首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A sensitive and enantioselective vancomycin chiral stationary phase high‐performance liquid chromatography–tandem mass spectrometry method was developed for the determination of trantinterol enantiomers in human plasma. Baseline resolution was achieved using the vancomycin chiral stationary phase known as Chirobiotic V with polar ionic mobile phase consisting of acetonitrile–methanol (60:40, v/v) containing 0.01% ammonia and 0.02% acetic acid at a flow rate of 1.0 mL/min. Waters Oasis HLB C18 solid phase extraction cartridges were used in the sample preparation of trantinterol samples from plasma. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization. The calibration curve was linear in a concentration range from 0.0606 to 30.3 ng/mL in plasma, with the lower limit of quantification of 0.0606 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 9.7% and the accuracy (relative error) was from ?6.6 to 7.2% at all quality control levels. The method was successfully applied to a study of stereoselective pharmacokinetics in human. Chirality 27:327–331, 2015.© 2015 Wiley Periodicals, Inc.  相似文献   

2.
Oxcarbazepine is a second‐generation antiepileptic drug indicated as monotherapy or adjunctive therapy in the treatment of partial seizures or generalized tonic–clonic seizures in adults and children. It undergoes rapid presystemic reduction with formation of the active metabolite 10‐hydroxycarbazepine (MHD), which has a chiral center at position 10, with the enantiomers (S)‐(+)‐ and R‐(?)‐MHD showing similar antiepileptic effects. This study presents the development and validation of a method of sequential analysis of oxcarbazepine and MHD enantiomers in plasma using liquid chromatography with tandem mass spectrometry (LC‐MS/MS). Aliquots of 100 μL of plasma were extracted with a mixture of methyl tert‐butyl ether: dichloromethane (2:1). The separation of oxcarbazepine and the MHD enantiomers was obtained on a chiral phase Chiralcel OD‐H column, using a mixture of hexane:ethanol:isopropanol (80:15:5, v/v/v) as mobile phase at a flow rate of 1.3 mL/min with a split ratio of 1:5, and quantification was performed by LC‐MS/MS. The limit of quantification was 12.5 ng oxcarbazepine and 31.25 ng of each MHD enantiomer/mL of plasma. The method was applied in the study of kinetic disposition of oxcarbazepine and the MHD enantiomers in the steady state after oral administration of 300 mg/12 h oxcarbazepine in a healthy volunteer. The maximum plasma concentration of oxcarbazepine was 1.2 µg/mL at 0.75 h. The kinetic disposition of MHD is enantioselective, with a higher proportion of the S‐(+)‐MHD enantiomer compared to R‐(?)‐MHD and an AUC0‐12 S‐(+)/R‐(?) ratio of 5.44. Chirality 25:897–903, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

3.
A convenient method using a fluorogenic agent, 4‐chloro‐7‐nitro‐1,2,3‐benzoxadiazole (NBD‐Cl), was developed for enantiomer separation of chiral aliphatic amines including amino alcohols by normal high‐performance liquid chromatography. The enantiomer separation of chiral aliphatic amines as NBD derivatives was performed on six covalently bonded and four coated‐type polysaccharide‐derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence detection (FLD). Among the covalently bonded CSPs, Chiralpak IE showed the best enantiomer separation for most analytes. The other CSPs also showed good enantioselectivity except for Chiralpak IB. On the other hand, Chiralpak AD‐H and Amylose‐1 generally exhibited better enantiomer separation of NBD derivatized chiral amines among the coated CSPs. The developed analytical technique was also applied to determine the optical purity of commercially available (R)‐ and (S)‐leucinol; the impurity was found to be 0.06%. The developed method was validated and proved to be an accurate, precise, sensitive, and selective method suitable for separation of chiral aliphatic amines as NBD derivatives under simultaneous UV and FLD.  相似文献   

4.
A sensitive and specific method for the simultaneous determination of the enantiomeric purity of 2,6‐dimethylphenoxyacetyl derivatives as trans or cis racemic and enantiomeric forms with 2‐ or 4‐aminocyclohexanol moiety ( 1 , 2 , 3 , 6 ) and their amine analogs ( 8 , 9 ) was developed. The compounds studied are known for their anticonvulsant activity and the most interesting pharmacological results were those for (±)‐trans‐2‐(2,6‐dimethylphenoxy)‐N‐(2‐hydroxycyclohexyl)acetamide ( 1 ) as well as (±)‐trans‐2‐[(2,6‐dimethylphenoxy)ethyl]aminocyclohexanol ( 8 ). The analytical method for determining the enantiomeric purity of the compounds studied is based on direct separation of the analytes using a chiral stationary phase (Chiralpak AS column). The mass spectrometric analysis was done on a coupled liquid chromatograph–mass spectrometer system with an electrospray ionization source (LC/ESI‐MS). For the compounds 1 , 8 , and 9 , the method allows an excellent separation of enantiomers, with a resolution higher than 3.2, and a tailing factor of less than 1.67 with a final enantiomer purity better than 97.5%. Chirality 26:144–149, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

5.
An indirect reversed‐phase high‐performance liquid chromatographic separation and fluorescence detection of sitagliptin enantiomers in rat plasma was developed and validated. Deproteinized rat plasma containing racemic sitagliptin was derivatized with o‐phthalaldehyde and N‐acetyl‐L‐cysteine under alkaline conditions, converted to diastereomers, and separated on a Lichrospher 100 RP‐18e column using 20 mM phosphate buffer and methanol (45:55 v/v) as a mobile phase under isocratic mode of elution at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 330 and 450 nm as excitation and emission wavelengths, respectively. The method was linear in the range of 50–5000 ng/ mL for both enantiomers. The intra‐ and interday accuracy and precision were within the predefined limits of ≤15% at all concentrations. The method was successfully applied to a pharmacokinetic study of sitagliptin after 5 mg/kg oral administration to Wistar rats. Robustness of the method was evaluated using design of experiments. Chirality 25:883–889, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

6.
Chiral pesticide enantiomers often show different bioactivity and toxicity; however, this property is usually ignored when evaluating their environmental and public health risks. Hexaconazole is a chiral fungicide used on a variety of crops for the control of many fungal diseases. This use provides opportunities for the pollution of food and soil. In this study, a sensitive and convenient chiral liquid chromatography coupled with tandem mass spectrometry (LC‐MS/MS) method was developed and validated for measuring hexaconazole enantiomers in tomato, cucumber, and soil. Separation was by a reversed‐phase Chiralcel OD‐RH column, under isocratic conditions using a mixture of acetonitrile‐2 mM ammonium acetate in water (60/40, v/v) as the mobile phase at a flow rate of 0.4 mL/min. Parameters including the matrix effect, linearity, precision, accuracy and stability were undertaken. Then the proposed method was successfully applied to investigate the possible enantioselective degradation of rac‐hexaconazole in plants (tomato and cucumber) and soil under field conditions. The degradation of the two enantiomers of hexaconazole proved to be enantioselective and dependent on the media: The (+)‐enantiomer showed a faster degradation in plants, while the (?)‐enantiomer dissipated faster than the (+)‐form in field soil, resulting in relative enrichment of the opposite enantiomer. The results of this work demonstrate that both the environmental media and environmental conditions influenced the direction and rate of enantioselective degradation of hexaconazole. Chirality 25:160–169, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

7.
A robust and validated liquid-liquid extraction LC-MS/MS method was developed for population pharmacokinetic analysis and therapeutic drug monitoring of risperidone and the enantiomers of its major active metabolite (+)-and (-)9-hydroxyrisperidone in pediatric patients. The method was rapid, sensitive and used a low sample amount (200 microL), which is very desirable for the pediatric population. The assay was validated from 0.2 to 50 ng/mL in plasma for all analytes. LLOQ for all analytes was 0.2 ng/mL. The extracts were analyzed by normal phase LC-MS/MS. The sample run time was 8 min. Intra- and interday precision for all analytes was < or =6%; method accuracy was between 89 and 99%. Additional experiments were performed to analyze matrix effects and identify a proper internal standard for each analyte. The validated method was used to study risperidone and its enantiomer metabolites in plasma as part of a population pharmacokinetic study in pediatric patients with pervasive developmental disorder (PDD).  相似文献   

8.
A sensitive and specific high-performance liquid chromatographic method has been developed for the simultaneous determination of the enantiomers of pazinaclone (DN-2327), a new anxiolytic agent, and those of its active metabolite, M-II, in rat plasma. Organic solvent extraction of pazinaclone, M-II, and internal standard (I.S.) in plasma was followed by separation of the analytes from other metabolites using an achiral reversed-phase column. Fluorescence detection was employed with excitation and emission wavelengths of 328 and 367 nm, respectively. Separation of all the enantiomers and I.S. was then accomplished with normal- and chiral-phase columns connected in series. For each analyte, the lower quantitation limit was 0.5 ng/ml. The assay has been applied to a chiral inversion study in rats. Chiral conversion from one enantiomer of pazinaclone to the other hardly occurred. This method is suitable for enantioselective pharmacokinetic and toxicokinetic studies in animals.  相似文献   

9.
Enantioseparation of the antidiarrheal drug, racecadotril, was investigated by liquid chromatography using polysaccharide‐type chiral stationary phases in polar organic mode. The enantiodiscrimininating properties of 4 different chiral columns (Chiralpak AD, Chiralcel OD, Chiralpak AS, Chiralcel OJ) with 5 different solvents (methanol, ethanol, 1‐propanol, 2‐propanol, and acetonitrile) at 5 different temperatures (5–40 °C) were investigated. Apart from Chiralpak AS column the other 3 columns showed significant enantioseparation capabilities. Among the tested mobile phases, alcohol type solvents were superior over acetonitrile, and significant differences in enantioselective performance of the selector were observed depending on the type of alcohol employed. Van't Hoff analysis was used for calculation of thermodynamic parameters which revealed that enantioseparation is mainly enthalpy controlled; however, enthropic control was also observed. Enantiopure standard was used to determine the enantiomer elution order, revealing chiral selector—and mobile‐phase dependent reversal of enantiomer elution order. Using the optimized method (Chiralcel OJ stationary phase, thermostated at 10 °C, 100% methanol, flow rate: 0.6 mL/min) baseline separation of racecadotril enantiomers (resolution = 3.00 ± 0.02) was achieved, with the R‐enantiomer eluting first. The method was validated according to the ICH guidelines, and its application was tested on capsule and granules containing the racemic mixture of the drug.  相似文献   

10.
A simple and innovative assay is described which allows the chiral separation of the four enantiomers of fluoxetine and norfluoxetine, with performance characteristics adequate for therapeutic drug monitoring. The assay requires liquid-liquid extraction into acetonitrile/n-hexane/isopropylic alcohol and re-extraction into phosphoric acid for clean-up. The acidic layer is injected onto the HPLC system after filtering. Separation of the analytes is achieved with a Chiralcel ODR column and a mobile phase consisting of potassium hexafluorophosphate/acetonitrile. Detection is made by ultraviolet absorbance at 227 nm. Standard curves are linear for each enantiomer (r(2)>/=0.992) over the range of 10-1000 ng/ml with a limit of quantification of 10 ng/ml for each enantiomer. Within-day and between-day CV% are 相似文献   

11.
A sensitive and high‐throughput chiral liquid chromatography–tandem mass spectrometry method was developed and validated for the quantification of R‐pantoprazole and S‐pantoprazole in human plasma. Sample extraction was carried out by using ethyl acetate liquid–liquid extraction in 96‐well plate format. The separation of pantoprazole enantiomers was performed on a CHIRALCEL OJ‐RH column and an overlapping injection mode was used to achieve a run time of 5.0 min/sample. The mobile phase consisted of 1) 10 mM ammonium acetate in methanol: acetonitrile (1:1, v/v) and 2) 20 mM ammonium acetate in water. Isocratic elution was used with flow rate at 500 μL/min. The enantiomers were quantified on a triple‐quadrupole mass spectrometer under multiple reaction monitoring (MRM) mode with m/z 382.1/230.0 for pantoprazole and m/z 388.4/230.1 for pantoprazole‐d7. Linearity from 20.0 to 5000 ng/mL was established for each enantiomer (r2 > 0.99). Extraction recovery ranged from 91.7% to 96.4% for R‐pantoprazole and from 92.5% to 96.5% for S‐pantoprazole and the IS‐normalized matrix factor was 0.98 to 1.07 for R‐pantoprazole and S‐pantoprazole, respectively. The method was demonstrated with acceptable accuracy, precision, selectivity, and stability and the method was applied to support a pharmacokinetic study of a phase I clinical trial of racemic pantoprazole in healthy Chinese subjects. Chirality 28:569–575, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

12.
A gas chromatographic–mass spectrometric method was developed for the enantioselective analysis of levetiracetam and its enantiomer (R)-α-ethyl-2-oxo-pyrrolidine acetamide in dog plasma and urine. A solid-phase extraction procedure was followed by gas chromatographic separation of the enantiomers on a chiral cyclodextrin capillary column and detection using ion trap mass spectrometry. The fragmentation pattern of the enantiomers was further investigated using tandem mass spectrometry. For quantitative analysis three single ions were selected from the enantiomers, enabling selected ion monitoring in detection. The calibration curves were linear from 1 μM to 2 mM for plasma samples and from 0.5 mM to 38 mM for urine samples. In plasma and urine samples the inter-day precision, expressed as relative standard deviation was around 10% in all concentrations. Selected ion monitoring mass spectrometry is suitable for quantitative analysis of a wide concentration range of levetiracetam and its enantiomer in biological samples. The method was successfully applied to a pharmacokinetic study of levetiracetam and (R)-α-ethyl-2-oxo-pyrrolidine acetamide in a dog.  相似文献   

13.
Introduction – Biflavones of Hypericum perforatum L. are bioactive compounds used in the treatment of inflammation and depression. Determination of amentoflavone and biapigenin from blood is challenging owing to their similar structures and low concentrations. Objective – To develop a rapid, sensitive and accurate method based on liquid‐phase extraction followed by high‐performance liquid chromatography and electrospray ionisation mass spectrometry (HPLC‐ESI‐MS) for quantification of biflavones in human plasma. Methodology – After extraction from blood, the analytes were subjected to HPLC with an XTerra® MS C18 column and a binary mobile phase consisting of 2% formic acid in water and acetonitrile under isocratic elution conditions, with ESI‐MS detection in the negative ion mode and multiple reaction monitoring (MRM). Results – Both calibration curves showed good linearity within the concentration range 1–500 ng/mL. Limits of detection (S/N = 3) were 0.1 ng for pure substances and the limits of quantitation (S/N = 5) were 1.0 ng/mL from analyte‐spiked serum. The grand mean recovery was 90% from several subsamples of each biflavone. The imprecision (RSD) of peak areas was between 5% (intraday) and 10% (interday) for high concentrations (250 ng/mL) and between 10% (intraday) and 15% (interday) for low concentrations (1 ng/mL). Inaccuracy of the mean was less than 20% at the lower limit of quantitation. Conclusion – The developed and validated method for determination of biflavones from human plasma was effectively applied to pharmacokinetic studies of 13 probands and preliminary results indicate biphasic concentration–time curves. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Metoprolol is available for clinical use as a racemic mixture. The S‐(?)‐metoprolol enantiomer is the one expressing higher activity in the blockade of the β1‐adrenergic receptor. The α‐hydroxymetoprolol metabolite also has activity in the blockade of the β1‐adrenergic receptor. The present study describes the development and validation of a stereoselective method for sequential analysis of metoprolol and of α‐hydroxymetoprolol in plasma using high‐performance liquid chromatography with tandem mass spectrometry (LC‐MS/MS). 1‐ml aliquots of plasma were extracted with dichloromethane : diisopropyl ether (1:1, v/v). Metoprolol enantiomers and α‐hydroxymetoprolol isomers were separated on a Chiralpak AD column (Daicel Chemical Industries, New York, NY, USA) and quantitated by LC‐MS/MS. The limit of quantitation obtained was 0.2 ng of each metoprolol enantiomer/ml plasma and 0.1 ng/ml of each α‐hydroxymetoprolol isomer/ml plasma. The method was applied to the study of kinetic disposition of metoprolol in plasma samples collected up to 24 h after the administration of a single oral dose of 100‐mg metoprolol tartrate to a hypertensive parturient with a gestational age of 42 weeks. The clinical study showed that the metoprolol pharmakokinetics is enantioselective, with the observation of higher area under the curve (AUC)0?∞ values for S‐(?)‐metoprolol (AUCS‐(?)/AUCR‐(+) = 1.81) and the favoring of the formation of the new chiral center 1′R of α‐hydroxymetoprolol (AUC0?∞1′R/1′S = 2.78). Chirality, 25:1–7, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

15.
Metalaxyl is an important chiral acetanilide fungicide, and the activity almost entirely originates from the R‐enantiomer. Racemic metalaxyl has been gradually replaced by the enantiopure R‐enantiomer (metalaxyl‐M). In this study a chiral residue analysis method for metalaxyl and the metabolite metalaxyl acid was set up based on high‐performance liquid chromatography tandem mass spectroscopy (HPLC‐MS/MS). The enantioselective degradation and chiral stability of metalaxyl‐M in tomato fruits in two geographically distinct regions of China (Heilongjiang and Hunan Province) were evaluated and the enantioselectivity of metalaxyl acid was also investigated. Tomato plants grew under field conditions with a one‐time spray application of metalaxyl‐M wettable powder. It was found that R‐metalaxyl was not chirally stable and the inactive S‐metalaxyl was detected in tomato fruits. At day 40, S‐metalaxyl derived from R‐metalaxyl accounted for 32% and 26% of the total amount of metalaxyl, respectively. The metabolites R‐metalaxyl acid and S‐metalaxyl acid were both observed in tomato, and the ratio of S‐metalaxyl acid to the sum of S‐ and R‐metalaxyl acid was 36% and 28% at day 40, respectively. For both metalaxyl and metalaxyl acid, the half‐life of the S‐enantiomer was longer than the R‐enantiomer. The results indicated that the enantiomeric conversion should be considered in the bioactivity evaluation and environmental pollution assessment. Chirality 28:382–386, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

16.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of serial chiral novel anticholinergic compounds of phencynonate in rat plasma. After a simple protein-precipitation using methanol, the post-treatment samples were separated on a CAPCELL UG120 column with a mobile phase of a mixture of methanol and water (35:65) containing 0.1% formic acid. The serial chiral analytes and internal standard (IS) were all detected by the use of selected reaction monitoring mode (SRM). The method of all serial chiral analytes developed was validated in rat plasma with a daily working range of 0.5-100 ng/ml with correlation coefficient, R(2) > or = 0.99 and a sensitivity of 0.5 ng/ml as lower limit of quantification, respectively. This method was fully validated for the accuracy, precision and stability studies for all serial chiral analytes. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of serial chiral novel anticholinergic compounds of phencynonate in rat plasma.  相似文献   

17.
The enantioselective composition of the amphetamines is of interest, as the enantiomers show differences in their pharmacological effects and several methods for chiral separation of amphetamines have been described. Only a few methods have used whole blood as matrix and none of these separates both classic amphetamines (amphetamine and methamphetamine) and designer amphetamines (MDA, MDMA and MDEA). The aim of this study was, therefore, to develop a method for enantioselective analysis of AM, MA, MDA, MDMA, and MDEA in whole blood. The amphetamines were extracted from 0.5 g of whole blood by liquid-liquid extraction. After derivatization with R-MTPCl, the resulting diastereomers were separated by GC on a HP-5MS column and detected by SIM-MS. R-MTPCl was used as derivatization reagent because of the stability of this reagent and good separation of these analytes. Through the method, development time and temperature of the derivatization were optimized, and by admixture of 0.02% triethylamine it became possible to detect the amphetamines in adequately low concentrations as more analytes were derivatized. The method was validated and it was linear from 0.004 to 3 microg/g per enantiomer. The accuracy was within 91-115%, while the repeatability and reproducibility were < or =15% R.S.D. A method suitable for enantioselective separation and analysis of the amphetamines has been achieved, and the method was applied to analysis of whole blood samples originating from traffic and criminal cases and post mortem cases.  相似文献   

18.
Enantioselective separation methods and the enantioselective determination of the anti-allergic drug azelastine and of three of its main phase I metabolites in a biological matrix underwent chromatographic and electrophoretic investigations. An enantioselective assay of a coupling of HPLC using a beta-cyclodextrin chiral stationary phase to ionspray tandem mass spectrometry is presented. Additionally, this assay is compared to another enantioselective assay using electrokinetic capillary chromatography with beta-cyclodextrin and carboxymethyl-beta-cyclodextrin in polyacrylamide-coated capillaries. For capillary electrophoresis (CE) the importance of polyacrylamide coating for the validation of this separation method is highlighted. Extracted rat plasma samples of enantioselective metabolism studies were measured by both validated assays. Differences in the pharmacokinetics and pharmacodynamics were evaluated for the main substance azelastine and its main metabolite demethylazelastine. So, a first hint about the enantioselectivity of biotransformation of azelastine in rats was seen after oral application of either enantiomer or the racemate to rats.  相似文献   

19.
The chiral inversion and pharmacokinetics of two enantiomers of trantinterol, a new β2 agonist, were studied in rats dosed (+)‐ or (?)‐trantinterol separately. Plasma concentrations of (+)‐ and (?)‐trantinterol were measured by chiral stationary phase liquid chromatography tandem mass spectroscopy (LC‐MS/MS). The apparent inversion ratio was calculated as the ratio of AUC0‐t of (?)‐trantinterol or (+)‐trantinterol inverted from their antipodes to the sum of the AUC0‐t of (?)‐ and (+)‐trantinterol. Following single intravenous administration, both given enantiomers declined in similar plasma concentrations, suggesting that the two enantiomers have approximately the same disposition kinetics by the route of intravenous administration. However, after single oral administration, plasma concentrations of uninverted (?)‐trantinterol at many timepoints were significantly higher than those of uninverted (+)‐trantinterol, suggesting that the two enantiomers undergo apparently different absorption or metabolism after oral administration. Significant bidirectional chiral inversion occurred after intravenous and oral administration of (+)‐ or (?)‐trantinterol. After dosing with optically pure enantiomer, the concentration of the administered enantiomer predominated in vivo. The AUC0‐36 of (+)‐trantinterol after intravenous and oral dosing of (?)‐trantinterol were 16.6 ± 5.2 and 33.3 ± 16%, respectively of those of total [(+) + (?)] trantinterol. The AUC0‐36 of (?)‐trantinterol after intravenous and oral dosing of (+)‐trantinterol were 19.6 ± 8.8 and 37.9 ± 4.5%, respectively, of those of total [(?) + (+)] trantinterol. After intravenous administration of (+)‐ and (?)‐trantinterol the chiral inversion ratios of the two enantiomers were not significantly different and similar results were found for oral administration. The extent of chiral inversion after intravenous administration was apparently lower, indicating that the bidirectional chiral inversion was not only systemic but also presystemic. Chirality 25:934–938, 2013.© 2013 Wiley Periodicals, Inc.  相似文献   

20.
Vinclozolin is a chiral fungicide with potential environmental problems. The chiral separation of the enantiomers and enantioselective degradation in soil were investigated in this work. The enantiomers were separated by high‐performance liquid chromatography (HPLC) on Chiralpak IA, IB, and AZ‐H chiral columns under normal phase and the influence of the mobile phase composition on the separation was also studied. Complete resolutions were obtained on all three chiral columns under optimized conditions with the same elution order of (+)/(?). The residual analysis of the enantiomers in soil was conducted using accelerate solvent extraction followed by HPLC determination. The recoveries of the enantiomers ranged from 85.7–105.7% with relative standard deviation (SD) of 0.12–3.83%, and the limit of detection (LOD) of the method was 0.013 µg/g. The results showed that the degradations of vinclozolin enantiomers in the soils followed first‐order kinetics. Preferential degradation of the (?)‐enantiomer was observed only in one soil with the largest |ES| value of 0.047, and no obvious enantioselective degradation was observed in other soils. It was found that the persistence of vinclozolin in soil was related to pH values based on the half‐lives. The two enantiomers disappeared about 8 times faster in basic soils than that in neutral or acidic soils. Chirality 26:155–159, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号