首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The transient elastohydrodynamic lubrication (EHL) analysis was performed in this study for a typical metal-on-metal bearing employing a polyethylene backing underneath a metallic cup inlay under dynamic operating conditions of load and speed representative of normal walking. A ball-in-socket configuration was adopted to represent the articulation between the femoral head and the acetabular cup. The governing Reynolds and elasticity equations were solved simultaneously by using both finite difference and finite element methods. The predicted transient film thickness from the present study was compared with the estimation based on the quasi-static analysis. It was found that the polyethylene backing employed in the typical metal-on-metal hip bearing, combined with dynamic squeeze-film action, significantly improved the transient lubricant film thickness under cyclic walking and consequently a fluid film lubrication regime was possible for smooth bearing surfaces with an average roughness less than 0.005 microm.  相似文献   

2.
Prediction of lubricating film thickness in UHMWPE hip joint replacements   总被引:4,自引:0,他引:4  
An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.  相似文献   

3.
Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface.  相似文献   

4.
An effective lubrication can significantly reduce wear of metal-on-metal artificial hip joints. The improvement of the lubrication can be achieved through the optimisation of the bearing geometry in terms of a small clearance and/or the structural support such as a polyethylene backing underneath a metallic bearing in a sandwich acetabular cup form. The separate effects of these two factors on fluid film lubrication of 28 mm diameter metal-on-metal total hip joints under walking conditions were numerically investigated in this paper. The results show that a larger lubricant film due to the polyethylene backing can be significantly enhanced by the transient squeeze-film action, particularly during the stance phase, and a similar lubricant film can be developed for both the monolithic cup relying on the smaller clearance and the sandwich cup benefiting from the polyethylene backing. Both cup systems can function in a wide range of lubrication regimes, covering both mixed and fluid film, under the current design and manufacture conditions.  相似文献   

5.
Formulation of a 3-D lubrication simulation of a total hip replacement in vivo is presented using a finite difference approach. The goal is to determine if hydrodynamic lubrication is taking place, how thick the joint fluid film is and over what percentage of two gait cycles, (walking and bicycling), the hydrodynamic lubricating action is occurring, if at all. The assumption of rigid surfaces is made, which is conservative in the sense that pure hydrodynamic lubrication is well known to predict thinner films than elasto-hydrodynamic lubrication (EHL) for the same loading. The simulation method includes addressing the angular velocity direction changes and accurate geometry configuration for the acetabular cup and femoral head components and provides a range of results for material combinations of CoCrMo-on-UHMWPE, CoCrMo-on-CoCrMo, and alumina-on-alumina components. Results are in the form of the joint fluid film pressure distributions, load components and film thicknesses of the joint fluid, for the gait cycles of walking and bicycling. Results show hydrodynamic action occurs in only about 10% of a walking gait cycle and throughout nearly 90% of a bicycling gait. During the 10% of the walking cycle that develops hydrodynamic lubrication, the minimum fluid film thicknesses are determined to be between 0.05 micron and 1.1 microns, while the range of film thicknesses for bicycling is between 0.1 micron and 1.4 microns, and occurs over 90% of the bicycling gait. Pressure distributions for these same periods are in the range of 2 MPa to 870 MPa for walking and 1 MPa to 24 MPa for bicycling.  相似文献   

6.
Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and implant loosening. This study was designed to determine the effects of ball radius on friction. Generic models of metal-on-metal TDA were manufactured with ball radii of 10, 12, 14 and 16 mm, with a radial clearance of 0.015 mm. A simulator was used to test each sample in flexion-extension, lateral bending and axial rotation at frequencies of 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75 and 2 Hz under loads of 50, 600, 1200 and 2000 N, in new born calf serum. Frictional torque was measured and Stribeck curves were plotted to illustrate the lubrication regime in each case. It was observed that implants with a smaller ball radius showed lower friction and showed boundary and mixed lubrication regimes, whereas implants with larger ball radius showed boundary lubrication only. This study suggests designing metal-on-metal TDAs with ball radius of 10 or 12 mm, in order to reduce wear and implant loosening.  相似文献   

7.
The wrist joint is frequently affected by rheumatoid arthritis, resulting in wrist pain, deformity and ultimately loss of function. Artificial wrist implants have been introduced to treat the rheumatoid wrist, to attempt to alleviate pain and restore some function to the joint. The aim of this study was to predict the likely lubrication regimes that occur in wrist implants with spherical bearing surfaces. The implant was modelled as an equivalent ball-on-plane. Elastohydrodynamic lubrication theory was used to determine the minimum film thickness for the implant under different load, entraining velocity, lubricant viscosity, size of implant and material combinations. The results show that the highest film thickness is found in large implants, with high viscosity, high entraining velocity and low load. Hard-on-soft material combinations will operate with a boundary lubrication regime. Material combinations involving ceramic bearing surfaces have the potential to operate with a mixed lubrication regime.  相似文献   

8.
As one of the alternatives to traditional metal-on-polyethylene total hip replacements, metal-on-metal hip resurfacing prostheses demonstrating lower wear have been introduced for younger and more active patients during the past decade. However, in vitro hip simulator testing for the predicted increased lifetime of these surface replacements is time-consuming and costly. Computational wear modelling based on the Archard wear equation and finite element contact analysis was developed in this study for artificial hip joints and particularly applied to metal-on-metal resurfacing bearings under simulator testing conditions to address this issue. Wear factors associated with the Archard wear equation were experimentally determined and based on the short-term hip simulator wear results. The computational wear simulation was further extended to a long-term evaluation up to 50 million cycles assuming that the wear rate stays constant. The prediction from the computational model shows good agreement with the corresponding simulator study in terms of volumetric wear and the wear geometry. The simulation shows the progression of linear wear penetrations, and the complexity of contact stress distribution on the worn bearing surfaces. After 50 million cycles, the maximum linear wear was predicted to be approximately 6 and 8 microm for the cup and head, respectively, and no edge contact was found.  相似文献   

9.
<正> Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces.  相似文献   

10.
A new finite element model (FEM) based on an elasto-plastic behavior of ultra high molecular weight polyethylene (UHMWPE) was used to study the wear behavior of UHMWPE acetabular cup, which has a 32 mm diameter femoral head. The model imposed a plastic yield stress of 8 MPa on the UHMWPE so that any stresses beyond this would automatically be redistributed to its neighbor. The FEM model adopted a unique mesh design based on an open cube concept which eliminated the problems of singularities. Wear prediction combined the influences of contact stress, sliding distance and a surface wear coefficient. The new model predicted significantly higher volumetric wear rate (57 mm(3)/yr) well within the average reported clinical values. The model was also used to study the effect of friction and clearance between the acetabular cup and the femoral head. Increase in friction increased the volumetric wear rate but did not appear to affect the linear wear rate, which remained at 0.12 +/- 0.02 mm/yr. The predicted wear was sensitive to clearance. It was found that when the clearance was close to 0 and >0.5mm, severe wear occurred. The best clearance range was between 0.1 and 0.15 mm where the average linear wear rate was 0.1mm/yr and the volumetric wear was 55 mm(3)/yr. The present work indicates the importance of avoiding too tight or too loose a diametrical clearance.  相似文献   

11.
The tibial component of current knee prostheses made of ultra high molecular weight polyethylene (UHMWPE) has a high degree of wear that causes knee inflammation, prosthesis loosening and subsequent replacement in not more than 15 years. In order to know which UHMWPE material properties have more influence on wear, a steady state lubrication model with non-Newtonian synovial fluid has been studied through numerical solution. The results show that UHMWPE has a very high elastic modulus that makes difficult a well lubricated artificial joint and induces the formation of very thin lubricating films between the moving surfaces with the same magnitude of roughness components. This study shows that the use of deformable porous materials in the tibial component could cause the lubricating film thickness to be higher than the average roughness and the pressure levels to be lower than the one predicted for UHMWPE. These two facts imply friction and wear reduction.  相似文献   

12.
Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to experimentally validate FE methodology for modelling hemiarthroplasty. Material properties such as equilibrium elastic modulus and permeability of porcine acetabular cartilage were initially derived by curve-fitting an experimental deformation curve with that obtained using FE. These properties were then used in the hemiarthroplasty hip joint modelling. Each porcine acetabular cup was loaded with 400N using a 34mm diameter CoCr femoral head. A specimen-specific FE model of each acetabular cup was created using μCT and a series of software processes. Each model was analysed under conditions similar to those tested experimentally. Contact stresses and contact areas predicted by the model, immediately after loading, were then compared with the corresponding experimentally measured values. Very high peak contact stresses (maximum experimental: 14.09MPa) were recorded. A maximum difference of 12.42% was found in peak contact stresses. The corresponding error for contact area was 20.69%. Due to a fairly good agreement in predicted and measured values of contact stresses and contact areas, the integrated methodology developed in this study can be used as a basis for future work. In addition, FE predicted total fluid load support was around 80% immediately after loading. This was lower than that observed in conforming contact problems involving biphasic cartilage and was due to a smaller local contact area and variable clearance making fluid exudation easier.  相似文献   

13.
M Hlavácek 《Biorheology》2001,38(4):319-334
The thixotropic (shear-thinning) effect of the synovial fluid in squeeze-film lubrication of the human hip joint is evaluated, taking into account filtration of the squeezed synovial film by biphasic articular cartilage. A porous, homogeneous, elastic cartilage matrix filled with the interstitial ideal fluid, with the intact superficial zone (of lower permeability and stiffness in compression) already disrupted or worn away, models an early stage of arthritis. Due to a high viscosity of the normal synovial fluid at very low shear rates, the squeezed synovial film at a fixed time after the application of a steady load is found to be much thicker in a small central part of the lubricated contact area. In the remaining part, the film is thin as it corresponds to the Newtonian fluid with the same high-shear-rate viscosity. Filtration is lower for the normal cartilage with the intact superficial zone due to its lower permeability and compression stiffness. But even in the fictitious case of zero filtration, calculations show that the effect of thixotropy on the increase of the minimum synovial film thickness would manifest itself as late as after several tens of seconds since the physiologic load application. At that time, this thickness would be as low as about 0.3 microm. It follows that thixotropy of the normal synovial fluid (and so much more of the inflammatory fluid) is irrelevant in squeeze-film lubrication of both the normal and arthritic human hip joints.  相似文献   

14.
This work is concerned with the lubrication analysis of artificial knee joints, which plays an increasing significant role in clinical performance and longevity of components. Time-dependent elastohydrodynamic lubrication analysis for normal total knee replacement is carried out under the cyclic variation in both load and speed representative of normal walking. An equivalent ellipsoid-on-plane model is adopted to represent an actual artificial knee. A full numerical method is developed to simultaneously solve the Reynolds and elasticity equations using the multigrid technique. The elastic deformation is based on the constrained column model. Results show that, under the combined effect of entraining and squeeze-film actions throughout the walking cycle, the predicted central film thickness tends to decrease in the stance phase but keeps a relatively larger value at the swing phase. Furthermore, the geometry of knee joint implant is verified to play an important role under its lubrication condition, and the length of time period is a key point to influence the lubrication performance of joint components.  相似文献   

15.
This work is concerned with the lubrication analysis of artificial knee joints, which plays an increasing significant role in clinical performance and longevity of components. Time-dependent elastohydrodynamic lubrication analysis for normal total knee replacement is carried out under the cyclic variation in both load and speed representative of normal walking. An equivalent ellipsoid-on-plane model is adopted to represent an actual artificial knee. A full numerical method is developed to simultaneously solve the Reynolds and elasticity equations using the multigrid technique. The elastic deformation is based on the constrained column model. Results show that, under the combined effect of entraining and squeeze-film actions throughout the walking cycle, the predicted central film thickness tends to decrease in the stance phase but keeps a relatively larger value at the swing phase. Furthermore, the geometry of knee joint implant is verified to play an important role under its lubrication condition, and the length of time period is a key point to influence the lubrication performance of joint components.  相似文献   

16.
There is renewed interest in metal-on-metal (MOM) total hip replacements (THRs), however, variable wear rates have been observed clinically. It is hypothesised that changes in soft tissue tensioning during surgery may alter loading of THRs during the swing phase of gait leading to changes in fluid film lubrication, friction and wear. This study aimed to assess the effect of swing phase load on the lubrication, friction and wear of MOM hip replacements. Theoretical lubrication modelling was carried out using elastohydrodynamic theory. All the governing equations were solved numerically for the lubricant film thickness between the articulating surfaces under the transient dynamic conditions with low and high swing phase loads. Friction testing was completed using a single axis pendulum simulator, simplified loading cycles were applied with low and high swing phase loads. MOM hip replacements were tested in a hip simulator, modified to provide different swing phase loading regimes; a low (100 N) and a high load (as per ISO 14242-1; 280 N). Results demonstrated that the performance of MOM bearings is highly dependent on swing phase load. Hence, changes in the tension of the tissues at surgery and variations in muscle forces may increase swing phase load, reduce lubrication, increase friction and accelerate wear. This may explain some of the variations that have been observed with clinical wear rates.  相似文献   

17.
Surface damage in polyethylene components for total joint replacement is associated with large contact stresses. An elasticity solution and finite element analyses were used to determine the influence of design parameters on the stresses due to contact in metal-backed components. For nearly conforming contact surfaces, it was found that the stresses in the plastic are very sensitive to clearance, that minimum plastic thickness of 4-6 mm should be maintained for metal-backed components, and that bonding the plastic to the metal backing reduces tensile stresses in the plastic at the edge of the contact zone.  相似文献   

18.

Introduction

Treatment of femoral neck fractures in young adults may require total hip arthroplasty or hip hemiarthroplasty using a bipolar cup. The latter can, however, result in migration of the femoral head and poor long-term results.

Case presentation

We report a case of femoral head migration after hemiarthroplasty performed for femoral neck fracture that had occurred 22 years earlier, when the patient (a Japanese man) was 20 years old. He experienced peri-prosthetic fracture of the femur, subsequent migration of the prosthesis, and a massive bone defect of the pelvic side acetabular roof. After bone union of the femoral shaft fracture, the patient was referred to our hospital for reconstruction of the acetabular roof. Intra-operatively, we placed two alloimplants of bone from around the transplanted femoral head into the weight-bearing region of the acetabular roof using an impaction bone graft method. We then implanted an acetabular roof reinforcement plate and a cemented polyethylene cup in the position of the original acetabular cup. Eighteen months post-operatively, X-rays showed union of the transplanted bone.

Conclusions

Treatment of femoral neck fractures in young adults is usually accomplished by osteosynthesis, but it may be complicated by femoral head avascular necrosis or by infection or osteomyelitis. In such cases, once an infection has subsided, either hip hemiarthroplasty using a bipolar cup or total hip arthroplasty may be required. However, if the acetabular side articular cartilage is damaged, a bipolar cup should not be used. Total hip arthroplasty should be performed to prevent migration of the implant.  相似文献   

19.
The authors present an experimental study of the rabbit femoral prosthesis compatibility : macroscopical aspect, proteoglycan content and metabolism of the acetabular cartilage.  相似文献   

20.
Late loosening of cemented acetabular cups is increasingly being recognized as a clinical problem. One of the factors which may contribute to loosening is high localized deformation and stress at the cement-bone interface, the magnitude of which depends on the size of the total hip replacement (THR) femoral head. The effects of varying the femoral head size, from 22 to 32 mm, on strain values measured on the surface of the cup were investigated using experimental stress analysis techniques. The largest absolute strains were recorded when loading with the 22 mm head size. Peak strain values decreased to a minimum with the 26 mm head size and increased steadily with head sizes beyond 26 mm. The selection of an acetabular cup size and corresponding femoral head size in a total hip arthroplasty should not be an arbitrary one, but should be based on scientific studies which indicate minimum states of stress within the cup and cement mantle, as well as clinical evidence that the combination of components shows a reduced incidence of failure. This study experimentally quantifies the states of stress on the surface of the acetabular cup and points to the possible existence of an optimum component size to minimize surface stress.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号