共查询到20条相似文献,搜索用时 0 毫秒
1.
Specific adhesion of vesicles monitored by scanning force microscopy and quartz crystal microbalance 下载免费PDF全文
The specific adhesion of unilamellar vesicles with an average diameter of 100 nm on functionalized surfaces mediated by molecular recognition was investigated in detail. Two complementary techniques, scanning force microscopy (SFM) and quartz crystal microbalance (QCM) were used to study adhesion of liposomes consisting of 1, 2-dipalmitoyl-sn-glycero-3-phosphocholine and varying concentrations of N-((6-biotinoyl)amino)hexanoyl)-1, 2-dihexadecanoyl-sn-glycero-3-phosphoethanolamine (biotin-X-DHPE). Monitoring the adhesion of the receptor-doped vesicles to avidin-coated gold surfaces by QCM (f(0) = 5 MHz) revealed an increased shift in resonance frequency with increasing biotin concentration up to 10 mol% biotin-X-DHPE. To address the question of how the morphology of the liposomes changes upon adhesion and how that contributes to the resonator's frequency response, we performed a detailed analysis of the liposome morphology by SFM. We found that, with increasing biotin-concentration, the height of the liposomes decreases considerably up to the point where vesicle rupture occurs. Thus, we conclude that the unexpected high frequency shifts of the quartz crystal (>500 Hz) can be attributed to a firm attachment of the spread bilayers, in which the number of contacts is responsible for the signal. These findings are compared with one of our recent studies on cell adhesion monitored by QCM. 相似文献
2.
《生物化学与生物物理学报:生物膜》2022,1864(10):183976
The influence and interaction of the ionizable amphiphilic drug amitriptyline hydrochloride (AMT) on a 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) phospholipid bilayer supported on a silica surface have been investigated using a combination of neutron reflectometry and quartz crystal microbalance with dissipation monitoring. Adding AMT solutions with concentrations 3, 12, and 50 mM leaves the lipid bilayer mainly intact and we observe most of the AMT molecules attached to the head-group region of the outer bilayer leaflet. Virtually no AMT penetrates into the hydrophilic head-group region of the inner leaflet close to the silica surface. By adding 200 mM AMT solution, the lipid bilayer dissolved entirely, indicating a threshold concentration for the solubilization of the bilayer by AMT. The observed threshold concentration is consistent with the observation that various bilayer structures abruptly transform into mixed AMT-DOPC micelles beyond a certain AMT-DOPC composition. Based on our experimental observations, we suggest that the penetration of drug into the phospholipid bilayer, and subsequent solubilization of the membrane, follows a two-step mechanism with the outer leaflet being removed prior to the inner leaflet. 相似文献
3.
Schenkman JB Jansson I Lvov Y Rusling JF Boussaad S Tao NJ 《Archives of biochemistry and biophysics》2001,385(1):78-87
Quartz crystal microbalance (QCM) resonance measurements were used to examine the surface charge characteristics of cytochrome P450 forms and the influence of charge on the docking of redox partners like cytochrome b5. The distal surface of cytochrome P450 (CYP)101 (pI = 4.5), relative to the heme, is fairly anionic, as is the proximal surface. The latter, however, also has two cationic clusters. A considerably greater extent of CYP101 binding was seen to the cationic, polyethylene-surfaced resonators. CYP2B4 (pI = 8.5) preferentially bound to the polyanionic, polystyrene sulfonate-surfaced resonators. Cytochrome b5 is an acidic protein that had a preferential binding to the poly(ethyleneimine (PEI)-surfaced resonators. When binding to CYP2B4-surfaced films, cytochrome b5 preferentially bound to those cytochrome P450 molecules that were adsorbed to cationic (PEI) films. It is suggested that adsorption of CYP2B4 to an anionic poly(styrenesulfonate) (PSS) surface is with cationic clusters that include the cytochrome b5 docking domain. This diminishes the extent of docking of the cytochrome b5. In contrast, when CYP2B4 is adsorbed to a cationic film the proximal surface with the cytochrome b5-docking site is available for cytochrome b5 binding. A film of the polycation PEI was adsorbed to the silver QCM surface. It formed polymer islands when viewed with atomic force microscopy. Polyanionic PSS was adsorbed intermittently with the PEI. By the third and fourth layer of polyions the polymer islands were essentially merged and protein adsorption as a fourth or fifth layer formed a nearly continuous film. CYP101 was seen to adsorb as globules with a molecular diameter of about 10 nm. CYP2B4 adsorbed to the polyionic films had a slightly elliptical globular shape, also with a molecular diameter of about 10 nm. 相似文献
4.
The real-time monitoring of the agglutination process of human hepatic normal cells (L-02) at the quartz crystal microbalance (QCM) gold (Au) electrode was performed. Two lectins, concanavalin A (Con A) and wheat germ agglutinin (WGA), induced the cell agglutination, resulting in the different Δf0 and ΔR1 responses from those caused by the normal cell attachment and growth. The cell-Con A-cell aggregates had higher affinity for the Au substrate due to the excellent adsorption ability of Con A, which was revealed by increased Δf0 and ΔR1 shifts and the obvious mass effect of QCM. In contrast, the lower adsorption ability of cell-WGA-cell aggregates was related to the same characteristic of WGA, presenting the decreased Δf0 and ΔR1 responses and the time-extended adhesion phase. Parallel microscopic observation experiments were also carried out and exhibited comparable results. The Δf0 responses during the processes of cell growth and cell agglutination were analyzed using the equations Δf0=a0+a1e-t/τ1+a2e-t/τ2+a3e-t/τ3 and Δf0=a0+a1e-t/τ1+a2e-t/τ2, respectively. Furthermore, the current work proved that the QCM measurement technique based on cell agglutination was useful for discriminating hepatic normal cells (L-02) and hepatic cancer cells (Bel7402). 相似文献
5.
A piezoelectric affinity sensor has been developed to detect distinctive antigens of the human cytomegalovirus. Either the specific antibodies or the antigen were immobilized on the gold electrode. To develop a rapid immunoassay, various assay formats were tested in relation with the different antigen composition. First, a direct assay was carried out immobilizing the specific antibody on the crystal surface by passive adsorption. Next, Protein A, thiol/poly L-lysine mixed self-assembled monolayers were tested as methods of gold modification. A competitive format was exploited by immobilization of the antigen onto the crystal activated by SAM and poly L-lysine. This procedure yielded a preliminary calibration curve. A linear range between 2.5 and 5 μg/ml of gB epitope in solution and a detection limit of 1 μg/ml were measured. 相似文献
6.
Lin L Zhao H Li J Tang J Duan M Jiang L 《Biochemical and biophysical research communications》2000,274(3):817-820
Colloidal Au is reported for enhancement the immobilization capacity and ultimately detection limit of DNA using quartz crystal microbalance (QCM). Immobilization of approximately 12 nm-diameter colloidal Au on to an Au-coated QCM resulted in an easier attachment of oligonucleotide, with a mercaptohexyl group at the 5'-phosphate end and an increased capacity for nucleic acid detection. DNA immobilization and hybridization was monitored from QCM frequency changes. Hybridization was induced by exposure of the DNA-containing films to complementary DNA in solution. A much higher sensitivity was obtained for the analyte. The Au nanoparticle films on the Au plate provide a novel means for the fabrication of DNA sensor. 相似文献
7.
A biofilm reactor was constructed to monitor the long-term growth and removal of biofilms as monitored by the use of a quartz crystal microbalance (QCM) and a novel optical method. The optical method measures the reflectance of white light off the surface of the quartz crystal microbalance electrode (gold) for determination of the biofilm thickness. Biofilm growth of Pseudomonas aeruginosa (PA) on the surface was used as a model system. Bioreactors were monitored for over 6 days. Expressing the QCM data as the ratio of changes in resistance to changes in frequency (DeltaR/Deltaf) facilitated the comparison of individual biofilm reactor runs. The various stages of biofilm growth and adaptation to low nutrients showed consistent characteristic changes in the DeltaR/Deltaf ratio, a parameter that reflects changes in the viscoelastic properties of the biofilm. The utility of white light reflectance for thickness measurements was shown for those stages of biofilm growth when the solution was not turbid due to high numbers of unattached cells. The thickness of the biofilms after 6 days ranged from 48 mum to 68 mum. Removal of the biofilm by a disinfectant (chlorine) was also measured in real time. The combination of QCM and reflectance allowed us to monitor in real time changes in the viscoelastic properties and thickness of biofilms over long periods of time. 相似文献
8.
Microbial biofilm formation can be influenced by many physiological and genetic factors. The conventional microtiter plate assay provides useful but limited information about biofilm formation. With the fast expansion of the biofilm research field, there are urgent needs for more informative techniques to quantify the major parameters of a biofilm, such as adhesive strength and total biomass. It would be even more ideal if these measurements could be conducted in a real-time, non-invasive manner. In this study, we used quartz crystal microbalance (QCM) and microjet impingement (MJI) to measure total biomass and adhesive strength, respectively, of S. mutans biofilms formed under different sucrose concentrations. In conjunction with confocal laser scanning microscopy (CLSM) and the COMSTAT software, we show that sucrose concentration affects the biofilm strength, total biomass, and architecture in both qualitative and quantitative manners. Our data correlate well with previous observations about the effect of sucrose on the adherence of S. mutans to the tooth surface, and demonstrate that QCM is a useful tool for studying the kinetics of biofilm formation in real time and that MJI is a sensitive, easy-to-use device to measure the adhesive strength of a biofilm. 相似文献
9.
Molecular imprinted polymers (MIP) as a recognition element for sensors are increasingly of interest and MIP-quartz crystal microbalance (QCM) have started to appear in the literature. In this study, we have combined quartz crystal microbalance with MIP to prepare a sensor using the ability of glucose to chelate of copper (II) ion of methacrylamidohistidine (MAH) monomer to create ligand exchange (LE) assembled monolayer which is suitable for glucose determination. The study includes the measurement of binding interaction of molecularly imprinted QCM sensor via ligand interaction, investigation of the pH effect on frequency shift and recognition selectivity studies of glucose-imprinted polymer with respect to methyl-alpha-d-glucopyranoside and sucrose. Bmax (number of binding sites) and K(D) (dissociation constant of the metal-chelate copolymer) were also calculated using Scathard plot and the detection limit was found as 0.07 mM. MIP showed higher glucose-binding affinity than a well-known glucose binding protein, conconavalin A. 相似文献
10.
Indest T Laine J Ribitsch V Johansson LS Stana-Kleinschek K Strnad S 《Biomacromolecules》2008,9(8):2207-2214
The adsorption behavior of chitosan on poly(ethylene terephthalate) (PET) model film surface was studied using the quartz crystal microbalance (QCM) technique. QCM with a dissipation unit (QCM-D) represents a very sensitive technique for adsorption studies at the solid/liquid interface in situ, with capability of detecting a submonolayer of adsorbate on the quartz crystal surface. Chitosan as well as PET were chosen for this study due to their promising biocompatible properties and numerous possibilities to be used in biomedical applications. As a first step, PET foils were activated by alkaline hydrolysis in order to increase their hydrophilicity. Model thin films were prepared from PET foils by the spin coating technique. The chemical composition of the obtained model PET films was analyzed using X-ray photoelectron spectroscopy (XPS) and their morphology was characterized by atomic force microscopy (AFM). Furthermore, the adsorption behavior of chitosan on these activated PET films and the influence of adsorption parameters (pH, ionic strength and chitosan solution concentration) were investigated in detail. Additionally, the surface chemistry and morphology of the PET films and the chitosan coated PET films were analyzed with XPS and AFM. 相似文献
11.
In 2010 there has again been an increase in the number of papers published involving piezoelectric acoustic sensors, or quartz crystal microbalances (QCM), when compared to the last period reviewed 2006‐2009. The average number of QCM publications per annum was 124 in the period 2001‐2005, 223 in the period 2006‐9, and 273 in 2010. There are trends towards increasing use of QCM in the study of protein adsorption to surfaces (93% increase), homeostasis (67% increase), protein‐protein interactions (40% increase), and carbohydrates (43% increase). New commercial systems have been released that are driving the uptake of the technology for characterisation of binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This article highlights theoretical and practical aspects of the principals that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells, and membrane interfaces. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
12.
Enzymatic degradation of the poly(L-lactide) (PLLA) amorphous film by proteinase K has been investigated by combination of the complementary techniques of quartz crystal microbalance and atomic force microscopy (AFM). The erosion rate increased with increasing enzyme concentrations and attained to be constant under the condition of [proteinase K] > 100 microg/mL. The amount of the enzyme molecules adsorbed to the film was quantitatively evaluated at various concentrations by AFM, and it revealed that the erosion rate is determined by the amount of adsorbed enzyme. Adsorption of proteinase K was irreversible despite lack of the binding domain, so that the enzyme molecules on the film surface could be observed directly by AFM. Transformation of the enzyme molecule caused by packing in high density on the surface was observed at higher enzyme concentrations. The "footprint" of the individual proteinase K molecule on the PLLA film after enzymatic degradation suggests that the enzyme moves on the surface to hydrolyze the film around it. 相似文献
13.
Specific and selective peptide-membrane interactions revealed using quartz crystal microbalance 下载免费PDF全文
Mechler A Praporski S Atmuri K Boland M Separovic F Martin LL 《Biophysical journal》2007,93(11):3907-3916
The skin secretions of Australian tree frogs are rich in peptides with potential antimicrobial activity. They interrupt bacterial cell membranes, although precisely how and whether all peptides have the same mechanism is not known. The interactions of three of these peptides—aurein 1.2, maculatin 1.1, and caerin 1.1 with supported phospholipid bilayers—are examined here using quartz crystal microbalance and atomic force microscopy. These approaches enabled us to reveal variations in material structure and density as a function of distance from the sensor surface when comparing mass sensorgrams over a range of harmonics of the natural resonance of the sensor crystal and hence obtain for the first time to our knowledge a mechanistic assessment of membrane disruption. We found that caerin inserted into the bilayer in a transmembrane manner, regardless of concentration and phospholipid composition consistent with a pore-forming mechanism. In contrast, maculatin and aurein interacted with membranes in a concentration-dependent manner. At low concentrations (<5 μM), maculatin exhibited transmembrane incorporation whereas aurein was limited to surface association. Upon reaching a threshold value of concentration, both peptides lysed the membrane. In the case of maculatin, the lysis progressed in a slow, concentration-dependent manner, forming mixed micelles, as shown by atomic force microscopy imaging. Aurein-induced lysis proceeded to a sudden disruption, which is consistent with the “carpet” mechanism. Both maculatin and aurein exhibit specificity toward phospholipids and thus have potential as candidates as antimicrobial drugs. 相似文献
14.
Prachayasittikul V Isarankura Na Ayudhya C Hilterhaus L Hinz A Tantimongcolwat T Galla HJ 《Biochemical and biophysical research communications》2005,327(1):174-182
Non-specific adsorption and specific interaction between a chimeric green fluorescent protein (GFP) carrying metal-binding region and the immobilized zinc ions on artificial solid-supported lipid membranes was investigated using the quartz crystal microbalance technique and the atomic force microscopy (AFM). Supported lipid bilayer, composed of octanethiol and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine/1,2-dioleoyl-sn-glycero-3-[N-(5-amino-1-carboxypentyl iminodiacetic acid)succinyl] (NTA-DOGS)-Zn2+, was formed on the gold electrode of quartz resonator (5 MHz). Binding of the chimeric GFP to zinc ions resulted in a rapid decrease of resonance frequency. Reversibility of the process was demonstrated via the removal of metal ions by EDTA. Nanoscale structural orientation of the chimeric GFP on the membrane was imaged by AFM. Association constant of the specific binding to metal ions was 2- to 3-fold higher than that of the non-specific adsorption, which was caused by the fluidization effect of the metal-chelating lipid molecules as well as the steric hindrance effect. This infers a possibility for a further development of biofunctionalized membrane. However, maximization is needed in order to attain closer advancement to a membrane-based sensor device. 相似文献
15.
Quartz crystal microbalance with dissipation monitoring (QCM-D) was used for continuous in-situ monitoring of cell attachment and growth of Streptococcus mutans as biofilms. Cell attachment and proliferation were monitored within an overnight period of 20 h. Biofilms generated using a 'continuous flow' method had a greater mass and were more dissipative (more viscoelastic) than those established using an 'attach and flow' strategy. Cell numbers (as colony forming units, c.f.u.) in biofilms formed inside the QCM-D device after a 2-h attachment phase and during a 20-h growth period could be related to frequency (f) changes. The percentage surface coverage on the QCM-D crystals by bacteria was estimated using the surface analysis features of the atomic force microscope and image analysis software. Both mean percentage coverage and c.f.u increased after growth of S. mutans. The energy losses displayed by the increases in the dissipative factor (D) indicated an increase in 'softness' of the attached cells. The ratio of D/f was used to provide information of the way in which viscoelasticity changed per unit mass. Flow conditions over the cells on the surface appeared to be important in creating biofilms of a greater complexity and stability and the QCM-D enabled properties of cells during attachment and binding, proliferation and removal to be monitored continuously. 相似文献
16.
The quartz crystal microbalance (QCM) has been widely accepted as a sensitive technique to follow adsorption processes in gas as well as in liquid environments. However, there are only a few reports about the use of this technique to monitor the attachment and spreading of mammalian cells onto a solid support in culture. Using a QCM-setup we investigated the time course of cell attachment and spreading as a function of seeding density for three widespread and frequently used cell lines (MDCK strains I and II and Swiss 3T3-fibroblasts). Results were found to be in good agreement with the geometrical properties of the individual cell types. The shifts of the resonance frequency associated with confluent cell layers on top of the quartz resonators were found to be dependent on the cell species [MDCK-I: (320±20) Hz; MDCK-II: (530±25) Hz; 3T3: (240±15) Hz] reflecting their individual influence on the shear oscillation of the resonator. These findings are discussed with respect to the basic models of materials in contact with an oscillating quartz resonator. We furthermore showed by inhibition-assays using soluble RGD-related peptides, that only specific, integrin mediated cell adhesion is detected using this QCM approach, whereas the sole presence of the cellular body in close vicinity to the resonator surface is barely detectable. 相似文献
17.
Model cellulose surfaces have attracted increasing attention for studying interactions with cell wall matrix polymers and as substrates for enzymatic degradation studies. Quartz crystal microbalance with dissipation monitoring (QCM-D) solvent exchange studies showed that the water content of regenerated cellulose (RC) films was proportional to the film thickness (d) and was consistent with about five water molecules per anhydroglucose unit. Sulfated nanocrystalline cellulose (SNC) and desulfated nanocrystalline cellulose (DNC) films had comparable water contents and contained about five times more water than RC films. A cellulase mixture served as a probe for studies of substrate accessibility and degradation. Cellulase adsorption onto RC films was independent of d, whereas degradation times increased with d. However, adsorption onto SNC and DNC films increased with d, whereas cellulase degradation times for DNC films were independent of studied d. Enhanced access to guest molecules for SNC and DNC films revealed they are more porous than RC films. 相似文献
18.
Effect of ultrasound on DNA polymerase reactions: monitoring on a 27-MHz quartz crystal microbalance
Effects of ultrasound irradiation on DNA polymerase (Klenow fragment, KF) reactions were studied on the template/primer DNA-immobilized quartz crystal microbalance (QCM). Under ultrasound irradiation, binding of KF to the DNA was suppressed due to the decrease of the binding rate constant (k(1)) and the increase of the dissociation rate constant (k(-)(1)). The catalytic elongation rate (k(cat)) was increased, but the stability of the KF/DNA/monomer ternary complex (K(m)) was decreased by the ultrasound irradiation. Ultrasound effects are discussed in correlation with the conformation changes of domain structures in KF. 相似文献
19.
Kurosawa S Park JW Aizawa H Wakida S Tao H Ishihara K 《Biosensors & bioelectronics》2006,22(4):473-481
This paper presents discussion of quartz crystal microbalance (QCM) immunosensors for environmental monitoring. Factors limiting the practical application of antibodies to analytical problems are also presented. Among several candidates for the QCM immunosensor device, selected QCM devices and oscillating circuits were tested thoroughly and developed to obtain highly stable and sensitive frequency signals. The biointerface of QCM immunosensor was designed and controlled to immobilize antibody on the QCM surface, to reduce non-specific binding and to suppress denaturation of immobilizing antibody by self-assembled monolayer technique and artificial phospholipid (2-methacryloyloxyethyl phosphorylcholine (MPC)) polymer. MPC polymer as a antibody-stabilizing reagent was added to reduce non-specific binding of the antigen solution and stabilize the immunologic activity of the antibody-immobilized QCM. In addition, it provides examples for detection and quantitation of environmental samples using QCM immunosensors. The analytical results for fly ash extracted samples of dioxins using the QCM immunosensor indicated a good relationship with GC/MS methods. The integrating protocols of the competitive immunoassay and signal-enhancing step are for detecting low molecular analytes with extremely low detection limits using an QCM immunosensor. Furthermore, its detect limitation was extended from 0.1 to 0.01 ng/ml by the signal-enhancing step when the anti-bisphenol-A antibody conjugated MPC polymeric nanoparticles was used. The QCM immunosensor method has demonstrated its effectiveness as an alternative screening method for environmental monitoring because these results were compared with results obtained through environmental monitoring methods such as ELISA and GC/MS. 相似文献
20.
This work was devoted to probe, at the entire population level, interactions between mucins and Lactococcus lactis, using QCM-D. Real-time monitoring of adsorption on polystyrene of PGM (Pig Gastric Mucin) and subsequent adhesion of L. lactis was performed for IBB477 and MG1820 strains. Measuring simultaneously shifts in resonance frequency and dissipation on the polystyrene-coated crystal demonstrated a two-phase process for PGM adsorption. XPS analysis confirmed the presence of adsorbed mucin. The Voigt-based model was used to describe the QCM-D outputs. The predicted thickness of the PGM layer was consistent with the AFM experimental value. Adhesion of L. lactis to bare or PGM-coated polystyrene was then monitored, in combination with DAPI cell counting. Positive frequency shifts were caused by adhering bacteria. The presence of adsorbed PGM strongly reduced bacterial adhesion. However, adhesion of IBB477 to the PGM coating was greatly increased in comparison with that of MG1820. Muco-adhesion may be a highly variable and valuable phenotypic trait among L. lactis strains. 相似文献