首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Atomic force spectroscopy is an ideal tool to study molecules at surfaces and interfaces. An experimental protocol to couple a large variety of single molecules covalently onto an AFM tip is presented. At the same time the AFM tip is passivated to prevent unspecific interactions between the tip and the substrate, which is a prerequisite to study single molecules attached to the AFM tip. Analyses to determine the adhesion force, the adhesion length, and the free energy of these molecules on solid surfaces and bio-interfaces are shortly presented and external references for further reading are provided. Example molecules are the poly(amino acid) polytyrosine, the graft polymer PI-g-PS and the phospholipid POPE (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanolamine). These molecules are desorbed from different surfaces like CH3-SAMs, hydrogen terminated diamond and supported lipid bilayers under various solvent conditions. Finally, the advantages of force spectroscopic single molecule experiments are discussed including means to decide if truly a single molecule has been studied in the experiment.  相似文献   

2.
Single molecule force spectroscopy methods, such as optical and magnetic tweezers and atomic force microscopy, have opened up the possibility to study biological processes regulated by force, dynamics of structural conformations of proteins and nucleic acids, and load-dependent kinetics of molecular interactions. Among the various tools available today, optical tweezers have recently seen great progress in terms of spatial resolution, which now allows the measurement of atomic-scale conformational changes, and temporal resolution, which has reached the limit of the microsecond-scale relaxation times of biological molecules bound to a force probe. Here, we review different strategies and experimental configurations recently developed to apply and measure force using optical tweezers. We present the latest progress that has pushed optical tweezers’ spatial and temporal resolution down to today’s values, discussing the experimental variables and constraints that are influencing measurement resolution and how these can be optimized depending on the biological molecule under study.  相似文献   

3.
Single molecule force spectroscopy methods, such as optical and magnetic tweezers and atomic force microscopy, have opened up the possibility to study biological processes regulated by force, dynamics of structural conformations of proteins and nucleic acids, and load-dependent kinetics of molecular interactions. Among the various tools available today, optical tweezers have recently seen great progress in terms of spatial resolution, which now allows the measurement of atomic-scale conformational changes, and temporal resolution, which has reached the limit of the microsecond-scale relaxation times of biological molecules bound to a force probe. Here, we review different strategies and experimental configurations recently developed to apply and measure force using optical tweezers. We present the latest progress that has pushed optical tweezers’ spatial and temporal resolution down to today’s values, discussing the experimental variables and constraints that are influencing measurement resolution and how these can be optimized depending on the biological molecule under study.  相似文献   

4.
Titin plays crucial roles in sarcomere organization and cardiac elasticity by acting as an intrasarcomeric molecular spring. A mutation in the tenth Ig-like domain of titin''s spring region is associated with arrhythmogenic cardiomyopathy, a disease characterized by ventricular arrhythmias leading to cardiac arrest and sudden death. Titin is the first sarcomeric protein linked to arrhythmogenic cardiomyopathy. To characterize the disease mechanism, we have used atomic force microscopy to directly measure the effects that the disease-linked point mutation (T16I) has on the mechanical and kinetic stability of Ig10 at the single molecule level. The mutation decreases the force needed to unfold Ig10 and increases its rate of unfolding 4-fold. We also found that T16I Ig10 is more prone to degradation, presumably due to compromised local protein structure. Overall, the disease-linked mutation weakens the structural integrity of titin''s Ig10 domain and suggests an Ig domain disease mechanism.  相似文献   

5.
《Biophysical journal》2020,118(5):1101-1108
Single molecule photobleaching is a powerful technique to measure the number of fluorescent units in subresolution molecular complexes, such as in toxic protein oligomers associated with amyloid diseases. However, photobleaching can occur before the sample is appropriately placed and focused. Such “prebleaching” can introduce a strong systematic bias toward smaller oligomers. Quantitative correction of prebleaching is known to be an ill-posed problem, limiting the utility of the technique. Here, we provide an experimental solution to improve its reliability. We chemically construct multimeric standards to estimate the prebleaching probability, B. We show that B can be used as a constraint to reliably correct the statistics obtained from a known distribution of standard oligomers. Finally, we apply this method to the data obtained from a heterogeneous oligomeric solution of human islet amyloid polypeptide. Our results show that photobleaching can critically skew the estimation of oligomeric distributions, so that low abundance monomers display a much higher apparent abundance. In summary, any inference from photobleaching experiments with B > 0.1 is likely to be unreliable, but our method can be used to quantitatively correct possible errors.  相似文献   

6.
The conformational diffusion coefficient for intrachain motions in biopolymers, D, sets the timescale for structural dynamics. Recently, force spectroscopy has been applied to determine D both for unfolded proteins and for the folding transitions in proteins and nucleic acids. However, interpretation of the results remains unsettled. We investigated how instrumental effects arising from the force probes used in the measurement can affect the value of D recovered via force spectroscopy. We compared estimates of D for the folding of DNA hairpins found from measurements of rates and energy landscapes made using optical tweezers with estimates obtained from the same single-molecule trajectories via the transition path time. The apparent D obtained from the rates was much lower than the result found from the same data using transition time analysis, reflecting the effects of the mechanical properties of the force probe. Deconvolution of the finite compliance effects on the measurement allowed the intrinsic value to be recovered. These results were supported by Brownian dynamics simulations of the effects of force-probe compliance and bead size.  相似文献   

7.
The conformational diffusion coefficient for intrachain motions in biopolymers, D, sets the timescale for structural dynamics. Recently, force spectroscopy has been applied to determine D both for unfolded proteins and for the folding transitions in proteins and nucleic acids. However, interpretation of the results remains unsettled. We investigated how instrumental effects arising from the force probes used in the measurement can affect the value of D recovered via force spectroscopy. We compared estimates of D for the folding of DNA hairpins found from measurements of rates and energy landscapes made using optical tweezers with estimates obtained from the same single-molecule trajectories via the transition path time. The apparent D obtained from the rates was much lower than the result found from the same data using transition time analysis, reflecting the effects of the mechanical properties of the force probe. Deconvolution of the finite compliance effects on the measurement allowed the intrinsic value to be recovered. These results were supported by Brownian dynamics simulations of the effects of force-probe compliance and bead size.  相似文献   

8.
Understanding the structural organization and distribution of proteins in biological cells is of fundamental importance in biomedical research. The use of conventional fluorescent microscopy for this purpose is limited due to its relatively low spatial resolution compared to the size of a single protein molecule. Atomic force microscopy (AFM), on the other hand, allows one to achieve single-protein resolution by scanning the cell surface using a specialized ligand-coated AFM tip. However, because this method relies on short-range interactions, it is limited to the detection of binding sites that are directly accessible to the AFM tip. We developed a method based on magnetic (long-range) interactions and applied it to investigate the structural organization and distribution of endothelin receptors on the surface of smooth muscle cells. Endothelin receptors were labeled with 50-nm superparamagnetic microbeads and then imaged with magnetic AFM. Considering its high spatial resolution and ability to “see” magnetically labeled proteins at a distance of up to 150 nm, this approach may become an important tool for investigating the dynamics of individual proteins both on the cell membrane and in the submembrane space.  相似文献   

9.
Fluorescence Resonance Energy Transfer (FRET) microscopy has been widely used to study the structure and dynamics of molecules of biological interest, such as nucleic acids and proteins. Single molecule FRET (sm-FRET) measurements on immobilized molecules permit long observations of the system -effectively until both dyes photobleach- resulting in time-traces that report on biomolecular dynamics with a broad range of timescales from milliseconds to minutes. To facilitate the acquisition of large number of traces for statistical analyses, the process must be automated and the sample environment should be tightly controlled over the entire measurement time (~12 hours). This is accomplished using an automated scanning confocal microscope that allows the interrogation of thousands of single molecules overnight, and a microfluidic cell that permits the controlled exchange of buffer, with restricted oxygen content and maintains a constant temperature throughout the entire measuring period. Here we show how to assemble the microfluidic device and how to activate its surface for DNA immobilization. Then we explain how to prepare a buffer to maximize the photostability and lifetime of the fluorophores. Finally, we show the steps involved in preparing the setup for the automated acquisition of time-resolved single molecule FRET traces of DNA molecules.  相似文献   

10.
Single molecule force spectroscopy was employed to investigate the dynamics of the sodium glucose co-transporter (SGLT1) upon substrate and inhibitor binding on the single molecule level. CHO cells stably expressing rbSGLT1 were probed by using atomic force microscopy tips carrying either thioglucose, 2′-aminoethyl β-d-glucopyranoside, or aminophlorizin. Poly(ethylene glycol) (PEG) chains of different length and varying end groups were used as tether. Experiments were performed at 10, 25 and 37 °C to address different conformational states of SGLT1. Unbinding forces between ligands and SGLT1 were recorded at different loading rates by changing the retraction velocity, yielding binding probability, width of energy barrier of the binding pocket, and the kinetic off rate constant of the binding reaction. With increasing temperature, width of energy barrier and average life time increased for the interaction of SGLT1 with thioglucose (coupled via acrylamide to a long PEG) but decreased for aminophlorizin binding. The former indicates that in the membrane-bound SGLT1 the pathway to sugar translocation involves several steps with different temperature sensitivity. The latter suggests that also the aglucon binding sites for transport inhibitors have specific, temperature-sensitive conformations.  相似文献   

11.
We have developed an imaging system that combines the soft compliance of an optical trap with the sensitivity of single particle tracking to image forces on/in live cells using a single molecule probe. The probe used is a single (or few) molecule of interest that is conjugated with a single 40 nm colloidalgold probe. The colloidal gold/membrane protein complex, freely diffusing on a live cell, is held in a laser trap while the cell is scanned underneath. Computer control allows for synchronization of the cell scan and capture of the probe position. Resistance to the dragging of the probe images a fine structure of barriers in the membrane of live cells.  相似文献   

12.
Fluorescence assay technologies used for miniaturized high throughput screening are broadly divided into two classes. Macroscopic fluorescence techniques (encompassing conventional fluorescence intensity, anisotropy [also often referred to as fluorescence polarization] and energy transfer) monitor the assay volume- and time-averaged fluorescence output from the ensemble of emitting fluorophores. In contrast, single-molecule detection (SMD) techniques and related approaches, such as fluorescence correlation spectroscopy (FCS), stochastically sample the fluorescence properties of individual constituent molecules and only then average many such detection events to define the properties of the assay system as a whole. Analysis of single molecular events is accomplished using confocal optics with an illumination/detection volume of approximately 1 fl (10(-15) L) such that the signal is insensitive to miniaturization of HTS assays to 1 μl or below. In this report we demonstrate the general applicability of one SMD technique (FCS) to assay configuration for target classes typically encountered in HTS and confirm the equivalence of the rate/equilibrium constants determined by FCS and by macroscopic techniques. Advantages and limitations of the current FCS technology, as applied here, and potential solutions, particularly involving alternative SMD detection techniques, are also discussed.  相似文献   

13.
Folding and unfolding are fundamental biological processes in cell and are important for the biological functions of proteins. Characterizing the folding and unfolding kinetics of proteins is important for understanding the energetic landscape leading to the active native conformations of these molecules. However, the thermal or chemical-induced unfolding of many proteins is irreversible in vitro, precluding characterization of the folding kinetics of such proteins, just as it is impossible to “un-boil” an egg. Irreversible unfolding often manifests as irreversible aggregation of unfolded polypeptide chains, which typically occurs between denatured protein molecules in response to the exposure of hydrophobic residues to solvent. An example of such a protein where thermal denaturation results in irreversible aggregation is the β-1,4 endoxylanase from Bacillus circulans (BCX). Here, we report the use of single-molecule atomic force microscopy to directly measure the folding kinetics of BCX in vitro. By mechanically unfolding BCX, we essentially allowed only one unfolded molecule to exist in solution at a given time, effectively eliminating the possibility for aggregation. We found that BCX can readily refold back to the native state, allowing us to measure its folding kinetics for the first time. Our results demonstrate that single-molecule force-spectroscopy-based methods can adequately tackle the challenge of “un-boiling eggs”, providing a general methodology to characterize the folding kinetics of many proteins that suffer from irreversible denaturation and thus cannot be characterized using traditional equilibrium methodologies.  相似文献   

14.
Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.  相似文献   

15.
生命活动过程与生物分子内或生物分子间机械力的作用密不可分.原子力显微镜具有极高的力学分辨率,可以在近生理条件下对生物样品进行力学测量,是研究生物体系力学相互作用的理想工具.基于原子力显微镜的单分子力谱(AFM-SMFS)技术可以在单分子、单细胞水平测量生物分子内或生物分子间的相互作用.本文首先扼要介绍了AFM-SMFS技术,包括AFM-SMFS的基本原理、力谱测量及分析方法(蠕虫链模型、自由连接链模型和自由旋转链模型)以及探针的化学修饰方法(硅/氮化硅探针和镀金探针的修饰);重点介绍了利用AFM-SMFS技术对活体细胞表面蛋白(转化生长因子β1、CD20、热休克蛋白以及蛋白酪氨酸激酶)和糖类分子(葡萄糖和甘露糖)的近期研究进展;随后介绍了利用AFM-SMFS技术对活菌体表面蛋白(肝素结合血凝黏附素和Als5p黏附蛋白)和糖类分子(半乳糖、甘露糖、B族碳水化合物、荚膜多糖、α-甘露聚糖、β-甘露聚糖、β-葡聚糖以及几丁质)的近期研究进展;最后对AFM-SMFS技术的缺点和发展前景进行了总结和展望.  相似文献   

16.
17.
Abstract

Identification and manipulation of molecules on the single molecule level is best done in microstructures. The capability of observing single dye molecules in microstructures is demonstrated. Single molecules of DNA (106 bp) labelled with the intercalating dye TO-PRO-1 could also be observed.  相似文献   

18.
早诊断、早发现、早治疗是提升肿瘤患者生存率的主要手段。临床常用的免疫学检测方法如酶联免疫吸附法、化学发光法等,其检测灵敏度多限制在10-14~10-12 mol/L,无法满足早期诊断的需求。单分子免疫检测法,可将待检测分子限制在极小空间范围内(nL以下),对检测信号进行绝对计数,从而实现痕量(可达10-18 mol/L)标志物的检测。这一超高灵敏度技术实现的关键在于将检测范围限制在极小体积内。经过数十年发展,不论是物理隔离还是利用纳米孔,抑或通过改进显微镜性能,均可在极小体积内(10-21 L)对信号进行检测。目前基于微阵列的SimoA检测系统已成为单分子免疫检测的金标准,Quanterix公司基于此开发的HD-1分析仪已进入市场应用。基于微液滴的单分子免疫检测技术主要限于实验室,但具有床旁检测的优势。重点介绍了基于物理隔离形式如微阵列和微液滴的单分子免疫检测进展,为进一步开发超高灵敏度检测方法并促进未来临床应用提供理论基础。  相似文献   

19.
Active cell migration and invasion is a peculiar feature of glioma that makes this tumor able to rapidly infiltrate into the surrounding brain tissue. In our recent work, we identified a novel class of glioma-associated-stem cells (defined as GASC for high-grade glioma -HG- and Gasc for low-grade glioma -LG-) that, although not tumorigenic, act supporting the biological aggressiveness of glioma-initiating stem cells (defined as GSC for HG and Gsc for LG) favoring also their motility. Migrating cancer cells undergo considerable molecular and cellular changes by remodeling their cytoskeleton and cell interactions with surrounding environment. To get a better understanding about the role of the glioma-associated-stem cells in tumor progression, cell deformability and interactions between glioma-initiating stem cells and glioma-associated-stem cells were investigated. Adhesion of HG/LG-cancer cells on HG/LG-glioma-associated stem cells was studied by time-lapse microscopy, while cell deformability and cell-cell adhesion strengths were quantified by indentation measurements by atomic force microscopy and single cell force spectroscopy. Our results demonstrate that for both HG and LG glioma, cancer-initiating-stem cells are softer than glioma-associated-stem cells, in agreement with their neoplastic features. The adhesion strength of GSC on GASC appears to be significantly lower than that observed for Gsc on Gasc. Whereas, GSC spread and firmly adhere on Gasc with an adhesion strength increased as compared to that obtained on GASC. These findings highlight that the grade of glioma-associated-stem cells plays an important role in modulating cancer cell adhesion, which could affect glioma cell migration, invasion and thus cancer aggressiveness. Moreover this work provides evidence about the importance of investigating cell adhesion and elasticity for new developments in disease diagnostics and therapeutics.  相似文献   

20.
单分子PCR产物错误率分析   总被引:6,自引:0,他引:6  
碱基错配致使PCR扩增产物中存在突变序列.大量模板PCR扩增时突变序列所占的比例较低,对随后进行的PCR产物分析影响不大,但当对微量甚至单个模板DNA扩增时,情况则完全不同.对单分子PCR产物的错误率进行了理论分析,结果表明:根据实验目的和条件,选择忠实性不同的聚合酶是十分关键的.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号