首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
An analytical procedure has been developed for the simultaneous determination of ketobemidone and its N-demethylated metabolite, norketobemidone. After isolation from plasma and re-extraction to acidic aqueous phase, the two aminophenols were extracted as ions pairs with tetrabutylammonium to dichloromethane, where derivatization with ethyl chloroformate took place. Determination was performed by gas chromatography mass spectrometry with selected ion monitoring. Ketobemidone and norketobemidone could be detected in plasma in a concentration of 1 ng ml-1 and 3 ng ml-1, respectively. Determinations were performed down to 5 ng ml-1. The relative standard deviation of the method in the analysis of 10 ng ml-1 of ketobemidone and norketobemidone, respectively, was 8% and 9% (n=10). The absolute recovery of unconjugated ketobemidone and norketobemidone through the method at the 100 ng ml-1 level was 91% and 85%, respectively. The method was applied to the determination of ketobemidone and norketobemidone in plasma from patients given ketobemidone. The concentrations of unconjugated norketobemidone was too small to be detected.  相似文献   

2.
The fragrance compounds linalool (1) and linalyl acetate (2) could be detected, identified and quantified (1: 7-9 ng ml-1; and 2: 1-2 ng ml-1 and 4-5 ng ml-1 as free linalool) in blood samples after inhalation in animal experiments (mice) by gas chromatography/mass spectrometry (GC/MS) with chemical ionization (CI) (ammonia); selected ion monitoring (SIM) mode (1: m/z 81, 137 and 154; 2: 47, 57 and 137) and GC/flame ionization detection (FID). The inhalation of these monoterpenes in concentrations of 5 mg l-1 air leads to a significant reduction of the motility of the test animals down to 30-40% with respect to the control group.  相似文献   

3.
4.
A procedure is described for the extraction of diethylstilbestrol (DES) from animal tissue for quantitative capillary gas chromatography/mass spectrometry (GC/MS). The procedure is based upon use of a strong anion exchange polystyrene divinylbenzene resin for sample purification. The recovery of DES from the resin clean up was 88% in the high parts per trillion (ppt) range. Criteria for identification of DES using selected ion monitoring (SIM) GC/MS are presented. Liquid chromatography/mass spectrometry (LC/MS) was used to investigate altered DES cis/trans ratios observed in biological extracts.  相似文献   

5.
6.
Choi MH  Kim KR  Chung BC 《Steroids》2000,65(1):54-59
An efficient procedure is described for the simultaneous determination of 9 androgen glucuronides including androsterone, etiocholanolone, 11-ketoandrosterone, 11-ketoetiocholanolone, 11beta-hydroxyandrosterone, 11beta-hydroxyetiocholanolone, and dehydroepiandrosterone (DHEA) in 3-glucuronide form and dihydrotestosterone (DHT) and testosterone in 17-glucuronide form from urine specimens. The method involves solid-phase extraction of the urinary steroids using Serdolit PAD-1 resin, with subsequent conversion to methyl ester-trimethylsilyl (Me-TMS) ether derivatives for the direct analysis by gas chromatography-mass spectrometry (GC-MS) using high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. Upon split injection of Me-TMS steroids at 330 degrees C into the MXT-1 capillary column initially maintained at 300 degrees C then programmed to 322 degrees C at 2 degrees C/min, each androgen glucuronide was well separated in excellent peak shape. The characteristic ions at m/z 217 constituting the base peaks in the electron-impact (20 eV) mass spectra for most steroids permitted their sensitive detection by GC-MS with selected-ion monitoring (SIM), whereas base peak ion at m/z 271 was used for the SIM of dehydroepiandrosterone-3-glucuronide. The detection limits for SIM of most of the steroids were 15 pg except for the 3-glucuronides of 11-ketoandrosterone and 11-ketoetiocholanolone, which could be detected down to 20 pg. The SIM responses were linear with correlation coefficients varying from 0.981 to 0.993 in the concentration range of 20 to 3000 ng/ml for the androgens studied. When applied to urine samples, the present method allowed rapid screening for the 7 androgens in their glucuro-conjugated forms simultaneously with good overall precision and accuracy within the normal concentration ranges of 15.1 to 3124.6 ng/ml.  相似文献   

7.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for simultaneous quantitation of dexamethasone palmitate and dexamethasone in human plasma was developed. After sample preparation by protein precipitation and liquid-liquid extraction, the analytes and internal standard (IS) were separated on a Venusil XBP-C8 column using gradient elution. Multiple reaction monitoring of dexamethasone palmitate, dexamethasone and IS used the precursor to product ion transitions at m/z 631.8-->373.1, m/z 393.2-->147.1 and m/z 264.2-->58.1, respectively. The method was linear over the ranges 1.5-1000ng/mL for dexamethasone palmitate and 2.5-250ng/mL for dexamethasone with intra- and inter-day precisions of <10% and accuracies of 100+/-7%. The assay was applied to a clinical pharmacokinetic study involving the injection of dexamethasone palmitate to healthy volunteers.  相似文献   

8.
In the present study, we simultaneously measured several polyols, such as adonitol, arabitol, dulcitol, glucose, myo-inositol, mannitol, sorbitol, and xylitol, in urine by gas chromatography/mass spectrometry-positive chemical ionization. We also examined possible relationship between the levels of these metabolites and age in normal individuals. In order to proceed to its quantification by GC/MS, 200 microL of a urine sample were diluted with 3 ml of distilled water, lyophilized, acetylated, and then analyzed them. Using this method, we were able to quantify as little as 0.5-1.0 ng/microL, and we made the calibration curves to be linear from 0.25 to 250 ng/microL (r(2)>0.991). Analytical recoveries were over 89.4%, and the inter-day and intra-day variability for accuracy and reproducibility was less than 20%. In the normal urine sample, the levels of polyols were gender-differentiated and age-related. This simple GC/MS method is sensitive and allows the measurement of wide ranges of polyols using small amounts of urine. We conclude that the quantitation of urinary polyols using GC/MS appears to be a clinically useful method for assessing polyol-pathway activity.  相似文献   

9.
A radioimmunoassay for indole-3-acetic acid (IAA) has been validated by comparison with a physico-chemical assay utilizing gas chromatography-selected ion monitoring-mass spectrometry and 4,5,6,7-tetradeutero-indole-3-acetic acid as an internal standard. The radioimmunoassay provided a reliable estimate of the free IAA content of etiolated corn shoots. However, base hydrolysis of extracts for determination of ester IAA released substances which interfered with the radioimmunoassay. Interference was detected by internal controls and by lack of agreement with the mass spectral method. Interfering compounds could be removed from extracts by chromatography on diethylaminoethyl- and hydroxypropylated (lipophilic) Sephadex G-25. Following such purification the radioimmunoassay estimate of the total (free + ester) IAA content of etiolated corn shoots agreed with the mass spectral method within 2% on the average.  相似文献   

10.
A simple, rapid and sensitive method for determination of trichloroethylene (TCE) in rat blood, liver, lung, kidney and brain, using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS), is presented. A 100-microm polydimethylsiloxane (PDMS) fiber was selected for sampling. The major analytical parameters including extraction and desorption temperature, extraction and desorption time, salt addition, and sample preheating time were optimized for each of the biological matrices to enhance the extraction efficiency and sensitivity of the method. The lower limits of quantitation for TCE in blood and tissues were 0.25ng/ml and 0.75ng/g, respectively. The method showed good linearity over the range of 0.25-100ng TCE/ml in blood and 0.75-300ng TCE/g in tissues, with correlation coefficient (R(2)) values higher than 0.994. The precision and accuracy for intra-day and inter-day measurements were less than 10%. The relative recoveries of TCE respect to deionized water from all matrices were greater than 55%. Stability tests including autosampler temperature and freeze and thaw of specimens were also investigated. This validated method was successfully applied to study the toxicokinetics of TCE following administration of a low oral dose.  相似文献   

11.
12.
A new method, based upon a selective extraction and gas chromatographic/mass spectrometric analysis, was developed to monitor the effect of combined haemoperfusion-haemodialysis treatment in a case of propericiazine poisoning. The method relies on the selected ion monitoring of the acetate derivatives of propericiazine and its internal standard fluphenazine, after their extraction from 1 ml of alkalinized plasma with n-hexane:isopropanol (8:2, v/v), back-extraction into an acidified water phase, realkalinization and extraction with n-hexane: isopropanol, derivatization with acetic anhydride and gas chromatography on a short (12 m) OV-101 fused silica capillary column. The described procedure is specific and provides between-assay variability of 4.8% CV at 5 micrograms 1(-1) plasma concentration. The method enables quantification down to 1 microgram 1(-1) and hence demonstrates sufficient sensitivity to permit pharmacokinetic or drug monitoring studies.  相似文献   

13.
14.
Root segments of Pisum sativum L. were transformed by several strains of Agrobacterium rhizogenes. The resulting hairy roots, as well as apical segments from untransformed pea roots, were used to initiate root lines cultured in vitro. Levels of free IAA were quantified in the sub-cultured lines by gas-chromatography coupled to mass spectrometry, using selected ion monitoring. For most of the cultured untransformed and transformed root lines the IAA content was very small, compared with levels in untransformed intact primary roots. However, an agropine-type hairy root line (incited by strain 15834) contained significantly higher amounts of IAA. The peculiar phenotype of this root line (abundant production of calli) appears to be associated with an increased IAA level, as opposed to most of the hairy root lines, where the extensive secondary root proliferation associated with the hairy-root disease cannot be merely attributed to a markedly enhanced IAA content.  相似文献   

15.
Drake SJ  Morrison C  Smith F 《Chirality》2011,23(8):593-601
Methylamphetamine, ephedrine, and pseudoephedrine were derivatized using trifluoroacetic anhydride and enantiomers of each were analyzed using gas chromatography coupled to mass spectrometry (GC/MS) fitted with a γ‐cyclodextrin (Chiraldex™ G‐PN) chiral column. A temperature‐programmed method was developed and optimized and the results compared with those obtained using a previously published isothermal GC method applied to GC/MS analysis. Trifluoroacetylated 3‐(trifluoromethyl)phenethylamine hydrochloride was used as an internal standard, and mass fragmentation patterns are proposed for all derivatives analyzed. Qualitative validation of the optimized chromatographic conditions was completed in accordance with the guidelines published by the United Nations Office on Drugs and Crime (UNODC). Under conditions of repeatability and reproducibility, the method gave relative retention times with a relative standard deviation of less than 0.02% for all six analytes of interest. This surpasses the UNODC's acceptance criteria of 2% for validation of qualitative precision. Ephedrine and pseudoephedrine are common precursors in the clandestine manufacture of methylamphetamine. Seizures of illicit methylamphetamine therefore often contain mixtures of these optically active compounds. The simultaneous enantioseparation of these compounds to produce a profile would provide valuable information to law enforcement agencies regarding the provenance of a methylamphetamine seizure. Chirality, 2011. © 2011 Wiley‐Liss, Inc.  相似文献   

16.
17.
18.
For many research questions in modern molecular and systems biology, information about absolute protein quantities is imperative. This information includes, for example, kinetic modeling of processes, protein turnover determinations, stoichiometric investigations of protein complexes, or quantitative comparisons of different proteins within one sample or across samples. To date, the vast majority of proteomic studies are limited to providing relative quantitative comparisons of protein levels between limited numbers of samples. Here we describe and demonstrate the utility of a targeting MS technique for the estimation of absolute protein abundance in unlabeled and nonfractionated cell lysates. The method is based on selected reaction monitoring (SRM) mass spectrometry and the "best flyer" hypothesis, which assumes that the specific MS signal intensity of the most intense tryptic peptides per protein is approximately constant throughout a whole proteome. SRM-targeted best flyer peptides were selected for each protein from the peptide precursor ion signal intensities from directed MS data. The most intense transitions per peptide were selected from full MS/MS scans of crude synthetic analogs. We used Monte Carlo cross-validation to systematically investigate the accuracy of the technique as a function of the number of measured best flyer peptides and the number of SRM transitions per peptide. We found that a linear model based on the two most intense transitions of the three best flying peptides per proteins (TopPep3/TopTra2) generated optimal results with a cross-correlated mean fold error of 1.8 and a squared Pearson coefficient R(2) of 0.88. Applying the optimized model to lysates of the microbe Leptospira interrogans, we detected significant protein abundance changes of 39 target proteins upon antibiotic treatment, which correlate well with literature values. The described method is generally applicable and exploits the inherent performance advantages of SRM, such as high sensitivity, selectivity, reproducibility, and dynamic range, and estimates absolute protein concentrations of selected proteins at minimized costs.  相似文献   

19.
This study examines a novel sample preparation method for the determination of 11 hydroxy metabolites of polychlorinated biphenyls (PCBs) in plasma and organ tissues, followed by gas chromatography with mass spectrometric detection (GC/MS). The clean-up method was optimized to eliminate the interference matter by using a silica column and 10 mL of n-hexane/dichloromethane (4:6, v/v) as an eluent. Solid-phase and solvent extraction procedures were used for the plasma and tissues samples, respectively. Compared to C(18) and C(8) solid-phase, C(2) showed higher extraction efficiency with n-hexane as the eluent for plasma. The hydroxy-PCB extraction recoveries achieved with this combined extraction and clean-up procedure from plasma ranged from 87 to 117%, while those from tissues ranged from 82 to 111%. The linear detector responses for propyl derivatives of hydroxy-PCBs were obtained with the coefficients of determination varying from 0.992 to 0.998 in the concentration range of 0.1-20 ng mL(-1). The method detection limits ranged from 0.1 to 0.5 ng mL(-1) in 1 mL of plasma and from 0.1 to 0.5 ng g(-1) in 1g of tissues. This procedure was successfully applied to the study of 3-OH-2,3',4,4',5-PeCB in rat plasma and liver samples after intraperitoneal injection (20 mg/kg) of 2,3',4,4',5-PeCB.  相似文献   

20.
A detailed procedure for the assay of free pyrroloquinoline quinone (PQQ) in human and rat samples by gas chromatography/mass spectrometry (GC/MS) has been established with stable-isotopic PQQ as internal standard. PQQ was extracted from the samples, after addition of the internal standard, with butanol under acid conditions and with Sep-Pak C18 cartridges. After derivatization of PQQ with phenyltrimethylammonium hydroxide, molecular peaks at m/z 448 and 462 were used for detection of PQQ and [U-13C]PQQ by selected ion monitoring, respectively. Trace amounts of free PQQ were detected in eight organs, plasma and urine of the human, and in three organs of the rat. The PQQ level was highest in the human spleen (5.9 +/- 3.4 ng/g tissue, followed by the pancreas and lung, and it was below detection limits for human brain and heart. Trace levels of PQQ were also found in rat small intestine, liver and testis. Our data are far below those measured by the redox cycling method of Gallop's group for human plasma, adrenal and urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号