首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Descemet’s Membrane Endothelial Keratoplasty (DMEK) is a form of corneal transplantation in which only a single cell layer, the corneal endothelium, along with its basement membrane (Descemet''s membrane) is introduced onto the recipient''s posterior stroma3. Unlike Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK), where additional donor stroma is introduced, no unnatural stroma-to-stroma interface is created. As a result, the natural anatomy of the cornea is preserved as much as possible allowing for improved recovery time and visual acuity4. Endothelial Keratoplasty (EK) is the procedure of choice for treatment of endothelial dysfunction. The advantages of EK include rapid recovery of vision, preservation of ocular integrity and minimal refractive change due to use of a small, peripheral incision1. DSAEK utilizes donor tissue prepared with partial thickness stroma and endothelium. The rapid success and utilization of this procedure can be attributed to availability of eye-bank prepared precut tissue. The benefits of eye-bank preparation of donor tissue include elimination of need for specialized equipment in the operating room and availability of back up donor tissue in case of tissue perforation during preparation. In addition, high volume preparation of donor tissue by eye-bank technicians may provide improved quality of donor tissue. DSAEK may have limited best corrected visual acuity due to creation of a stromal interface between the donor and recipient cornea. Elimination of this interface with transplantation of only donor Descemet''s membrane and endothelium in DMEK may improve visual outcomes and reduce complications after EK5. Similar to DSAEK, long term success and acceptance of DMEK is dependent on ease of availability of precut, eye-bank prepared donor tissue. Here we present a stepwise approach to donor tissue preparation which may reduce some barriers eye-banks face in providing DMEK grafts.  相似文献   

2.
Descemet Membrane Endothelial Keratoplasty (DMEK) selectively replaces the damaged posterior part of the cornea. However, the DMEK technique relies on a manually-performed dissection that is time-consuming, requires training and presents a potential risk of endothelial graft damages leading to surgery postponement when performed by surgeons in the operative room. To validate precut corneal tissue preparation for DMEK provided by a cornea bank in order to supply a quality and security precut endothelial tissue. The protocol was a technology transfer from the Netherlands Institute for Innovative Ocular Surgery (NIIOS) to Lyon Cornea Bank, after formation in NIIOS to the DMEK “no touch” dissection technique. The technique has been validated in selected conditions (materials, microscope) and after a learning curve, cornea bank technicians prepared endothelial tissue for DMEK. Endothelial cells densities (ECD) were evaluated before and after preparation, after storage and transport to the surgery room. Microbiological and histological controls have been done. Twenty corneas were manually dissected; 18 without tears. Nineteen endothelial grafts formed a double roll. The ECD loss after cutting was 3.3 % (n = 19). After transportation 7 days later, we found an ECD loss of 25 % (n = 12). Three days after cutting and transportation, we found 2.1 % of ECD loss (n = 7). Histology found an endothelial cells monolayer lying on Descemet membrane. The mean thickness was 12 ± 2.2 µm (n = 4). No microbial contamination was found (n = 19). Endothelial roll stability has been validated at 3 days in our cornea bank. Cornea bank technicians trained can deliver to surgeons an ECD controlled, safety and ready to use endothelial tissue, for DMEK by “no touch” technique, allowing time saving, quality and security for surgeons.  相似文献   

3.
This study was conducted to analyze the profile and thickness of endothelial keratoplasty lenticules prepared from fresh donated whole eyes with Visante optical coherence tomography (V-OCT) compared to measurements obtained from ultrasound pachymetry (USP) at the Central Eye Bank of Iran. Microkeratome-assisted precut corneas were prepared for Descemet stripping automated endothelial keratoplasty by using standard eye bank protocol. Central posterior lenticule thickness (CPLT) on fresh whole eye, before excising corneoscleral disc and transferring to Optisol-GS, was measured by USP. V-OCT was used to measure central, paracentral, and midperipheral thicknesses of lenticules after transferring the tissue to Optisol-GS. Chi Square and Bonferroni tests were respectively used to uncover the differences between the USP and V-OCT measurements and also the thickness profile of lenticules. Postoperative reports for the entire transplanted lenticules were recorded. Accordingly, on evaluation of 312 enrolled precut corneas, CPLT measurements by V-OCT versus USP were statistically different (mean: 136 µm vs 165 µm, respectively; P = 0.008). Thickness profile of the posterior lenticules revealed increased thickness from the central to the peripheral parts of the cornea (mean increase of 16 µm at the pericentral and 64.2 µm at the peripheral locations, respectively); however, the increase in the thickness was relatively symmetrical. Postoperative reports of transplanted lenticules were unremarkable, since there were no posterior flap detachments. In essence, V-OCT measurements of microkeratome-assisted precut lenticules prepared from fresh donated whole eyes averaged 29 μm thinner than USP measurements and revealed a significant but symmetric increase of thickness towards the peripheral parts of the corneas. However, the variation in the thickness profile did not affect the attachment or the clarity of transplanted precut lenticlues.  相似文献   

4.
To describe the technique and the results of the preparation of pre-cut corneas for Descemet’s stripping automated endothelial keratoplasty (DSAEK) during a 3-year period at the Central Eye Bank of Iran (CEBI). The method of preparation of pre-cut corneas from donated whole globes at the CEBI is described and the frequency and percentage of pre-cut corneas prepared for DSAEK, between April 2009 and March 2012, are specified. Moreover, post-operative reports are reviewed for any complaints about using pre-cut tissues for DSAEK. Out of the 1,518 donated whole globes appropriate for DSAEK, 1,478 (97.4 %) pre-cut corneas were successfully prepared. The method of preparation failed in 40 (2.6 %) cases. Based on the eye bank post-operative reports, thickness of pre-cut tissues for DSAEK was deemed unacceptable in only 6 (0.4 %) cases prior to surgery; five of these were too thick and one was too thin. Preparation of pre-cut corneas, for DSAEK from donated whole globes, in the CEBI is a safe and easy method, with very good preservation of endothelial cells after the preparation of the pre-cut corneas and reduced risks from corneal manipulation.  相似文献   

5.
Transplanting human tissue to the front of the eye has been practiced for over 100 years. Contiguous corneal layers may be transplanted separately (lamellar keratoplasty) or together (full thickness or penetrating keratoplasty). The former methods are gaining in popularity, replacing full thickness transplants. Reasons for transplantation and current practice and techniques are described with respect to their impact on vision, and associated adverse events.  相似文献   

6.
Clinical cryobiology of tissues: preservation of corneas   总被引:5,自引:0,他引:5  
M J Taylor 《Cryobiology》1986,23(4):323-353
It is well recognized that the clarity of the cornea is a function of its hydration, and that this hydration is controlled by a "pump-and-leak" mechanism operating across the posterior monolayer of cells called the endothelium. A breakdown of the endothelium through disease or injury causes a marked increase in corneal thickness as the stroma imbibes fluid from the aqueous humor in the anterior chamber of the eye. This thickened, edematous condition of the stroma results in a cloudy cornea with an associated marked decrease in visual acuity. Treatment for this condition is usually by full-thickness corneal transplantation (penetrating keratoplasty), the success of which is dependent upon the donor cornea having an intact and healthy endothelium. It is essential, therefore, that any method of corneal storage for penetrating keratoplasty should protect and preserve the endothelium in a viable state. Current clinical practice relies upon short-term methods of preservation by two principal methods. Moist Chamber Storage is the time-honored corneal preservation method; it consists of keeping enucleated eyes at 0-4 degrees C in a sealed jar containing a pad of cotton gauze soaked in saline to provide a humid environment. The time limit placed upon this method of storage is 24-48 hr after which the viability of the endothelium deteriorates rapidly. Storage in M-K (McCarey-Kaufman) Medium involves excision of the corneoscleral segment from the donor eye and immersing it, endothelial side uppermost, in a medium consisting of tissue culture medium, 5% Dextran 40, and antibiotics. Laboratory and clinical studies indicate that storage in M-K medium at 4 degrees C preserves human endothelial cells for up to 4 days when the eye has been removed from the cadaver in less than 10 hr postmortem. Long-term preservation of corneas by freezing has long been a major goal in eye banking because indefinite storage by cryopreservation offers significant advantages for the quality and the quantity of material for use in keratoplasty, as well as for its distribution. However, procedures that have been developed for the cryopreservation of corneas have not been widely used, and a number of studies have shown that these procedures are inadequate for maintaining the integrity of the corneal endothelium. Not surprisingly, clinicians are now reluctant to accept corneas that have been frozen by these methods, though the clinical need is now greater than ever.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

7.
Corneal grafts for Descemet’s Stripping Automated Endothelial Keratoplasty are commonly prepared using mechanical microkeratomes. However, the cuts produced in such way render corneal lenticules that are thinner centrally than peripherally, thus inducing a hyperopic shift. Here we describe a novel device for preparing donor corneal grafts, in which a single low-energy femtosecond laser system is used as both a light source for optical coherence tomography and for cutting the graft illuminating from the endothelial side. The same laser is first utilized to obtain three-dimensional optical coherence tomography images of the donor tissue for guiding the dissection and obtaining grafts of uniform thickness with no applanation or contact. This device allows an optimal procedure for preparing consistently thin posterior grafts for transplantation.  相似文献   

8.
To evaluate the efficacy and outcomes of tectonic epikeratoplasty with use of ethanol-preserved corneal grafts for the management of perforated corneal melts. The present retrospective case series includes 10 eyes which underwent tectonic epikeratoplasty for perforated corneal melts. The stromal remainders of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) graft preparation were stored in 95% ethanol and used as emergency tectonic grafts for restoring globe integrity after sterile and infectious perforated corneal melts. In 6 cases with subtotal corneal melt, DMEK remainders (endothelium-denuded corneoscleral buttons) were used for ‘limbus to limbus’ tectonic epikeratoplasty and in 4 cases DSAEK remainders (anterior stroma) were used to seal focal perforated melts. Graft storage time was 5.1?±?4.9 (ranging from 0.5 to 17) months. The surgeries were successful in all cases with restitution of the globe integrity. During the postoperative course 4 cases developed a graft melt (corneoscleral button for limbus to limbus tectonic epikeratoplasty, n?=?3; lamellar patch, n?=?1) within 2–6 months after the initial procedure. Three patients underwent successful repeat tectonic epikeratoplasty. In the fourth case of graft melt the globe was enucleated due to underlying expulsive haemorrhage and severe pain. The short-term results of the present case series suggest that the use of ethanol-stored stromal remainder of donor corneas after endothelial keratoplasty is an efficient temporary measure for tectonic restoration of perforated corneas.  相似文献   

9.
The presence of corneal antibodies in blood sera was investigated in 130 patients by immunoblotting analysis. Sera were obtained from patients before the first keratoplasty, repeated corneal transplantation or keratoplasty of the other eye. Baseline levels of antibodies in 15 healthy blood donors served to establish a positivity threshold. Patients were divided according to diagnosis and number of keratoplasties. Corneal antigens were prepared from donor corneas not suitable for surgery. Hyperimmune sera obtained by immunization of rabbits were used as positive controls. Significant increase in corneal antibodies specific to epithelial antigens was found in patients (62.5% positive) with keratitis of microbial origin. The presence of circulating antibodies to endothelial or stromal proteins was without significant changes. Depending on the number of keratoplasties no statistical difference in corneal antibodies production was observed. The group of patients with increased anti-corneal antibodies already before transplantation had to take immunosuppressive and anti-inflammatory therapy after keratoplasty.  相似文献   

10.
The short supply of donor corneas is exacerbated by the unsuitability of donors with insufficient endothelial cell density. Few studies have investigated promoting corneal endothelial cell proliferation to increase the endothelial cell density. We hypothesize that pre‐transplantation treatment of proliferative tissue‐cultivated corneas may increase corneal endothelial cell density. We observed that the airlift cultures were superior to immersion cultures with respect to both transparency and thickness. In this tissue culture system, we observed that lysophosphatidic acid increased the rabbit corneal endothelial cell density, number of BrdU‐positive cells and improve wound healing. We also observed an indirect effect of lysophosphatidic acid on corneal endothelial cell proliferation mediated by the stimulation of interleukin‐1β secretion from stromal cells. Human corneal tissues treated with lysophosphatidic acid or interleukin‐1β contained significantly more Ki‐67‐positive cells than untreated group. The lysophosphatidic acid‐ or interleukin‐1β‐treated cultured tissue remained hexagon‐shaped, with ZO‐1 expression and no evidence of the endothelial‐mesenchymal transition. Our novel protocol of tissue culture may be applicable for eye banks to optimize corneal grafting.  相似文献   

11.

Purpose

The aim of our investigation was to conduct a quantitative meta-analysis of the present world literature comparing the major surgical outcomes of penetrating keratoplasty (PKP) to lamellar procedures. Our goal is that clinicians, eye bank administrators, and health policy makers will be able to utilize this study in implementing decisions in regards to corneal transplantation.

Methods

Pooled measures of association were with odds ratios and because of study heterogeneity, the pooled effects were assumed to follow a random effects model (DerSimonian-Laird). The comparisons were between 1) PKP’s and all lamellar procedures (anterior AND posterior) and then 2) between PKP’s and all anterior lamellar procedures and 3) PKP and all posterior lamellar procedures.

Results

For PKP vs anterior lamellar procedures, the pooled odds ratio for rejection of PKP over lamellar keratoplasty (LK) was 3.56 (95% CI: 1.76-7.20) and for outright failure, the pooled odds ratio of PKP failure vs LK was 2.85 (95% CI: 0.84-9.66). For posterior lamellar procedures, the pooled odds ratio for rejection of PKP over LK was 1.52 (95% CI: 1.00-2.32). The pooled odds ratio for outright failure of PKP over posterior lamellar procedures was 2.09 (95% CI: 0.57-7.59). The follow up time was significantly longer for full transplants than for lamellar procedures.

Conclusions

For both anterior and posterior lamellar procedures, the odds ratios comparing rejection of full transplants to lamellar procedures (both anterior and posterior individually) were significantly higher in the PKP group. For outright failure, the PKP group also had a higher risk of failure than the lamellar groups but this was not statistically significant in either instance (anterior or posterior). Some of the clinical differences benefitting lamellar procedures may at least be partly explained by follow up time differences between groups and this needs to be accounted for more rigorously in future studies.  相似文献   

12.

Purpose

To assess the relationship of intraocular forward scattering and corneal higher-order aberrations (HOAs) with best spectacle corrected visual acuity (BSCVA) after Descemet’s stripping automated endothelial keratoplasty (DSAEK), and to compare these parameters between DSAEK and non-Descemet’s stripping automated endothelial keratoplasty (n-DSAEK) groups.

Methods

This retrospective study enrolled thirty eyes of 30 consecutive patients who underwent standard DSAEK, and who underwent successful phacoemulsification with intraocular lens implantation before DSAEK. The mean age at the time of surgery was 71.7 ± 10.4 years. We quantitatively evaluated the objective scattering index (OSI) using the double-pass instrument (OQAS II, Visiometrics) and corneal HOAs using Hartmann-Shack aberrometry (KR-9000PW, Topcon) 3 months postoperatively.

Results

The mean OSI, corneal HOAs, and logMAR BSCVA 3 months after DSAEK were 7.91 ± 3.58, 0.43 ± 0.27 μm, and 0.32 ± 0.25, respectively. We found a significant correlation between the OSI and logMAR BSCVA (Spearman correlation coefficient r=0.714, p<0.001), but no significant association between corneal HOAs and logMAR BSCVA 3 months postoperatively (r=0.209, p=0.267). We found no significant differences in any postoperative parameters between the DSAEK and n-DSAEK groups (p>0.05).

Conclusions

Our pilot study demonstrated that the postoperative corrected visual acuity was significantly correlated with intraocular forward scattering, but not with corneal HOAs in post-DSAEK eyes, suggesting that intraocular forward scattering plays a more essential role in postoperative visual performance than corneal aberrations after DSAEK. The detailed visual performance, such as HOAs and intraocular scattering, after n-DSAEK appears to be essentially equivalent to that after DSAEK.  相似文献   

13.

Purpose

To investigate the outcomes and complications of suture pull-through insertion techniques for Descemet stripping automated endothelial keratoplasty (DSAEK) in Chinese phakic eyes.

Patients and Methods

Retrospective case series. Included in the study were all Chinese patients with phakic eyes who underwent DSAEK at Peking University Third Hospital from August 2008 to August 2011. All ocular diseases of the patients were recorded. Distance visual acuity (DVA), near visual acuity (NVA), intraocular pressure (IOP), anterior chamber depth (ACD), central corneal thickness (CCT), and corneal endothelial cell density (ECD) were compared prior to and 12 months after DSAEK. The DSAEK success rate, endothelial cell loss (ECL), complications, and prognosis were analyzed. All patients had at least 12 months of follow up.

Results

Twenty-one eyes of 16 patients were included (11 males and 5 females). Ages ranged from 2 to 47 years with an average age of 29.8 years. The average follow up was 15.4 months (ranging from 12 to 36 months). Diagnoses included 7 eyes (4 patients) with corneal endothelial dystrophy and 14 eyes (12 patients) with bullous keratopathy. Presurgical DVA and NVA (LogMAR) were 1.7±0.7 and 1.2±0.4; postsurgical DVA and NVA were 0.8±0.6 and 0.7±0.5; Z = −3.517, −2.764; P<0.001 and P = 0.006 respectively. Presurgical IOP was 15.8±3.7 mm Hg; postsurgical IOP was 15.2±2.6 mm Hg; Z = −0.505, P = 0.614. Presurgical ACD was 3.00±0.74 mm; postsurgical ACD was 2.72±0.59 mm; Z = −0.524, P = 0.600. Donor ECD was 2992±163 cells/mm2, ECD was 1836±412 cells/mm2 with a 12-month postsurgical ECL of 39%. Success rate was 86%. Surgery complications included pupillary block-induced hypertension in 5 eyes (24%), graft detachment in 3 eyes (14%), and graft dislocation in 1 eye (5%).

Conclusions

DSAEK on Chinese phakic eyes can significantly improve DVA and NVA by preserving the patient’s own crystalline lens. DSAEK is an optional surgery for patients who need to preserve accommodative function. More attention should be given to postsurgical pupillary block-induced hypertension.  相似文献   

14.
To compare precut and surgeon-cut organ cultured donor corneas for DSAEK. A total of 119 consecutive eyes treated with DSAEK were retrospectically identified. 65 grafts were cut by the surgeon (Moria, ALTK System) prior to DSAEK and 54 grafts were precut by laboratory technicians from the Danish Eye Bank (Horizon single-use system). 1 year after surgery, tomographic images were obtained with the Pentacam HR. Endothelial cell density (ECD) and best-corrected visual acuity (BCVA) was determined. Graft thickness and graft asymmetry was evaluated in the centre and 1 mm from the edge of the graft in 6 semi-meridians. 1 year after surgery, the ECD loss was similar in the two groups, averaging 25.9 ± 14 % in surgeon-cut, and 22.9 ± 17 % in precut group (p = 0.33). Mean central graft thickness was 172 ± 6 μm in surgeon-cut grafts and 182 ± 6 μm in precut grafts (p = 0.30). BCVA was similar in surgeon-cut and precut corneas; being 0.25 ± 0.02 logMAR and 0.24 ± 0.02 logMAR, respectively (p = 0.59). The graft asymmetry index was 1.48 ± 0.02 for surgeon-cut and 1.44 ± 0.02 for precut grafts. There were no significant differences in complications rate in both groups. No correlations between BCVA and central graft thickness or graft asymmetry index in both groups were observed. Organ cultured precut donor corneas are comparable with surgeon-cut grafts with respect to ECD, graft thickness and asymmetry, and postoperative complication rate.  相似文献   

15.
Considerable interest has been generated for the development of suitable corneal endothelial graft alternatives through cell-tissue engineering, which can potentially alleviate the shortage of corneal transplant material. The advent of less invasive suture-less key-hole surgery options such as Descemet’s Stripping Endothelial Keratoplasty (DSEK) and Descemet’s Membrane Endothelial Keratoplasty (DMEK), which involve transplantation of solely the endothelial layer instead of full thickness cornea, provide further impetus for the development of alternative endothelial grafts for clinical applications. A major challenge for this endeavor is the lack of specific markers for this cell type. To identify genes that reliably mark corneal endothelial cells (CECs) in vivo and in vitro, we performed RNA-sequencing on freshly isolated human CECs (from both young and old donors), CEC cultures, and corneal stroma. Gene expression of these corneal cell types was also compared to that of other human tissue types. Based on high throughput comparative gene expression analysis, we identified a panel of markers that are: i) highly expressed in CECs from both young donors and old donors; ii) expressed in CECs in vivo and in vitro; and iii) not expressed in corneal stroma keratocytes and the activated corneal stroma fibroblasts. These were SLC4A11, COL8A2 and CYYR1. The use of this panel of genes in combination reliably ascertains the identity of the CEC cell type.  相似文献   

16.
Hyaluronic acid (HA) is a linear polysaccharide naturally found in the eye and therefore is one of the most promising biomaterials for corneal endothelial regenerative medicine. This study reports, for the first time, the development of overrun-processed porous HA hydrogels for corneal endothelial cell (CEC) sheet transplantation and tissue engineering applications. The hydrogel carriers were characterized to examine their structures and functions. Evaluations of carbodiimide cross-linked air-dried and freeze-dried HA samples were conducted simultaneously for comparison. The results indicated that during the fabrication of freeze-dried HA discs, a technique of introducing gas bubbles in the aqueous biopolymer solutions can be used to enlarge pore structure and prevent dense surface skin formation. Among all the groups studied, the overrun-processed porous HA carriers show the greatest biological stability, the highest freezable water content and glucose permeability, and the minimized adverse effects on ionic pump function of rabbit CECs. After transfer and attachment of bioengineered CEC sheets to the overrun-processed HA hydrogel carriers, the therapeutic efficacy of cell/biopolymer constructs was tested using a rabbit model with corneal endothelial dysfunction. Clinical observations including slit-lamp biomicroscopy, specular microscopy, and corneal thickness measurements showed that the construct implants can regenerate corneal endothelium and restore corneal transparency at 4 weeks postoperatively. Our findings suggest that cell sheet transplantation using overrun-processed porous HA hydrogels offers a new way to reconstruct the posterior corneal surface and improve endothelial tissue function.  相似文献   

17.
This study was conducted to analyze the preoperative thickness profile and endothelial rating of ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) tissues prepared with a single versus double microkeratome pass from donated whole eyes and corresponding eye bank postoperative results. Microkeratome-assisted UT-DSAEK tissues were prepared from freshly donated whole eyes with single-pass (SP) and double-pass (DP) technique in the Central Eye Bank of Iran. Preoperative thickness profiles and endothelial cell densities of UT-DSAEK tissues were obtained from optical coherence tomography and specular microscopy, respectively, and compared between groups. Corneal perforation rates during the eye bank preparation and postoperative reports of transplanted UT-DSAEK tissues were also compared. Over a 15-month period, 342 UT-DSAEK tissues were prepared: 248 via SP and 94 with DP technique. Mean donor corneal central thickness was 610?±?58 µm with SP and 790?±?100 µm with DP technique. Mean central thickness of UT-DSAEK tissues was not statistically different between the groups (84.8?±?11.0 µm with SP and 85.1?±?10.5 µm with DP technique, P?=?0.857). Mean increase of UT-DSAEK thickness from central to pericentral and peripheral cornea was not significantly different with both techniques. Mean differences between thicknesses of 2 pericentral locations and between those of 2 peripheral locations were not statistically different in the study groups. Corneal perforation of 1.6 and 1.1% occurred in SP and DP groups, respectively. Failed graft was reported 6 months postoperatively in 4 (1.6%) cases with SP and in 1 (1.1%) case with DP technique. Preoperative thickness profiles of UT-DSAEK tissues prepared from donated whole eyes via SP technique were not significantly different from those prepared with DP, showing a symmetric increase of thickness towards peripheral locations.  相似文献   

18.
To analyze the data of the adverse events collected in a single major eye bank (EFS Bourgogne Franche Comté, Besançon, France) for the year 2013 and to report the French data of biovigilance provided by the French National Agency for Medicines and Health Products Safety (ANSM) between 2010 and 2013. we have set up a study of adverse events in 2013, in collaboration with a single eye bank (EFS Bourgogne Franche Comté, Besançon, France). A survey was sent to the surgeon for each delivered corneal button by the eye bank in 2013. They were asked for each grafted patient performed in their center, the type of graft (penetrating keratoplasty, anterior keratoplasty or endothelial keratoplasty), the occurrence of adverse events (primary failure, infectious keratis, endophthalmitis, immune rejection, and other events) and the time interval between surgery and events (Less than 1 postoperative month, between 1 month and 1 year postoperatively, >1 year postoperatively). In 2013, 407 corneal buttons were delivered by the eye bank of Besançon in 21 medical centers which performed corneal grafts and we sent 407 surveys. We received 243 completed questionnaires (59.75%) from 11 centers (52.38%). The global reported rate of adverse events was 27.54% of the graft (n = 65/236 corneal grafts performed in 11 centers in 2013; 20% of Primary graft failure, 11% of infectious keratitis, 1% of endophthalmitis, 34% of rejection, 34% of other incidents). 30.16% of complications were noticed before the first month after surgery versus 52.38% of complications noticed between the first month and the first year after surgery and 17.46% of complications noticed after the post-operative first year The most common causes of adverse events after PK were Immune rejection (13.17%), surgical causes (5.98%) and infection (4.79%) and after EK were Primary graft failure (8.2%) and surgical causes (19.67%). In 2013, in France 0.83% of adverse events were notified in ANSM. For the 236 performed graft issued from a major eye bank (EFS Besançon) in 2013 the global reported rate of post-graft adverse events was 27.54% of the grafts (20% of Primary graft failure, 11% of infectious keratitis, 1% of endophthalmitis, 34% of rejection and 34% of other incidents). Compared to the ANSM data (0.83% of adverse events reported in 2013) this rate is high. This difference can be explained by the low rate of annual notification to the ANSM and shows that biovigilance in France must be more developed. Since biovigilance needs constant improvement for the safety of the graft system, training, information for practitioners, simplifications of procedures and international standardization of the definition are the main points that could be improved.  相似文献   

19.
The mechanical properties of the rabbit and human cornea   总被引:5,自引:0,他引:5  
The extensibility of rabbit and human corneas was measured by raising the pressure within the intact globe of the eye and measuring the displacements of two very small mercury drops on the corneal surface. The human cornea showed a negligible extensibility under low stresses. The rabbit tissue, however, underwent a 9% strain under low pressures with a curvilinear relationship between stress and strain. At higher pressures the relationship was linear, and the tissue showed some creep. The low pressure stress-strain relationship of the rabbit could not be explained on the basis that the collagen fibrils were being straightened out from an initial set in a sinusoidal wave. When the stroma was isolated from Descemet's membrane, it showed a negligible low pressure extensibility in rabbit and man. On the other hand, isolated Descemet's membrane was very extensible in both species. The difference between them in the behavior of the intact cornea seems to lie in the relative initial strain in the stroma and Descemet's membrane.  相似文献   

20.
The purpose of this study was to image and quantify the structural changes of corneal edema by second harmonic generation (SHG) microscopy. Bovine cornea was used as an experimental model to characterize structural alterations in edematous corneas. Forward SHG and backward SHG signals were simultaneously collected from normal and edematous bovine corneas to reveal the morphological differences between them. In edematous cornea, both an uneven expansion in the lamellar interspacing and an increased lamellar thickness in the posterior stroma (depth > 200 μm) were identified, whereas the anterior stroma, composed of interwoven collagen architecture, remained unaffected. Our findings of heterogeneous structural alteration at the microscopic scale in edematous corneas suggest that the strength of collagen cross-linking is heterogeneous in the corneal stroma. In addition, we found that qualitative backward SHG collagen fiber imaging and depth-dependent signal decay can be used to detect and diagnose corneal edema. Our work demonstrates that SHG imaging can provide morphological information for the investigation of corneal edema biophysics, and may be applied in the evaluation of advancing corneal edema in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号