首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The selection of an adequate exposure assessment approach is imperative for the quality of epidemiological studies. The use of personal exposimeters turned out to be a reasonable approach to determine exposure profiles, however, certain limitations regarding the absolute values delivered by the devices have to be considered. Apart from the limited dynamic range, it has to be taken into account that these devices give only an approximation of the exposure due to the influence of the body of the person carrying the exposimeter, the receiver characteristics of the exposimeter, as well as the dependence of the measured value on frequency band, channel, slot configuration, and communication traffic. In this study, the relationship between the field strength measured close to the human body at the location of the exposimeter and the exposure, that is, the field strength at the location of the human body without the human body present, is investigated by numerical means using the Visible Human model as an anatomical phantom. Two different scenarios were chosen: (1) For FM, GSM, and UMTS an urban outdoor scenario was examined that included a transmitting antenna mounted on the roof of one of four buildings at a street crossing, (2) For WLAN an indoor scenario was investigated. For GSM the average degree of underestimation by the exposimeter (relation of the average field levels at the location of the exposimeter to the field level averaged over the volume of the human body without the body present) was 0.76, and for UMTS 0.87; for FM no underestimation was found, the ratio was 1. In the case of WLAN the degree of underestimation was more pronounced, the ratio was 0.64. This study clearly suggests that a careful evaluation of correction factors for different scenarios is needed prior to the definition of the study protocol. It has to be noted that the reference scenario used in this study does not allow for final conclusions on general correction factors. Bioelectromagnetics 31:535–545, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

2.
Exposimeters are increasingly applied in bioelectromagnetic research to determine personal radiofrequency electromagnetic field (RF‐EMF) exposure. The main advantages of exposimeter measurements are their convenient handling for study participants and the large amount of personal exposure data, which can be obtained for several RF‐EMF sources. However, the large proportion of measurements below the detection limit is a challenge for data analysis. With the robust ROS (regression on order statistics) method, summary statistics can be calculated by fitting an assumed distribution to the observed data. We used a preliminary sample of 109 weekly exposimeter measurements from the QUALIFEX study to compare summary statistics computed by robust ROS with a naïve approach, where values below the detection limit were replaced by the value of the detection limit. For the total RF‐EMF exposure, differences between the naïve approach and the robust ROS were moderate for the 90th percentile and the arithmetic mean. However, exposure contributions from minor RF‐EMF sources were considerably overestimated with the naïve approach. This results in an underestimation of the exposure range in the population, which may bias the evaluation of potential exposure‐response associations. We conclude from our analyses that summary statistics of exposimeter data calculated by robust ROS are more reliable and more informative than estimates based on a naïve approach. Nevertheless, estimates of source‐specific medians or even lower percentiles depend on the assumed data distribution and should be considered with caution. Bioelectromagnetics. Bioelectromagnetics 29:471–478, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

3.
We discuss initial magnetic field strength measurements made around radiofrequency (RF) induction heaters. These measurements were made with a monitor developed for the National Institute for Occupational Safety and Health (NIOSH) by the National Bureau of Standards (NBS). The monitor has a dynamic range of .01 to 10,000 A2/m2, a frequency range of 300 kHz to 100 MHz, an isotropic response (+/- .3 dB) with three mutally orthogonal loop antennas that have the ability to measure and display each of three orthogonal magnetic field components, a high probe burnout protection level of 20,000 A2/m2, and an accuracy of +/- 1.0 dB at 13 calibration frequencies. The portable survey monitor was used to measure the magnetic field strengths in the vicinity of 16 RF induction heaters. Typically these induction heaters are operated continuously for several hours. The maximum field strengths (without duty factor correction) ranged from 15 to 4,500 A2/m2 and were measured 5 to 51 cm from the loop applicators of the induction heaters. At locations commonly occupied by workers (ie, approximately 30 to 76 cm from heaters), the fields ranged from .01 to 300 A2/m2 (without duty factor correction).  相似文献   

4.
Human exposure to background radiofrequency electromagnetic fields (RF‐EMF) has been increasing with the introduction of new technologies. There is a definite need for the quantification of RF‐EMF exposure but a robust exposure assessment is not yet possible, mainly due to the lack of a fast and efficient measurement procedure. In this article, a new procedure is proposed for accurately mapping the exposure to base station radiation in an outdoor environment based on surrogate modeling and sequential design, an entirely new approach in the domain of dosimetry for human RF exposure. We tested our procedure in an urban area of about 0.04 km2 for Global System for Mobile Communications (GSM) technology at 900 MHz (GSM900) using a personal exposimeter. Fifty measurement locations were sufficient to obtain a coarse street exposure map, locating regions of high and low exposure; 70 measurement locations were sufficient to characterize the electric field distribution in the area and build an accurate predictive interpolation model. Hence, accurate GSM900 downlink outdoor exposure maps (for use in, e.g., governmental risk communication and epidemiological studies) are developed by combining the proven efficiency of sequential design with the speed of exposimeter measurements and their ease of handling. Bioelectromagnetics 34:300–311, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

5.
The interaction of body‐worn antennas with the human body causes a significant decrease in antenna efficiency and a shift in resonant frequency. A resonant slot in a small conductive box placed on the body has been shown to reduce these effects. The specific absorption rate is less than international health standards for most wearable antennas due to small transmitter power. This paper reports the linear relationship between power absorbed by biological tissues at different locations on the body and radiation efficiency based on numerical modeling (r = 0.99). While the ?10 dB bandwidth of the antenna remained constant and equal to 12.5%, the maximum frequency shift occurred when the antenna was close to the elbow (6.61%) and on the thigh (5.86%). The smallest change was found on the torso (4.21%). Participants with body‐mass index (BMI) between 17 and 29 kg/m2 took part in experimental measurements, where the maximum frequency shift was 2.51%. Measurements showed better agreement with simulations on the upper arm. These experimental results demonstrate that the BMI for each individual had little effect on the performance of the antenna. Bioelectromagnetics. 39:25–34, 2018. © 2017 Wiley Periodicals, Inc.  相似文献   

6.
7.
The three‐dimensional distribution of the specific absorption rate of energy (SAR) in phantom models was analysed to detect clusters of mobile phones producing similar spatial deposition of energy in the head. The clusters' characteristics were described from the phones external features, frequency band and communication protocol. Compliance measurements with phones in cheek and tilt positions, and on the left and right side of a physical phantom were used. Phones used the Personal Digital Cellular (PDC), Code division multiple access One (CdmaOne), Global System for Mobile Communications (GSM) and Nordic Mobile Telephony (NMT) communication systems, in the 800, 900, 1500 and 1800 MHz bands. Each phone's measurements were summarised by the half‐ellipsoid in which the SAR values were above half the maximum value. Cluster analysis used the Partitioning Around Medoids algorithm. The dissimilarity measure was based on the overlap of the ellipsoids, and the Manhattan distance was used for robustness analysis. Within the 800 MHz frequency band, and in part within the 900 MHz and the 1800 MHz frequency bands, weak clustering was obtained for the handset shape (bar phone, flip with top and flip with central antennas), but only in specific positions (tilt or cheek). On measurements of 120 phones, the three‐dimensional distribution of SAR in phantom models did not appear to be related to particular external phone characteristics or measurement characteristics, which could be used for refining the assessment of exposure to radiofrequency energy within the brain in epidemiological studies such as the Interphone. Bioelectromagnetics. Bioelectromagnetics 32:634–643, 2011. © 2011 Wiley Periodicals, Inc.  相似文献   

8.
Personal exposure meters (PEM) are routinely used for the exposure assessment to radio frequency electric or magnetic fields. However, their readings are subject to errors associated with perturbations of the fields caused by the presence of the human body. This paper presents a novel analysis method for the characterization of this effect. Using ray‐tracing techniques, PEM measurements have been emulated, with and without an approximation of this shadowing effect. In particular, the Global System for Mobile Communication mobile phone frequency band was chosen for its ubiquity and, specifically, we considered the case where the subject is walking outdoors in a relatively open area. These simulations have been contrasted with real PEM measurements in a 35‐min walk. Results show a good agreement in terms of root mean square error and E‐field cumulative distribution function (CDF), with a significant improvement when the shadowing effect is taken into account. In particular, the Kolmogorov–Smirnov (KS) test provides a P‐value of 0.05 when considering the shadowing effect, versus a P‐value of 10−14 when this effect is ignored. In addition, although the E‐field levels in the absence of a human body have been found to follow a Nakagami distribution, a lognormal distribution fits the statistics of the PEM values better than the Nakagami distribution. As a conclusion, although the mean could be adjusted by using correction factors, there are also other changes in the CDF that require particular attention due to the shadowing effect because they might lead to a systematic error. Bioelectromagnetics 32:209–217, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

9.
This study investigates occupational exposure to electromagnetic fields in front of a multi‐band base station antenna for mobile communications at 900, 1800, and 2100 MHz. Finite‐difference time‐domain method was used to first validate the antenna model against measurement results published in the literature and then investigate the specific absorption rate (SAR) in two heterogeneous, anatomically correct human models (Virtual Family male and female) at distances from 10 to 1000 mm. Special attention was given to simultaneous exposure to fields of three different frequencies, their interaction and the additivity of SAR resulting from each frequency. The results show that the highest frequency—2100 MHz—results in the highest spatial‐peak SAR averaged over 10 g of tissue, while the whole‐body SAR is similar at all three frequencies. At distances >200 mm from the antenna, the whole‐body SAR is a more limiting factor for compliance to exposure guidelines, while at shorter distances the spatial‐peak SAR may be more limiting. For the evaluation of combined exposure, a simple summation of spatial‐peak SAR maxima at each frequency gives a good estimation for combined exposure, which was also found to depend on the distribution of transmitting power between the different frequency bands. Bioelectromagnetics 32:234–242, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

10.
In this article, the general public daily exposure to broadcast signals and Global System for Mobile Communications (GSM) or Universal Mobile Telecommunications System (UMTS) mobile telephone signals in indoor areas is investigated. Temporal variations and traffic distributions during a day at different indoor sites in urban and rural zones are presented. The goal is to analyze the real exposure compared to the maximum assessment imposed by radio protection standards and to characterize the ratio between daily and maximum theoretical values. Hence, a realistic maximum is proposed based on the statistical analysis performed using measurements. Broadcast signals remain constant over the day so they are best fitted with a Normal distribution while the mobile telephone signals depend on the traffic demand during the day so they fit a three‐Gaussian distribution model. A general mask is also constructed for underlining the maximum equivalent active traffic for different periods in the day. Also, relations between the mean values over 24 h, the realistic maximal values (at 99%) and the maximal theoretical values are presented. The realistic maximum is also presented with a sliding time average of 6 min applied to the measurements in accordance with international standards. An extrapolation factor is given for the different systems to easily assess the maximum values starting from an instantaneous measurement. The extrapolation factor is also given for a broadband measurement to estimate the maximum potential exposure during the day. Bioelectromagnetics 33:288–297, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

11.
We investigated whether domestic and professional induction cooktops comply with the basic restrictions defined by the International Commission on Non‐Ionizing Radiation Protection (ICNIRP). Based on magnetic field measurements, a generic numerical model of an induction cooktop was derived in order to model user exposure. The current density induced in the user was simulated for various models and distances. We also determined the exposure of the fetus and of young children. While most measured cooktops comply with the public exposure limits at the distance specified by the International Electrotechnical Commission (standard IEC 62233), the majority exceeds them at closer distances, some of them even the occupational limits. The maximum current density in the tissue of the user significantly exceeds the basic restrictions for the general public, reaching the occupational level. The exposure of the brains of young children reaches the order of magnitude of the limits for the general public. For a generic worst‐case cooktop compliant with the measurement standards, the current density exceeds the 1998 ICNIRP basic restrictions by up to 24 dB or a factor of 16. The brain tissue of young children can be overexposed by 6 dB or a factor of 2. The exposure of the tissue of the central nervous system of the fetus can exceed the limits for the general public if the mother is exposed at occupational levels. This demonstrates that the methodology for testing induction cooktops according to IEC 62233 contradicts the basic restrictions. This evaluation will be extended considering the redefined basic restrictions proposed by the ICNIRP in 2010. Bioelectromagnetics 33:695–705, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

12.
Currently in the literature there is no consensus on which procedure for normalizing seated spine kinematics is most effective. The objective of this study was to examine the changes in the range of motion (ROM) of seated posture trials when expressed as a percent of maximum standing and seated ROM. A secondary purpose was to determine whether the typical maximum planar calibration movements (flexion, lateral-bend, and axial twist) elicited the respective maximum ROM values for each spine region versus postures with specific movement instruction. Thirteen male participants completed seven different movement trials. These consisted of the maximum planar movement trials, with the remaining four postures being combinations of specific lumbar and thoracic movements. Global and relative angles for the upper-thoracic, mid-thoracic, lower-thoracic, and lumbar regions were calculated and normalized to both a seated and standing reference posture. When normalizing both global and relative angles the standing reference appears optimal for flexion, twisting and lateral bend angles in all spine regions, with the exception of relative flexion angle in the mid-thoracic region. The maximum planar movement trials captured the greatest ROM for each global angle, relative lower-thoracic angle and relative lumbar flexion angle, but did not for all other relative angles in the upper-thoracic, mid-thoracic, and lumbar regions. If future researchers can only collect one reference posture these results recommend that a standing reference posture be collected for normalizing seated spine kinematics, although a seated reference posture should be collected if examining relative flexion angles at the mid-thoracic region.  相似文献   

13.
Human exposure to electromagnetic fields produced by two wearable antennas operating in the 2.4 GHz frequency band was assessed by computational tools. Both antennas were designed to be attached to the skin, but they were intended for different applications. The first antenna was designed for off-body applications, i.e. to communicate with a device placed outside the body, while the second antenna model was optimized to communicate with a device located inside the body. The power absorption in human tissues was determined at several locations of adult male and female body models. The maximum specific absorption rate (SAR) value obtained with the off-body antenna was found on the torso of the woman model and was equal to 0.037 W/kg at 2.45 GHz. SAR levels increased significantly for the antenna transmitting inside the body. In this case, SAR values ranged between 0.23 and 0.45 W/kg at the same body location. The power absorbed in different body tissues and total power absorbed in the body were also calculated; the maximum total power absorbed was equal to 5.2 mW for an antenna input power equal to 10 mW. Bioelectromagnetics. 2020;41:73–79 © 2019 Wiley Periodicals, Inc.  相似文献   

14.
The reason for using acupuncture points as exposure sites in some applications of millimeter wave therapy has been unclear. Acupuncture points have been suspected to exhibit particular direct current (DC), low‐frequency electrical and optical properties compared to surrounding skin. To assess if such a biophysical correlation could exist at millimeter wave frequencies used in the therapy, we investigated the dielectric properties of an acupuncture point on the forearm skin within the 50–75 GHz range. These properties were compared with those of a neighboring ipsilateral control area and a corresponding contralateral control area. The complex reflection coefficient at the end of an open‐ended rectangular waveguide loaded with a Teflon plug was measured with a vector network analyzer. A suitable model of the aperture admittance was used to calculate the dielectric properties of the skin at the measured spots. Statistical analyses were conducted with an ANOVA to compare the three sites. From these analyses, the dielectric properties of the acupuncture site were found to be somewhat different from those of surrounding non‐acupuncture sites from 50 to about 61 GHz, in the case of the real part of the complex permittivity. Bioelectromagnetics 32:360–366, 2011. © 2011 Wiley‐Liss, Inc.  相似文献   

15.
This article is the presentation I gave at the D'Arsonval Award Ceremony on June 14, 2011 at the Bioelectromagnetics Society Annual Meeting in Halifax, Nova Scotia. It summarizes my research activities in acoustic and electromagnetic millimeter waves over the past 47 years. My earliest research involved acoustic millimeter waves, with a special interest in diagnostic ultrasound imaging and its safety. For the last 21 years my research expanded to include electromagnetic millimeter waves, with a special interest in the mechanisms underlying millimeter wave therapy. Millimeter wave therapy has been widely used in the former Soviet Union with great reported success for many diseases, but is virtually unknown to Western physicians. I and the very capable members of my laboratory were able to demonstrate that the local exposure of skin to low intensity millimeter waves caused the release of endogenous opioids, and the transport of these agents by blood flow to all parts of the body resulted in pain relief and other beneficial effects. Bioelectromagnetics 34:3–14, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
In the present experiment, the effect of a single 30 min inhomogeneous static magnetic field (SMF) exposure on thermal pain threshold (TPT) was examined in 15 young healthy human volunteers. The SMF had a maximum peak‐to‐peak amplitude of 330 mT with a maximum gradient of 13.2 T/m. In either of two experimental sessions (SMF or SHAM), four blocks of 12 TPT trials were carried out under SMF or SHAM exposure on all fingertips of the dominant hand, excluding the thumb. TPT and visual analog scale (VAS) data were recorded at 0, 15, and 30 min exposure time, and 30 min following exposure. SMF treatment resulted in a statistically significant increase in TPT during the entire exposure duration and diminished within‐block thermal habituation, leaving pain perception unchanged. These results indicate that SMF‐induced peripheral neuronal or circulatory mechanisms may be involved in the observed TPT increase by setting the pain fibre adaptation potential to higher levels. Bioelectromagnetics 32:131–139, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

17.
The development of scientifically sound instrumentation, methods, and procedures for the electromagnetic exposure assessment of compact fluorescent lamps (CFLs) is investigated. The incident and induced fields from 11 CFLs have been measured in the 10 kHz–1 MHz range, and they are compared with the levels for incandescent and light emitting diode (LED) bulbs. Commercially available equipment was used to measure the incident fields, while a novel sensor was built to assess the induced fields in humans. Incident electric field levels significantly exceed the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) reference levels at close distances for some sources, while the induced fields are within the ICNIRP basic restrictions. This demonstrates the importance of assessing the induced fields rather than the incident fields for these sources. Maximum current densities for CFLs are comparable to the limits (in the range of 9% to 56%), demonstrating the need for measurements to establish compliance. For the frequency range investigated, the induced fields were found to be considerably higher for CFLs than for incandescent light bulbs, while the exposure from the two LED bulbs was low. The proposed instrumentation and methods offer several advantages over an existing measurement standard, and the measurement uncertainty is significantly better than the assessment of electric and magnetic fields at close distances. Bioelectromagnetics 33:166–175, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

18.
Exposure to external extremely low-frequency (ELF) electric and magnetic fields induces the development of electric fields inside the human body, with their nature depending on multiple factors including the human body characteristics and frequency, amplitude, and wave shape of the field. The objective of this study was to determine whether active implanted cardiac devices may be perturbed by a 50 or 60 Hz electric field and at which level. A numerical method was used to design the experimental setup. Several configurations including disadvantageous scenarios, 11 implantable cardioverter-defibrillators, and 43 cardiac pacemakers were tested in vitro by an experimental bench test up to 100 kV/m at 50 Hz and 83 kV/m at 60 Hz. No failure was observed for ICNIRP public exposure levels for most configurations (in more than 99% of the clinical cases), except for six pacemakers tested in unipolar mode with maximum sensitivity and atrial sensing. The implants configured with a nominal sensitivity in the bipolar mode were found to be resistant to electric fields exceeding the low action levels, even for the highest action levels, as defined by the Directive 2013/35/EU. Bioelectromagnetics. 2020;41:136–147. © 2020 Bioelectromagnetics Society.  相似文献   

19.
This paper proposes a novel in vitro exposure system operating at millimeter‐wave (mmWave) 28 GHz, one of the frequency bands under consideration for fifth generation (5G) communication. We employed the field uniformity concept along cross‐sectional observation planes at shorter distances from the radiation antenna for better efficiency and a small‐size system. A choke‐ring antenna was designed for this purpose in consideration of a wider beamwidth (BW) and a symmetric far‐field pattern across three principal planes. The permittivity of Dulbecco's modified Eagle's medium solution was measured to examine the specific absorption rate (SAR) of the skin cell layer inside a Petri dish model for a three‐dimensional (3D) cell culture in vitro experiment. The best deployment of Petri dishes, taking into account a geometrical field symmetry, was proposed. Local SAR values within the cell layer among the Petri dishes were determined with different polarization angles. It was determined that this polarization effect should be considered when the actual exposure and deployment were conducted. We finally proposed an in vitro exposure system based on the field uniformity including downward exposure from an antenna for 3D cell culture experiments. A small‐size chamber system was obtained, and the size was estimated using the planar near‐field chamber design rule. Bioelectromagnetics. 2019;40:445–457. © 2019 Bioelectromagnetics Society  相似文献   

20.
In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm × 500 mm × 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole‐body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole‐body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole‐body average SAR, if the distance to the antenna was less than 240 mm. Bioelectromagnetics 30:307–312, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号