首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sinderby, C., S. Friberg, N. Comtois, and A. Grassino.Chest wall muscle cross talk in the canine costal diaphragm electromyogram. J. Appl. Physiol.81(5): 2312-2327, 1996.The present paper describes the influenceof cross talk from the abdominal and intercostal muscles on the caninediaphragm electromyogram (EMG). The diaphragm EMG was recorded withbipolar surface electrodes placed on the costal portion of thediaphragm (abdominal side), aligned in the fiber direction, andpositioned in a region with a relatively low density of motor endplates. The results indicated that cross talk may occur in thediaphragm EMG, especially during conditions of loaded breathing andlight general anesthesia. The cross-talk signals showed characteristicsthat were entirely different from the diaphragm EMG. Although thediaphragm EMG was typical for signals recorded with electrodes alignedin the fiber direction, the cross-talk signals were characteristic ofthose obtained with electrode pairs not aligned in the direction of themuscle fibers. Alterations in electrode positioning, interelectrodedistance, and/or electrode surface area cannot guarantee theelimination of cross-talk signals, whereas spinal anesthesia at a highthoracic level will paralyze the sources of the cross talk and henceeliminate the cross-talk signals. By taking advantage of thedifferences in EMG signal characteristics for the diaphragm EMG andcross-talk signals, an index that has the capability to detect crosstalk was developed.

  相似文献   

2.
The linear electrode array: a useful tool with many applications.   总被引:4,自引:0,他引:4  
In this review we describe the basic principles of operation of linear electrode arrays for the detection of surface EMG signals, together with their most relevant current applications. A linear array of electrodes is a system which detects surface EMG signals in a number of points located along a line. A spatial filter is usually placed in each point for signal detection, so that the recording of EMG signals with linear arrays corresponds to the sampling in one spatial direction of a spatially filtered version of the potential distribution over the skin. Linear arrays provide indications on motor unit (MU) anatomical properties, such as the locations of the innervation zones and tendons, and the fiber length. Such systems allow the investigation of the properties of the volume conductor and its effect on surface detected signals. Moreover, linear arrays allow to estimate muscle fiber conduction velocity with a very low standard deviation of estimation (of the order of 0.1-0.2 m/s), thus providing reliable indications on muscle fiber membrane properties and their changes in time (for example with fatigue or during treatment). Conduction velocity can be estimated from a signal epoch (global estimate) or at the single MU level. In the latter case, MU action potentials are identified from the interference EMG signals and conduction velocity is estimated for each detected potential. In this way it is possible, in certain conditions, to investigate single MU control and conduction properties with a completely non-invasive approach. Linear arrays provide valuable information on the neuromuscular system properties and appear to be promising tools for applied studies and clinical research.  相似文献   

3.
Recently, high-density surface EMG electrode grids and multi-channel amplifiers became available for non-invasive recording of human motor units (MUs). We present a way to decompose surface EMG signals into MU firing patterns, whereby we concentrate on the importance of two-dimensional spatial differences between the MU action potentials (MUAPs). Our method is exemplified with high-density EMG data from the vastus lateralis muscle of a single subject. Bipolar and Laplacian spatial filtering was applied to the monopolar raw signals. From the single recording in this subject six different simultaneously active MUs could be distinguished using the spatial differences between MUAPs in the direction perpendicular to the muscle fiber direction. After spike-triggered averaging, 125-channel two-dimensional MUAP templates were obtained. Template-matching allowed tracking of all MU firings. The impact of spatial information was measured by using subsets of the MUAP templates, either in parallel or perpendicular to the muscle fiber direction. The use of one-dimensional spatial information perpendicular to the muscle fiber direction was superior to the use of a linear array electrode in the longitudinal direction. However, to detect the firing events of the MUs with a high accuracy, as needed for instance for estimation of firing synchrony, two-dimensional information from the complete grid electrode appears essential.  相似文献   

4.
For research as well as diagnostic applications the non-invasive detection of the activity of single motor units is of interest. The most direct information is expected to be found in monopolarly recorded data. But when an array of surface electrodes is used for the monopolar recordings of the potential distribution on the skin, in most cases an additional invasive needle electrode is utilized to detect the exact points in time when a certain motor unit is firing. With this supplementary information, an averaging of the monopolar EMG tracings can be performed. In this paper, a completely non-invasive methodology is presented which replaces the invasive needle by a spatial filtering procedure. The EMG signals from the m. biceps brachii are recorded monopolarly with an electrode array. Afterwards, a spatial filtering procedure, called normal double differentiating filter, is applied to the data. The EMG signals obtained are investigated by means of an amplitude threshold to distinguish the activity of different motor units. The point of the maximum amplitude of the selected peaks then is used as trigger point to average the monopolar EMG data. The time courses of the motor unit action potential signals found after applying the described procedure show similar shapes, while two different components are to be identified: corresponding to the spread of the excitation, one is referring to stationary, the other to travelling events. These results justify the possibility to replace the needle electrode to obtain a trigger event in the future by the non-invasive spatial filtering procedure.  相似文献   

5.
This paper focuses on methodological issues related to surface electromyographic (EMG) signal detection from the low back muscles. In particular, we analysed (1) the characteristics (in terms of propagating components) of the signals detected from these muscles; (2) the effect of electrode location on the variables extracted from surface EMG; (3) the effect of the inter-electrode distance (IED) on the same variables; (4) the possibility of assessing fatigue during high and very low force level contractions. To address these issues, we detected single differential surface EMG signals by arrays of eight electrodes from six locations on the two sides of the spine, at the levels of the first (L1), the second (L2), and the fifth (L5) lumbar vertebra. In total, 42 surface EMG channels were acquired at the same time during both high and low force, short and long duration contractions. The main results were: (1) signal quality is poor with predominance of non-travelling components; (2) as a consequence of point (1), in the majority of the cases it is not possible to reliably estimate muscle fiber conduction velocity; (3) despite the poor signal quality, it was possible to distinguish the fatigue properties of the investigated muscles and the fatigability at different contraction levels; (4) IED affects the sensitivity of surface EMG variables to electrode location and large IEDs are suggested when spectral and amplitude analysis is performed; (5) the sensitivity of surface EMG variables to changes in electrode location is on average larger than for other muscles with less complex architecture; (6) IED influences amplitude initial values and slopes, and spectral variable initial values; (7) normalized slopes for both amplitude and spectral variables are not affected by IED and, thus, are suggested for fatigue analysis at different postures or during movement, when IED may change in different conditions (in case of separated electrodes); (8) the surface EMG technique at the global level of amplitude and spectral analysis cannot be used to characterize fatigue properties of low back muscles during very low level, long duration contractions since in these cases the non-stable MU pool has a major influence on the EMG variables. These considerations clarify issues only partially investigated in past studies. The limitations indicated above are important and should be carefully discussed when presenting surface EMG results as a means for low back muscle assessment in clinical practice.  相似文献   

6.
Cross-correlation between surface electromyogram (EMG) signals is commonly used as a means of quantifying EMG cross talk during voluntary activation. To examine the reliability of this method, the relationship between cross talk and the cross-correlation between surface EMG signals was examined by using model simulation. The simulation results illustrate an increase in cross talk with increasing subcutaneous fat thickness. The results also indicate that the cross-correlation function decays more rapidly with increasing distance from the active fibers than cross talk, which was defined as the normalized EMG amplitude during activation of a single muscle. The influence of common drive and short-term motor unit synchronization on the cross-correlation between surface EMG signals was also examined. While common drive did not alter the maximum value of the cross-correlation function, the correlation increased with increasing motor unit synchronization. It is concluded that cross-correlation analysis is not a suitable means of quantifying cross talk or of distinguishing between cross talk and coactivation during voluntary contraction. Furthermore, it is possible that a high correlation between surface EMG signals may reflect an association between motor unit firing times, for example due to motor unit synchronization.  相似文献   

7.
The different techniques to measure and analyze surface EMG are summarized with an emphasis on the clinician's point of view. The application of surface EMG in neurological disease is hampered by many inherent problems, especially the difficulties in extracting features of single motor units. However, the evolution of surface EMG from single bipolar recordings via a linear array of multiple electrodes to densely packed, multi-channel electrode arrays could in principle solve this problem. The added value of using multiple channels (up to 128) with an interelectrode distance of a few millimetres to obtain more spatial information is emphasized. At least for some muscles it is now possible to extract information from the surface EMG, conventionally thought to belong to the domain of needle EMG (for example the "electrical size" of motor units). The use of analysis techniques such as the estimation of muscle fiber conduction velocity has already proven to be of diagnostic value in several myopathies characterized by a disturbed membrane function and in metabolic myopathies with abnormal fatigue profiles. Future research should be directed at the development of analysis techniques enabling the extraction of more relevant motor unit variables from surface EMG signals.  相似文献   

8.
This study analyses the spatial distribution of individual motor unit potentials (MUPs) over the skin surface and the influence of motor unit depth and recording configuration on this distribution. Multichannel surface (13 × 5 electrode grid) and intramuscular (wire electrodes inserted with needles of lengths 15 and 25 mm) electromyographic (EMG) signals were concurrently recorded with monopolar derivations from the biceps brachii muscle of 10 healthy subjects during 60-s isometric contractions at 20% of the maximum torque. Multichannel monopolar MUPs of the target motor unit were obtained by spike-triggered averaging of the surface EMG. Amplitude and frequency characteristics of monopolar and bipolar MUPs were calculated for locations along the fibers’ direction (longitudinal), and along the direction perpendicular (transverse) to the fibers. In the longitudinal direction, monopolar and bipolar MUPs exhibited marked amplitude changes that extended for 16–32 mm and 16–24 mm over the innervation and tendon zones, respectively. The variation of monopolar and bipolar MUP characteristics was not symmetrical about the innervation zone. Motor unit depth had a considerable influence on the relative longitudinal variation of amplitude for monopolar MUPs, but not for bipolar MUPs. The transverse extension of bipolar MUPs ranged between 24 and 32 mm, whereas that of monopolar MUPs ranged between 72 and 96 mm. The mean power spectral frequency of surface MUPs was highly dependent on the transverse electrode location but not on depth. This study provides a basis for the interpretation of the contribution of individual motor units to the interference surface EMG signal.  相似文献   

9.
Surface electromyogram (EMG) detected by electrode arrays along the muscle fibre direction can be approximated by the sum of propagating and non propagating components. A technique to separate propagating and non propagating components in surface EMG signals is developed. The first step is an adaptive filter, which allows obtaining an estimation of the delay between signals detected at different channels and a first estimate of propagating and non propagating components; the second step is used to optimise the estimation of the two components. The method is applicable to signals with one propagating and one non propagating component. It was optimised on simulated signals, and then applied to single motor unit action potentials (MUAP) and to electrically elicited EMG (M-waves).

The new method was first tested on phenomenological signals constituted by the sum of a propagating and a non propagating signal and then applied to simulated and experimental EMG signals. Simulated signals were generated by a cylindrical, layered volume conductor model. Experimental signals were monopolar surface EMG signals collected from the abductor pollicis brevis muscle and M-waves recorded during transcutaneous electrical stimulation of the biceps muscle. The technique may find different applications: in single motor unit (MU) studies (a) for decreasing the variability and bias of CV estimates due to the presence of the non propagating components, (b) for estimating automatically the length of the muscle fibres from only three detected channels and (c) for removal of the stimulation artifact M-waves.  相似文献   


10.
The purposes of this investigation were to examine the effects of electrode placement and innervation zone (IZ) location on: (a) the torque-related patterns of responses for absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) and (b) the mean absolute and normalized EMG amplitude and MPF values. In addition, the present study examined the variability between subjects for the location of the IZ for the vastus lateralis (VL). Eight men (mean+/-SD age=23.0+/-4.3yr) performed submaximal to maximal isometric muscle actions of the dominant leg extensors. During each muscle action, fifteen channels of bipolar surface EMG signals were detected from the vastus lateralis using a linear electrode array aligned with the long axis of the muscle fibers. The results indicated that there were differences among channels 1-15 for the patterns of responses and mean values for absolute and normalized EMG amplitude and MPF versus isometric torque. Thus, normalized EMG amplitude and MPF values from different individuals cannot be compared if the EMG signals were detected from different locations over the muscle. In addition, absolute and relative (to femur length) estimates of IZ location for the VL resulted in similar inter-subject variability.  相似文献   

11.
Surface EMG is an important tool in biomechanics, kinesiology and neurophysiology. In neurophysiology the concept of high-density EMG (HD-EMG), using two dimensional electrode grids, was developed for the measurement of spatiotemporal activation patterns of the underlying muscle and its motor units (MU). The aim of this paper was to determine, with the aid of a HD-EMG grid, the relative importance of a number of electrode sensor configurations for optimizing muscle force estimation. Sensor configurations are distinguished in two categories. The first category concerns dimensions: the size of a single electrode and the inter electrode distance (IED). The second category concerns the sensor's spatial distribution: the total area from which signals are obtained (collection surface) and the number of electrodes per cm(2) (collection density). Eleven subjects performed isometric arm extensions at three elbow angles and three contraction levels. Surface-EMG from the triceps brachii muscle and the external force at the wrist were measured. Compared to a single conventional bipolar electrode pair, the force estimation quality improved by about 30% when using HD-EMG. Among the sensor configurations, the collection surface alone appeared to be responsible for the major part of the EMG based force estimation quality by improving it with 25%.  相似文献   

12.
A doublet is defined as two consecutive discharges of a motor unit occurring at short time interval between each other (e.g., <20 ms). In this paper, we propose a method for the estimation of muscle fiber conduction velocity (CV) from two partly overlapping action potentials generated by the same motor units. The method is based on the minimization of the mean square error between time-filtered versions of two surface EMG signals recorded along the direction of muscle fibers. The minimization is performed over the filter parameters that define the two propagation delays. The method was tested on simulated and experimental signals. Simulation results showed that the method is only in some cases superior to the simpler peak approach, due to limitations in the ideal model used for the algorithm development. However, application to experimental signals that mimic doublet motor unit discharges showed a substantial improvement in estimation quality of the new method with respect to the peak method.  相似文献   

13.
The purpose of this study was to explore changes in spatial muscle activation within the three divisions of the trapezius muscle during a dynamic, cyclic task of the upper limb. Surface EMG signals were detected from thirteen healthy subjects from the upper, middle and lower divisions of the trapezius muscle at multiple electrode sites in the cephalad-caudal direction during a repetitive shoulder flexion task. Initial values and rate of change of average rectified value (ARV) and of instantaneous mean power spectral frequency (iMNF) were estimated at 45 degrees , 90 degrees and 120 degrees of shoulder flexion throughout the 5-min task. The location of the electrodes had a significant effect on initial EMG ARV for both the upper and middle division of the trapezius muscle (P<0.05). Both the rate of change and normalized rate of change of ARV were greatest for the most cranial muscle fibers of the upper division (P<0.05). Initial values and rates of change of iMNF were also affected by electrode location for the upper and lower divisions of the trapezius muscle (P<0.05). These results demonstrate that muscle activity and its changes over time depend on position within the three divisions of the trapezius muscle during a dynamic, cyclic task of the upper limb. This suggests non-uniform muscle fiber distribution and/or recruitment. The results also highlight the importance of multiple recording sites when investigating trapezius muscle function in dynamic tasks.  相似文献   

14.
The aim of the study was to investigate the correlation between myosin heavy chain (MHC) composition, lactate threshold (LT), maximal oxygen uptake VO2max, and average muscle fiber conduction velocity (MFCV) measured from surface electromyographic (EMG) signals during cycling exercise. Ten healthy male subjects participated in the study. MHC isoforms were identified from a sample of the vastus lateralis muscle and characterized as type I, IIA, and IIX. At least three days after a measure of LT and VO2max, the subjects performed a 2-min cycling exercise at 90 revolutions per minute and power output corresponding to LT, during which surface EMG signals were recorded from the vastus lateralis muscle with an adhesive electrode array. MFCV and instantaneous mean power spectral frequency of the surface EMG were estimated at the maximal instantaneous knee angular speed. Output power corresponding to LT and VO2max were correlated with percentage of MHC I (R2=0.77; and 0.42, respectively; P<0.05). MFCV was positively correlated with percentage of MHC I, power corresponding to LT and to VO2max (R2=0.84; 0.74; 0.53, respectively; P<0.05). Instantaneous mean power spectral frequency was not correlated with any of these variables or with MFCV, thus questioning the use of surface EMG spectral analysis for indirect estimation of MFCV in dynamic contractions.  相似文献   

15.
The purpose of this paper was to evaluate the effects of the longitudinal single differential (LSD), the longitudinal double differential (LDD) and the normal double differential (NDD) spatial filters, the electrode shape, the inter-electrode distance (IED) on non-Gaussianity and non-linearity levels of simulated surface EMG (sEMG) signals when the maximum voluntary contraction (MVC) varied from 10% to 100% by a step of 10%. The effects of recruitment range thresholds (RR), the firing rate (FR) strategy and the peak firing rate (PFR) of motor units were also considered.A cylindrical multilayer model of the volume conductor and a model of motor unit (MU) recruitment and firing rate were used to simulate sEMG signals in a pool of 120 MUs for 5 s. Firstly, the stationarity of sEMG signals was tested by the runs, the reverse arrangements (RA) and the modified reverse arrangements (MRA) tests. Then the non-Gaussianity was characterised with bicoherence and kurtosis, and non-linearity levels was evaluated with linearity test.The kurtosis analysis showed that the sEMG signals detected by the LSD filter were the most Gaussian and those detected by the NDD filter were the least Gaussian. In addition, the sEMG signals detected by the LSD filter were the most linear. For a given filter, the sEMG signals detected by using rectangular electrodes were more Gaussian and more linear than that detected with circular electrodes. Moreover, the sEMG signals are less non-Gaussian and more linear with reverse onion-skin firing rate strategy than those with onion-skin strategy. The levels of sEMG signal Gaussianity and linearity increased with the increase of the IED, RR and PFR.  相似文献   

16.
A model of the motor unit action potential was developed to investigate the amplitude and frequency spectrum contributions of motor units, located at various depths within muscle, to the surface detected electromyographic (EMG) signal. A dipole representation of the transmembrane current in a three-dimensional muscle volume was used to estimate detected individual muscle fiber action potentials. The effects of anisotropic muscle conductance, innervation zone location, propagation velocity, fiber length, electrode area, and electrode configuration were included in the fiber action potential model. A motor unit action potential was assumed to be the sum of the individual muscle fiber action potentials. A computational procedure, based on the notion of isopotential layers, was developed which substantially reduced the calculation time required to estimate motor unit action potentials. The simulations indicated that: 1) only those motor units with muscle fibers located within 10–12 mm of the electrodes would contribute significant signal energy to the surface EMG, 2) variation in surface area of electrodes has little effect on the detection depth of motor unit action potentials, 3) increased interelectrode spacing moderately increases detection depth, and 4) the frequency content of action potentials decreases steeply with increased electrode-motor unit territory distance.  相似文献   

17.
The upper trapezius (UT) has been widely studied and related to alterations in clavicular kinematics in subject with shoulder disorders. However, the most common electrode site used to capture UT EMG is between C7 and the acromion, placing the electrodes over the acromial fibers rather than clavicular ones. Therefore, this study aimed to investigate the relationship between clavicular movements (elevation and retraction) and UT EMG recorded from three electrode sites (traditional electrode positioning and two different sites proposed for clavicular fibers evaluation). Furthermore, the position associated with the highest EMG during maximal isometric voluntary contractions (MVIC), for each electrode site, was determined for normalization purposes. EMG was simultaneously captured in the three electrode sites of 20 healthy subjects, during MVIC at five different positions and during shoulder elevation and abduction in scapular plane. Clavicular kinematics was recorded using an electromagnetic tracking system during the dynamic contractions. Shoulder abduction with head rotation and lateral flexion elicited the highest EMG amplitude on the three electrode sites and was used to normalize the signals. A cross-correlation analysis showed high correlations between all electrode sites and clavicular movements. However, the traditional electrode site seems to record more informative signals in healthy subjects.  相似文献   

18.
The purpose of the study was to quantify the influence of amplitude cancellation on the accuracy of detecting the onset of muscle activity based on an analysis of simulated surface electromyographic (EMG) signals. EMG activity of a generic lower limb muscle was simulated during the stance phase of human gait. Surface EMG signals were generated with and without amplitude cancellation by summing simulated motor unit potentials either before (cancellation EMG) or after (no-cancellation EMG) the potentials had been rectified. The two sets of EMG signals were compared at forces of 30% and 80% of maximum voluntary contraction (MVC) and with various low-pass filter cut-off frequencies. Onset time was determined both visually and by an algorithm that identified when the mean amplitude of the signal within a sliding window exceeded a specified standard deviation (SD) above the baseline mean. Onset error was greater for the no-cancellation conditions when determined automatically and by visual inspection. However, the differences in onset error between the two cancellation conditions appear to be clinically insignificant. Therefore, amplitude cancellation does not appear to limit the ability to detect the onset of muscle activity from the surface EMG.  相似文献   

19.
Before using electromyographic (EMG) variables such as muscle fiber conduction velocity (MFCV) and the mean or median frequency (MDF) of an EMG power spectrum as indicators of muscular fatigue during dynamic exercises, it is necessary to determine the influence of a joint angle, contraction force and contraction speed on the EMG variables. If these factors affect the EMG variables, their influence must be removed or compensated for before discussing fatigue. The vastus lateralis of eight normal healthy male adults was studied. EMG signals during non-fatiguing dynamic knee extension exercises were detected with a three-bar active surface electrode array. EMG variables were calculated from the detected signals and compared with the angle of the knee joint, the extension torque and the extension speed. The extension torque was set at four levels with 10% intervals between 40 and 70% of the maximum voluntary contraction. The extension speed was set at five levels with 60 degrees /s intervals between 0 and 240 degrees /s. Because the joint angle unsystematically affected the MFCV, EMG variables at a given joint angle were extracted for comparison. The influence of the extension torque and speed on the extracted EMG variables was clarified with an ANOVA and a regression analysis. The statistical analyses showed that MFCV increased with the extension torque but did not depend on the extension speed. In contrast, MDF was independent of the extension torque but was dependent on the extension speed. MDF thus showed a behavior different from that of MFCV. It became clear that if MFCV is used as an indicator of muscular fatigue during dynamic exercises, it is at least necessary to extract MFCV at a predetermined joint angle and then remove the influence of extension torque on MFCV.  相似文献   

20.
Interpretation of surface electromyograms (EMG) is usually based on the assumption that the surface representation of action potentials does not change during their propagation. This assumption does not hold for muscles whose fibers are oblique to the skin. Consequently, the interpretation of surface EMGs recorded from pinnate muscles unlikely prompts from current knowledge. Here we present a complete analytical model that supports the interpretation of experimental EMGs detected from muscles with oblique architecture. EMGs were recorded from the medial gastrocnemius muscle during voluntary and electrically elicited contractions. Preliminary indications obtained from simulated and experimental signals concern the spatial localization of surface potentials and the myoelectric fatigue. Specifically, the spatial distribution of surface EMGs was localized about the fibers superficial extremity. Strikingly, this localization increased with the pinnation angle, both for the simulated EMGs and the recorded M-waves. Moreover, the average rectified value (ARV) and the mean frequency (MNF) of interference EMGs increased and decreased with simulated fatigue, respectively. The degree of variation in ARV and MNF did not depend on the pinnation angle simulated. Similar variations were observed for the experimental EMGs, although being less evident for a higher fiber inclination. These results are discussed on a physiological context, highlighting the relevance of the model proposed here for the interpretation of gastrocnemius EMGs and for conceiving future experiments on muscles with pinnate geometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号