首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The cellular cytoskeleton is crucial for many cellular functions such as cell motility and wound healing, as well as other processes that require shape change or force generation. Actin is one cytoskeleton component that regulates cell mechanics. Important properties driving this regulation include the amount of actin, its level of cross-linking, and its coordination with the activity of specific molecular motors like myosin. While studies investigating the contribution of myosin activity to cell mechanics have been performed on cells attached to a substrate, we investigated mechanical properties of cells in suspension. To do this, we used multiple probes for cell mechanics including a microfluidic optical stretcher, a microfluidic microcirculation mimetic, and real-time deformability cytometry. We found that nonadherent blood cells, cells arrested in mitosis, and naturally adherent cells brought into suspension, stiffen and become more solidlike upon myosin inhibition across multiple timescales (milliseconds to minutes). Our results hold across several pharmacological and genetic perturbations targeting myosin. Our findings suggest that myosin II activity contributes to increased whole-cell compliance and fluidity. This finding is contrary to what has been reported for cells attached to a substrate, which stiffen via active myosin driven prestress. Our results establish the importance of myosin II as an active component in modulating suspended cell mechanics, with a functional role distinctly different from that for substrate-adhered cells.  相似文献   

2.
High-throughput single cell analysis is required for understanding and predicting the complex stochastic responses of individual cells in changing environments. We have designed a microfluidic device consisting of parallel, independent channels with cell-docking structures for the formation of an array of individual cells. The microfluidic cell array was used to quantify single cell responses and the distribution of response patterns of calcium channels among a population of individual cells. In this device, 15 cell-docking units in each channel were fabricated with each unit containing 5 sandbag structures, such that an array of individual cells was formed in 8 independent channels. Single cell responses to different treatments in different channels were monitored in parallel to study the effects of the specific activator and inhibitor of the Ca2+ release-activated Ca2+ (CRAC) channels. Multichannel detection was performed to obtain the response patterns of the population of cells within this single cell array. The results demonstrate that it is possible to acquire single cell features in multichannels simultaneously with passive structural control, which provides an opportunity for high-throughput single cell response analysis in a microfluidic chip.  相似文献   

3.
We present for the first time a microfluidic cell culture array for long-term cellular monitoring. The 10 x 10 array could potentially assay 100 different cell-based experiments in parallel. The device was designed to integrate the processes used in typical cell culture experiments on a single self-contained microfluidic system. Major functions include repeated cell growth/passage cycles, reagent introduction, and real-time optical analysis. The single unit of the array consists of a circular microfluidic chamber, multiple narrow perfusion channels surrounding the main chamber, and four ports for fluidic access. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C. The observed doubling time was 1.4 +/- 0.1 days with a peak cell density of approximately 2.5*10(5) cells/cm(2). Cell assay was demonstrated by monitoring the fluorescence localization of calcein AM from 1 min to 10 days after reagent introduction. Confluent cell cultures were passaged within the microfluidic chambers using trypsin and successfully regrown, suggesting a stable culture environment suitable for continuous operation. The cell culture array could offer a platform for a wide range of assays with applications in drug screening, bioinformatics, and quantitative cell biology.  相似文献   

4.
A microfluidic array was constructed for trapping single cell and loading identical dynamic biochemical stimulation for gain a better understanding of Ca2+ signaling at single cell resolution in the present study. This microfluidic array consists of multiple radially aligned flow channels with equal intersection angles, which was designed by a combination of stagnation point flow and physical barrier. Numerical simulation results and trajectory analysis have shown the effectiveness of this single cell trapping device. Fluorescent experiment results demonstrated the effects of flow rate and frequency of dynamic stimulus on the profiles of biochemical concentration which exposed on captured cells. In this microarray, the captured single cells in each trapping channels were able to receive identical extracellular dynamic biochemical stimuli which being transmitted from the entrance in the middle of the microfluidic array. Besides, after loading dynamic Adenosine Triphosphate (ATP) stimulation on captured cells by this device, consistent average intracellular Ca2+ dynamics phase and cellular heterogeneity were observed in captured single K562 cells. Furthermore, this device is able to be used for investigating cellular respond on single cell resolution to temporally varying environments by modulating the stimulation signal in terms of concentration, pattern, and duration of exposure.  相似文献   

5.
We describe here a new in vitro protocol for structuring cardiac cell cultures to mimic important aspects of the in vivo ventricular myocardial phenotype by controlling the location and mechanical environment of cultured cells. Microlithography is used to engineer microstructured silicon metal wafers. Those are used to fabricate either microgrooved silicone membranes or silicone molds for microfluidic application of extracellular matrix proteins onto elastic membranes (involving flow control at micrometer resolution). The physically or microfluidically structured membranes serve as a cell culture growth substrate that supports cell alignment and allows the application of stretch. The latter is achieved with a stretching device that can deliver isotropic or anisotropic stretch. Neonatal ventricular cardiomyocytes, grown on these micropatterned membranes, develop an in vivo-like morphology with regular sarcomeric patterns. The entire process from fabrication of the micropatterned silicon metal wafers to casting of silicone molds, microfluidic patterning and cell isolation and seeding takes approximately 7 days.  相似文献   

6.
Thin layers of gels with mechanical properties mimicking animal tissues are widely used to study the rigidity sensing of adherent animal cells and to measure forces applied by cells to their substrate with traction force microscopy. The gels are usually based on polyacrylamide and their elastic modulus is measured with an atomic force microscope (AFM). Here we present a simple microfluidic device that generates high shear stresses in a laminar flow above a gel-coated substrate and apply the device to gels with elastic moduli in a range from 0.4 to 300 kPa that are all prepared by mixing two components of a transparent commercial silicone Sylgard 184. The elastic modulus is measured by tracking beads on the gel surface under a wide-field fluorescence microscope without any other specialized equipment. The measurements have small and simple to estimate errors and their results are confirmed by conventional tensile tests. A master curve is obtained relating the mixing ratios of the two components of Sylgard 184 with the resulting elastic moduli of the gels. The rigidity of the silicone gels is less susceptible to effects from drying, swelling, and aging than polyacrylamide gels and can be easily coated with fluorescent tracer particles and with molecules promoting cellular adhesion. This work can lead to broader use of silicone gels in the cell biology laboratory and to improved repeatability and accuracy of cell traction force microscopy and rigidity sensing experiments.  相似文献   

7.
A microfluidic device in polydimethylsiloxane (PDMS) consisting of an eight lines micro-injection array integrated in a base flow channel has been realized. The device is assembled from multiple PDMS parts, which have been moulded using notably micromachined masters in SU-8 photoresist. In contact with a planar substrate, up to eight independent laminar flow lines with cross-sections of 100 x 200 microm(2) can be generated. Dedicated for the application of pharmaceutical compounds to electrogenic cells in vitro, this device was tested with a neuronal cell line, Mz1-cells. These were cultured on lines of laminin deposited onto polystyrene substrates by microcontact printing. We were able to inject into this culture multiple lines of coloured PBS in parallel to the orientation of cellular growth. No mixing between the individual flow lines did occur.  相似文献   

8.
We present a novel microfabricated device to simultaneously and actively trap thousands of single mammalian cells in alignment with a planar microelectrode array. Thousands of 3 micromdiameter trapping electrodes were fabricated within the bottom of a parallel-plate flow chamber. Cells were trapped on the electrodes and held against destabilizing fluid flows by dielectrophoretic forces generated in the device. In general, each electrode trapped only one cell. Adhesive regions were patterned onto the surface in alignment with the traps such that cells adhered to the array surface and remained in alignment with the electrodes. By driving the device with different voltages, we showed that trapped cells could be killed by stronger electric fields. However, with weaker fields, cells were not damaged during trapping, as indicated by the similar morphologies and proliferation rates of trapped cells versus controls. As a test of the device, we patterned approximately 20000 cells onto a 1cm(2) grid of rectangular adhesive regions, with two electrodes and thus two cells per rectangle. Our method obtained 70+/-1% fidelity versus 17+/-1% when using an existing cell-registration technique. By allowing the placement of desired numbers of cells at specified locations, this approach addresses many needs to manipulate and register cells to the surfaces of biosensors and other devices with high precision and fidelity.  相似文献   

9.
We present a novel microfabricated device to simultaneously and actively trap thousands of single mammalian cells in alignment with a planar microelectrode array. Thousands of 3 Ipm diameter trapping electrodes were fabricated within the bottom of a parallel-plate flow chamber. Cells were trapped on the electrodes and held against destabilizing fluid flows by dielectrophoretic forces generated in the device.In general, each electrode trapped only one cell. Adhesive regions were patterned onto the surface in alignment with the traps such that cells adhered to the array surface and remained in alignment with the electrodes. By driving the device with different voltages, we showed that trapped cells could be killed by stronger electric fields. However, with weaker fields, cells were not damaged during trapping, as indicated by the similar morphologies and proliferation rates of trapped cells versus controls. As a test of the device, we patterned approximately 20,000 cells onto aI cm2 grid of rectangular adhesive regions, with two electrodes and thus two cells per rectangle. Our method obtained 70 +/- 1% fidelity versus 17 +/- 1% when using an existing cell-registration technique. By allowing the placement of desired numbers of cells at specified locations, this approach addresses many needs to manipulate and register cells to the surfaces of biosensors and other devices with high precision and fidelity.  相似文献   

10.
Here we detail the design, fabrication, and use of a microfluidic device to evaluate the deformability of a large number of individual cells in an efficient manner. Typically, data for ~102 cells can be acquired within a 1 hr experiment. An automated image analysis program enables efficient post-experiment analysis of image data, enabling processing to be complete within a few hours. Our device geometry is unique in that cells must deform through a series of micron-scale constrictions, thereby enabling the initial deformation and time-dependent relaxation of individual cells to be assayed. The applicability of this method to human promyelocytic leukemia (HL-60) cells is demonstrated. Driving cells to deform through micron-scale constrictions using pressure-driven flow, we observe that human promyelocytic (HL-60) cells momentarily occlude the first constriction for a median time of 9.3 msec before passaging more quickly through the subsequent constrictions with a median transit time of 4.0 msec per constriction. By contrast, all-trans retinoic acid-treated (neutrophil-type) HL-60 cells occlude the first constriction for only 4.3 msec before passaging through the subsequent constrictions with a median transit time of 3.3 msec. This method can provide insight into the viscoelastic nature of cells, and ultimately reveal the molecular origins of this behavior.  相似文献   

11.
The printing of cells for microarray applications possesses significant challenges including the problem of maintaining physiologically relevant cell phenotype after printing, poor organization and distribution of desired cells, and the inability to deliver drugs and/or nutrients to targeted areas in the array. Our 3D microfluidic printing technology is uniquely capable of sealing and printing arrays of cells onto submerged surfaces in an automated and multiplexed manner. The design of the microfluidic cell array (MFCA) 3D fluidics enables the printhead tip to be lowered into a liquid-filled well or dish and compressed against a surface to form a seal. The soft silicone tip of the printhead behaves like a gasket and is able to form a reversible seal by applying pressure or backing away. Other cells printing technologies such as pin or ink-jet printers are unable to print in submerged applications. Submerged surface printing is essential to maintain phenotypes of cells and to monitor these cells on a surface without disturbing the material surface characteristics. By printing onto submerged surfaces, cell microarrays are produced that allow for drug screening and cytotoxicity assessment in a multitude of areas including cancer, diabetes, inflammation, infections, and cardiovascular disease.  相似文献   

12.
用于药物筛选的微流控细胞阵列芯片   总被引:1,自引:0,他引:1  
细胞区域分布培养以及如何有效地对微流体进行操控是微流控阵列芯片在细胞药物研究中的关键技术。本研究介绍了一种利用SU-8负性光刻胶模具和PDMS制作双层结构的微流控细胞阵列芯片的方法,该芯片通过C型的坝结构将进样细胞拦截在芯片的细胞培养的固定区域,键合双层PDMS构成阀控制层,阀网络的开关作用成功实现了芯片通道内微流体的操控,同时芯片设计了药物浓度梯度网络,产生6个不同浓度的药物刺激细胞。通过对芯片3种共培养细胞活性的检测和药物伊立替康(CTP-11)对肝癌细胞的浓度梯度刺激等实验结果验证该芯片在细胞研究和药物筛选等方面的可行性。  相似文献   

13.
Electron spin resonance (ESR) spin label methods were used to study membrane fluidity of Chinese hamster ovary (CHO) cells grown on microcarriers and in suspension using 5-doxylstearic acid spin label as a probe. CHO cells grown on microcarriers had a more rigid cell membrane compared to CHO cells grown in suspension culture. CHO cells removed from the surface of the microcarriers by either trypsinization, EDTA treatment or osmotic shock had a membrane fluidity similar to that of CHO cells grown in suspension culture. Conversely, when the cells grown in suspension culture were attached and flattened on the surface of the microcarriers the fluidity decreased. Moreover, membrane fluidity of CHO cells grown on microcarriers changed as a function of the population density, whereas that of the cells in suspension did not. This implies that cell adhesion and/or cell-cell interactions influence the fluidity of the cell surface membrane.  相似文献   

14.
Although cellular mechanical properties are known to alter during stem cell differentiation, understanding of the functional relevance of such alterations is incomplete. Here, we show that during the course of differentiation of human myeloid precursor cells into three different lineages, the cells alter their viscoelastic properties, measured using an optical stretcher, to suit their ultimate fate and function. Myeloid cells circulating in blood have to be advected through constrictions in blood vessels, engendering the need for compliance at short time-scales (<seconds). Intriguingly, only the two circulating myeloid cell types have increased short time scale compliance and flow better through microfluidic constrictions. Moreover, all three differentiated cell types reduce their steady-state viscosity by more than 50% and show over 140% relative increase in their ability to migrate through tissue-like pores at long time-scales (>minutes), compared to undifferentiated cells. These findings suggest that reduction in steady-state viscosity is a physiological adaptation for enhanced migration through tissues. Our results indicate that the material properties of cells define their function, can be used as a cell differentiation marker and could serve as target for novel therapies.  相似文献   

15.
Collective cell movement is critical in pathological processes such as wound healing and cancer invasion. It entails complex interactions between adjacent cells and between cells-extracellular matrices. Most studies measure the migration patterns and force propagation by placing cells on flat, patterned substrates. The cooperative behavior resulting from cell-cell interactions is not well understood. We have developed a multi-channel microfluidic device that has junctional protein E-cadherin coated onto the sidewalls of the channels that enables the cells’ lateral interactions with their neighbors to be studied. Our study reveals that epithelial cells rely on lateral E-cadherin-based adhesions to maintain the cohesion of the group. Cells move faster in narrower channels, but the average velocity along the channels is reduced in E-cadherin coated channels versus non-adhesive channels. We have directly measured the forces in the cross-linking protein, alpha-actinin, using FRET sensors during cell migration, and found that higher tension exists at the cell edges adjacent to the walls coated with E-cadherin, the implication being E-cadherin transmits the shear forces but does not provide a driving force for this migration.  相似文献   

16.
Rapid mechanical deformation of cells has emerged as a promising, vector-free method for intracellular delivery of macromolecules and nanomaterials. This technology has shown potential in addressing previously challenging applications; including, delivery to primary immune cells, cell reprogramming, carbon nanotube, and quantum dot delivery. This vector-free microfluidic platform relies on mechanical disruption of the cell membrane to facilitate cytosolic delivery of the target material. Herein, we describe the detailed method of use for these microfluidic devices including, device assembly, cell preparation, and system operation. This delivery approach requires a brief optimization of device type and operating conditions for previously unreported applications. The provided instructions are generalizable to most cell types and delivery materials as this system does not require specialized buffers or chemical modification/conjugation steps. This work also provides recommendations on how to improve device performance and trouble-shoot potential issues related to clogging, low delivery efficiencies, and cell viability.  相似文献   

17.
The natural separation maintained by microfluidic flows is employed as the basis of a particle/cell sorting device. This method of separating particulate suspensions exploits the inherent laminar nature of microscale fluid dynamics and incorporates applied fields and image cytometry to enable sorting based upon any visually identifiable difference between colloid-sized cells or particles. This technique may be used to easily isolate, separate, sort, or enrich virtually any suspension of microscale biological or colloidal particles within a microfluidic system. The entire footprint of the device described here is less than 0.01 mm(2), allowing it to be readily incorporated within highly integrated micro total analysis systems (microTAS).  相似文献   

18.

Background

Microfluidics is an enabling technology with a number of advantages over traditional tissue culture methods when precise control of cellular microenvironment is required. However, there are a number of practical and technical limitations that impede wider implementation in routine biomedical research. Specialized equipment and protocols required for fabrication and setting up microfluidic experiments present hurdles for routine use by most biology laboratories.

Results

We have developed and validated a novel microfluidic device that can directly interface with conventional tissue culture methods to generate and maintain controlled soluble environments in a Petri dish. It incorporates separate sets of fluidic channels and vacuum networks on a single device that allows reversible application of microfluidic gradients onto wet cell culture surfaces. Stable, precise concentration gradients of soluble factors were generated using simple microfluidic channels that were attached to a perfusion system. We successfully demonstrated real-time optical live/dead cell imaging of neural stem cells exposed to a hydrogen peroxide gradient and chemotaxis of metastatic breast cancer cells in a growth factor gradient.

Conclusion

This paper describes the design and application of a versatile microfluidic device that can directly interface with conventional cell culture methods. This platform provides a simple yet versatile tool for incorporating the advantages of a microfluidic approach to biological assays without changing established tissue culture protocols.  相似文献   

19.
We consider cells bound to the floor of a microfluidic channel and present a model of their flow-induced detachment. We approximate hydrodynamic force and cell elastic response using static finite-element simulation of a single cell. Detachment is assumed to occur when hydrodynamic and adhesive forces are roughly equal. The result is extended to multiple cells at the device level using a sigmoidal curve fit. The model is applied to a microfluidic cancer-screening device that discriminates between normal epithelial cells and cells infected with human papillomavirus (HPV), on the basis of increased expression of the transmembrane protein alpha6 integrin in the latter. Here, the cells to be tested are bound to a microchannel floor coated with anti alpha6 integrin antibodies. In an appropriate flow rate range, normal cells are washed away while HPV-infected cells remain bound. The model allows interpolation between data points to choose the optimal flow rate and provides insight into interaction of cell mechanical properties and the flow-induced detachment mechanism. Notably, the results suggest a significant influence of cell elastic response on detachment.  相似文献   

20.
细胞机械性能与细胞的生理状态与功能存在密切联系。早期对于细胞机械性能的研究受制于技术条件,只能获得细胞群的弹性或剪切模量,使得少量异质细胞的机械表型被淹没。近年来,单细胞机械性能检测技术得到了蓬勃发展。原子力显微镜、微吸管技术、光镊与光学拉伸、磁扭转流变仪与磁镊等单细胞机械性能检测技术展现出非常高的检测精度,但检测通量相对较低。新型微流控高通量检测方法的出现使检测通量呈几何式增长,有望解决大样本快速检测的需求。本文首先综述原子力显微镜、微吸管、光镊与光学拉伸和磁扭转流变仪与磁镊等单细胞机械性能检测技术。在此基础上,重点介绍细胞过孔、剪切诱导细胞变形和拉伸诱导细胞变形3种新兴微流控高通量检测技术的工作原理及最新研究进展,探讨各类方法的优缺点。最后,本文展望单细胞机械性能检测技术的未来发展方向。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号