首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The use of nucleic acid probes directly labeled with horseradish peroxidase for detection of single copy sequences on Southern blots of human genomic DNA by enhanced chemiluminescence is described. Of the target sequences, 6 x 10(5) molecules (1 amol) have been detected on blue sensitive film using exposures of up to 60 min and probes of 0.3-5.1 kb. The chemiluminescent signal quantified using a cooled charge coupled device (CCD) camera is proportional to probe length for DNA probes in the range 50-3571 bases. The enzyme has no significant effect on the stability of a DNA/DNA hybrid formed with a 3571-base probe and target as determined by increasing the stringency of posthybridization washes by decreasing the concentration of a monovalent cation (NaCl) and by a Tm analysis. The kinetics of DNA hybridization have been analyzed by a cooled CCD camera to provide quantitative data. Ten nanograms per milliliter of probe may be used for an overnight hybridization. Southern blots can be reprobed using a DNA probe for the same or a different sequence without the necessity of stripping off the previously bound probe.  相似文献   

2.
CCD cameras have numerous advantages over photographic film for detecting electrons; however the point spread function of these cameras has not been sufficient for single particle data collection to subnanometer resolution with 300kV microscopes. We have adopted spectral signal to noise ratio (SNR) as a parameter for assessing detector quality for single particle imaging. The robustness of this parameter is confirmed under a variety of experimental conditions. Using this parameter, we demonstrate that the SNR of images of either amorphous carbon film or ice embedded virus particles collected on a new commercially available 4kx4k CCD camera are slightly better than photographic film at low spatial frequency (<1/5 Nyquist frequency), and as good as photographic film out to half of the Nyquist frequency. In addition it is slightly easier to visualize ice embedded particles on this CCD camera than on photographic film. Based on this analysis it is realistic to collect images containing subnanometer resolution data (6-9A) using this CCD camera at an effective magnification of approximately 112000x on a 300kV electron microscope.  相似文献   

3.
A rapid chemiluminescent method for quantitation of human DNA.   总被引:15,自引:0,他引:15       下载免费PDF全文
A sensitive and simple method for the quantitation of human DNA is described. This method is based on probe hybridization to a human alpha satellite locus, D17Z1. The biotinylated probe is hybridized to sample DNA immobilized on nylon membrane. The subsequent binding of streptavidin-horseradish peroxidase to the bound probe allows for chemiluminescent detection using a luminol-based reagent and X-ray film. Less than 150 pg of human DNA can easily be detected with a 15 minute exposure. The entire procedure can be performed in 1.5 hours. Microgram quantities of nonhuman DNA have been tested and the results indicate very high specificity for human DNA. The data on film can be scanned into a computer and a commercially available program can be used to create a standard curve where DNA quantity is plotted against the mean density of each slot blot signal. The methods described can also be applied to the very sensitive determination of quantity and quality (size) of DNA on Southern blots. The high sensitivity of this quantitation method requires the consumption of only a fraction of sample for analysis. Determination of DNA quantity is necessary for RFLP and many PCR-based tests where optimal results are obtained only with a relatively narrow range of DNA quantities. The specificity of this quantitation method for human DNA will be useful for the analysis of samples that may also contain bacterial or other non-human DNA, for example forensic evidence samples, ancient DNA samples, or clinical samples.  相似文献   

4.
Digital chemiluminescence imaging with a cryogenically cooled charge-coupled device (CCD) camera is used to visualize DNA sequencing fragments covalently bound to a blotting membrane. The detection is based on DNA hybridization with an alkaline phosphatase(AP) labeled oligodeoxyribonucleotide probe and AP triggered chemiluminescence of the substrate 3-(2'-spiro-adamantane)-4-methoxy-4-(3"-phosphoryloxy)phenyl- 1,2-dioxetane (AMPPD). The detection using a direct AP-oligonucleotide conjugate is compared to the secondary detection of biotinylated oligonucleotides with respect to their sensitivity and nonspecific binding to the nylon membrane by quantitative imaging. Using the direct oligonucleotide-AP conjugate as a hybridization probe, sub-attomol (0.5 pg of 2.7 kb pUC plasmid DNA) quantities of membrane bound DNA are detectable with 30 min CCD exposures. Detection using the biotinylated probe in combination with streptavidin-AP was found to be background limited by nonspecific binding of streptavidin-AP and the oligo(biotin-11-dUTP) label in equal proportions. In contrast, the nonspecific background of AP-labeled oligonucleotide is indistinguishable from that seen with 5'-32P-label, in that respect making AP an ideal enzymatic label. The effect of hybridization time, probe concentration, and presence of luminescence enhancers on the detection of plasmid DNA were investigated.  相似文献   

5.
Electron cryo-microscopy (cryo-EM) images are commonly collected using either charge-coupled devices (CCD) or photographic film. Both film and the current generation of 16 megapixel (4k × 4k) CCD cameras have yielded high-resolution structures. Yet, despite the many advantages of CCD cameras, more than two times as many structures of biological macromolecules have been published in recent years using photographic film. The continued preference to film, especially for subnanometer-resolution structures, may be partially influenced by the finer sampling and larger effective specimen imaging area offered by film. Large format digital cameras may finally allow them to overtake film as the preferred detector for cryo-EM. We have evaluated a 111-megapixel (10k × 10k) CCD camera with a 9 μm pixel size. The spectral signal-to-noise ratios of low dose images of carbon film indicate that this detector is capable of providing signal up to at least 2/5 Nyquist frequency potentially retrievable for 3D reconstructions of biological specimens, resulting in more than double the effective specimen imaging area of existing 4k × 4k CCD cameras. We verified our estimates using frozen-hydrated ε15 bacteriophage as a biological test specimen with previously determined structure, yielding a ~7 ? resolution single particle reconstruction from only 80 CCD frames. Finally, we explored the limits of current CCD technology by comparing the performance of this detector to various CCD cameras used for recording data yielding subnanometer resolution cryo-EM structures submitted to the electron microscopy data bank (http://www.emdatabank.org/).  相似文献   

6.
This work describes a novel charge-coupled device (CCD)-based imaging system (MB Biochip Reader?) for real-time detection of DNA hybridization to DNA microarrays. The MB Biochip Reader? consisted of a laser light source (532 nm), a microlens array for generation of a multi-beam laser, and a CCD for 2-D signal imaging. The MB Biochip Reader? with a rotated microlens array, allowed large-field imaging (6.2 mm × 7.6 mm with 6.45 μm resolution) with fast time-resolution at 0.2 s without speckle noise. Furthermore, real-time detection of DNA hybridization, which is sufficient to obtain accurate data from tens of thousands of array element per field, was successfully performed without the need for laser scanning. The performance of the MB Biochip Reader? for DNA microarray imaging was similar to the commercially available photomultiplier tube (PMT)-based microarray scanner, ScanArray Lite. The system potentially could be applied toward real-time analysis in many other fluorescent techniques in addition to real-time DNA microarray analysis.  相似文献   

7.
Complex probes used in fluorescence in situ hybridization (FISH) usually contain repetitive DNA sequences. For chromosome painting, in situ suppression of these repetitive DNA sequences has been well established. Standard painting protocols require large amounts of an unlabeled 'blocking agent', for instance Cot-1 DNA. Recently, it has become possible to remove repetitive DNA sequences from library probes by means of magnetic purification and affinity PCR. Such a 'repeat depleted library probe' was hybridized to the q-arm of chromosome 15 of human metaphase spreads and interphase cell nuclei without any preannealing by Cot-1 DNA. Apart from this, 'standard' FISH conditions were used. After in situ hybridization, microscope images were obtained comparable to those achieved with the #15q library probe prior to depletion. The images were recorded by a true color CCD camera. By digital image analysis using 'line scan' and 'area scan' procedures, the painting efficiency expressed in terms of relative fluorescence signal intensity was quantitatively evaluated. The painting efficiency using the repeat depleted probe of chromosome 15q was compared to the painting efficiency after standard FISH. The results indicate that both types of probes are compatible to a high FISH efficiency. Using equivalent probe concentrations, no significant differences were found for FISH with standard painting probes and repeat depleted painting probes.  相似文献   

8.
For three-dimensional (3D) structure determination of large macromolecular complexes, single-particle electron cryomicroscopy is considered the method of choice. Within this field, structure determination de novo, as opposed to refinement of known structures, still presents a major challenge, especially for macromolecules without point-group symmetry. This is primarily because of technical issues: one of these is poor image contrast, and another is the often low particle concentration and sample heterogeneity imposed by the practical limits of biochemical purification. In this work, we tested a state-of-the art 4 k x 4 k charge-coupled device (CCD) detector (TVIPS TemCam-F415) to see whether or not it can contribute to improving the image features that are especially important for structure determination de novo. The present study is therefore focused on a comparison of film and CCD detector in the acquisition of images in the low-to-medium ( approximately 10-25 A) resolution range using a 200 kV electron microscope equipped with field emission gun. For comparison, biological specimens and radiation-insensitive carbon layers were imaged under various conditions to test the image phase transmission, spatial signal-to-noise ratio, visual image quality and power-spectral signal decay for the complete image-processing chain. At all settings of the camera, the phase transmission and spectral signal-to-noise ratio were significantly better on CCD than on film in the low-to-medium resolution range. Thus, the number of particle images needed for initial structure determination is reduced and the overall quality of the initial computed 3D models is improved. However, at high resolution, film is still significantly better than the CCD camera: without binning of the CCD camera and at a magnification of 70 kx, film is better beyond 21 A resolution. With 4-fold binning of the CCD camera and at very high magnification (> 300 kx) film is still superior beyond 7 A resolution.  相似文献   

9.
Time stretch imaging offers real-time image acquisition at millions of frames per second and subnanosecond shutter speed, and has enabled detection of rare cancer cells in blood with record throughput and specificity. An unintended consequence of high throughput image acquisition is the massive amount of digital data generated by the instrument. Here we report the first experimental demonstration of real-time optical image compression applied to time stretch imaging. By exploiting the sparsity of the image, we reduce the number of samples and the amount of data generated by the time stretch camera in our proof-of-concept experiments by about three times. Optical data compression addresses the big data predicament in such systems.  相似文献   

10.
文章讨论了DNA芯片的制作原理和杂交信号的检测方法。依其结构,DNA芯片可分为两种形式,DNA阵列和寡核苷酸微芯片。DNA芯片的制作方法主要有光导原位合成法和自动化点样法。DNA芯片与标记的探针或DNA样品杂交,并通过探测杂交信号谱型来实现DNA序列或基因表达的分析。适应于DNA芯片的发展,同时出现了许多新型的杂交信号检测方法。主要有激光荧光扫描显微镜、激光扫描共焦显微镜、结合使用CCD相机的荧光显微镜、光纤生物传感器、化学发生法、光激发磷光物质存储屏法、光散射法等。  相似文献   

11.
Hyperspectral imaging: a novel approach for microscopic analysis   总被引:3,自引:0,他引:3  
BACKGROUND: The usefulness of the light microscope has been dramatically enhanced by recent developments in hardware and software. However, current technologies lack the ability to capture and analyze a high-resolution image representing a broad diversity of spectral signatures in a single-pass view. We show that hyperspectral imaging offers such a technology. METHODS AND RESULTS We developed a prototype hyperspectral imaging microscope capable of collecting the complete emission spectrum from a microscope slide. A standard epifluorescence microscope was optically coupled to an imaging spectrograph, with output recorded by a CCD camera. Software was developed for image acquisition and computer display of resultant X--Y images with spectral information. Individual images were captured representing Y-wavelength planes, with the stage successively moved in the X direction, allowing an image cube to be constructed from the compilation of generated scan files. This prototype instrument was tested with samples relevant to cytogenetic, histologic, cell fusion, microarray scanning, and materials science applications. CONCLUSIONS: Hyperspectral imaging microscopy permits the capture and identification of different spectral signatures present in an optical field during a single-pass evaluation, including molecules with overlapping but distinct emission spectra. This instrument can reduce dependence on custom optical filters and, in future imaging applications, should facilitate the use of new fluorophores or the simultaneous use of similar fluorophores.  相似文献   

12.
A method is described for the detection of DNA hybrids formed on a solid support, based upon the pairing of oligonucleotide chemistry and the technologies of electronic microdevice design. Surface matrices have been created in which oligonucleotide probes are covalently linked to a thin SiO2 film. 32P labeled target nucleic acid is then hybridized to this probe matrix under conditions of high stringency. The salient feature of the method is that to achieve the highest possible collection efficiency, the hybridization matrix is placed directly on the surface of a charge coupled device (CCD), which is used to detect 32P decay from hybridized target molecules (1, Eggers, M.D., Hogan, M.E., Reich, R.K., Lamture, J.B., Beattie, K.L., Hollis, M.A., Ehrilich, D.J., Kosicki, B.B., Shumaker, J.M., Varma, R.S., Burke, B.E., Murphy, A., and Rathman, D.D., (1993), Advances in DNA Sequencing Technology, Proc. SPIE, 1891, 13-26). Two implementations of the technology have been employed. The first involves direct attachment of the matrix to the surface of a CCD. The second involves attachment of the matrix to a disposible SiO2 coated chip, which is then placed face to face upon the CCD surface. As can be predicted from this favorable collection geometry and the known characteristics of a CCD, it is found that as measured by the time required to obtain equivalent signal to noise ratios, 32P detection speed by the direct CCD approach is at least 10 fold greater than can be obtained with a commercial gas phase array detector, and at least 100 fold greater than when X-ray film is used for 32P detection. Thus, it is shown that excellent quality hybridization signals can be obtained from a standard hybridization reaction, after only 1 second of CCD data acquisition.  相似文献   

13.
In this study we aimed at the development of a cytometric system for quantification of specific DNA sequences using fluorescence in situ hybridization (ISH) and digital imaging microscopy. The cytochemical and cytometric aspects of a quantitative ISH procedure were investigated, using human peripheral blood lymphocyte interphase nuclei and probes detecting high copy number target sequences as a model system. These chromosome-specific probes were labeled with biotin, digoxigenin, or fluorescein. The instrumentation requirements are evaluated. Quantification of the fluorescence ISH signals was performed using an epi-fluorescence microscope with a multi-wavelength illuminator, equipped with a cooled charge couple device (CCD) camera. The performance of the system was evaluated using fluorescing beads and a homogeneously fluorescing specimen. Specific image analysis programs were developed for the automated segmentation and analysis of the images provided by ISH. Non-uniform background fluorescence of the nuclei introduces problems in the image analysis segmentation procedures. Different procedures were tested. Up to 95% of the hybridization signals could be correctly segmented using digital filtering techniques (min-max filter) to estimate local background intensities. The choice of the objective lens used for the collection of images was found to be extremely important. High magnification objectives with high numerical aperture, which are frequently used for visualization of fluorescence, are not optimal, since they do not have a sufficient depth of field. The system described was used for quantification of ISH signals and allowed accurate measurement of fluorescence spot intensities, as well as of fluorescence ratios obtained with double-labeled probes.  相似文献   

14.
Classical banding methods provide basic information about the identities and structures of chromosomes on the basis of their unique banding patterns. Spectral karyotyping (SKY), and the related multiplex fluorescence in situ hybridization (M-FISH), are chromosome-specific multicolor FISH techniques that augment cytogenetic evaluations of malignant disease by providing additional information and improved characterization of aberrant chromosomes that contain DNA sequences not identifiable using conventional banding methods. SKY is based on cohybridization of combinatorially labeled chromosome-painting probes with unique fluorochrome signatures onto human or mouse metaphase chromosome preparations. Image acquisition and analysis use a specialized imaging system, combining Sagnac interferometer and CCD camera images to reconstruct spectral information at each pixel. Here we present a protocol for SKY analysis using commercially available SkyPaint probes, including procedures for metaphase chromosome preparation, slide pretreatment and probe hybridization and detection. SKY analysis requires approximately 6 d.  相似文献   

15.
We report on initial results of using a new direct detection device (DDD) for single particle reconstruction of vitreous ice embedded specimens. Images were acquired on a Tecnai F20 at 200 keV and a nominal magnification of 29,000×. This camera has a significantly improved signal to noise ratio and modulation transfer function (MTF) at 200 keV compared to a standard CCD camera installed on the same microscope. Control of the DDD has been integrated into Leginon, an automated data collection system. Using GroEL as a test specimen, we obtained images of ∼30 K particles with the CCD and the DDD from the same specimen sample using essentially identical imaging conditions. Comparison of the maps reconstructed from the CCD images and the DDD images demonstrates the improved performance of the DDD. We also obtained a 3D reconstruction from ∼70 K GroEL particles acquired using the DDD; the quality of the density map demonstrates the potential of this new recording device for cryoEM data acquisition.  相似文献   

16.
Epithelial cervical CaSki, SiHa and HeLa cells containing respectively 600 copies of human papillomavirus (HPV) DNA type 16, 1–2 copies of HPV DNA type 16 and 10–50 copies of HPV DNA type 18 were used as model to detect different quantities of integrated HPV genome. The HPV DNA was identified on cell deposits with specific biotinylated DNA probes either by enzymatic in situ hybridization (EISH) or fluorescence in situ hybridization (FISH) involving successively a rabbit anti-biotin antibody, a biotinylated goat anti-rabbit antibody and streptavidin-alkaline phosphatase complex or streptavidin-fluorescein isothiocyanate complex. With brightfield microscopy and EISH, hybridization spots were observed in CaSki and HeLa cells but hardly any in SiHa cells. With fluorescence microscopy and FISH, hybridization spots were clearly seen only on CaSki cell nuclei. In an attempt to improve the detection of low quantities of HPV DNA signals revealed by FISH, laser scanning confocal microscopy (LSCM) and quantitative microscopy with an intensified charge coupled device (CCD) camera were used. With both LSCM and quantitative microscopy, as few as 1–2 copies of HPV DNA were detected and found to be confined to cell nuclei counterstained with propidium iodide. Under Nomarski phase contrast, a good preservation of the cell structure was observed. With quantitative microscopy, differences in the number, size, total area and integrated fluorescence intensity of hybridization spots per nucleus were revealed between CaSki, SiHa and HeLa cells. Considered altogether our results shows that in situ hybridization is a powerful technique to detect small amounts of nucleic acid sequences but the choice of the technique for cell examination is important. Single genes of HPV were visualized most efficiently by association of FISH with LSCM or quantitative microscopy with an intensified CCD camera.  相似文献   

17.
Applications of direct detection device in transmission electron microscopy   总被引:1,自引:0,他引:1  
A prototype direct detection device (DDD) camera system has shown great promise in improving both the spatial resolution and the signal to noise ratio for electron microscopy at 120–400 keV beam energies (Xuong et al., 2007. Methods in Cell Biology, 79, 721–739). Without the need for a resolution-limiting scintillation screen as in the charge coupled device (CCD), the DDD camera can outperform CCD based systems in terms of spatial resolution, due to its small pixel size (5 μm). In this paper, the modulation transfer function (MTF) of the DDD prototype is measured and compared with the specifications of commercial scientific CCD camera systems. Combining the fast speed of the DDD with image mosaic techniques, fast wide-area imaging is now possible. In this paper, the first large area mosaic image and the first tomography dataset from the DDD camera are presented, along with an image processing algorithm to correct the specimen drift utilizing the fast readout of the DDD system.  相似文献   

18.
This study aims at the quantification of specific DNA sequences by using fluorescence in situ hybridization (ISH) and digital imaging microscopy. The cytochemical and cytometric aspects of a quantitative ISH procedure were investigated, using human peripheral blood lymphocyte interphase nuclei and probes detecting high copy number target sequences as a model system. These chromosome-specific probes were labeled with biotin, digoxigenin, or fluorescein. Quantification of the fluorescence ISH signals was performed using an epifluorescence microscope equipped with a multi-wavelength illuminator, and a cooled charge coupled device (CCD) camera. Specific image analysis programs were developed for the segmentation and analysis of the images provided by ISH. The fluorescence intensity distributions of the ISH spots showed large internuclear variation (CVs up to 65%) for the probes used. The variation in intensity was found to be independent of the probe, the type of labeling, and the type of immunocytochemical detection used. Variation in intensity was not caused primarily by the immunocytochemical detection method, since directly fluorescein-labeled probes showed similar internuclear variation. Furthermore, it was found that different white blood cell types, which harbor different degrees of compactness of the nuclear chromatin, showed the same variation. The intra-nuclear variation in intensity of the ISH spots on the two chromosome homologs within one nucleus was significantly smaller (approximately 20%) than the inter-nuclear variation, probably due to more constant local hybridization conditions. Due to the relatively small intranuclear variation, copy number polymorphisms of the satellite DNA sequence on chromosome 1 could readily be quantified.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Integrated human papillomavirus type 16 (HPV-16) DNA was directly visualized on metaphase chromosomes in the two human cervical carcinoma cell lines SiHa and CaSki by fluorescence in situ hybridization with a biotinylated DNA probe (7.9 kb). The fluorescence intensities of hybridization signals from single copies and dispersed clusters of integrated HPV-16 DNA were quantified using a microscope equipped with a cooled-CCD camera that was interfaced to an image processor and host computer. Hybridization signals were localized on chromosomes using separate, registered images of 4',6-diamidino-2-phenylindole (DAPI) or propidium iodide stained metaphase chromosome spreads. In both SiHa and CaSki spreads, a single fluorescein signal was observed on one or both chromatids of chromosome 13, which was identified by simultaneous hybridization with a biotinylated centromere probe specific for chromosomes 13 and 21. Ratios of the distance from 13pter to the HPV-16 signals to the entire chromosome length were approximately 0.63 +/- 0.05 in both SiHa and CaSki cells, indicating the possibility of a common integration domain on chromosome 13. In SiHa cells, no additional signals were observed on other chromosomes. This observation, taken together with literature reports that SiHa cells contain 1 to 2 copies of the HPV-16 genome in this region of chromosome 13, suggests that each fluorescein signal on chromosome 13 represents one equivalent of the HPV-16 genome. The total integrated fluorescence intensity in isolated CaSki metaphase chromosome spreads was approximately two orders of magnitude greater than that of a single copy of HPV-16 DNA in SiHa cells, indicating an increase in HPV-16 copy number.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Fluorescence lifetime imaging of calcium using Quin-2.   总被引:4,自引:0,他引:4  
We describe the use of a new imaging technology, fluorescence lifetime imaging (FLIM), for the imaging of the calcium concentrations based on the fluorescence lifetime of a calcium indicator. The fluorescence lifetime of Quin-2 is shown to be highly sensitive to [Ca2+]. We create two-dimensional lifetime images using the phase shift and modulation of the Quin-2 in response to intensity-modulated light. The two-dimensional phase and modulation values are obtained using a gain-modulated image intensifier and a slow-scan CCD camera. The lifetime values in the 2D image were verified using standard frequency-domain measurements. Importantly, the FLIM method does not require the probe to display shifts in the excitation or emission spectra, which may allow Ca2+ imaging using other Ca2+ probes not in current widespread use due to the lack of spectral shifts. Fluorescence lifetime imaging can be superior to stationary (steady-state) imaging because lifetimes are independent of the local probe concentration and/or intensity, and should thus be widely applicable to chemical imaging using fluorescence microscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号