首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Beam damage is the main resolution-limiting factor when biological particles are observed by cryoelectron microscopy in a thin vitrified solution film. Furthermore, the low contrast of the specimen frequently makes observation difficult and limits the possibility of image processing. Cryo-negative staining, in which the particles are vitrified in a thin layer of concentrated ammonium molybdate solution, makes it possible to visualize the particles with a much better signal-to-noise ratio (SNR) while keeping the specimen in a good state of preservation. We have observed the Escherichia coli GroEL chaperonin, prepared in a native vitrified solution and by cryo-negative staining after electron exposure from 1000 to 3000e(-)/nm(2). We have compared the resulting three-dimensional models obtained from these different conditions and have tested their fit with the atomic model of the protein subunit obtained from X-ray crystallography. It is found that, down to 1.5-nm resolution, the particles appear to be faithfully represented in the cryo-negatively stained preparation, but there is an approximately 10-fold increase of SNR compared with the native vitrified preparation. Furthermore, for the same range of irradiation and down to the same resolution, the particles seem unaffected by beam damage, whereas the damage is severe in the native vitrified particles.  相似文献   

2.
The indirect secondary electron contrast (ISEC) condition of the scanning electron microscopy (SEM) produces high contrast detection with minimal damage of unstained biological samples mounted under a thin carbon film. The high contrast image is created by a secondary electron signal produced under the carbon film by a low acceleration voltage. Here, we show that ISEC condition is clearly able to detect unstained bacteriophage T4 under a thin carbon film (10-15 nm) by using high-resolution field emission (FE) SEM. The results show that FE-SEM provides higher resolution than thermionic emission SEM. Furthermore, we investigated the scattered electron area within the carbon film under ISEC conditions using Monte Carlo simulation. The simulations indicated that the image resolution difference is related to the scattering width in the carbon film and the electron beam spot size. Using ISEC conditions on unstained virus samples would produce low electronic damage, because the electron beam does not directly irradiate the sample. In addition to the routine analysis, this method can be utilized for structural analysis of various biological samples like viruses, bacteria, and protein complexes.  相似文献   

3.
Scanning electron microscopy (SEM) is an important tool for the nanometre-scale analysis of the various samples. Imaging of biological specimens can be difficult for two reasons: (1) Samples must often be left unstained to observe detail of the biological structures; however, lack of staining significantly decreases image contrast. (2) Samples are prone to serious radiation damage from electron beam. Herein we report a novel method for sample preparation involving placement on a new metal-coated insulator film. This method enables obtaining high-contrast images from unstained proteins and viruses by scanning electron microscopy with minimal electron radiation damage. These images are similar to those obtained by transmission electron microscopy. In addition, the method can be easily used to observe specimens of proteins, viruses and other organic samples by using SEM.  相似文献   

4.
Molecular architecture of bacteriophage T4   总被引:4,自引:0,他引:4  
In studying bacteriophage T4—one of the basic models of molecular biology for several decades—there has come a Renaissance, and this virus is now actively used as object of structural biology. The structures of six proteins of the phage particle have recently been determined at atomic resolution by X-ray crystallography. Three-dimensional reconstruction of the infection device—one of the most complex multiprotein components—has been developed on the basis of cryo-electron microscopy images. The further study of bacteriophage T4 structure will allow a better understanding of the regulation of protein folding, assembly of biological structures, and also mechanisms of functioning of the complex biological molecular machines.Translated from Biokhimiya, Vol. 69, No. 11, 2004, pp. 1463–1476.Original Russian Text Copyright © 2004 by Mesyanzhinov, Leiman, Kostyuchenko, Kurochkina, Miroshnikov, Sykilinda, Shneider.  相似文献   

5.
The development of cryo-focused ion beam (cryo-FIB) for the thinning of frozen-hydrated biological specimens enabled cryo-electron tomography (cryo-ET) analysis in unperturbed cells and tissues. However, the volume represented within a typical FIB lamella constitutes a small fraction of the biological specimen. Retaining low-abundance and dynamic subcellular structures or macromolecular assemblies within such limited volumes requires precise targeting of the FIB milling process. In this study, we present the development of a cryo-stage allowing for spinning-disk confocal light microscopy at cryogenic temperatures and describe the incorporation of the new hardware into existing workflows for cellular sample preparation by cryo-FIB. Introduction of fiducial markers and subsequent computation of three-dimensional coordinate transformations provide correlation between light microscopy and scanning electron microscopy/FIB. The correlative approach is employed to guide the FIB milling process of vitrified cellular samples and to capture specific structures, namely fluorescently labeled lipid droplets, in lamellas that are 300 nm thick. The correlation procedure is then applied to localize the fluorescently labeled structures in the transmission electron microscopy image of the lamella. This approach can be employed to navigate the acquisition of cryo-ET data within FIB-lamellas at specific locations, unambiguously identified by fluorescence microscopy.  相似文献   

6.
7.
The subsequent development and application of the negative staining technique to isolated virus particles and their components, following the early studies on the structure of T2 bacteriophage proteins, is described. The use of the method to prepare particles covering a wide range of different types of virus for examination in the electron microscope is reviewed, together with more recent advances in image analysis of electron micrographs obtained from negatively stained virus specimens.  相似文献   

8.
Gene 4 of bacteriophage T7 encodes a protein (gp4) that can translocate along single-stranded DNA, couple the unwinding of duplex DNA with the hydrolysis of dTTP, and catalyze the synthesis of short RNA oligoribonucleotides for use as primers by T7 DNA polymerase. Electron microscopic studies have shown that gp4 forms hexameric rings, and X-ray crystal structures of the gp4 helicase domain and of the highly homologous RNA polymerase domain of Escherichia coli DnaG have been determined. Earlier biochemical studies have shown that when single-stranded DNA is bound to the hexameric ring, the primase domain remains accessible to free DNA. Given these results, a model was suggested in which the primase active site in the gp4 hexamer is located on the outside of the hexameric ring. We have used electron microscopy and single-particle image analysis to examine T7 gp4, and have determined that the primase active site is located on the outside of the hexameric ring, and therefore provide direct structural support for this model.  相似文献   

9.
Sufficient fusion protein is present in single plaques produced by lytic, recombinant lambda bacteriophage to be detected by Coomassie blue staining following electrophoresis on sodium dodecyl sulfate-polyacrylamide gels. Agar plugs containing single plaques can be loaded directly onto the stacking gel thus avoiding the need for extensive sample preparation.  相似文献   

10.
Our knowledge of the organization of the cell is linked, to a great extent, to light and electron microscopy. Choosing either photons or electrons for imaging has many consequences on the image obtained, as well as on the experiment required in order to generate the image. One apparent effect on the experimental side is in the sample preparation, which can be quite elaborate for electron microscopy. In recent years, rapid freezing, cryo-preparation and cryo-electron microscopy have been more widely used because they introduce fewer artefacts during preparation when compared with chemical fixation and room temperature processing. In addition, cryo-electron microscopy allows the visualization of the hydrated specimens. In the present review, we give an introduction to the rapid freezing of biological samples and describe the preparation steps. We focus on bulk samples that are too big to be directly viewed under the electron microscope. Furthermore, we discuss the advantages and limitations of freeze substitution and cryo-electron microscopy of vitreous sections and compare their application to the study of bacteria and mammalian cells and to tomography.  相似文献   

11.
12.
13.
To progress the fields of tissue engineering (TE) and regenerative medicine, development of quantitative methods for non-invasive three dimensional characterization of engineered constructs (i.e. cells/tissue combined with scaffolds) becomes essential. In this study, we have defined the most optimal staining conditions for contrast-enhanced nanofocus computed tomography for three dimensional visualization and quantitative analysis of in vitro engineered neo-tissue (i.e. extracellular matrix containing cells) in perfusion bioreactor-developed Ti6Al4V constructs. A fractional factorial ‘design of experiments’ approach was used to elucidate the influence of the staining time and concentration of two contrast agents (Hexabrix and phosphotungstic acid) and the neo-tissue volume on the image contrast and dataset quality. Additionally, the neo-tissue shrinkage that was induced by phosphotungstic acid staining was quantified to determine the operating window within which this contrast agent can be accurately applied. For Hexabrix the staining concentration was the main parameter influencing image contrast and dataset quality. Using phosphotungstic acid the staining concentration had a significant influence on the image contrast while both staining concentration and neo-tissue volume had an influence on the dataset quality. The use of high concentrations of phosphotungstic acid did however introduce significant shrinkage of the neo-tissue indicating that, despite sub-optimal image contrast, low concentrations of this staining agent should be used to enable quantitative analysis. To conclude, design of experiments allowed us to define the most optimal staining conditions for contrast-enhanced nanofocus computed tomography to be used as a routine screening tool of neo-tissue formation in Ti6Al4V constructs, transforming it into a robust three dimensional quality control methodology.  相似文献   

14.
Amyloids share a common architecture but play disparate biological roles in processes ranging from bacterial defense mechanisms to protein misfolding diseases. Their structures are highly polymorphic, which makes them difficult to study by X-ray diffraction or NMR spectroscopy. Our understanding of amyloid structures is due in large part to recent advances in the field of cryo-EM, which allows for determining the polymorphs separately. In this review, we highlight the main stepping stones leading to the substantial number of high-resolution amyloid fibril structures known today as well as recent developments regarding automation and software in cryo-EM. We discuss that sample preparation should move closer to physiological conditions to understand how amyloid aggregation and disease are linked. We further highlight new approaches to address heterogeneity and polymorphism of amyloid fibrils in EM image processing and give an outlook to the upcoming challenges in researching the structural biology of amyloids.  相似文献   

15.
Bacteriophage T4 is a virus with well-known genetics, structure, and biology. Such techniques as X-ray crystallography, cryo-EM, and three-dimensional (3D) image reconstruction allowed describing its structure very precisely. The genome of this bacteriophage was completely sequenced, which opens the way for the use of many molecular techniques, such as site-specific mutagenesis, which was widely applied, e.g., in investigating the functions of some essential T4 proteins. The phage-display method, which is commonly applied in bacteriophage modifications, was successfully used to display antigens (PorA protein, VP2 protein of vvIBDV, and antigens of anthrax and HIV) on T4’s capsid platform. As first studies showed, the phage-display system as well as site-specific mutagenesis may also be used to modify interactions between phage particles and mammalian cells or to obtain phages infecting species other than the host bacteria. These may be used, among others, in the constantly developing bacteriophage therapy. All manipulations of this popular bacteriophage may enable the development of vaccine technology, phage therapy, and other branches of biological and medical science.  相似文献   

16.
Adhesion partitioning is a method for progressively dismantling small biological entities for observation of their internal structures. The method is particularly well suited to use with the electron microscope. Objects to be partitioned are air-dried between two preformed plastic films resulting in envelopment of the objects. On separating the films the objects are partitioned. Partitioned E. coli bacteria reveal a variety of structures which change markedly with culture age. Organisms from young cultures have a water-retaining gelatinous matrix in which radially striated discs, fabric-like structures, and microsomes are found. Older cultures are less anatomically complex. The T2 bacteriophage is shown to be composed of an outer limiting membrane and a cohesive semisolid fibrillar body substance, presumably nucleic acid, which can be drawn as a strand from the bacteriophage body.  相似文献   

17.
A Shapira  A Kohn 《Cryobiology》1974,11(5):452-464
The damage by freeze-drying to bacteriophage T4 was analysed in order to locate the site and the mechanism of damage. As a result of freeze-drying of bacteriophage T4, its head coat was damaged so as to lead to the loss of the DNA and emptying of the head. The tail assembly was generally undamaged and the freeze-dried phage preserved the biological activities concerned with absorption and injection (inhibition of host colony formation, inhibition of induction of beta-galactosidase, induction of changes in the potassium content in the host bacteria).The 2 mechanisms by which the freeze-drying damages the phage arc: osmotic shock, which occurs mainly during the resuspension of the FD phage, and the drying per se, i.e., the removal of water from the head protein.  相似文献   

18.
Intermediate filaments (IFs) assembled in vitro from recombinantly expressed proteins have a diameter of 8–12 nm and can reach several micrometers in length. IFs assemble from a soluble pool of subunits, tetramers in the case of vimentin. Upon salt addition, the subunits form first unit length filaments (ULFs) within seconds and then assembly proceeds further by end-to-end fusion of ULFs and short filaments. So far, IF subunits have mainly been observed by electron microscopy of glycerol sprayed and rotary metal shadowed specimens. Due to the shear forces during spraying the IF subunits appear generally as straight thin rods. In this study, we used atomic force microscopy (AFM), cryo-electron microscopy (cryo-EM) combined with molecular modeling to investigate the conformation of the subunits of vimentin, desmin and keratin K5/K14 IFs in various conditions. Due to their anisotropic shape the subunits are difficult to image at high resolution by cryo-EM. In order to enhance contrast we used a cryo-negative staining approach. The subunits were clearly identified as thin, slightly curved rods. However the staining agent also forced the subunits to aggregate into two-dimensional networks of dot-like structures. To test this conformational change further, we imaged dried unfixed subunits on mica by AFM revealing a mixture of extended and dot-like conformations. The use of divalent ions such as calcium and magnesium, as well as glutaraldehyde exposure favored compact conformations over elongated ones. These experimental results as well as coarse-grained molecular dynamics simulations of a vimentin tetramer highlight the plasticity of IF subunits.  相似文献   

19.
Adhesion partitioning is a method for progressively dismantling small biological entities for observation of their internal structures. The method is particularly well suited to use with the electron microscope. Objects to be partitioned are air-dried between two preformed plastic films resulting in envelopment of the objects. On separating the films the objects are partitioned. Partitioned E. coli bacteria reveal a variety of structures which change markedly with culture age. Organisms from young cultures have a water-retaining gelatinous matrix in which radially striated discs, fabric-like structures, and microsomes are found. Older cultures are less anatomically complex. The T2 bacteriophage is shown to be composed of an outer limiting membrane and a cohesive semisolid fibrillar body substance, presumably nucleic acid, which can be drawn as a strand from the bacteriophage body.  相似文献   

20.
The prolate icosahedral capsid geometry of wild type bacteriophage T4D has been determined by direct visualization of the triangular faces in stereoimages of transmission electron micrographs of phage particles. Bacteriophage T4 was prepared for transmission electron microscopy (TEM) following a protocol of freeze-fracturing, deep-etching (FDET) and replication by vertical deposition (80 degrees angle) of a thin platinum-carbon (Pt-C) metal layer of 1.01 nm. From direct statistical measurements of the ratio of the head length to width and of stereometric angles on T4 heads, we have estimated a Q number of 21. This confirms previous indirect studies on T4 and agrees with determinations on bacteriophage T2. Many of the structural features of T4 observed in FDET preparations differ significantly from those observed by classical negative staining methods for TEM imaging. Most important among the differences are the conformation of the baseplate (a closed rosebud) and the positioning of the tail fibers (retracted). The retracted position of the tail fibers in the FDET preparations has been confirmed by negatively staining phage previously fixed suspended in solution with 2% glutaraldehyde. The FDET protocols appear to reveal important structural features not seen in negative stained preparations. These have implications for bacteriophage T4 conformation in solution, viral assembly and phage conformation states prior to tail contraction and DNA ejection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号