首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ye S  Li H  Cao W 《Biosensors & bioelectronics》2011,26(5):2215-2220
A novel electrogenerated chemiluminescence (ECL) biosensor based on the construction of triplex DNA for the detection of adenosine was designed. The ECL biosensor employs an aptamer as a molecular recognition element, and quenches ECL of tris(2,2'-bipyridine) ruthenium (Ru(bpy)(3)(2+)) by ferrocenemonocarboxylic acid (FcA). Through self-assembly technology, the ECL probe of thiolated hairpin adenosine aptamer tagged was self-assembled onto the surface of a gold electrode with an ECL signal producer Ru(bpy)(3)(2+) derivative (Ru-DNA-1). The adenosine aptamer, including a section of triplex characteristic chain, formatted triplex DNA with two other DNAs (DNA-2, Fc-DNA-3) in the presence of triplex DNA binder coralyne chloride (CORA). Fc-DNA-3 was tagged with an ECL quencher ferrocenemonocarboxylic acid (FcA), a quenching probe. In the presence of adenosine, the aptamer sequence (Ru-DNA-1) prefers to form the aptamer-adenosine complex with hairpin configuration and the switch of the DNA-1 occurs in conjunction with the generation of a strong ECL signal owing to the dissociation of a quenching probe. Meanwhile, a control experiment was performed; the ECL-duplex biosensor was designed to detect adenosine. The detection limits were 2.7×10(-10) mol L(-1) and 2.3×10(-9) mol L(-1) for the ECL-triplex DNA biosensor and ECL-duplex DNA biosensor, respectively, which demonstrated that the ECL-triplex DNA biosensor improved the sensitivity and specificity greatly.  相似文献   

2.
Recently, Breaker and coworkers engineered hammerhead ribozymes that rearrange from a catalytically inactive to an active conformation upon allosteric binding of a specific ligand. To monitor cleavage activity in real time, we have coupled a donor-acceptor fluorophore pair to the termini of the substrate RNA of such a hammerhead ribozyme, modified to cleave in trans in the presence of the bronchodilator theophylline. In the intact substrate, the fluorophores interact by fluorescence resonance energy transfer (FRET). The specific FRET signal breaks down as the effector ligand binds, the substrate is cleaved, and the products dissociate, with a rate constant dependent on the concentration of the ligand. Our biosensor cleaves substrate at 0.46 min(-1) in 1 mM theophylline and 0.04 min(-1) without effector, and discriminates against caffeine, a structural relative of theophylline. We have measured the theophylline-dependence profile of this biosensor, showing that concentrations as low as 1 microM can be distinguished from background. To probe the mechanism of allosteric regulation, a single nucleotide in the communication domain between the catalytic and ligand-binding domains was mutated to destabilize the inactive conformation of the ribozyme. As predicted, this mutant shows the same activity (0.3 min(-1)) in the presence and absence of theophylline. Additionally, time-resolved FRET measurements on the biosensor ribozyme in complex with a noncleavable substrate analog reveal no significant changes in fluorophore distance distribution upon binding of effector.  相似文献   

3.
Water safety is one of the most pervasive problems afflicting people throughout the world. Microcystin, a hepatotoxin produced by cyanobacteria, poses a growing and serious threat of water safety. According to World Health Organization (WHO), the limit of content of microcystin-LR (MC-LR) in drinking water is as low as 1μg/L; it is thus necessary to explore a sensitive method for the trace detection of microcystins (MCs). Based on the observation of gold nanoparticles (Au NPs) induced graphene oxide (GO) fluorescence quenching, a reliable biosensor was developed here for microcystins detection. MCs could be attached on Au NPs through the interaction with single strand-DNA (ss-DNA) modified on Au NPs, which formed Au-DNA-MCs complexes. These MCs in the complexes could be immunologically recognized by the antibodies adsorbed on GO sheets, as a result, Au NPs were close enough to quench the photoluminescence of GO by the fluorescence resonance energy transfer (FRET). The fluorescence intensity decreased with the increase of MCs as more Au NPs linked onto GO surface. The limit of detection was 0.5 and 0.3μg/L for microcystin-LR and microcystin-RR (MC-RR), respectively, which satisfies the strictest standard of WHO. Well defined results were also obtained in natural lake water and the specificity experiment. The antibody used here could recognize Adda group, the conservative part of MCs, which allowed the biosensor to detect both single toxin and the total content of MCs existing in the water sample.  相似文献   

4.
The aim of the present work is to develop an evanescence wave array biosensor exploiting the “kinetic” approach of enzymatic reaction and further detection of the reaction products via pH sensitive fluorophore reporter. To demonstrate the feasibility of this approach, we have developed a biosensor array with the potential for direct detection of organophosphates using as a biorecognition element, an enzyme organophosphorus hydrolase (OPH), conjugated with a pH-sensitive fluorophore, carboxynaphthofluorescein (CNF). The presence of reference spots allows the discrimination of the enzymatic and non-enzymatic based pH changes; bovine serum albumin (BSA) was used as a non-enzymatic scaffold protein for CNF attachment at the reference spots. An array biosensor unit developed at the Naval Research Laboratories (NRL) was adopted as the detection platform and appropriately modified for enzyme-based measurements. A planar multi-mode waveguide was covered with an optically transparent TiO2 layer to increase the surface area available for immobilization.

The biosensor enabled the detection of 2.5 μM paraoxon, and 10 μM DFP and parathion, respectively. Very short response time of 30 s can be achieved with a total analysis time of less than 2 min. When operated at room temperature and stored at 4 °C, the waveguide retained reasonable activity for greater than 45 days.  相似文献   


5.
Fluorescent lanthanide chelates with long decay times allow the suppression of the fast decaying autofluorescence in biological specimens. This property makes lanthanide chelates attractive as labels for fluorescence microscopy. As a consequence of the suppression of the background fluorescence the sensitivity can be increased. We modified a standard epifluorescence microscope for time-resolved fluorescence imaging by adding a pulsed light source and a chopper in the narrow aperture plane. A cooled CCD-camera was used for detection and the images were digitally processed. A fluorescent europium chelate was conjugated to antisera and to streptavidin. These conjugates were used for the localization of tumor associated antigen C242 in the malignant mucosa of human colon, for the localization of type II collagen mRNA in developing human cartilaginary growth plates, and for the detection of HPV type specific gene sequences in the squamous epithelium of human cervix. The specific slowly decaying fluorescence of the europium label could be effectively separated from the fast decaying background fluorescence. It was possible to use the europium label at the cell and tissue level and the autofluorescence was effectively suppressed in in situ hybridization and immunohistochemical reactions in both frozen and formaldehyde-fixed, wax-embedded specimens.  相似文献   

6.
Estrogenic compounds are an important class of hormonal substances that can be found as environmental contaminants, with sources including pharmaceuticals, human and animal waste, the chemical industry, and microbial metabolism. Here we report the creation of a biosensor useful for monitoring such compounds, based on complementation of fluorescent protein fragments. A series of sensors were made consisting of fragments of a split mVenus fluorescent protein fused at several different N-terminal and C-terminal positions flanking the ligand binding domain of the estrogen receptor alpha. When expressed in HeLa cells, sensor 6 (ERα 312-595) showed a nine-fold increase in fluorescence in the presence of estrogen receptor agonists or antagonists. Sensor 2 (ERα 281-549) discriminated between agonists and antagonists by showing a decrease in fluorescence in the presence of agonists while being induced by antagonists. The fluorescent signal of sensor 6 increased over a period of 24 h, with a two-fold induction visible at 4 h and four-fold at 8 h of ligand incubation. Ligand titration showed a good correlation with the known relative binding affinities of the compound. The sensor could detect a number of compounds of interest that can act as environmental endocrine disruptors. The lack of a substrate requirement, the speed of signal development, the potential for high throughput assays, and the ability to distinguish agonists from antagonists make this an attractive sensor for widespread use.  相似文献   

7.
The 9-hydroxy-1,3-diazaphenoxazine-2-one unit was conjugated with the Eu3+-cyclen complex through a linker. This diazaphenoxazine group was expected as an antenna unit for the excitation of europium ion, and a selective recognition site for 8-oxo-dGTP base. Among the synthesized three derivatives, the highest fluorescence emission was obtained by the complex constructed of an ethylene linker and the cyclen unit with three N,N-dimethylacetamide groups. The Eu3+-cyclen complex exhibited a selective response to the 8-oxo-dGTP in aqueous media by a time-resolved fluorescence assay.  相似文献   

8.
Adenosine deaminase, a purine salvage enzyme essential for immune competence, was studied by time-resolved fluorescence spectroscopy. The heterogeneous emission from this four-tryptophan protein was separated into three lifetime components: tau 1 = 1 ns and tau 2 = 2.2 ns an emission maximum at about 330 nm and tau 3 = 6.3 ns with emission maximum at about 340 nm. Solvent accessibility of the tryptophan emission was probed with polar and nonpolar fluorescence quenchers. Acrylamide, iodide, and trichloroethanol quenched emission from all three components. Acrylamide quenching caused a blue shift in the decay-associated spectrum of component 3. The ground-state analogue enzyme inhibitor purine riboside quenched emission associated with component 2 whereas the transition-state analogue inhibitor deoxycoformycin quenched emission from both components 2 and 3. The quenching due to inhibitor binding had no effect on the lifetimes or emission maxima of the decay-associated spectra. These observations can be explained by a simple model of four tryptophan environments. Quenching studies of the enzyme-inhibitor complexes indicate that adenosine deaminase undergoes different protein conformation changes upon binding of ground- and transition-state analogue inhibitors. The results are consistent with localized structural alterations in the enzyme.  相似文献   

9.
In this study, an acetylcholinesterase (AChE) biosensor with superior accuracy and sensitivity was successfully developed based on interdigitated array microelectrodes (IAMs). IAMs have a series of parallel microband electrodes with alternating microbands connected together. Chitosan was used as the enzyme immobilization material, and AChE was used as the model enzyme for carbaryl detection to fabricate AChE biosensor. Electrochemical impedance spectroscopy was used in conjunction with the fabricated biosensor to detect pesticide residues. Based on the inhibition of pesticides on the AChE activity, using carbaryl as model compounds, the biosensor exhibited a wide range, low detection limit, and high stability. Moreover, the biosensor can also be used as a new promising tool for pesticide residue analysis.  相似文献   

10.
This work presents the synthesis of bacteria-mediated bioimprinted films for selective bacterial detection. Marine pathogen sulfate-reducing bacteria (SRB) were chosen as the template bacteria. Chitosan (CS) doped with reduced graphene sheets (RGSs) was electrodeposited on an indium tin oxide electrode, and the resulting RGSs-CS hybrid film served as a platform for bacterial attachment. The electrodeposition conditions were optimized to obtain RGSs-CS hybrid films with excellent electrochemical performance. A layer of nonconductive CS film was deposited to embed the pathogen, and acetone was used to wash away the bacterial templates. Electrochemical impedance spectroscopy was performed to characterize the stepwise modification process and monitor the SRB population. Faradic impedance measurements revealed that the charge transfer resistance (R(ct)) increased with increased SRB concentration. A linear relationship between ΔR(ct) and the logarithm of SRB concentration was obtained within the concentration range of 1.0×10(4)cfumL(-1) to 1.0×10(8)cfumL(-1). The impedimetric sensor showed good selectivity towards SRB based on size and shape. Hence, selectivity for bacterial detection can be improved if the bioimprinting technique is combined with other bio-recognition elements.  相似文献   

11.
A monoclonal antibody (MAb)-gold biosensor chip with low-temperature laser-induced fluorescence detection for analysis of DNA-carcinogen adducts is described. Optimization of the detection limit, dynamic range, and biosensing applicability of the MAb-gold biosensor chip was achieved by: (1) using dithiobis(succinimidyl propionate (DSP)) as a protein linker and (2) employing recombinant protein A to provide oriented immobilization of the MAbs. The use of DSP, which has a short methylene chain length, led to faster protein binding kinetics and higher protein surface density than a longer dithiobis(succinimidyl undecanoate) (DSU) linker. The incorporation of recombinant protein A increased the distance between the oriented MAb-bound analytes and the gold surface. The increased distance minimized fluorescence quenching, resulting in about a 10-fold increase in the fluorescence signal in comparison with a chip without protein A. The improved chip architecture was used to demonstrate that biosensing of two structurally similar benzo[a]pyrene (BP)-derived DNA adducts, BP-6-N7Gua and BP-diolepoxide-10-N2dG, bound to two specific MAbs immobilized from a mixture at the same address on the chip, is feasible. These mutagenic adducts are formed by one-electron oxidation and monooxygenation pathways, and are depurinating and stable DNA adducts, respectively. It is shown that the DNA adducts can be easily identified at the same address using time-resolved, low-temperature laser-based fluorescence spectroscopy. The current limit of detection is in the low femtomole range. These results indicate that a single biosensor chip consisting of a Au/DSP/protein A/MAb nano-assembly, with analyte-specific MAbs and low-temperature fluorescence detection should be suitable for simultaneous detection and quantitation of the above adducts, as well as the luminescent antigens for which selective MAbs exist.  相似文献   

12.
Wu S  Zhang L  Qi L  Tao S  Lan X  Liu Z  Meng C 《Biosensors & bioelectronics》2011,26(6):2864-2869
A sensitive amperometric acetylcholinesterase (AChE) biosensor was fabricated based on mesocellular silica foam (MSF), which functioned as both an enzyme immobilization matrix and a solid phase extraction (SPE) material for the preconcentration of target molecules. The hydrophilic interface, the good mechanical/chemical stability, and the suitable pore dimension of MSF provided the entrapped AChE a good environment to well maintain its bioactivity at basic condition. The AChE immobilized in MSF showed improved catalytic ability for the hydrolysis of acetylthiocholine, as evidenced by the increasing of the oxidation current of thiocholine, the enzymatic catalytic hydrolysis production of acetylthiocholine. In addition, the MSF with large surface area showed a modest adsorption capacity for monocrotophos, a model organophosphate used in this study, via the hydrogen bond or physical adsorption interaction. The combination of the SPE and the good enzyme immobilization ability in MSF significantly promoted the sensitivity of the biosensor, and the limit of detection has lowered to 0.05 ng/mL. The biosensor exhibited accuracy, good reproducibility, and acceptable stability when used for garlic samples analysis. The strategy may provide a new method to fabricate highly sensitive biosensors for the detection of ultra-trace organophosphorous pesticide infield.  相似文献   

13.
An antibody-based electrochemical biosensing platform has been developed and used for the detection of protein. In the presence of the target, an antibody pair binds to the protein simultaneously, which causes two oligo-DNAs conjugated with the antibody pair to hybridize to each other and become a big “stem–loop” structure. Subsequently, the longer oligo-DNA of the stem, with a methylene blue (MB) label at the terminal, hybridizes stably with capture DNA owing to the enhancement of base stacking. The strong redox current signal of MB is used for protein quantification. Using α-fetoprotein (AFP) as a model, the proposed method could detect AFP at a concentration as low as 2 pg ml−1 with a dynamic range of 4 orders of magnitude, which approaches traditional assays such as enzyme-linked immunosorbent assay.  相似文献   

14.
We report a microfluidic sensing platform for the detection of thyroglobulin (Tg) using competitive protein adsorption. Serum Tg is a highly specific biomarker for residual thyroid tissue, recurrence and metastases after treatment for differentiated thyroid cancer (DTC). Conventional Tg detection techniques require complicated immobilization of antibodies and need to form a sandwich assay using additional secondary antibodies to enhance the sensitivity. We present a fundamentally different sensing technique without using antibody immobilization on a microfluidic platform. We engineer two surfaces covered by two known proteins, immunoglobulin G (IgG) and fibrinogen, with different affinities onto the surfaces. The microfluidic device offers a selective protein sensing by being displaced by a target protein, Tg, on only one of the surfaces. By utilizing the competitive protein adsorption, Tg displaces a weakly bound protein, IgG; however, a strongly bound protein, fibrinogen, is not displaced by Tg. The surface plasmon resonance (SPR) sensorgrams show that five human serum proteins, albumin, haptoglobin, IgG, fibrinogen and Tg, have different adsorption strengths to the surface and the competitive adsorption of individuals controls the exchange sequence. The adsorption and exchange are evaluated by fluorescent labeling of these proteins. Tg in a protein mixture of albumin, haptoglobin, and Tg is selectively detected based on the exchange reaction. By using the technique, we obviate the need to rely on antibodies as a capture probe and their attachment to transducers.  相似文献   

15.
In this study, we demonstrated that the fiber-optic biosensor based on localized surface plasmon coupled fluorescence (LSPCF) is capable of detecting alpha-fetoprotein (AFP) in human serum. The sensitivity of LSPCF fiber-optic biosensor is not only enhanced but also the specific selectivity is improved since the fluorophores are excited by the localized surface plasmon with high efficiency. Experimentally, this fiber-optic biosensor is able to detect AFP concentration in phosphate buffered saline (PBS) solution from 0.1ng/mL to 100ng/mL whereas the linear relationship between the AFP concentrations and the fluorescence signals is shown. Furthermore, a linear response between the fluorescence signals and the concentrations of AFP in human serum from 2.33ng/mL to 143.74ng/mL is also obtained. As a result, the detection limit of the LSPCF fiber-optic biosensor on AFP detection is comparable with the conventional enzyme-linked immunosorbent assay (ELISA). Additionally, the LSPCF fiber-optic biosensor benefits on inexpensive, disposable and simpler optical geometry that can become a high efficient immunoassay comparable with the conventional ELISA and radioimmunoassay (RIA) clinically.  相似文献   

16.
The hemin moiety of horseradish peroxidase (donor:hydrogen-peroxide oxidoreductase, EC 1.11.1.7) was removed and the apoprotein reconstituted with the fluorescent protoporphyrin IX. Steady-state and time-resolved fluorescence properties of the HRP(desFe) adduct were examined; the multifrequency phase and modulation method was utilized for lifetime and dynamic polarization studies. The emission spectrum of HRP(desFe) had maxima at 633 and 696 nm. The lifetime of this emission was characterized by a single exponential decay of 16.87 ns at 22 degrees C. Debye rotational relaxation times for HRP(desFe) were determined using both static (Perrin plot) and dynamic (differential phase and modulation fluorometry) methods; these two approaches gave values of 96 and 86 ns, respectively. A spherical protein of HRP's molecular weight and partial specific volume would be expected to have a Debye rotational relaxation time, at 22 degrees C, in the range of 50 to 60 ns, depending upon the extent of hydration. Hence our results indicate that HRP(desFe) is asymmetric; the global rotational relaxation times observed are consistent with those of a prolate ellipsoid with an axial ratio of 3:1.  相似文献   

17.
Conventional immunoassays are labor intensive, expensive and time consuming and require large pieces of equipment for detection. Therefore, we have developed and characterized a novel immunoassay methodology comprised of microbeads and microbiochips. In this method, microbeads are used to filter and immobilize antibodies and an immuno-gold silver staining (IGSS) method is then used to amplify electrical signals that correspond to the bound antibodies. The chip used for this system is composed of an inexpensive and biocompatible polydimethylsiloxane (PDMS) layer over a Pyrex glass substrate that contains a platinum (Pt) microelectrode, which is used to detect the electrical signal in this system, the microelectrode is fabricated on the substrate and a microchannel and pillar-type microfilter is formed in the PDMS layer. A sandwich immunoassay approach was applied to detect alpha-fetoprotein (AFP), a cancer biomarker, using this system. The results of this study showed that the time required for a complete assay was reduced by 1h and a detection limit as low as 1 ng/mL was attained when this system used, which indicates that similar bead-based electrical detection systems could be used for the diagnosis of many forms of cancer.  相似文献   

18.
Yessotoxin (YTX) is a generic name for a group of lipophilic compounds recently discovered and chemically characterized. Association measurements were done in a resonant mirror biosensor. The instrument detects changes in the refractive index and/or thickness occurring within a few hundred nanometers form the sensor surface where a molecule is attached. We used aminosilane surfaces where phosphodiesterase 3',5'-cyclic-nucleotide-specific from bovine brain (PDEs) was immobilized. Over this immobilized ligand different amounts of YTX were added and typical association curve profiles were observed. These association curves fit a pseudo-first-order kinetic equation where the apparent association rate constant (k(on)) can be calculated. The value of this constant increases with YTX concentration. From the representation of k(on) versus YTX concentration we obtained the association rate constant (k(ass)) 248+/-40 M(-1)s(-1) and the dissociation rate constant (k(diss)) 9.36 x 10(-4)+/-1.72 x 10(-4)s(-1). From these values the kinetic equilibrium dissociation constant (K(D)) for YTX-PDEs association can be calculated. The value of this last constant is 3.74 x 10(-6)+/-8.25 x 10(-8)M YTX. The PDE-YTX association was used as a method suitable for determination of the toxin concentration in a shellfish sample. The assay had sufficient sensitivity and can be used on simple shellfish extracts.  相似文献   

19.
We present the design, synthesis, and functional evaluation of peptide-based fluorescent constructs for wavelength-ratiometric biosensing of a protein analyte. The concept was shown using the high-affinity model interaction between the 18 amino acid peptide pTMVP and a recombinant antibody fragment, Fab57P. pTMVP was functionalized in two different positions with 6-bromomethyl-2-(2-furanyl)-3-hydroxychromone, an environmentally sensitive fluorophore with a two-band emission. The equilibrium dissociation constant of the interaction between pTMVP and Fab57P was largely preserved upon labeling. The biosensor ability of the labeled peptide constructs was evaluated in terms of the relative intensity change of the emission bands from the normal (N*) and tautomer (T*) excited-state species of the fluorophore ( I(N*)/I(T*)) upon binding of Fab57P. When the peptide was labeled in the C terminus, the I(N*)/I(T*) ratio changed by 40% upon analyte binding, while labeling close to the residues most important for binding resulted in a construct that completely lacked ratiometric biosensor ability. Integrated biosensor elements for reagentless detection, where peptides and ratiometric fluorophores are combined to ensure robustness in both recognition and signaling, are expected to become an important contribution to the design of future protein quantification assays in immobilized formats.  相似文献   

20.
A disposable immunosensor cartridge was developed that allows antibodies to be immobilized on the surface for the detection of myoglobin, a marker for the early assessment of acute myocardial infarction (AMI) using fluorescence techniques. The anti-myoglobin antibody was immobilized on a polystyrene substrate based on covalent bonding via silanization. The immunosensor chip layers were fabricated from sheets by CO(2)-laser ablation. The functionalized polystyrene surfaces were characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). After the antigen-antibody reaction as a sandwich enzyme-linked immunosorbent assay (ELISA) with a horseradish peroxidase-conjugated secondary antibody (HRP-anti-myoglobin), addition of fluorogenic substrate produced a fluorescent dye which was quantified on-chip using fluorescent technique. The immunosensor response was linear for myoglobin concentrations between 20 and 230 ng/ml (r=0.991, n=3). The detection limit was found to be 16 ng/ml, which is lower than the clinical cut-off value for myoglobin in healthy patients. This protocol could be extended to the detection of other important cardiac markers simultaneously in microchannels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号