首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In vivo 1H magnetic resonance spectroscopy (MRS) can be used to directly monitor brain ethanol. Previously, studies of human subjects have lead to the suggestion that the ethanol methyl 1H MRS signal intensity relates to tolerance to ethanol’s intoxicating effects. More recently, the ethanol 1H MRS signal intensity has been recognized to vary between brain gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) due to differences in T2 within these environments. The methods presented here extend ethanol MRS techniques to non-human primate subjects. Twelve monkeys were administered ethanol while sedated and positioned within a 3T MRI system. Chemical shift imaging (CSI) measurements were performed following intravenous infusion of 1 g/kg ethanol. Magnetic resonance imaging (MRI) data were also recorded for each monkey to provide volume fractions of GM, WM, and CSF for each CSI spectrum. To estimate co-variance of ethanol MRS intensity with GM, WM, and CSF volume fractions, the relative contribution of each tissue subtype was determined following corrections for radiofrequency pulse profile non-uniformity, chemical shift artifacts, and differences between the point spread function in the CSI data and the imaging data. The ethanol MRS intensity per unit blood ethanol concentration was found to differ between GM, WM, and CSF. Individual differences in MRS intensity were larger in GM than WM. This methodology demonstrates the feasibility of ethanol MRS experiments and analysis in non-human primate subjects, and suggests GM may be a site of significant variation in ethanol MRS intensity between individuals.  相似文献   

2.
Access to metabolic information in vivo using magnetic resonance (MR) technologies has generally been the niche of MR spectroscopy (MRS) and spectroscopic imaging (MRSI). Metabolic fluxes can be studied using the infusion of substrates labeled with magnetic isotopes, with the use of hyperpolarization especially powerful. Unfortunately, these promising methods are not yet accepted clinically, where fast, simple, and reliable measurement and diagnosis are key. Recent advances in functional MRI and chemical exchange saturation transfer (CEST) MRI allow the use of water imaging to study oxygen metabolism and tissue metabolite levels. These, together with the use of novel data analysis approaches such as machine learning for all of these metabolic MR approaches, are increasing the likelihood of their clinical translation.  相似文献   

3.
The ability to accurately and noninvasively quantify fatty infiltration in organs such as the liver and the pancreas remains a critical component in understanding the link between obesity and its comorbidities such as type 2 diabetes and fatty liver disease. Single‐voxel (1H) proton magnetic resonance spectroscopy (MRS) has long been regarded as the gold‐standard noninvasive technique for such measurements. Recent advances in three‐dimensional fat–water magnetic resonance imaging (MRI) methods have led to the development of rapid, robust, and quantitative approaches that can accurately characterize the proportion of fat and water content in underlying tissues across the full imaging volume, and hence entire organs of interest. One such technique is called IDEAL (Iterative Decomposition with Echo Asymmetry and Least squares estimation). This article prospectively compares three‐dimensional (3D) IDEAL‐MRI and single‐voxel MRS in the assessment of hepatic (HFF) and pancreatic fat fraction (PFF) in 16 healthy subjects. MRS acquisitions took 3–4 min to complete whereas IDEAL acquisitions were completed in 20‐s breath‐holds. In the liver, there was a strong correlation (slope = 0.90, r2 = 0.95, P < 0.001) between IDEAL and MRS‐based fat fractions. In the pancreas, a poorer agreement between IDEAL and MRS was observed (slope = 0.32, r2 = 0.51, P < 0.02). The discrepancy of PFF is likely explained by MRS signal contamination from surrounding visceral fat, presumably during respiratory motion. We conclude that IDEAL is equally accurate in characterizing hepatic fat content as MRS, and is potentially better suited for fat quantification in smaller organs such as the pancreas.  相似文献   

4.
Li C  Ling X  Liu S  Xu A  Zhang Y  Xing S  Pei Z  Zeng J 《BMC neurology》2011,11(1):49

Background  

Traditional magnetic resonance (MR) imaging can identify abnormal changes in ipsilateral thalamus in patients with unilateral middle cerebral artery (MCA) infarcts. However, it is difficult to demonstrate these early changes quantitatively. Diffusion tensor imaging (DTI) and proton magnetic resonance spectroscopy (MRS) are potentially sensitive and quantitative methods of detection in examining changes of tissue microstructure and metabolism. In this study, We used both DTI and MRS to examine possible secondary damage of thalamus in patients with corona radiata infarction.  相似文献   

5.
High-intensity focused ultrasound (HIFU) is a rapidly developing, non-invasive technique for local treatment of solid tumors that produce coagulative tumor necrosis. This study is aimed to investigate the feasibility of proton magnetic resonance spectroscopy (MRS) on early assessing treatment of HIFU ablation in rabbit with VX2 liver tumor. HIFU ablation was performed on normal liver and VX2 tumor in rabbit, and MRS was performed on normal liver and VX2 tumor before and 2 days after 100% HIFU ablation or 80% ablation in tumor volume. Choline (Cho) and choline/lipid (Cho/Lip) ratios between complete and partial HIFU ablation of tumor were compared. Tissues were harvested and sequentially sliced to confirm the necrosis. In normal liver, the Cho value liver was not obviously changed after HIFU (P > .05), but the Cho/Lip ratio was decreased (P < .05). Cho in liver VX2 tumor was much higher than that in normal liver (P < .001). Cho and Cho/Lip ratio were significantly decreased in tumor after complete HIFU ablation and partial HIFU ablation, and the Cho value in complete HIFU tumor ablation did not show any difference from that in normal liver after HIFU (P > .05); however, the Cho value in partial ablation was still higher than that in normal liver before or in tumor after complete HIFU treatment due to the residual part of tumors, and Cho/Lip ratio is lower than that in complete HIFU treatment (P < .001). The changes in MRS parameters were consistent with histopathologic changes of the tumor tissues after treatment. MRS could differentiate the complete tumor necrosis from residual tumor tissue, when combined with magnetic resonance imaging. We conclude that MRS may be applied as an important, non-invasive biomarker for monitoring the thoroughness of HIFU ablation.  相似文献   

6.
The purpose of this study was to evaluate the sensitivity of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), diffusion-weighted (DW)-MRI, in vivo MR spectroscopy (MRS), and ex vivo high-resolution magic angle spinning (HR MAS) MRS for the detection of early treatment effects after docetaxel administration. Docetaxel is an antitumor agent that leads to mitotic arrest, apoptosis, and mitotic catastrophe cell death. Gene expression analysis was performed to detect altered regulation in gene expression pathways related to docetaxel treatment effects. Histopathology was used as a measure of alterations in apoptosis and proliferation due to docetaxel. Experiments were performed using MCF7 mouse xenografts, randomized into a docetaxel (30 mg/kg) treatment group and a control group given saline. MRI/MRS was performed 1 day before treatment and 1, 3, and 6 days after treatment. Parametric images of the extracellular extravascular volume fraction (ve) transfer constant (Ktrans) and the apparent diffusion coefficient (ADC) were calculated from the DCE-MRI and DW-MRI data. Biopsies were analyzed by HR MAS MRS, and histopathology and gene expression profiles were determined (Illumina). A significant increase in the ADC 3 and 6 days after treatment and a significant decrease in total choline and a higher ve were found in treated tumors 6 days after treatment. No significant difference was found in the Ktrans between the two groups. Our results show that docetaxel induces apoptosis and decreases proliferation in MCF7 xenografts. Further, these phenomena can be monitored by in vivo MRS, DW-MRI, and gene expression.  相似文献   

7.
8.
A novel approach to understanding the pathophysiology of schizophrenia has been the investigation of membrane composition and functional perturbations, referred to as the "Membrane Hypothesis of Schizophrenia." The evidence in support of this hypothesis has been accumulating in findings in patients with schizophrenia of reductions in phospholipids and essential fatty acids various peripheral tissues. Postmortem studies indicate similar reductions in essential fatty acids in the brain. However, the use of magnetic resonance spectroscopy (MRS) has provided an opportunity to examine aspects of membrane biochemistry in vivo in the living brain. MRS is a powerful, albeit complex, noninvasive quantitative imaging tool that offers several advantages over other methods of in vivo biochemical investigations. It has been used extensively in investigating brain biochemistry in schizophrenia. Phosphorus MRS (31P MRS) can provide important information about neuronal membranes, such as levels of phosphomonoesters that reflect the building blocks of neuronal membranes and phosphodiesters that reflect breakdown products. 31P MRS can also provide information about bioenergetics. Studies in patients with chronic schizophrenia as well as at first episode prior to treatment show a variety of alterations in neuronal membrane biochemistry, supportive of the membrane hypothesis of schizophrenia. Below, we will briefly review the principles underlying 31P MRS and findings to date. Magnetic resonance spectroscopy (MRS) is a powerful, albeit complex, imaging tool that permits investigation of brain biochemistry in vivo. It utilizes the magnetic resonance imaging hardware. It offers several advantages over other methods of in vivo biochemical investigations. MRS is noninvasive, there is no radiation exposure, does not require the use of tracer ligands or contrast media. Because of it is relatively benign, repeated measures are possible. It has been used extensively in investigating brain biochemistry in schizophrenia.  相似文献   

9.
Mutations in the isocitrate dehydrogenase (IDH) genes are frequently found in gliomas and in a fraction of acute myeloid leukemia patients. This results in the production of an oncometabolite, 2-hydroxyglutarate (2-HG). Glioma patients harboring IDH mutations have a longer survival than their wild-type counterparts. 2-HG has been detected noninvasively in gliomas with IDH mutations using magnetic resonance spectroscopy (MRS), suggesting its potential clinical relevance for identifying glioma subtypes with better prognosis. In this paper, the recent developments in the MRS detection of the 2-HG in gliomas are reviewed, including the therapeutic potentials and translational values.  相似文献   

10.
Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) have evolved as sensitive tools for anatomic and metabolic evaluation of breast cancer. In vivo MRS studies have documented the presence of choline containing compounds (tCho) as a reliable biochemical marker of malignancy and also useful for monitoring the tumor response to therapy. Recent studies on the absolute quantification of tCho are expected to provide cut-off values for discrimination of various breast pathologies. Addition of MRS investigation was also reported to increase the specificity of MRI. Further, ex vivo and in vitro MRS studies of intact tissues and tissue extracts provided several metabolites that were not be detected in vivo and provided insight into underlying biochemistry of the disease processes. In this review, we present briefly the role of various 1H MRS methods used in breast cancer research and their potential in relation to diagnosis, monitoring of therapeutic response and metabolism.  相似文献   

11.
Proton magnetic resonance spectroscopy (MRS) complements conventional methods used to differentiate intracranial cystic lesions. We report MRS findings of three cases that were diagnosed as pyogenic, tuberculous, and Cryptococcus abscesses before instituting any medical or surgical therapy. The pyogenic brain abscess had typical specific spectral findings (i.e., the demonstration of amino acids). Lactate and lipid peaks were visible in the tuberculous abscess. Cryptococcus neoformans can appear differently in different brain regions, which may lead to different spectral findings.  相似文献   

12.
磁共振波谱(MRS)信号可以在时域中采用全自动的暗箱方法或交互式方法进行量化。介绍了这两种方法的运算法则,并对MRS波谱数据进行了处理,得到了很好的结果。  相似文献   

13.
Vulnerable atherosclerotic plaques may be identified by their large lipid component, particularly liquid cholesteryl ester (CE), covered by a fibrous cap. We hypothesized that image-guided 1H proton magnetic resonance spectroscopy (MRS) would identify mobile CE in discrete, preselected regions of atherosclerotic plaque. Human carotid endarterectomy specimens (n = 10) were imaged ex vivo by magnetic resonance imaging (MRI) at high field (11.7 T) utilizing standard T1- and T2-weighted spin echo protocols. MRS spectra were acquired from 1 mm3 voxels, localized to plaque regions that we judged by MRI to be lipid rich or lipid poor. The spectra revealed methyl and methylene resonances of fatty acyl chains with relative intensities and linewidths characteristic of pure CE, by comparison with lipid standards. Regions judged to be lipid rich by MRI showed much more intense CE resonances than did lipid-poor regions. The integrated intensities of lipid peaks were 5.5 +/- 2.0% (lipid-rich regions) versus 0.9 +/- 0.6% (lipid-poor regions) of the unsuppressed water peak (P < 0.0001). Lipid distribution by histology, MRS, and MRI showed strong correlation. Image-guided proton MRS accurately identified CE in selected regions of atherosclerotic plaque as small as 1 mm3 in an ex vivo setting. This procedure may permit the noninvasive detection and quantification of CE in atherosclerotic plaque in vivo.  相似文献   

14.
目的:探讨磁共振波谱分析(MRS)与帕金森病(PD)HoehnYahr分级之间的相关性。方法:选择2016年9月-2017年8月我院收治的60例PD患者为研究对象,根据HoehnYahr分级将患者分为早期PD组32例、中期PD组18例、晚期PD组10例,并选择同时期在门诊进行健康体检的20例志愿者作为对照组。对各组研究对象的双侧基底节、双侧额叶、双侧丘脑区进行MRS,并分析PD患者HoehnYahr分级与MRS的关系。结果:晚期PD组双侧基底节、双侧额叶、双侧丘脑区NAA/Cr、NAA/Cho、Cho/Cr比值均低于中期PD组、早期PD组、对照组,且中期PD组低于早期PD组、对照组,早期PD组低于对照组,差异有统计学意义(P0.05)。通过Spearman相关性分析显示,MRS检测出PD患者NAA/Cr、NAA/Cho、Cho/Cr比值与HoehnYahr分级间呈负相关性(P0.05)。结论:MRS与PD患者的HoehnYahr分级具有负相关性,并且可通过MRS预测患者疾病的严重程度,以对其进行相应的治疗以及预后评估。  相似文献   

15.
We compared in vitro1H magnetic resonance spectroscopy (MRS) measurements of rat brain extracts (rats: 2–56 days old) with chromatographic measurements and in a further step also with results of in vivo MRS. The following substances can be reliably measured in brain extracts by in vitro MRS: N-acetylaspartate (NAA), total creatine (Cr), phosphorylethanoloamine (PE), taurine (Tau), glutamate (Glu), glutamine (Gln), -aminobutyrate (GABA) and alanine (Ala). Two different methods of MRS data evaluation compared with chromatographic data on Cr and NAA are shown. During development of the rat from day 2–56 brain concentrations of PE, Tau and Ala decrease, those of NAA, Cr, Glu and Gln increase, while GABA does not change. The developmental patterns of these substances are the same, whether measured by in vitro MRS or by chromatographic methods. Quantification of NAA, Cr, Tau, GABA and PE leads to the same results with both methods, while Glu, Gln and Ala concentrations determined by in vitro MRS are apparently lower than those measured chemically. The NAA/Cr ratios of 7 to 35-day-old rats were determined by in vivo1H MRS. These results correlate with chromatographic and in vitro data. Using appropriate methods in the in vivo and in vitro MR-technique, the obtained data compare well with the chromatographic results.  相似文献   

16.
Histology on a core or open biopsy is considered the gold standard for the diagnosis of tumours. While the non-invasive technique of magnetic resonance imaging can direct some of the decision diagnostic making, it has limitations and disadvantages, that can be partly overcome with the use of in vivo magnetic resonance spectroscopy (MRS). In vivo MRS is able to provide a specific biochemical profile on tumour tissue, compared with normal tissue. The capability of this technique is demonstrated here by the long-term development of hepatocellular carcinoma in an animal model. It allows the observation of the biochemical changes that occur in tumour tissue during its progression from preneoplastic nodules to hepatocellular carcinoma. Specifically the changes in the lipid profiles of tumour tissue at various stages of development are observed with proton (1H) MRS. Significant increases occurred in the lipid acyl chain methylene and methyl hydrogens during the early developmental stages of hepatocarcinogenesis, whereas during later stages associated with tumour development there was a significant increase in the levels of olefinic acyl chain hydrogens from unsaturated lipids. It is anticipated that this model will precede the application of the same technology to the non-invasive diagnosis and grading of human hepatocellular carcinoma.  相似文献   

17.

Object

The aim of this study was to determine the suitability of magnetic resonance spectroscopy (MRS) for screening brain tumors, based on a systematic review and meta-analysis of published data on the diagnostic performance of MRS.

Methods

The PubMed and PHMC databases were systematically searched for relevant studies up to December 2013. The sensitivities and specificities of MRS in individual studies were calculated and the pooled diagnostic accuracies, with 95% confidence intervals (CI), were assessed under a fixed-effects model.

Results

Twenty-four studies were included, comprising a total of 1013 participants. Overall, no heterogeneity of diagnostic effects was observed between studies. The pooled sensitivity and specificity of MRS were 80.05% (95% CI = 75.97%–83.59%) and 78.46% (95% CI: 73.40%–82.78%), respectively. The area under the summary receiver operating characteristic curve was 0.78. Stratified meta analysis showed higher sensitivity and specificity in child than adult. CSI had higher sensitivity and SV had higher specificity. Higher sensitivity and specificity were obtained in short TE value.

Conclusion

Although the qualities of the studies included in the meta-analysis were moderate, current evidence suggests that MRS may be a valuable adjunct to magnetic resonance imaging for diagnosing brain tumors, but requires selection of suitable technique and TE value.  相似文献   

18.

Purpose

To assess the ability of a polarization transfer (PT) magnetic resonance spectroscopy (MRS) technique to improve the detection of the individual phospholipid metabolites phosphocholine (PC), phosphoethanolamine (PE), glycerophosphocholine (GPC), and glycerophosphoethanolamine (GPE) in vivo in breast tumor xenografts.

Materials and Methods

The adiabatic version of refocused insensitive nuclei enhanced by polarization transfer (BINEPT) MRS was tested at 9.4 Tesla in phantoms and animal models. BINEPT and pulse-acquire (PA) 31P MRS was acquired consecutively from the same orthotopic MCF-7 (n = 10) and MDA-MB-231 (n = 10) breast tumor xenografts. After in vivo MRS measurements, animals were euthanized, tumors were extracted and high resolution (HR)-MRS was performed. Signal to noise ratios (SNRs) and metabolite ratios were compared for BINEPT and PA MRS, and were also measured and compared with that from HR-MRS.

Results

BINEPT exclusively detected metabolites with 1H-31P coupling such as PC, PE, GPC, and GPE, thereby creating a significantly improved, flat baseline because overlapping resonances from immobile and partly mobile phospholipids were removed without loss of sensitivity. GPE and GPC were more accurately detected by BINEPT in vivo, which enabled a reliable quantification of metabolite ratios such as PE/GPE and PC/GPC, which are important markers of tumor aggressiveness and treatment response.

Conclusion

BINEPT is advantageous over PA for detecting and quantifying the individual phospholipid metabolites PC, PE, GPC, and GPE in vivo at high magnetic field strength. As BINEPT can be used clinically, alterations in these phospholipid metabolites can be assessed in vivo for cancer diagnosis and treatment monitoring.  相似文献   

19.
The ability of probiotic Lactobacillus casei LA-1 for bacteriocin production using industrial by-products, such as whey, as supplement in growth medium has been demonstrated for the first time. Whey was investigated as a sole carbon source in cooperation with other components to substitute expensive nutrients as MRS for economical bacteriocin production. Industrial whey-supplemented MRS medium was then selected as to determine the effect of four variables (temperature, initial pH, incubation time, and whey concentration) by response surface methodology on bacteriocin production. Statistical analysis of results showed that two variables have a significant effect on bacteriocin production. Response surface data showed maximum bacteriocin production of 6,132.33?AU/mL at an initial pH of 7.12, temperature 34.29?°C, and whey concentration 13.74?g/L. The production of bacteriocin started during the exponential growth phase, reaching maximum values at stationary phase, and a biphasic growth and production pattern was observed. Our current work demonstrates that this approach of utilization of whey as substitution in costly medium as MRS has great promise for cost reduction in industry for the production of novel biological metabolic product that can be utilized as a food preservative.  相似文献   

20.
Limited potential of electroencephalogram (EEG), magnetic resonance images (MRI) and cerebrospinal fluid (CSF) test for 14-3-3 protein in the clinical diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD) resulted in developments in diagnostic premortem tehniques. Recent studies provided evidence that magnetic resonance spectroscopy (MRS) and measurement of total-tau (T-tau) and phospho-tau (P-tau) may be useful to identify patients with CJD. We combined detected metabolic changes in the brain by MRS and measured T-tau and tau-pT181 by ELISA, and tau-pT231 by Westernblot in a patient with autopsy proven sCJD. Our results show that in contrast to negative CSF 14-3-3 protein, nonspecific EEG and MRI, MRS revealed metabolic alterations in regions of the brain that has appeared normal on MRI, and tau tests has shown measurable levels of phosphorylated and non-phosphorylated isoforms in CSF. We conclude that rapidly progressive dementia with negative 14-3-3 test and non-specific initial EEG and MRI must still be considered in the differential diagnosis of the sCJD. Combination of serial functional MRI along with MRS study and measurement of tau ratio could improve the early diagnosis of sCJD. The current case is the first attempt to study results of the use of MRS and tau tests in a case of sCJD with diagnostic dilemma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号