首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
This study employs the finite element approach developed in Part I to analyze mechanical experiments on cells. It views cells as axisymmetric membrane structures containing a body of incompressible material, and models the mechanical contact between a cell and the loading apparatus by a contact algorithm. Since the method is valid for analyzing axisymmetric shell-like bodies with arbitrary shapes, it treates various mechanical experiments on cells in a unified manner. For demonstration purposes, three commonly used mechanical experiments on cells are considered; the compression experiment; the suction (micropipette aspiration) experiment; and the magnetic particle experiment. Based on an estimate of the mechanical property data for unfertilized sea urchin eggs, this analysis method predicts the responses for all three experiments using the same assumptions and approximations. This parallel treatment gives a broad basis for data correlation with experiments. The method also provides insights into mechanical experiments not offered by other approximate methods. For example, it gives the distributions of tensions and stretches on the cell cortex, and suggests the role of friction in the suction experiment.  相似文献   

2.
This study addresses the issue of modelling material heterogeneity of incompressible bodies. It is seen that when using a mixed (displacement–pressure) finite element formulation, the basis functions used for pressure field may not be able to capture the nonlinearity of material parameters, resulting in pseudo-residual stresses. This problem can be resolved by modifying the constitutive relation using Flory's decomposition of the deformation gradient. A two-parameter Mooney–Rivlin constitutive relation is used to demonstrate the methodology. It is shown that for incompressible materials, the modification does not alter the mechanical behaviour described by the original constitutive model. In fact, the modified constitutive equation shows a better predictability when compared against analytical solutions. Two strategies of describing the material variation (i.e. linear and step change) are explained, and their solutions are evaluated for an ideal two-material interfacing problem. When compared with the standard tied coupling approach, the step change method exhibited a much better agreement because of its ability to capture abrupt changes of the material properties. The modified equation in conjunction with integration point-based material heterogeneity is then used to simulate the deformations of heterogeneous biological structures to illustrate its applications.  相似文献   

3.
A finite element analysis is used to study a previously unresolved issue of the effects of platen-specimen friction on the response of the unconfined compression test; effects of platen permeability are also determined. The finite element formulation is based on the linear KLM biphasic model for articular cartilage and other hydrated soft tissues. A Galerkin weighted residual method is applied to both the solid phase and the fluid phase, and the continuity equation for the intrinsically incompressible binary mixture is introduced via a penalty method. The solid phase displacements and fluid phase velocities are interpolated for each element in terms of unknown nodal values, producing a system of first order differential equations which are solved using a standard numerical finite difference technique. An axisymmetric element of quadrilateral cross-section is developed and applied to the mechanical test problem of a cylindrical specimen of soft tissue in unconfined compression. These studies show that interfacial friction plays a major role in the unconfined compression response of articular cartilage specimens with small thickness to diameter ratios.  相似文献   

4.
Real-time soft tissue modeling has a potential application in medical training, procedure planning and image-guided therapy. This paper characterizes the mechanical properties of organ tissue using a hyperelastic material model, an approach which is then incorporated into a real-time finite element framework. While generalizable, in this paper we use the published mechanical properties of pig liver to characterize an example application. Specifically, we calibrate the parameters of an exponential model, with a least-squares method (LSM) using the assumption that the material is isotropic and incompressible in a uniaxial compression test. From the parameters obtained, the stress–strain curves generated from the LSM are compared to those from the corresponding computational model solved by ABAQUS and also to experimental data, resulting in mean errors of 1.9 and 4.8%, respectively, which are considerably better than those obtained when employing the Neo-Hookean model. We demonstrate our approach through the simulation of a biopsy procedure, employing a tetrahedral mesh representation of human liver generated from a CT image. Using the material properties along with the geometric model, we develop a nonlinear finite element framework to simulate the behaviour of liver during an interventional procedure with a real-time performance achieved through the use of an interpolation approach.  相似文献   

5.
A real time hyperelastic tissue model   总被引:1,自引:0,他引:1  
Real-time soft tissue modeling has a potential application in medical training, procedure planning and image-guided therapy. This paper characterizes the mechanical properties of organ tissue using a hyperelastic material model, an approach which is then incorporated into a real-time finite element framework. While generalizable, in this paper we use the published mechanical properties of pig liver to characterize an example application. Specifically, we calibrate the parameters of an exponential model, with a least-squares method (LSM) using the assumption that the material is isotropic and incompressible in a uniaxial compression test. From the parameters obtained, the stress-strain curves generated from the LSM are compared to those from the corresponding computational model solved by ABAQUS and also to experimental data, resulting in mean errors of 1.9 and 4.8%, respectively, which are considerably better than those obtained when employing the Neo-Hookean model. We demonstrate our approach through the simulation of a biopsy procedure, employing a tetrahedral mesh representation of human liver generated from a CT image. Using the material properties along with the geometric model, we develop a nonlinear finite element framework to simulate the behaviour of liver during an interventional procedure with a real-time performance achieved through the use of an interpolation approach.  相似文献   

6.
The mechanical properties of tissue engineering scaffolds play a critical role in the success of repairing damaged tissues/organs. Determining the mechanical properties has proven to be a challenging task as these properties are not constant but depend upon time as the scaffold degrades. In this study, the modeling of the time-dependent mechanical properties of a scaffold is performed based on the concept of finite element model updating. This modeling approach contains three steps: (1) development of a finite element model for the effective mechanical properties of the scaffold, (2) parametrizing the finite element model by selecting parameters associated with the scaffold microstructure and/or material properties, which vary with scaffold degradation, and (3) identifying selected parameters as functions of time based on measurements from the tests on the scaffold mechanical properties as they degrade. To validate the developed model, scaffolds were made from the biocompatible polymer polycaprolactone (PCL) mixed with hydroxylapatite (HA) nanoparticles and their mechanical properties were examined in terms of the Young modulus. Based on the bulk degradation exhibited by the PCL/HA scaffold, the molecular weight was selected for model updating. With the identified molecular weight, the finite element model developed was effective for predicting the time-dependent mechanical properties of PCL/HA scaffolds during degradation.  相似文献   

7.
An axisymmetric deformation of a viscoelastic sphere bounded by a prestressed elastic thin shell in response to external pressure is studied by a finite element method. The research is motivated by the need for understanding the passive behavior of human leukocytes (white blood cells) and interpreting extensive experimental data in terms of the mechanical properties. The cell at rest is modeled as a sphere consisting of a cortical prestressed shell with incompressible Maxwell fluid interior. A large-strain deformation theory is developed based on the proposed model. General non-linear, large strain constitutive relations for the cortical shell are derived by neglecting the bending stiffness. A representation of the constitutive equations in the form of an integral of strain history for the incompressible Maxwell interior is used in the formulation of numerical scheme. A finite element program is developed, in which a sliding boundary condition is imposed on all contact surfaces. The mathematical model developed is applied to evaluate experimental data of pipette tests and observations of blood flow.  相似文献   

8.
A simple axisymmetric finite element model of a human spine segment containing two adjacent vertebrae and the intervening intervertebral disc was constructed. The bodies and disc were modeled by three substructures; one to represent each of the vertebral bodies, the annulus fibrosus, and the nucleus pulposus. A semi-analytic technique was used to maintain the computational economies of a two-dimensional analysis when non- axisymmetric loads were imposed on the model. The response of the model to compression, shear, torsion and bending loads applied to the superior vertebral body was examined to determine the effects of disc geometry and material properties on response. Comparisons of model responses with experimentally measured responses were made to estimate material property values for which model behaviors are in agreement with measured behaviors.  相似文献   

9.
In this paper we present a mixed finite element method for modeling the passive properties of the myocardium. The passive properties are described by a non-linear, transversely isotropic, hyperelastic material model, and the myocardium is assumed to be almost incompressible. Single-field, pure displacement-based formulations are known to cause numerical difficulties when applied to incompressible or slightly compressible material cases. This paper presents an alternative approach in the form of a mixed formulation, where a separately interpolated pressure field is introduced as a primary unknown in addition to the displacement field. Moreover, a constraint term is included in the formulation to enforce (almost) incompressibility. Numerical results presented in the paper demonstrate the difficulties related to employing a pure displacement-based method, applying a set of physically relevant material parameter values for the cardiac tissue. The same problems are not experienced for the proposed mixed method. We show that the mixed formulation provides reasonable numerical results for compressible as well as nearly incompressible cases, also in situations of large fiber stretches. There is good agreement between the numerical results and the underlying analytical models.  相似文献   

10.
In this paper we present a mixed finite element method for modeling the passive properties of the myocardium. The passive properties are described by a non-linear, transversely isotropic, hyperelastic material model, and the myocardium is assumed to be almost incompressible. Single-field, pure displacement-based formulations are known to cause numerical difficulties when applied to incompressible or slightly compressible material cases. This paper presents an alternative approach in the form of a mixed formulation, where a separately interpolated pressure field is introduced as a primary unknown in addition to the displacement field. Moreover, a constraint term is included in the formulation to enforce (almost) incompressibility. Numerical results presented in the paper demonstrate the difficulties related to employing a pure displacement-based method, applying a set of physically relevant material parameter values for the cardiac tissue. The same problems are not experienced for the proposed mixed method. We show that the mixed formulation provides reasonable numerical results for compressible as well as nearly incompressible cases, also in situations of large fiber stretches. There is good agreement between the numerical results and the underlying analytical models.  相似文献   

11.
Biological soft tissues and cells may be subjected to mechanical as well as chemical (osmotic) loading under their natural physiological environment or various experimental conditions. The interaction of mechanical and chemical effects may be very significant under some of these conditions, yet the highly nonlinear nature of the set of governing equations describing these mechanisms poses a challenge for the modeling of such phenomena. This study formulated and implemented a finite element algorithm for analyzing mechanochemical events in neutral deformable porous media under finite deformation. The algorithm employed the framework of mixture theory to model the porous permeable solid matrix and interstitial fluid, where the fluid consists of a mixture of solvent and solute. A special emphasis was placed on solute-solid matrix interactions, such as solute exclusion from a fraction of the matrix pore space (solubility) and frictional momentum exchange that produces solute hindrance and pumping under certain dynamic loading conditions. The finite element formulation implemented full coupling of mechanical and chemical effects, providing a framework where material properties and response functions may depend on solid matrix strain as well as solute concentration. The implementation was validated using selected canonical problems for which analytical or alternative numerical solutions exist. This finite element code includes a number of unique features that enhance the modeling of mechanochemical phenomena in biological tissues. The code is available in the public domain, open source finite element program FEBio (http:∕∕mrl.sci.utah.edu∕software).  相似文献   

12.
Analytical and finite element models (FEMs) were used to quantify poroelastic material properties for a human intervertebral disk. An axisymmetric FEM based on a poroelastic view of disk constituents was developed for a representative human spinal motion segment (SMS). Creep and steady-state response predicted by FEMs agreed with experimental observations, i.e., long-time creep occurs with flow in the SMS, whereas for rapid steady-state loading an "undrained," nearly incompressible response is evident. A relatively low value was determined for discal permeability. Transient and long-term creep FE analyses included the study of deformation, pore fluid flow, stress, and pore fluid pressure. Relative fluid motion associated with transient creep is related to nuclear nutrition and the overall mechanical response in the normal disk. Degeneration of the disk may be associated with an increase in permeability.  相似文献   

13.
A novel finite element approach is presented to simulate the mechanical behavior of human red blood cells (RBC, erythrocytes). As the RBC membrane comprises a phospholipid bilayer with an intervening protein network, we propose to model the membrane with two distinct layers. The fairly complex characteristics of the very thin lipid bilayer are represented by special incompressible solid shell elements and an anisotropic viscoelastic constitutive model. Properties of the protein network are modeled with an isotropic hyperelastic third-order material. The elastic behavior of the model is validated with existing optical tweezers studies with quasi-static deformations. Employing material parameters consistent with literature, simulation results are in excellent agreement with experimental data. Available models in literature neglect either the surface area conservation of the RBC membrane or realistic loading conditions of the optical tweezers experiments. The importance of these modeling assumptions, that are both included in this study, are discussed and their influence quantified. For the simulation of the dynamic motion of RBC, the model is extended to incorporate the cytoplasm. This is realized with a monolithic fully coupled fluid-structure interaction simulation, where the fluid is described by the incompressible Navier–Stokes equations in an arbitrary Lagrangian Eulerian framework. It is shown that both membrane viscosity and cytoplasm viscosity have significant influence on simulation results. Characteristic recovery times and energy dissipation for varying strain rates in dynamic laser trap experiments are calculated for the first time and are found to be comparable with experimental data.  相似文献   

14.
Standard methods for predicting bone’s mechanical response from quantitative computer tomography (qCT) scans are mainly based on classical h-version finite element methods (FEMs). Due to the low-order polynomial approximation, the need for segmentation and the simplified approach to assign a constant material property to each element in h-FE models, these often compromise the accuracy and efficiency of h-FE solutions. Herein, a non-standard method, the finite cell method (FCM), is proposed for predicting the mechanical response of the human femur. The FCM is free of the above limitations associated with h-FEMs and is orders of magnitude more efficient, allowing its use in the setting of computational steering. This non-standard method applies a fictitious domain approach to simplify the modeling of a complex bone geometry obtained directly from a qCT scan and takes into consideration easily the heterogeneous material distribution of the various bone regions of the femur. The fundamental principles and properties of the FCM are briefly described in relation to bone analysis, providing a theoretical basis for the comparison with the p-FEM as a reference analysis and simulation method of high quality. Both p-FEM and FCM results are validated by comparison with an in vitro experiment on a fresh-frozen femur.  相似文献   

15.
A two-dimensional incompressible plane-stress finite element is formulated for the simulation of the passive-state mechanics of thin myocardial strips. The formulation employs a total Lagrangian and materially nonlinear approach, being based on a recently proposed structural material law, which is derived from the histological composition of the tissue. The ensuing finite element allows to demonstrate the mechanical properties of a single myocardial layer containing uniformly directed fibers by simulating various loading cases such as tension, compression and shear. The results of these cases show that the fiber direction is considerably stiffer than the cross-fiber direction, that there is significant coupling between these two directions, and that the shear stiffness of the tissue is lower than its tensile and compressive stiffness.  相似文献   

16.
Finite element modelling of contracting skeletal muscle   总被引:2,自引:0,他引:2  
To describe the mechanical behaviour of biological tissues and transport processes in biological tissues, conservation laws such as conservation of mass, momentum and energy play a central role. Mathematically these are cast into the form of partial differential equations. Because of nonlinear material behaviour, inhomogeneous properties and usually a complex geometry, it is impossible to find closed-form analytical solutions for these sets of equations. The objective of the finite element method is to find approximate solutions for these problems. The concepts of the finite element method are explained on a finite element continuum model of skeletal muscle. In this case, the momentum equations have to be solved with an extra constraint, because the material behaves as nearly incompressible. The material behaviour consists of a highly nonlinear passive part and an active part. The latter is described with a two-state Huxley model. This means that an extra nonlinear partial differential equation has to be solved. The problems and solutions involved with this procedure are explained. The model is used to describe the mechanical behaviour of a tibialis anterior of a rat. The results have been compared with experimentally determined strains at the surface of the muscle. Qualitatively there is good agreement between measured and calculated strains, but the measured strains were higher.  相似文献   

17.
This study deals with the viscoelastic constitutive modeling and the respective computational analysis of the human passive myocardium. We start by recapitulating the locally orthotropic inner structure of the human myocardial tissue and model the mechanical response through invariants and structure tensors associated with three orthonormal basis vectors. In accordance with recent experimental findings the ventricular myocardial tissue is assumed to be incompressible, thick-walled, orthotropic and viscoelastic. In particular, one spring element coupled with Maxwell elements in parallel endows the model with viscoelastic features such that four dashpots describe the viscous response due to matrix, fiber, sheet and fiber-sheet fragments. In order to alleviate the numerical obstacles, the strictly incompressible model is altered by decomposing the free-energy function into volumetric-isochoric elastic and isochoric-viscoelastic parts along with the multiplicative split of the deformation gradient which enables the three-field mixed finite element method. The crucial aspect of the viscoelastic formulation is linked to the rate equations of the viscous overstresses resulting from a 3-D analogy of a generalized 1-D Maxwell model. We provide algorithmic updates for second Piola–Kirchhoff stress and elasticity tensors. In the sequel, we address some numerical aspects of the constitutive model by applying it to elastic, cyclic and relaxation test data obtained from biaxial extension and triaxial shear tests whereby we assess the fitting capacity of the model. With the tissue parameters identified, we conduct (elastic and viscoelastic) finite element simulations for an ellipsoidal geometry retrieved from a human specimen.  相似文献   

18.
We hypothesize that both compression and elongation stress–strain data should be considered for modeling and simulation of soft tissue indentation. Uniaxial stress–strain data were obtained from in vitro loading experiments of porcine liver tissue. An axisymmetric finite element model was used to simulate liver tissue indentation with tissue material represented by hyperelastic models. The material parameters were derived from uniaxial stress–strain data of compressions, elongations, and combined compression and elongation of porcine liver samples. in vitro indentation tests were used to validate the finite element simulation. Stress–strain data from the simulation with material parameters derived from the combined compression and elongation data match the experimental data best. This is due to its better ability in modeling 3D deformation since the behavior of biological soft tissue under indentation is affected by both its compressive and tensile characteristics. The combined logarithmic and polynomial model is somewhat better than the 5-constant Mooney–Rivlin model as the constitutive model for this indentation simulation.  相似文献   

19.
In this work, a finite element model intends to represent the effects that the passage of a fetal head can induce on the muscles of the pelvic floor, from a mechanical point of view.The finite element method is a valuable tool, that is contributing to the clarification of the mechanisms behind pelvic floor disorders related to vaginal deliveries, although some care is necessary in order to obtain correct results. The present work shows how the variation of the material parameters, used in the constitutive model, can affect the obtained results from a finite element simulation. The constitutive equation adopted in this work for the pelvic floor muscles is a modified form of the incompressible transversely isotropic hyperelastic model proposed earlier by Humphrey and Yin.Results for the pelvic floor strain and stresses obtained during the passage of the fetus head are presented. The results show the importance of the material parameters and the need for a correct constitutive model.  相似文献   

20.
The presented study details a combined experimental and computational method to assess and compare the mechanical behavior of the main body of 4 different stent graft designs. The mechanical response to a flat plate compression and radial crimping of the devices is derived and related to geometrical and material features of different stent designs. The finite element modeling procedure is used to complement the experimental results and conduct a solution sensitivity study. Finite element evaluations of the mechanical behavior match well with experimental findings and are used as a quantitative basis to discuss design characteristics of the different devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号