1.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

2.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

3.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C(18) bioanalytical column at a flow rate of 1 ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20 microg/ml bivalirudin in plasma, with a detection limit of 1 microg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).  相似文献   

5.
Indomethacin (IND) is the drug of choice for the closure of a patent ductus arteriosus (PDA) in neonates. This paper describes a simple, sensitive, accurate and precise microscale HPLC method suitable for the analysis of IND in plasma of premature neonates. Samples were prepared by plasma protein precipitation with acetonitrile containing the methyl ester of IND as the internal standard (IS). Chromatography was performed on a Hypersil C(18) column. The mobile phase of methanol, water and orthophosphoric acid (70:29.5:0.5, v/v, respectively), was delivered at 1.5 mL/min and monitored at 270 nm. IND and the IS were eluted at 2.9 and 4.3 min, respectively. Calibrations were linear (r>0.999) from 25 to 2500 microg/L. The inter- and intra-day assay imprecision was less than 4.3 % at 400-2000 microg/L, and less than 22.1% at 35 microg/L. Inaccuracy ranged from -6.0% to +1.0% from 35 to 2000 microg/L. The absolute recovery of IND over this range was 93.0-113.3%. The IS was stable for at least 36 h when added to plasma at ambient temperature. This method is suitable for pharmacokinetic studies of IND and has potential for monitoring therapy in infants with PDA when a target therapeutic range for IND has been validated.  相似文献   

6.
We have previously reported an iothalamate assay for the assessment of the glomerular filtration rate (GFR) that required a long column equilibration time and 22 min run time per sample. We now report a simpler assay that requires a run time of only 5.5 min and is more precise and accurate than the earlier technique. The mobile phase consisted of methanol-acetonitrile-50 mM sodium monobasic phosphate (10:5:85, v/v) at pH 4.4, pumped at a rate of 1.5 ml/min on a C(18) reversed-phase column. Samples of plasma and urine were deproteinized with 1 volume of 4% perchloric acid or 9 volumes of 2% perchloric acid, respectively. No internal standard was used. The diode array detection system collected absorbance at 240 nm and the peak height areas of iothalamate were determined. The iothalamate peak appeared at 3.5 min. Detector response was linear over the range tested (10-2000 microg/ml). Within-run precision was <3% for both plasma and urine and accuracy was 96-102%. Between-day precision for plasma and urine analyses were <7%. The recovery of iothalamate in urine and plasma were 102% and 91%, respectively. There was excellent thermal and pH stability of iothalamate. No interference was found with para-amino hippuric acid (PAH) or N-acetyl PAH, which can be simultaneously assayed, if desired.  相似文献   

7.
A simple and specific HPLC assay for simultaneous determination of two major active components (-) epigallocatechin-3-gallate (EGCG), and (-) epicatechin-3-gallate (ECG) of tea polyphenols (TP) in rat plasma was developed and validated. Following addition of resorcinol as internal standard (IS) the analytes were isolated from rat plasma by liquid-liquid extraction with ethyl acetate. The chromatographic separation was achieved on a reversed-phase C18 column using an isocratic mobile phase consisting of 0.1% citric acid+CH(3)CN (86:14, v/v) running at flow rate of 1.5 mL/min. The effluent was monitored at a wavelength of 280 nm. EGCG, ECG and IS were well separated from each other and free from interference from blank plasma and other components in TP as well as metabolites post-dosing. The calibration curve was constructed by plotting peak area ratio of analytes to IS vs. concentration. The method showed good linearity over range of 0.5-300 microg/mL for EGCG and 0.1-60 microg/mL for ECG (r>0.999). The intra- and inter-day precision (R.S.D.) was better than 6 and 12%, respectively. Assay accuracy was better than 94.78% for both compounds. Extraction recovery at QC samples was between 85.73 and 91.93% for EGCG and 79.08 and 86.51% for ECG. The developed method was successfully used to simultaneously measure plasma concentrations of EGCG and ECG after intravenous administration of TP to rats and yielded two typical biexponential decay concentration-time curves.  相似文献   

8.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

9.
A SPE-HPLC method was developed and validated for the simultaneous determination of flavonols, isoquercitrin (1), hibifolin (2), myricetin (3), quercetin-3'-O-d-glucoside (4) and quercetin (5) in rat plasma and urine after oral administration of the total flavonoids from Abelmoschus manihot (TFA). The astragalin (6) and kaempferol (7) were used as internal standards (IS). Plasma and urine samples were pretreated by solid-phase extraction using Winchem C(18) reversed-phase cartridges. Analysis of the plasma and urinary extract was performed on YMC-Pack ODS-A C(18) and Thermo ODS-2HYEPRSIL C(18) reversed-phase column, respectively and a mobile phase of acetonitrile-0.1% phosphoric acid was employed. HPLC analysis was conducted with different elution gradients. The flow rate was 1.0 mL/min and the detection wavelength was set at 370 nm. Calibration ranges in plasma for flavonols 2-5 were at 0.011-2.220, 0.014-2.856, 0.022-4.320, and 0.028-5.600 microg/mL, respectively. In urine calibration ranges for flavonols 1, 2, 4 and 5 were at 2.00-16.00, 8.56-102.72, 2.70-21.60, and 3.00-24.00 microg/mL, respectively. The RSD of intra- and inter-day was less than 5.40% and 4.89% in plasma, and less than 3.96% and 6.85% in urine for all the analyses. A preliminary experiment to investigate the plasma concentration and urinary excretion of the flavonols after oral administration of TFA to rats demonstrated that the present method was suitable for determining the flavonols in rat plasma and urine.  相似文献   

10.
A fast and selective HPLC-MS-MS method was established to determine L-threonate in human plasma and urine. Plasma and urine samples were extracted by protein precipitation and diluted with water, then chromatographed on an YMC J'Sphere C(18) column with methanol-acetonitrile-10mM ammonium acetate (20:5:75, v/v) as mobile phase, and at a flow rate of 0.2 ml/min. Detection was performed on a triple-quadrupole tandem mass spectrometer using negative electrospray ionization (ESI). Multiple reactions monitoring (MRM) was used and L-threonate was quantified by monitoring the ion transition of m/z 134.5-->74.7. The linear calibration curves of L-threonate in plasma and urine were obtained over the concentration range of 0.25-50 microg/ml and 2.5-500 microg/ml, respectively. Lower limit of quantitation was 0.25 and 2.5 microg/ml, respectively. Accuracy was within 85-115%, and intra- and inter-batch precision (R.S.D.%) were within +/-15%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of L-threonate in Chinese healthy subjects.  相似文献   

11.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

12.
Moxifloxacin (1-cyclopropyl-6-fluoro-1,4-dihydro-8-methoxy-7-[(4aS,7aS)-octahydro-6H-pyrrolo-[3,4-b]pyridin-6-yl]-4-oxo-3-quinolinecarboxylic acid hydrochloride) is new, fourth generation fluoroquinolone with broaden spectrum of antibacterial activity. In the present work simple and rapid RP-HPLC method for the direct determination of moxifloxacin in human plasma is described. Separation of moxifloxacin from plasma components was achieved on Supelco LC-Hisep shielded hydrophobic phase column. The mobile phase consisted of acetonitrile and 0.25mol/dm(3) Na(3)PO(4) (pH 3) in a volume percent ratio (5:95, v/v) and was delivered at a rate of 1mL/min. Fluorescence detection was employed with excitation at 290nm and emission at 500nm. Ofloxacin was used as internal standard and sodium dodecylsulfate solution was used as a displacing agent. Sample preparation was simplified and involved only addition of displacing agent and internal standard and dilution with water. The separation conditions were optimized by the response surface method in two factor space, i.e. the dependence of the retention time on volume percent of acetonitrile and on pH of aqueous phase was optimized. The method was fully validated and validation parameters were: linearity range 3-1300microg/L; correlation coefficient, 0.99986; mean recovery, 92.5%; limit of quantification, 3.0microg/L and limit of detection, 1.0microg/L. Method was applied for the determination of moxifloxacin in human plasma after single or repeated oral doses of 400mg Avelox tablets. The proposed method proved to be rapid and accurate and can be successfully used in pharmacokinetic studies and routine clinical practice.  相似文献   

13.
A high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) method was established for the determination of gambogic acid (GA) in human plasma using ursolic acid as the internal standard (I.S.). Plasma samples were extracted with ethyl acetate and separated on a Hanbon Lichrospher 5-C18 column with a mobile phase of acetonitrile-tetrahydrofuran-water (70:23:7, v/v). Gambogic acid was determined by using atmospheric pressure chemical ionization (APCI) in a single quadrupole mass spectrometer. HPLC-APCI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M-H](-)m/z 627.4 for gambogic acid and [M-H](-)m/z 455.4 for the I.S. Calibration curve was linear over the range of 3.108-4144 microg/L. The lower limit of quantification was 3.108 microg/L. The intra- and inter-run precisions were less than 12.3 and 14.1%, respectively. The method has been successfully applied to study the pharmacokinetics of gambogic acid in patients with malignant tumour.  相似文献   

14.
Amphetamine-type stimulants (ATS) are a group of chiral amine drugs which are commonly abused for their sympathomimetic and stimulant properties. ATS are extensively metabolised by hepatic cytochrome P450 enzymes. As metabolism of ATS has been shown to be highly stereospecific, stereoselective analytical methods are essential for the quantitative determination of ATS concentrations for both in vivo and in vitro studies of ATS metabolism. This paper describes a new stereoselective method for the simultaneous determination of amphetamine (AM), methamphetamine (MA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), 4-hydroxy-3-methoxymethamphetamine (HMMA), 4-hydroxy-3-methoxyamphetamine (HMA), 3,4-hydroxymethamphetamine (HHMA) and 3,4-hydroxyamphetamine (HHA) in human urine samples validated according to the United States Food and Drug Administration guidelines. In this method, analytes are simultaneously extracted and derivatized with R-(-)-α-methoxy-α-(trifluoromethyl)phenylacetyl chloride (R-MTPCl) as the chiral derivatization reagent. Following this, the analytes were subjected to a second derivatization with N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) which targets the hydroxyl groups present in HMMA, HMA, HHMA and HHA. The derivatized analytes were separated and quantified using gas chromatography-mass spectrometry (GC-MS). The method was evaluated according to the established guidelines for specificity, linearity, precision, accuracy, recovery and stability using a five-day protocol. Intra-day precision ranged from 0.89 to 11.23% RSD whereas inter-day precision was between 1.03 and 12.95% RSD. Accuracy values for the analytes ranged from -5.29% to 13.75%. Limits of quantitation were 10 μg/L for AM, MA, MDMA, HMA and HMMA and 2μg/L for MDA, HMA and HHA. Recoveries and stability values were also within accepted values. The method was applied to authentic ATS-positive samples.  相似文献   

15.
We have developed a sensitive and reproducible high performance liquid chromatography (HPLC)-UV method for the quantification of the p38 MAPkinase inhibitor SB202190 in serum, kidney homogenates and urine samples. Liquid-liquid extraction of SB202190 from the samples was performed using diethylether after adding a derivative of SB202190 as internal standard (I.S.). Chromatography was carried out using a C8 reversed-phase column with an isocratic mobile phase consisting of acetonitrile-water-trifluoroacetic acid (30:70:0.1, v/v/v; pH 2.0). Both drug and I.S. were measured at 350 nm and eluted at 5.0 and 10.6 min, respectively. Peak-height ratios of the drug and the I.S. were used for the quantification of SB202190 from the different matrixes. The limit of quantitation of SB202190 in serum, kidney and urine were 0.25 microg/ml, 1 microg/g and 1 microg/ml, respectively. The average recoveries were 74, 75 and 92% in serum, kidney and urine, respectively. The intra- and inter-day precision (% CV) and accuracy (% bias) were below 15% for all concentrations. The method was successfully applied for a pharmacokinetic study of SB202190 in rats.  相似文献   

16.
A simple high-performance liquid chromatographic (HPLC) method was developed for the assay of total and free mycophenolic acid (MPA) in human plasma. Prior to analysis, total mycophenolic acid was extracted by protein precipitation and free drug was isolated from plasma samples using ultrafiltration. The extracts were injected onto a Kromasil C8 column at 30 degrees C with excitation and emission wavelengths set at 342 and 425 nm, respectively. The mobile phase was consisted of acetonitrile-32 mM glycine buffer, pH 9.2 (20:80, v/v), at a flow rate of 1.0 ml/min. The method was found to be linear over the concentration range investigated, 0.05-40 mg/l for total mycophenolic acid (r>0.999) and 5-1000 microg/l (r>0.99) for free drug. The percentage error of the analytical method was below 10.9%. The intra- and inter-day reproducibility was adequate with the coefficients of variation of 8.28% or below. The run time were 4 and 6 min for free and total MPA, respectively. The method thus can be effectively applied to measure mycophenolic acid concentrations in clinical samples.  相似文献   

17.
A sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) assay with on-line extraction was developed for quantifying ertapenem in human cerebrospinal fluid (CSF). This assay is at least five times more sensitive than previously published ertapenem methods with a lower limit of quantitation at 0.025 microg/ml. In this assay, a CSF sample is extracted on-line using a RP extraction column and an aqueous acidic mobile phase (0.1% formic acid) to wash away polar endogenous materials, while ertapenem is retained on the column. Ertapenem is then back-flushed off the extraction column and directed to a RP analytical column using an acidic mobile phase with an organic modifier (acetonitrile/0.1% formic acid, 15:85 (v/v)) and detected using UV absorbance. The acidic mobile phase provided a sharper chromatographic peak and on-line extraction allowed large injection volumes (> or = 150 microl) of buffered CSF to be injected without compromising column integrity. These assay conditions were necessary to quantify ertapenem at levels expected to be found in human CSF (< 0.05 microg/ml). The method was successfully validated and implemented for a clinical study: intraday precision and accuracy of the CSF assay for calibration standards (0.025-10 microg/ml) and quality control samples (0.1, 0.5, and 2.5 microg/ml) were < 6.2% coefficient of variation and 96.8-104.0% of nominal concentration, respectively.  相似文献   

18.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

19.
A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.  相似文献   

20.
A fast, simple, and a reliable high-performance liquid chromatography linked with electrochemical detector (HPLC-ECD) method for the assessment of lipoic acid (LA) and dihydrolipoic acid (DHLA) in plasma was developed using naproxen sodium as an internal standard (IS) and validated according to standard guidelines. Extraction of both analytes and IS from plasma (250 μl) was carried out with a single step liquid-liquid extraction applying dichloromethane. The separated organic layer was dried under stream of nitrogen at 40°C and the residue was reconstituted with the mobile phase. Complete separation of both compounds and IS at 30°C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 9 min using acetonitrile: 0.05 M phosphate buffer (pH 2.4 adjusted with phosphoric acid) (52:48, v/v) as a mobile phase pumped at flow rate of 1.5 ml min(-1) using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification for lipoic acid were 500 pg/ml and 3 ng/ml, and for dihydrolipoic acid were 3 ng/ml and 10 ng/ml, respectively. The absolute recoveries of lipoic acid and dihydrolipoic acid determined on three nominal concentrations were in the range of 93.40-97.06, and 93.00-97.10, respectively. Similarly coefficient of variations (% CV) for both intra-day and inter-day were between 0.829 and 3.097% for lipoic acid and between 1.620 and 5.681% for dihydrolipoic acid, respectively. This validated method was applied for the analysis of lipoic acid/dihydrolipoic acid in the plasma of human volunteers and will be used for the quantification of these compounds in patients with oxidative stress induced pathologies.  相似文献   