriology.  相似文献   

7.
Aromatic-degrading Sphingomonas isolates from the deep subsurface.   总被引:9,自引:3,他引:9       下载免费PDF全文
An obligately aerobic chemoheterotrophic bacterium (strain F199) previously isolated from Southeast Coastal Plain subsurface sediments and shown to degrade toluene, naphthalene, and other aromatic compounds (J. K. Fredrickson, F. J. Brockman, D. J. Workman, S. W. Li, and T. O. Stevens, Appl. Environ. Microbiol. 57:796-803, 1991) was characterized by analysis of its 16S rRNA nucleotide base sequence and cellular lipid composition. Strain F199 contained 2-OH14:0 and 18:1 omega 7c as the predominant cellular fatty acids and sphingolipids that are characteristic of the genus Sphingomonas. Phylogenetic analysis of its 16S rRNA sequence indicated that F199 was most closely related to Sphingomonas capsulata among the bacteria currently in the Ribosomal Database. Five additional isolates from deep Southeast Coastal Plain sediments were determined by 16S rRNA sequence analysis to be closely related to F199. These strains also contained characteristic sphingolipids. Four of these five strains could also grow on a broad range of aromatic compounds and could mineralize [14C]toluene and [14C]naphthalene. S. capsulata (ATCC 14666), Sphingomonas paucimobilis (ATCC 29837), and one of the subsurface isolates were unable to grow on any of the aromatic compounds or mineralize toluene or naphthalene. These results indicate that bacteria within the genus Sphingomonas are present in Southeast Coastal Plain subsurface sediments and that the capacity for degrading a broad range of substituted aromatic compounds appears to be common among Sphingomonas species from this environment.  相似文献   

8.
Microbial regrowth in drinking water distribution systems (DWDS) is a major concern in the water supply industry. Detailed knowledge of the microbial community in DWDS will be of great importance for assessing the microbiological risks of drinking water. The spatial heterogeneity of microbial community structures in the bulk waters of a large real DWDS was investigated using 16S rRNA clone library analysis. The results indicate that high residual chlorine in drinking water could not control microbial regrowth in DWDS. The bacterial communities in the bulk waters were spatially heterogenic, mainly composed of Alphaproteobacteria and Betaproteobacteria (or Cyanobacteria). Microorganisms from the genera Acinetobacter, Sphingomonas and Gemella were detected, implying there is microbiological risk from drinking water. This work provides new insight into microbial ecology in DWDS.  相似文献   

9.
Characterization of dysgonic, heterotrophic bacteria from drinking water   总被引:2,自引:0,他引:2  
Only a small percentage of the heterotrophic bacteria encountered in water distribution systems are identifiable, because of these organisms fail to grow on the conventional media used for biochemical characterization. Organisms that would not subculture from the same standard plate count agar used for initial isolation were successfully subcultured on a low-nutrient medium, R3A. These cultures were then inoculated to a modified O/F base medium containing specific substrates. This, combined with a lower incubation temperature (30 degrees C), increased the enzymatic activity of many of the organisms. These reactions established a groundwork for tentative taxonomy.  相似文献   

10.
Bacterial isolates from an unchlorinated potable groundwater system and a chlorinated surface water system were screened by an agar overlay method for the ability to produce bacteriocin-like substances (BLS) inhibitory to the growth of Escherichia coli, Klebsiella sp., and Enterobacter aerogenes. The production of coliform-specific BLS by noncoliform bacteria varied with the site and date of isolation as well as the genus of the producer strain. A total of 448 bacterial isolates were screened from the chlorinated system, and 22.1% produced BLS specific for at least one of the three coliforms. In the unchlorinated system, 7.9% (n = 696) possessed this ability. Flavobacterium/Moraxella comprised 57.1% of all bacteria (from both systems) producing BLS. The possibility that BLS interfere with coliform detection in standard bacteriological water quality tests is discussed.  相似文献   

11.
Ginige MP  Wylie J  Plumb J 《Biofouling》2011,27(2):151-163
Although health risk due to discoloured water is minimal, such water continues to be the source of one of the major complaints received by most water utilities in Australia. Elevated levels of iron (Fe) and/or manganese (Mn) in bulk water are associated with discoloured water incidents. The accumulation of these two elements in distribution systems is believed to be one of the main causes for such elevated levels. An investigation into the contribution of pipe wall biofilms towards Fe and Mn deposition, and discoloured water events is reported in this study. Eight laboratory-scale reactors were operated to test four different conditions in duplicate. Four reactors were exposed to low Fe (0.05 mg l(-1)) and Mn (0.02 mg l(-1)) concentrations and the remaining four were exposed to a higher (0.3 and 0.4 mg l(-1) for Fe and Mn, respectively) concentration. Two of the four reactors which received low and high Fe and Mn concentrations were chlorinated (3.0 mg l(-1) of chlorine). The biological activity (measured in terms of ATP) on the glass rings in these reactors was very low (~1.5 ng cm(-2) ring). Higher concentrations of Fe and Mn in bulk water and active biofilms resulted in increased deposition of Fe and Mn on the glass rings. Moreover, with an increase in biological activity, an increase in Fe and Mn deposition was observed. The observations in the laboratory-scale experiments were in line with the results of field observations that were carried out using biofilm monitors. The field data additionally demonstrated the effect of seasons, where increased biofilm activities observed on pipe wall biofilms during late summer and early autumn were found to be associated with increased deposition of Fe and Mn. In contrast, during the cooler months, biofilm activities were a magnitude lower and the deposited metal concentrations were also significantly less (ie a drop of 68% for Fe and 86% for Mn). Based on the laboratory-scale investigations, detachment of pipe wall biofilms due to cell death or flow dynamics could release the entrapped Fe and Mn into the bulk water, which could lead to a discoloured water event. Hence, managing biofilm growth on drinking water pipelines should be considered by water utilities to minimize accumulation of Fe and Mn in distribution networks.  相似文献   

12.
Although health risk due to discoloured water is minimal, such water continues to be the source of one of the major complaints received by most water utilities in Australia. Elevated levels of iron (Fe) and/or manganese (Mn) in bulk water are associated with discoloured water incidents. The accumulation of these two elements in distribution systems is believed to be one of the main causes for such elevated levels. An investigation into the contribution of pipe wall biofilms towards Fe and Mn deposition, and discoloured water events is reported in this study. Eight laboratory-scale reactors were operated to test four different conditions in duplicate. Four reactors were exposed to low Fe (0.05?mg?l?1) and Mn (0.02?mg?l?1) concentrations and the remaining four were exposed to a higher (0.3 and 0.4?mg?l?1 for Fe and Mn, respectively) concentration. Two of the four reactors which received low and high Fe and Mn concentrations were chlorinated (3.0?mg?l?1 of chlorine). The biological activity (measured in terms of ATP) on the glass rings in these reactors was very low (~1.5 ng cm?2 ring). Higher concentrations of Fe and Mn in bulk water and active biofilms resulted in increased deposition of Fe and Mn on the glass rings. Moreover, with an increase in biological activity, an increase in Fe and Mn deposition was observed. The observations in the laboratory-scale experiments were in line with the results of field observations that were carried out using biofilm monitors. The field data additionally demonstrated the effect of seasons, where increased biofilm activities observed on pipe wall biofilms during late summer and early autumn were found to be associated with increased deposition of Fe and Mn. In contrast, during the cooler months, biofilm activities were a magnitude lower and the deposited metal concentrations were also significantly less (ie a drop of 68% for Fe and 86% for Mn). Based on the laboratory-scale investigations, detachment of pipe wall biofilms due to cell death or flow dynamics could release the entrapped Fe and Mn into the bulk water, which could lead to a discoloured water event. Hence, managing biofilm growth on drinking water pipelines should be considered by water utilities to minimize accumulation of Fe and Mn in distribution networks.  相似文献   

13.
The Aeromonas populations in 13 Swedish drinking water distribution systems, representing different treatments, were investigated. From each system, water samples were collected four times during the period from May to September 1994 from raw water and water after treatment and at two to five sites within the distribution system. In total, 220 water samples were collected. From samples containing presumptive Aeromonas, up to 32 colonies were analyzed by the PhenePlate Aeromonas (PhP-AE) system, which is a highly discriminating biochemical fingerprinting method. Selected isolates from different phenotypes (PhP types) were further identified by the API 20 NE system and by gas-liquid chromatography analysis of fatty acid methyl esters (FAMEs). Selected isolates were also assayed for their potential to produce hemolysin and cytotoxin and for their ability to adhere to human intestinal cells. In total, 117 water samples (53%) contained presumptive Aeromonas which numbered up to 10(6) CFU/100 ml in raw water and up to 750 CFU/100 ml in tap water. Among the 2,117 isolates that were subjected to typing by the PhP-AE system, more than 300 distinct PhP types were found, of which the majority occurred only sporadically. Raw (surface) water samples usually contained many different PhP types, showing high diversity indices (Di) (median Di = 0.95). The Aeromonas populations in samples collected from within the distribution systems were less diverse (median Di = 0.58) and were often dominated by one major PhP type that was found on several sampling occasions. Seventeen such major PhP types could be found and were represented in 1,037 isolates (49%). Identification by API 20 NE and FAME analysis revealed that most of the major PhP types were Aeromonas hydrophila or belonged to unidentified Aeromonas species. Hemolysin and cytotoxin production was observed in most major PhP types (representing 87 and 54% of the assayed isolates, respectively), and adherence was found in 89% of the isolates that produced cytotoxin. Thus, the data presented here show that although raw water may contain very diverse Aeromonas populations, the populations seemed to be remarkably stable within the studied water distribution systems, and that some potentially pathogenic Aeromonas strains could persist for several months in drinking water.  相似文献   

14.
Aims:  This study investigated the effects of phosphorus on biofilm formation via annular reactor systems in terms of biofilm cell growth, exopolysaccharide (EPS) production, biofilm structure and cell metabolic potential.
Methods and Results:  Drinking water biofilms were developed in annular reactors with supplement of carbon and different levels of phosphorus. The biofilm formation was monitored over a period of 30 days. Biofilm related parameters were examined by various methods, which included heterotrophic plate count, total carbohydrate content, confocal laser scanning microscopy and GN2 microplate assay. Our results showed that phosphorus addition can promote the biofilm cell growth (cell count increased about 1 log with addition of 30 and 300 μg l−1 of phosphorus). However, the addition of 30 and 300 μg l−1 of phosphorus caused 81% and 77% decrease in EPS production, respectively. The results of biofilm structure analysis showed that the addition of 30 and 300 μg l−1 of phosphorus can induce thicker and less homogeneous biofilms with more biomass. Furthermore, the addition of 30 and 300 μg l−1 of phosphorus dramatically increased the biofilm cell metabolic potential. The addition of 3 μg l−1 of phosphorus was found to have minor effects on the parameters examined.
Conclusions:  The results indicate phosphorus addition to drinking water distribution system (DWDS) has a complicated effect on the biofilm formation.
Significance and Impact of the Study:  As the addition of phosphorus at certain levels can affect the biofilm growth in DWDS, care should be taken when phosphate-based corrosion inhibitors are used in the DWDS.  相似文献   

15.
In contrast to the notorious pathogens Mycobacterium tuberculosis and M. leprae, the majority of the mycobacterial species described to date are generally not considered as obligate human pathogens. The natural reservoirs of these non-primary pathogenic mycobacteria include aquatic and terrestrial environments. Under certain circumstances, e.g., skin lesions, pulmonary or immune dysfunctions and chronic diseases, these environmental mycobacteria (EM) may cause disease. EM such as M. avium, M. kansasii, and M. xenopi have frequently been isolated from drinking water and hospital water distribution systems. Biofilm formation, amoeba-associated lifestyle, and resistance to chlorine have been recognized as important factors that contribute to the survival, colonization and persistence of EM in water distribution systems. Although the presence of EM in tap water has been linked to nosocomial infections and pseudo-infections, it remains unclear if these EM provide a health risk for immunocompromised people, in particular AIDS patients. In this regard, control strategies based on maintenance of an effective disinfectant residual and low concentration of nutrients have been proposed to keep EM numbers to a minimum in water distribution systems.  相似文献   

16.
Only a small percentage of the heterotrophic bacteria encountered in water distribution systems are identifiable, because of these organisms fail to grow on the conventional media used for biochemical characterization. Organisms that would not subculture from the same standard plate count agar used for initial isolation were successfully subcultured on a low-nutrient medium, R3A. These cultures were then inoculated to a modified O/F base medium containing specific substrates. This, combined with a lower incubation temperature (30 degrees C), increased the enzymatic activity of many of the organisms. These reactions established a groundwork for tentative taxonomy.  相似文献   

17.
In this study, to give insight into the bacterial diversity of biofilms from full-scale drinking water distribution systems (DWDSs), the bacterial community compositions of biofilms from two urban DWDSs (Guangzhou and Beijing, China) were determined using a 16S rRNA gene library technique. Meanwhile, the occurrence and diversity of mycobacteria were also analyzed by a Mycobacterium -specific hsp gene assay. The biofilms from the full-scale DWDSs have complex bacterial populations. Proteobacteria was the common and predominant group in all biofilm samples, in agreement with previous reports. The community structures of bacteria at the three sites in Guangzhou DWDS were significantly different, despite the similar physicochemical properties of portable water. Some abundant and peculiar bacterial phylotypes were noteworthy, including Methylophilus , Massilia, and Planomicrobium , members of which are rarely found in DWDSs and their roles in DWDS biofilms are still unclear. The diversity of Mycobacterium species in biofilm samples was rather low. Mycobacterium arupense and Mycobacterium gordonae were the primary Mycobacterium species in Guangzhou and Beijing biofilms, respectively, indicating that M. arupense may be more resistant to chloride than M. gordonae.  相似文献   

18.
19.
AIMS: To investigate treated water distribution systems in England as a source of Helicobacter pylori. METHODS AND RESULTS: Water and biofilms were obtained from 11 domestic and seven educational properties and from hydrants, reservoirs and water meters supplied by three water utilities. Samples were cultured on nonselective and antibiotic containing media combined with immunomagnetic separation concentration. Viable helicobacters were not detected in any of the 151 samples but Helicobacter-specific PCR assays detected DNA in 26% of samples from domestic properties, schools and hydrants with the highest frequency in biofilms (42%). Direct sequencing of six selected amplicons confirmed >95% sequence homology to H. pylori. CONCLUSIONS: While viable helicobacters were not isolated, evidence was obtained for the presence of Helicobacter DNA, including that of H. pylori. Biofilms on surfaces within water distribution systems may act either as sites for the passive accumulation of helicobacters or as potentially important reservoirs of infection. SIGNIFICANCE AND IMPACT OF THE STUDY: Our findings strengthen evidence that H. pylori may be transmitted through drinking water. However, there is currently no evidence that viable cells can survive the disinfection levels used in UK mains supplies and the health risk from this source remains unclear.  相似文献   

20.
Wang  Yang  Zhang  Xiaojian  Feng  Shuo  Niu  Zhangbin  Chen  Chao 《Annals of microbiology》2009,59(2):353-358
To study the inactivation characteristic of iron bacteria isolated from real drinking water distribution systems and investigate the influence of disinfectants, pH and temperature on inactivation process. Two kinds of iron bacteria were isolated from the water phase in distribution systems and identified asAcinetobacter baumannii andMicrobacterium oxydans. Bench-scale study on inactivation of the two kinds of iron bacteria were carried out, with the impact of disinfectants, pH and temperature under different levels concerned. Free chlorine and monochloramine could achieve an inactivation rate of 99.9% on bothA. Baumannii andM. Oxydans with the CT-value of 10 mg/L·min. Free chlorine was more effective than monochloramine with 1∼2 log higher inactivation rate.Microbacterium oxydans was more resistant to disinfectant thanA. Baumannii. High pH enhanced the inactivation of A.baumannii and low temperature availed the inactivation of bothA. Baumannii andMicrobacterium. For iron bacteria in the water, inactivation ratio could not reach 99% when residual chlorine was 0.05 mg/L in drinking water distribution systems according to Standards for Drinking Water Quality.  相似文献   