Using a crossover experimental design, we evaluated our earlier findings that exposure to a 30 kV/m, 60 Hz electric field for 12 hours per day, 7 days per week for 6 weeks produced significant changes in the performance rates of social behaviors among young adult male baboons. In the crossover experiment, the former control group was exposed to a 30 kV/m, 60 Hz electric field for 3 weeks. Only an extremely small, incidental magnetic field was generated by the exposure apparatus. We found that electric-field exposure again produced increases in the performance rates that index Passive Affinity, Tension, and Stereotypy. These findings, combined with results from our other electric-field experiments, indicate that exposure to strong electric fields, in the absence of associated magnetic fields, consistently produces effects that are expressed as increases in rates of performance of social behaviors in young adult male baboons.  相似文献   

2.
The rationale for selection of an animal model, the experimental design, and the design and evaluation of an exposure system used in studies of 60-Hz magnetic fields are described. The studies were conceived to assay development of cancer and immune responsiveness in mice exposed to magnetic fields. The exposure system utilized a quadrupole-coil configuration to minimize stray magnetic fields. Four square-wound coil provided a uniform field within a volume occupied by 16 animal cages. The magnetic field had a mean flux density of 2 mT that varied less than +/- 10% within the volume occupied by animals' cages. The flux density decreased to less than 0.1 microT at a distance of 2 m from the coils. In each exposure system 32 animals could be housed in plastic cages.  相似文献   

3.
Recently, it has been reported that exposure to high-strength electric fields can influence electrocardiogram (ECG) patterns, heart rates, and blood pressures in various species of animals. Our studies were designed to evaluate these reported effects and to help clarify some of the disagreement present in the literature. Various cardiovascular variables were measured in Sprague-Dawley rats exposed or sham-exposed to 60-Hz electric fields at 80 or 100 kV/m for periods up to four months. No significant differences in heart rates, ECG patterns, blood pressures, or vascular reactivity were observed between exposed and sham-exposed rats after 8 hours, 40 hours, 1 month, or 4 months of exposure. Blood pressure and heart rate measurements, made during exposure to a 100-kV/m electric field for one hour, revealed no significant differences between exposed and sham-exposed groups. In addition, physiologic reserve capacity, measured in rats subjected to low temperature after exposure to 100 kV/m for one month, showed that electric-field exposure had no significant effect on physiological response to cold stress. Our studies cannot be directly compared to the work of other investigators because of differences in animal species and electric-field characteristics. However, our failure to detect any cardiovascular changes may have been the result of 1) eliminating secondary field effects such as shocks, audible noise, corona, and ozone; 2) minimizing steady-state microcurrents between the mouth of the animal and watering devices; and 3) minimizing electric-field-induced vibration of the electrodes and animal cages.  相似文献   

4.
The design, construction, and results of evaluation of an animal-exposure system for the study of biological effects of extremely low frequency (ELF) magnetic fields are described. The system uses a square coil arrangement based on a modification of the Helmholtz coil. Due to the cubic configuration of this exposure system, horizontal and vertical magnetic fields as high as 0.3 mT can be generated. Circularly polarized magnetic fields can also be generated by changing the current and phase difference between two sets of coils. Tests were made for uniformity of the magnetic field, stray fields, sham-exposure ratio of stray field, changes of temperature and humidity, light intensity and distribution inside the animal-housing space, and noise due to air-conditioning equipment. Variation of the magnetic field was less than 2% inside the animal housing. The stray-field level inside the sham-exposure system is less than 2% of experimental exposure levels. The system can be used for simultaneous exposure of 48 rats (2 to a cage) or 96 mice (4 to a cage). © 1993 Wiley-Liss. Inc.  相似文献   

5.
A system is described that uses an oscillating magnetic field to produce power-frequency electric fields with strengths in excess of those produced in an animal or human standing under a high-voltage electric-power transmission line. In contrast to other types of exposure systems capable of generating fields of this size, no electrodes are placed in the conducting growth media: the possibility of electrode contamination of the exposed suspension is thereby eliminated. Electric fields in the range 0.02–3.5 V/m can be produced in a cell culture with total harmonic distortions less than 1.5%. The magnetic field used to produce electric fields for exposure is largely confined within a closed ferromagnetic circuit, and experimental and control cells are exposed to leakage magnetic flux densities less than 5 μT. The temperatures of the experimental and control cell suspensions are held fixed within ±0.1°C by a water bath. Special chambers were developed to hold cell cultures during exposure and sham exposure. Chinese hamster ovary (CHO) cells incubated in these chambers grew for at least 48 h and had population doubling times of 16–17 h, approximately the same as for CHO cells grown under standard cell-culture conditions.  相似文献   

6.
We consider the possibility that DC magnetic fields can interact in a resonant manner with endogenous AC electric fields in biological systems. Intrinsic electric-field ion cyclotron resonance (ICR) interactions would be more physically credible than models based on external AC magnetic fields and might be expected as an evolutionary response to the long-term constancy of the geomagnetic field. Bioelectromagnetics 17:85–87, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

7.
Abstract

Measurements of extremely low frequency (ELF) magnetic fields were conducted in the environment of commercial laboratory equipment in order to evaluate the possible co-exposure during the experimental processes on cell cultures. Three types of device were evaluated: a cell culture CO2 incubator, a thermostatic water bath and a laboratory shaker table. These devices usually have electric motors, heating wires and electronic control systems, therefore may expose the cell cultures to undesirable ELF stray magnetic fields. Spatial distributions of magnetic field time domain signal waveform and frequency spectral analysis (FFT) were processed. Long- and short-term variation of stray magnetic field was also evaluated under normal use of investigated laboratory devices. The results show that the equipment under test may add a considerable ELF magnetic field to the ambient environmental magnetic field or to the intentional exposure to ELF, RF or other physical/chemical agents. The maximum stray magnetic fields were higher than 3?µT, 20?µT and 75?µT in the CO2 incubator, in water bath and on the laboratory shaker table, respectively, with high variation of spatial distribution and time domain. Our investigation emphasizes possible confounding factors conducting cell culture studies related to low-level ELF-EMF exposure due to the existing stray magnetic fields in the ambient environment of laboratory equipment.  相似文献   

8.
A system is described that is capable of producing extremely low frequency (ELF) magnetic fields for relatively short-term exposure of cultured mammalian cells. The system utilizes a ferromagnetic core to contain and direct the magnetic field of a 1,000 turn solenoidal coil and can produce a range of flux densities and induced electric fields much higher than those produced by Helmholtz coils. The system can generate magnetic fields from the microtesla (μT) range up to 0.14 T with induced electric field strengths on the order of 1.0 V/m. The induced electric field can be accurately varied by changing the sample chamber configuration without changing the exposure magnetic field. This gives the system the ability to separate the bioeffects of magnetic and induced electric fields. In the frequency range of 4–100 Hz and magnetic flux density range of 0.005–0.14 T, the maximum total harmonic distortion of the induced electric field is typically less than 1.0%. The temperature of the samples is held constant to within 0.4°C by constant perfusion of warmed culture medium through the sample chamber. © 1993 Wiley-Liss, Inc.  相似文献   

9.
Rats exposed for 3 weeks to uniform 60-Hz electric fields of 39 kV/m (effective field strength) failed to show normal pineal gland circadian rhythms in serotonin N-acetyl transferase activity and melatonin concentrations. The time required for recovery of the melatonin rhythm after cessation of field exposure was determined to be less than 3 days. The rapid recovery suggests that the overall metabolic competence of the pineal is not permanently compromised by electric-field exposure, and that the circadian rhythm effect may be neuronally mediated.  相似文献   

10.
Magnetoreception is the ability of organisms to perceive magnetic fields in the surrounding environment and changes in its properties such as field direction, intensity and gradient, where the effect on organisms can manifest as an array of reactions. As the magnetic sense is found in many taxa, both evolutionarily young and old, it can be assumed that magnetoreception came into existence as one of the first sensory systems. Many studies on the effect of magnetic fields on fishes have considered both fishes that migrate for long distances and those that are more or less sedentary. Research has focused on tracing the perception of the geomagnetic field by fishes and understanding magnetic fields that are smaller and larger than the ambient Earth's geomagnetic field. The question of the effect of magnetic fields of values higher than the Earth's is gaining importance with the increasing effect of anthropogenic magnetic and electromagnetic fields in aquatic ecosystems. This review draws together the results of studies on the effect and reception of natural and human-generated magnetic fields on fishes at various stages of ontogeny, chronologically arranged from gametes, through embryonic development, embryonic and larval motor function, directional reactions of embryos and larvae, orientation of fishes, to the mechanisms of magnetic field reception. The present state of knowledge indicates a common nature of effect on various ontogenetic stages of fishes. However, understanding of the mechanisms of magnetic sense in fishes and its relevance for ecological outcomes highlights that further progress requires more detailed research.  相似文献   

11.
For more than a decade, Midwest Research Institute (MRI) has investigated the effects of exposure to 60 Hz electric and magnetic fields (EMF) on human physiology, performance, and biochemistry. This accumulated experience, new research directions, and limited resources made it important to design more comprehensive and operationally cost-effective exposure facilities. Here we describe the new, integrated laboratory exposure test facilities recently constructed at MRI and present data on relevant characteristics of the exposure systems. Concentric coil systems were developed to generate uniform magnetic fields within the three new exposure rooms, with rapid cancellation of the field to ambient levels in the rest of the laboratory. Control systems are fully automated, computer-based, and independent. These provide the operational flexibility needed to present fields of different magnitudes, frequencies, and polarization. The local geomagnetic field can be modulated and/or canceled, and both AC and DC fields can be presented in various combinations. Capabilities for conducting double-blind experiments with true active-sham exposure conditions were implemented using bifilar windings and applying current flow in the opposite direction for each wire in a pair. The new facilities provide a comprehensive capability for laboratory-based human research on the potential effects of exposure to AC and DC magnetic fields.  相似文献   

12.
In most previous 50/60-Hz experiments, subjects were placed in a dielectric cage and the electric field was applied from outside the cage. Although the field outside the cage was kept uniform in space and constant in time, the field inside the cage undergoes undesirable temporal and spatial variations. We have designed an electric-field exposure system that overcomes these problems by having a metal cage constitute a part of the field generating electrodes. The uniformity along the diameter of the cages for mice and cats are more than 84.2% and 74.3%, respectively.  相似文献   

13.
Much of the research and reviews on extremely low frequency (ELF) electric and magnetic fields (EMFs) have focused on magnetic rather than electric fields. Some have considered such focus to be inappropriate and have argued that electric fields should be part of both epidemiologic and laboratory work. This paper fills the gap by systematically and critically reviewing electric‐fields literature and by comparing overall strength of evidence for electric versus magnetic fields. The review of possible mechanisms does not provide any specific basis for focusing on electric fields. While laboratory studies of electric fields are few, they do not indicate that electric fields should be the exposure of interest. The existing epidemiology on residential electric‐field exposures and appliance use does not support the conclusion of adverse health effects from electric‐field exposure. Workers in close proximity to high‐voltage transmission lines or substation equipment can be exposed to high electric fields. While there are sporadic reports of increase in cancer in some occupational studies, these are inconsistent and fraught with methodologic problems. Overall, there seems little basis to suppose there might be a risk for electric fields, and, in contrast to magnetic fields, and with a possible exception of occupational epidemiology, there seems little basis for continued research into electric fields. Bioelectromagnetics 31:89–101, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
A magnetic field exposure laboratory has been constructed to support National Toxicology Program studies for the evaluation of the toxicity and carcinogenicity of pure, linearly polarized, 60 Hz magnetic fields in rodents. This dual corridor, controlled access facility can support the simultaneous exposure of 1200 rats and 1200 mice. The facility contains fully redundant electrical and environmental control systems and was constructed using non‐metallic materials to maintain low levels of background (ambient), stray, and cross‐talk magnetic fields. The exposure module design provides for large uniform exposure volumes with good control of stray and cross‐talk fields, while allowing the use of roll‐around cage racks for simplified animal husbandry. Stray fields and cross‐talk have been further reduced by the inclusion of “steering coils” in each exposure module. Ambient 60 Hz fields (less cross‐talk) in all exposure rooms are <0.1 μT (1 mG), and static magnetic fields have been mapped extensively. Magnetic field strength, waveform, temperature, relative humidity, light intensity, noise level, vibration, and air flow in all animal holding areas are tightly regulated, and are monitored continuously during all studies. Field uniformity in the animal exposure volumes is better than ±10%; a systematic program of cage, rack, and room rotation controls for possible positional effects within the exposure system. Magnetic fields are turned on and off over multiple cycles to prevent the induction of transients associated with abrupt field level changes. Total harmonic distortion is <3% at all field strengths. The facility has been used to study magnetic field bioeffects in rodent model systems in experiments ranging in duration from 8 weeks to 2 years. Bioelectromagnetics 20:13–23, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

15.
Magnetic field systems were added to existing electric field exposure apparatuses for exposing cell suspensions in vitro and small animals in vivo. Two horizontally oriented, rectangular coils, stacked one directly above the other, have opposite electric currents. This configuration minimizes leakage fields and allows sham- and field-exposure systems to be placed in the same room or incubator. For the in vitro system, copper plates formed the loop-pair, with up to 900 A supplied by a 180:1 transformer. Electric fields were supplied via electrodes at the ends of cell-culture tubes, eight of which can be accommodated by each exposure system. Two complete systems are situated in an incubator to allow simultaneous sham and field exposure up to 1 mT. For the in vivo system, four pairs of 0.8 x 2.7-m coils made of copper bus bar are employed. This arrangement is energized from the power grid via a 30:1 transformer; horizontal magnetic flux densities up to 1 mT can be generated. Pairs of electrode plates spaced 30.5 cm apart provide electric field exposure of up to 130 kV/m. Four systems with a capacity of 48 rats each are located in one room. For both the in vitro and in vivo systems, magnetic exposure fields are uniform to within +/- 2.5%, and sham levels are at least 2,500-fold lower than exposure levels. Potential confounding factors, such as heating and vibration, were examined and found to be minimal.  相似文献   

16.
We describe a new system for exposing cultured biological cells that have been plated on coverslips to strong electrostatic fields at magnitudes greater than 10(3) V/cm. Techniques are described that make use of mineral oil to render insignificant electrical conduction currents (total leakage current is less than 1.0 nA or less than 0.1 nA/coverslip), joule heating (less than 10(-6) W), or current-induced magnetic fields (less than 10(-13) T) in regions inhabited by cells. The mineral oil also eliminates a reduction in the strength of the applied field, which otherwise can occur from increased electrode-to-medium impedance at the site of application. Thus the applied field is reliably specified in the vicinity of a cell membrane. Control and electrostatic field chambers are housed in a grounded metal incubator. Cylindrical mu-metal shields can be used to reduce background magnetic fields in each chamber from 40 microT static and approximately 1 microT ac to, respectively, less than 3 microT static and approximately 100 nT ac. Contamination of cells by impurity atoms that may leach from electrodes was measured by atomic-absorption spectrophotometry and found to be negligible. Stray magnetic- and electric-field components within the incubator were measured, as were background fields around the laboratory.  相似文献   

17.
This study tests the capacity of 50 Hz magnetic and electric fields to stimulate neurite outgrowth in PC-12D cells, a cell line which originated from a pheochromocytoma in rat adrenal medulla. The cells were plated on collagen-coated, plastic petri dishes and exposed to sinusoidal 50 Hz magnetic fields for 22 h in a 5% CO2 incubator at 37°C. Two 1,000 turn coils, 20 cm in diameter, were assembled in a Helmholtz configuration to generate a magnetic field in a vertical orientation, thereby inducing a companion electric field in the dish with intensity proportional to radius. A magnetic-field shield housed the control samples in the same incubator. Total cells and number of cells with neurites at least as long as one cell diameter or having a growth cone were counted within a radius of 0.3 cm of the dish center and within an annulus of 1.7–1.8 cm radii in 60 mm dishes, at 3.6 cm radius in 100 mm dishes, and between 1.9 and 2.1 cm radii in the outer well of organ culture dishes, which are physically separated into two concentric wells. Sham exposure demonstrated no difference in percentage of cells with neurites between the exposed and control locations in the incubator. Exposures were done at 4.0. 8.9, 22, 29, 40, 120, 236, and 400 milliGauss (mG). At dish radii of 1.7–1.8 cm in the 60 mm dishes these magnetic flux densities induced electric fields of 1.1, 2.5, 5.9, 8.1, 11, 33, 65, and 110 μV/m, respectively, while within a radius of 0.3 cm, the induced electric fields were less than 0.2, 0.4, 1.0, 1.5, 1.9, 6.0, 11, and 19 μV/m, respectively. For other dishes, the larger radii produced proportionally larger induced electric fields. At each field strength, there were two control dishes and four to nine exposed dishes: 100 or more cells were counted at each location on the dishes. The results demonstrate that magnetic fields stimulate neurite outgrowth in a flux-density-dependent manner between 22 and 40 mG, reaching an apparent stimulation plateau between 40 and 400 mG; no effects were seen at 8.9 mG or lower. There was no apparent neurite stimulation due to the electric field. Although relatively low intensity (?22mG) magnetic fields alone can stimulate a morphological response in a cell which is normally stimulated by nerve growth factor molecules binding to membrane receptors, the chemical basis of this response is unknown. © 1993 Wiley-Liss. Inc.  相似文献   

18.
Transient effects of 100-kV/m extremely low frequency electric fields were studied in the white footed deermouse, Peromyscus leucopus. Gross motor activity, carbon dioxide production, oxygen consumption, and core body temperature were monitored before, during, and after intermittent field exposures (four hour-long exposures, at one-hour intervals). Thirty-four mice were exposed in cages with plastic floors floating above ground potential, and 21 mice were exposed in cages with grounded metal floor plates. The first field exposure produced an immediate, transient increase of activity and gas measures during the inactive phase of the circadian cycle. All measures returned to baseline levels before the second exposure and were not significantly changed throughout the remainder of the exposures. The rapid habituation of field-induced arousal suggests that significant metabolic changes will not be measured in experiments in which the interval between exposure and measurement is greater than two hours.  相似文献   

19.
Sixteen multiparous nonpregnant lactating Holstein cows (each weighing 662 ± 65 kg in 150.4 ±40 day of lactation) were confined to wooden metabolic cages with 12:12 h light:dark cycle during the experiment. The cows were divided into two sequences of eight cows each and exposed to electric and magnetic fields (EMF) in an exposure chamber. This chamber produced a vertical electric field of 10 kV/m and a uniform horizontal magnetic field of 30 μT at 60 Hz. One sequence was exposed for three estrous cycles of 24 to 27 days. During the first estrous cycle, the electric and magnetic fields were off; during the second estrous cycle, they were on; and during the third estrous cycle, they were off. The second sequence was also exposed for three 24 to 26 days estrous cycles, but the exposure to the fields was reversed (first estrous cycle, on; second estrous cycle, off; third estrous cycle, on). The length of each exposure period (21 to 27 days) varied according to the estrous cycle length. No differences were detected in plasma progesterone concentrations and area under the progesterone curve during estrous cycles between EMF nonexposed and exposed periods (2.28 ±0.17 and 2.25 ± 0.17; and 24.5 ± 1.9 vs. 26.4 ± 1.9 ng/ml, respectively). However, estrous cycle length, determined by the presence of a functional corpus luteum detected by concentrations of progesterone equal to or more than 1 ng/ml plasma, was shorter in nonexposed cows than when they were exposed to EMF (22.0 ± 0.9 vs. 25.3 ± 1.4 days). Bioelectromagnetics 19:438–443, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

20.
We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.  相似文献   