首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Almost 90% of the Trinidad strain of Venezuelan equine encephalomyelitis (VEE) virus survived for 1 hr after aerosolization into a dark environment at 30% relative humidity (RH), and 78% survived for 1 hr at 60% RH. After exposure to simulated solar radiation (584 mcal per cm(2) per min) 0.02% of the aerosolized virus survived for 1 hr at 30% RH and 0.006% survived for 1 hr at 60% RH. When 1.0 mg of sodium fluorescein per ml was added to suspensions prior to aerosol dissemination (to determine physical loss of aerosol), no virus was detected after 30 min at either RH upon irradiation. Sodium fluorescein also exhibited some toxicity (31% survival at 60 min) for nonirradiated aerosols of VEE virus at 60% RH; no effect was noted at 30%.  相似文献   

2.
The aerosol survival in air and in nitrogen was measured for Pasteurella tularensis live vaccine strain, disseminated from the wet and dry states. The results showed that most of the loss of viability occurred in less than 2 min of aerosol age, i.e., a rapid initial decay followed by a much slower secondary decay. In nitrogen and air, minimum survival occurred at 50 to 55% relative humidity (RH) for wet dissemination and at 75% RH for dry dissemination. This shift indicated that aerosols produced by wet and dry dissemination were not equivalent and suggested that survival might not be related to bacterial water activity or content. The results showed that rehydration is the key process with regard to survival, but that lysis on rehydration is not a primary death mechanism. The effects of oxygen were complex because it could be either protective or toxic, depending upon other conditions. The protective action of oxygen was through an effect on the spent culture suspending fluid. The latter contained a toxic component, the activity of which is suppressed by oxygen; possibly the component is pumped away during freeze-drying. A toxic effect of oxygen was not found in the presence of spent culture media because the toxicity of the latter masks such an effect. With other bacterial suspending fluids, oxygen was shown to be toxic at low RH. Similar effects with regard to oxygen toxicity were also found with a laboratory strain of P. tularensis. Differences in oxygen toxicity for aerosols generated from the wet and dry states also suggest that bacterial water content and activity do not control aerosol survival.  相似文献   

3.
Rotavirus SA11, suspended in tryptose phosphate broth with 2.5 mg of rhodamine B per ml, was aerosolized (Collison nebulizer) into a rotating drum, and the aerosols were held at 20 +/- 1 degree C with the desired relative humidity (RH). An all-glass impinger with tryptose phosphate broth was used to collect 1-min (5.6-liter) samples of air from the drum. The virus was found to survive best at medium (50 +/- 5%) RH, where its half-life was nearly 40 h. The half-life of the virus at the low (25 +/- 5%) RH level was about 9 h. Even at 72 h of aerosol age, 45 and 21% of the infectious virus remained detectable in the air at the medium and low RH levels, respectively. The high (80 +/- 5%) RH level was found to be the least favorable to the survival of the virus, since 50% of the infectious virus became undetectable within 2 h of aerosolization. In a separate experiment at the midrange RH, 3% of the infectious virus was detectable in the drum air after 223 h (9 days) of aerosol age. Rotaviruses could, therefore, survive in air for prolonged periods, thus making air a possible vehicle for their dissemination.  相似文献   

4.
Rotavirus SA11, suspended in tryptose phosphate broth with 2.5 mg of rhodamine B per ml, was aerosolized (Collison nebulizer) into a rotating drum, and the aerosols were held at 20 +/- 1 degree C with the desired relative humidity (RH). An all-glass impinger with tryptose phosphate broth was used to collect 1-min (5.6-liter) samples of air from the drum. The virus was found to survive best at medium (50 +/- 5%) RH, where its half-life was nearly 40 h. The half-life of the virus at the low (25 +/- 5%) RH level was about 9 h. Even at 72 h of aerosol age, 45 and 21% of the infectious virus remained detectable in the air at the medium and low RH levels, respectively. The high (80 +/- 5%) RH level was found to be the least favorable to the survival of the virus, since 50% of the infectious virus became undetectable within 2 h of aerosolization. In a separate experiment at the midrange RH, 3% of the infectious virus was detectable in the drum air after 223 h (9 days) of aerosol age. Rotaviruses could, therefore, survive in air for prolonged periods, thus making air a possible vehicle for their dissemination.  相似文献   

5.
Vegetative cells of Serratia marcescens 8UK, Sarcina lutea, and spores of Bacillus subtilus var. niger were held in aerosols, with and without an urban concentration of CO (85 muliters per liter or ppm), for up to 6 hr at 15 C and a relative humidity (RH) of approximately 0, 25, 50, 75, and 95%. It was found that CO enhanced the death rate of S. marcescens 8UK at least four- to sevenfold at low RH (ca. 1 to 25%), but protected the cells at high RH (ca. 90%). Death rates of S. lutea, with or without added CO, were comparatively low over the entire RH range. However, in the first hour, airborne S. lutea held in CO-containing air were more stable than those in air without added CO (i.e., CO protection). A marked increase in the death rate (up to 70-fold) occurred in the subsequent 5 hr within the RH range of approximately 0 to 75%. Statistical analysis indicated that aerosol decay rates of B. subtilus var. niger spores decreased significantly, when held in a CO-containing as compared to a non-CO-containing atmosphere, in the 0 to 85% RH range. Thus, the data presented indicate that CO in the urban environment may have a protective or lethal effect on airborne bacteria, dependent upon at least the microbial species, aerosol age, and relative humidity. A mechanism for CO death enhancement and protection of airborne S. marcescens 8UK is suggested to involve CO uncoupling of an energy-requiring death mechanism and an energy-requiring maintenance mechanism at high and low RH, respectively.  相似文献   

6.
A mixture of a cell culture-adapted strain (C-486) of calf rotavirus and poliovirus type 1 (Sabin) was prepared in tryptose phosphate broth containing 0.1% uranine (physical tracer) and antifoam at a final concentration of 0.001%. By using a six-jet Collison nebulizer, the mixture was aerosolized into a 300-liter stainless-steel rotating (4 rpm) drum. The temperature of the air inside the drum was kept at 20 +/- 1 degrees C, and the virus aerosols were held at the following three levels of relative humidity (RH): low (30 +/- 5%), medium (50 +/- 5%), and high (80 +/- 5%). An all-glass impinger, containing 10.0 ml of tryptose phosphate broth with antifoam, was used to collect samples of air from the drum. Both viruses were propagated and quantitated in MA-104 cells. The calf rotavirus was found to survive well at mid-range RH, where 60% of the infectious virus could be detected even after 24 h of virus aerosolization. At the low RH, the half-life of the infectious rotavirus was ca. 14 h. On the other hand, no infectious poliovirus could be recovered from the drum air at the low and medium RH. At the high RH, more than 50% of the infectious rotavirus became undetectable within 90 min of aerosolization. In contrast to this, the half-life of the poliovirus at the high RH was about 10 h. These data, based on the aerosolization of virus mixtures, therefore suggest that there is a pronounced difference in the way RH influences the airborne survival of these two types of viruses held under identical experimental conditions.  相似文献   

7.
A mixture of a cell culture-adapted strain (C-486) of calf rotavirus and poliovirus type 1 (Sabin) was prepared in tryptose phosphate broth containing 0.1% uranine (physical tracer) and antifoam at a final concentration of 0.001%. By using a six-jet Collison nebulizer, the mixture was aerosolized into a 300-liter stainless-steel rotating (4 rpm) drum. The temperature of the air inside the drum was kept at 20 +/- 1 degrees C, and the virus aerosols were held at the following three levels of relative humidity (RH): low (30 +/- 5%), medium (50 +/- 5%), and high (80 +/- 5%). An all-glass impinger, containing 10.0 ml of tryptose phosphate broth with antifoam, was used to collect samples of air from the drum. Both viruses were propagated and quantitated in MA-104 cells. The calf rotavirus was found to survive well at mid-range RH, where 60% of the infectious virus could be detected even after 24 h of virus aerosolization. At the low RH, the half-life of the infectious rotavirus was ca. 14 h. On the other hand, no infectious poliovirus could be recovered from the drum air at the low and medium RH. At the high RH, more than 50% of the infectious rotavirus became undetectable within 90 min of aerosolization. In contrast to this, the half-life of the poliovirus at the high RH was about 10 h. These data, based on the aerosolization of virus mixtures, therefore suggest that there is a pronounced difference in the way RH influences the airborne survival of these two types of viruses held under identical experimental conditions.  相似文献   

8.
Survival was determined for Escherichia coli B disseminated as an aerosol from the dry state. Survival in nitrogen, like that for wet dissemination, was better at low than at high relative humidity (RH). At high RH, survival was characterized by critical zones of instability in survival as a function of RH, instability occurring at 100, 95, 78, 70, and 60% RH. In air, survival was inferior to that in nitrogen at low RH, whereas the converse was found at high RH. The effect was attributed to oxygen. In general, results support the conclusion that to the first approximation survival is related to bacterial water content, the latter increasing with RH. However, a more detailed analysis of results indicates that survival might not be exactly related to bacterial water content. It is shown that death occurred because of rehydration and that the pretreatment of E. coli B affected its aerosol stability characteristics; i.e., wet and dry disseminated aerosols are not equivalent.  相似文献   

9.
An aerodynamic particle sizer (APS) that uses laser Doppler velocimetry was used to determine aerodynamic diameters of spores of fungal and thermophilic actinomycete species common in mouldy hay, aerosolized at different humidities and temperatures. Results were compared with those obtained from inertial impaction in a cascade impactor. The APS gave slightly smaller measurements than the cascade impactor. Both methods gave aerodynamic diameters generally slightly smaller than the average spore dimensions observed on cascade impactor slides with a microscope. The latter measurements were less than axial dimensions given in the literature. Brief passage of spores through air at 95% relative humidity (RH) and 38 degrees C, compared with 40% RH and 20 degrees C, caused an immediate increase in their aerodynamic diameter and the breaking of chains of spores. Cultures maintained at 75% RH and aerosolized at 98% RH similarly produced larger spore particles than those passed through dry air. These findings have implications for mould-induced asthma and allergic alveolitis since they relate to physical behaviour of airborne spores and particle deposition sites in the lung.  相似文献   

10.
The survival of Chlamydia pneumoniae in aerosols was investigated by using a chamber with a capacity of 114.5 liters. We injected 5 x 10(7) inclusion-forming units (IFU) of C. pneumoniae in aerosols with a droplet size of 3 to 5 microns. Samples were taken after 30 s and every 1 min thereafter. The survival of C. pneumoniae was measured at four temperatures (8.5, 15, 25, and 35 degrees C) and at three different relative humidities (RH) of 5, 50, and 95% for each temperature. The survival rates of Streptococcus pneumoniae, Streptococcus faecalis, Klebsiella pneumoniae, Chlamydia trachomatis LGV2, and cytomegalovirus were also determined at 25 degrees C and 95% RH and compared with that of C. pneumoniae. At the mentioned temperatures and RH, a rapid decrease of C. pneumoniae IFU was observed in the first 30 s. After this the decrease in the number of IFU was more gradual. The survival of C. pneumoniae in aerosols were optimal at 15 to 25 degrees C and 95% RH; it was good compared with those of other microorganisms. A lower death rate was observed only in S. faecalis. In C. trachomatis, the death rate during the first 30 s was higher than that in C. pneumoniae (85 and 53.3%, respectively). After the first 30 s, the death rates in the two organisms were identical. It was concluded that transmission of C. pneumoniae via aerosols was possible. There is probably a direct transmission from person to person, taking into account the relatively short survival period of C. pneumoniae in aerosols.  相似文献   

11.
Effect of relative humidity on the airborne survival of rhinovirus-14   总被引:5,自引:0,他引:5  
Rhinovirus-14, suspended in tryptose phosphate broth supplemented with uranine (physical tracer) and an antifoam, was aerosolized by use of a Collison nebulizer. The aerosols were held in a rotating drum with the relative humidity at either the low (30 +/- 5%), medium (50 +/- 5%), or high (80 +/- 5%) level at 20 +/- 1 degrees C. An all-glass impinger was used to recover the virus from the air in the drum, with the first air sample being collected after a 15-min period of aerosol stabilization. Subsequent air samples were withdrawn at 2, 4, 8, and 14 h after stabilization of the aerosol. At the low and medium relative humidity levels, the infectivity of the airborne virus was rapidly lost and less than 0.25% could be detected in the first air sample. At the high RH level, however, the airborne virus had a half-life of 13.7 +/- 1.91 h and nearly 30% of the input infectious virus could be detected in the drum air even after 24 h of aerosolization. These findings suggest that under certain environmental conditions, notably high relative humidity, air may act as a vehicle for the spread of rhinovirus infections.  相似文献   

12.
Three strains of Pseudomonas aeruginosa were directly exposed on the surface of membrane filters to hyperoxic atmospheres. One of the three strains was found to be sensitive to oxygen. Colonies failed to appear during 18 hr of incubation in pure oxygen at 1 atm, but about 40% of the bacteria recovered to produce colonies upon reincubation in air. Similar killing was produced by 10 hr of oxygen exposure. No inhibition or killing was observed with two other strains. Streptomycin (1mug/ml) and kanamycin (5mug/ml) were more effective in killing the oxygen-sensitive strain in the presence of 60 to 70% oxygen than in air, but polymyxin B (5mug/ml) did not show a synergistic effect under such conditions.  相似文献   

13.
Studies were undertaken to determine if a prewetting device (humidifier bulb) used in combination with an all glass impinger (AGI-30) would increase the recovery of airborne mengovirus-37A, vesicular stomatitis virus (VSV), and the S-13 coliphage. Suspensions of T3 coliphage with mengovirus-37A, VSV, or S-13 were aerosolized and collected by using the AGI-30-humidifier bulb combination to sample the aerosols before and after shifts in relative humidities (RH). These studies revealed the following. (i) At low RH values there was a 3 to 4 log increase in recovery of airborne T3 phage; (ii) concomitantly, the recovery of mengovirus-37A and VSV decreased; and (iii) only at the mid-range RH values was the recovery of S-13 enhanced. The prehumidification technique significantly increased the recovery of airborne T3 phage but decreased the recovery of the two animal viruses tested.  相似文献   

14.
Airborne Stability of Simian Virus 40   总被引:1,自引:0,他引:1       下载免费PDF全文
The influence of relative humidity on the airborne survival of simian virus 40 (SV40) was studied by allowing virus aerosols to age in rotating drums at 21 or 32 C and at a relative humidity (RH) value ranging from 22 to 88%. Airborne SV40 virus was stable at every RH tested at 21 C, but aerosols maintained at 32 C were inactivated within 60 min at mid-range RH values. The unusual stability at 21 C over a broad RH range indicates that potentially biohazardous situations may occur under laboratory conditions if this virus becomes accidentally airborne.  相似文献   

15.
Survival of airborne virus influences the extent of disease transmission via air. How environmental factors affect viral survival is not fully understood. We investigated the survival of a vaccine strain of Gumboro virus which was aerosolized at three temperatures (10°C, 20°C, and 30°C) and two relative humidities (RHs) (40% and 70%). The response of viral survival to four metrics (temperature, RH, absolute humidity [AH], and evaporation potential [EP]) was examined. The results show a biphasic viral survival at 10°C and 20°C, i.e., a rapid initial inactivation in a short period (2.3 min) during and after aerosolization, followed by a slow secondary inactivation during a 20-min period after aerosolization. The initial decays of aerosolized virus at 10°C (1.68 to 3.03 ln % min(-1)) and 20°C (3.05 to 3.62 ln % min(-1)) were significantly lower than those at 30°C (5.67 to 5.96 ln % min(-1)). The secondary decays at 10°C (0.03 to 0.09 ln % min(-1)) tended to be higher than those at 20°C (-0.01 to 0.01 ln % min(-1)). The initial viral survival responded to temperature and RH and potentially to EP; the secondary viral survival responded to temperature and potentially to RH. In both phases, survival of the virus was not significantly affected by AH. These findings suggest that long-distance transmission of airborne virus is more likely to occur at 20°C than at 10°C or 30°C and that current Gumboro vaccination by wet aerosolization in poultry industry is not very effective due to the fast initial decay.  相似文献   

16.
Aims: To assess the effectiveness of iodine-treated biocidal filter media against bacterial spore aerosols. Methods and Results: Bacillus subtilis spores were aerosolized and introduced into a filtration system. Both treated and untreated filters exhibited high viable removal efficiency (>99·996%) with negligible variation in pressure drop during the entire experiment. The viability of collected spores on the filter was investigated by enumeration of spores extracted from the filter by vortexing. At room temperature and low relative humidity (RH), the survival fraction of the treated filter was significantly lower than that of the untreated filter (P-value < 0·05). Meanwhile, at room temperature and high RH and at high temperature and high RH, the survival fractions on the treated medium were statistically the same as the untreated control at room temperature and low RH. Conclusions: Both treated and untreated filters achieved excellent viable removal efficiency for spores. The pressure drop of the treated filter was not affected by the iodine treatment. The viability of collected bacterial spores was decreased because of the exertion of iodine disinfectant. Significance and Impact of the Study: The evaluation demonstrates that the iodine-treated filter is a viable medium for respiratory protection against infectious spore aerosols. The results warrant further evaluation of smaller biological agents, which exhibit higher penetration.  相似文献   

17.
Andersen air samplers were used to determine the particle size distribution of Serratia marcescens aerosols created during several common laboratory procedures and simulated laboratory accidents. Over 1,600 viable particles per cubic foot of air sampled were aerosolized during blending operations. More than 98% of these particles were less than 5 mu in size. In contrast, 80% of the viable particles aerosolized by handling lyophilized cultures were larger than 5 mu. Harvesting infected eggs, sonic treatment, centrifugation, mixing cultures, and dropping infectious material produced aerosols composed primarily of particles in the 1.0- to 7.5-mu size range.  相似文献   

18.
Airborne Pasteurella pestis (A-1122) at low humidities [20 to 50% relative humidity (RH)] exhibited exponential decay when either 1% peptone or Heart Infusion Broth (HIB) was used as the diluent in the viable assay system. At higher RH values (65 and 87%), however, the 1% peptone diluent adversely affected the viability assay. In contrast, HIB as diluent was remarkably effective in demonstrating a higher number of viable cells in aerosols held at high RH values. Similarly, with HIB as diluent, aerosols were shown to contain viable cells during 90 min of observation; with 1% peptone, viability was not detectable after 20 min in the airborne state.  相似文献   

19.
Survival of Rhizobium meliloti 102F5 in aerosols at 20 C was maximal at high relative humidity (RH) and minimal at low RH. Relatively high concentrations of NO(2), SO(2), or formaldehyde were needed to significantly reduce viability of R. meliloti in aerosols at 50% RH. Except for the reduction in activity of formaldehyde by SO(2), there was no additive or antagonistic effect of mixing pollutants. High environmental RH enhanced bactericidal activity of NO(2) and SO(2). High RH minimized and low RH accentuated the biological effect of ultraviolet light of 300 to 400 nm wavelength.  相似文献   

20.
T.M. MADELIN AND H.E. JOHNSON. 1992. An aerodynamic particle sizer (APS) that uses laser Doppler velocimetry was used to determine aerodynamic diameters of spores of fungal and thermophilic actinomycete species common in mouldy hay, acrosolized at different humidities and temperatures. Results were compared with those obtained from inertial impaction in a cascade impactor. The APS gave slightly smaller measurements than the cascade impactor. Both methods gave aerodynamic diameters generally slightly smaller than the average spore dimensions observed on cascade impactor slides with a microscope. The latter measurements were less than axial dimensions given in the literature. Brief passage of spores through air at 95% relative humidity (RH) and 38°C, compared with 40% RH and 20°C, caused an immediate increase in their aerodynamic diameter and the breaking of chains of spores. Cultures maintained at 75% RH and aerosolized at 98% RH similarly produced larger spore particles than those passed through dry air. These findings have implications for mould-induced asthma and allergic alveolitis since they relate to physical behaviour of airborne spores and particle deposition sites in the lung.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号