首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Modelling flow-diverting (FD) stents as porous media (PM) markedly improves the efficiency of computational fluid dynamics (CFD) simulations in the study of intracranial aneurysm treatment. Nonetheless, the parameters of PM models adopted for simulations up until now were rarely calibrated to match the represented FD structure. We therefore sought to evaluate the PM parameters for a representative variety of commercially available stents, so characterising the flow-diversion behaviours of different FD devices on the market.We generated fully-resolved geometries for treatments using PED, Silk+, FRED, and dual PED stents. We then correspondingly derived the calibrated PM parameters—permeability (k) and inertial resistance factor (C2)—for each stent design from CFD simulations, to ensure the calibrated PM model has identical flow resistance to the FD stent it represents. With each of the calibrated PM models respectively deployed in two aneurysms, we studied the flow-diversion effects of these stent configurations.This work for the first time reported several sets of parameters for PM models, which is vital to address the current knowledge gap and rectify the errors in PM model simulations, thereby setting right the modelling protocol for future studies using PM models. The flow resistance parameters were strongly affected by porosity and effective thickness of the commercial stents, and thus accounted for in the PM models. Flow simulations using the PM stent models revealed differences in aneurysmal mass flowrate (MFR) and energy loss (EL) between various stent designs.This study improves the practicability of FD simulation by using calibrated PM models, providing an individualised method with improved simulation efficiency and accuracy.  相似文献   

2.
Endovascular coiling aims to isolate the aneurysm from blood circulation by altering hemodynamics inside the aneurysm and triggering blood coagulation. Computational fluid dynamics (CFD) techniques have the potential to predict the post-operative hemodynamics and to investigate the complex interaction between blood flow and coils. The purpose of this work is to study the influence of blood viscosity on hemodynamics in coiled aneurysms. Three image-based aneurysm models were used. Each case was virtually coiled with a packing density of around 30%. CFD simulations were performed in coiled and untreated aneurysm geometries using a Newtonian and a Non-Newtonian fluid models. Newtonian fluid slightly overestimates the intra-aneurysmal velocity inside the aneurysm before and after coiling. There were numerical differences between fluid models on velocity magnitudes in coiled simulations. Moreover, the non-Newtonian fluid model produces high viscosity (>0.007>0.007 [Pa s]) at aneurysm fundus after coiling. Nonetheless, these local differences and high-viscous regions were not sufficient to alter the main flow patterns and velocity magnitudes before and after coiling. To evaluate the influence of coiling on intra-aneurysmal hemodynamics, the assumption of a Newtonian fluid can be used.  相似文献   

3.
Endovascular coiling is the most common treatment for cerebral aneurysms. During the treatment, a sequence of embolic coils with different stiffness, shapes, sizes, and lengths is deployed to fill the aneurysmal sac. Although coil packing density has been clinically correlated with treatment success, many studies have also reported success at low packing densities, as well as recurrence at high packing densities. Such reports indicate that other factors may influence treatment success. In this study, we used a novel finite element approach and computational fluid dynamics (CFD) to investigate the effects of packing density, coil shape, aneurysmal neck size, and parent vessel flow rate on aneurysmal hemodynamics. The study examines a testbed of 80 unique CFD simulations of post-treatment flows in idealized basilar tip aneurysm models. Simulated coil deployments were validated against in vitro and in vivo deployments. Among the investigated factors, packing density had the largest effect on intra-aneurysmal velocities. However, multifactor analysis of variance showed that coil shape can also have considerable effects, depending on packing density and neck size. Further, linear regression analysis showed an inverse relationship between mean void diameter in the aneurysm and mean intra-aneurysmal velocities, which underscores the importance of coil distribution and thus coil shape. Our study suggests that while packing density plays a key role in determining post-treatment hemodynamics, other factors such as coil shape, aneurysmal geometry, and parent vessel flow may also be very important.  相似文献   

4.
Endovascular intervention using traditional neurovascular stents and densely braided flow diverters (FDs) have become the preferred treatment strategies for traditionally challenging intracranial aneurysms. Modeling stent and FD deployment in patient-specific aneurysms and its flow modification results prior to the actual intervention can potentially predict the patient outcome and treatment optimization. We present a clinically focused, streamlined virtual stenting workflow that efficiently simulates stent and FD treatment in patient-specific aneurysms based on expanding a simplex mesh structure. The simplex mesh is generated using an innovative vessel-specific initialization technique, which uses the patient’s parent artery diameter to identify the initial position of the simplex mesh inside the artery. A novel adaptive expansion algorithm enables the acceleration of deployment process by adjusting the expansion forces based on the distance of the simplex mesh from the parent vessel. The virtual stenting workflow was tested by modeling the treatment of two patient-specific aneurysms using the Enterprise stent and the Pipeline Embolization Device (commercial FD). Both devices were deployed in the aneurysm models in a few seconds. Computational fluid dynamics analyses of pre- and post-treatment aneurysmal hemodynamics show flow reduction in the aneurysmal sac in treated aneurysms, with the FD diverting more flow than the Enterprise stent. The test results show that this workflow can rapidly simulate clinical deployment of stents and FDs, hence paving the way for its future clinical implementation.  相似文献   

5.
Background: Compacting a flow-diverting (FD) stent is an emerging technique to create a denser configuration of wires across the aneurysm ostium. However, quantitative analyses of post-stenting haemodynamics affected by the compaction level of different stent sizes remain inconclusive.Objective: To compare the aneurysmal haemodynamic alterations after virtual FD treatments with different device diameters at different compaction ratios.Methods: We virtually implanted three sizes of FD stent, with each size deployed at four compaction ratios, into two patient aneurysms previously treated with the Silk + FD—one successful case and the other unsuccessful. Wire configurations of the FD in the 24 treatment scenarios were examined, and aneurysmal haemodynamic alterations were resolved by computational fluid dynamics (CFD) simulations. We investigated the aneurysmal flow patterns, aneurysmal average velocity (AAV), mass flowrate (MF), and energy loss (EL) in each scenario.Results: Compactions of the stent in the successful case resulted in a greater metal coverage rate than that achieved in the unsuccessful one. A 25% increment in compaction ratio further decreased the AAV (12%), MF (11%), and EL (9%) in both cases (average values). The averaged maximum differences attributable to device size were 10% (AAV), 8% (MF), and 9% (EL).Conclusions: Both stent size and compaction level could markedly affect the FD treatment outcomes. It is therefore important to individualise the treatment plan by selecting the optimal stent size and deployment procedure. CFD simulation can be used to investigate the treatment outcomes, thereby assisting doctors in choosing a favourable treatment plan.  相似文献   

6.
Endovascular stents are being commonly used to treat cerebral wide-necked aneurysms recently. The effect of a stent placed in the parent artery is not only to protect the parent artery from occlusion, due to extension of coils and thrombosis, but also to act as flow diverter to vary the haemodynamics in the aneurysm. In this article, two idealised cerebral wide-necked aneurysms were created, one was sidewall aneurysm with curved parent vessel and the other was terminal aneurysm with the bifurcated parent vessel. The plexiglass models of the two aneurysms were 'treated' with commercial porous intravascular stents. The stented physical models were scanned by Micro-CT and the numerical models of the two idealised cerebral wide-necked aneurysms after stent placement were constructed from the scanned image files. The pulsatile flow of non-Newtonian fluid inside the models was simulated by using computational fluid dynamics package. From the simulated flow dynamics, various haemodynamic characteristics such as velocity contours, wall shear stress and oscillatory shear index (OSI) were computed. The velocity of the jet entering the sacs reduced after stent was deployed across the necks of both sidewall and terminal aneurysms; the wall shear stress on the distal neck of sidewall aneurysm reduced, the wall shear stress on the dome of the terminal aneurysm increased and the OSI on the dome of the terminal aneurysm reduced. Therefore, stent placement not only promotes thrombus formation in both aneurysm models but also reduces the regrowth risk of the sidewall aneurysm and the rupture risk of the terminal aneurysm.  相似文献   

7.
Endovascular stents are being commonly used to treat cerebral wide-necked aneurysms recently. The effect of a stent placed in the parent artery is not only to protect the parent artery from occlusion, due to extension of coils and thrombosis, but also to act as flow diverter to vary the haemodynamics in the aneurysm. In this article, two idealised cerebral wide-necked aneurysms were created, one was sidewall aneurysm with curved parent vessel and the other was terminal aneurysm with the bifurcated parent vessel. The plexiglass models of the two aneurysms were ‘treated’ with commercial porous intravascular stents. The stented physical models were scanned by Micro-CT and the numerical models of the two idealised cerebral wide-necked aneurysms after stent placement were constructed from the scanned image files. The pulsatile flow of non-Newtonian fluid inside the models was simulated by using computational fluid dynamics package. From the simulated flow dynamics, various haemodynamic characteristics such as velocity contours, wall shear stress and oscillatory shear index (OSI) were computed. The velocity of the jet entering the sacs reduced after stent was deployed across the necks of both sidewall and terminal aneurysms; the wall shear stress on the distal neck of sidewall aneurysm reduced, the wall shear stress on the dome of the terminal aneurysm increased and the OSI on the dome of the terminal aneurysm reduced. Therefore, stent placement not only promotes thrombus formation in both aneurysm models but also reduces the regrowth risk of the sidewall aneurysm and the rupture risk of the terminal aneurysm.  相似文献   

8.
《Journal of biomechanics》2014,47(14):3524-3530
To investigate the hemodynamic performance of overlapping bare-metal stents intervention treatment to thoracic aortic aneurysms (TAA), three simplified TAA models, representing, no stent, with a single stent and 2 overlapped stents deployed in the aneurismal sac, were studied and compared in terms of flow velocity, wall shear stress (WSS) and pressure distributions by means of computational fluid dynamics. The results showed that overlapping stents intervention induced a flow field of slow velocity near the aneurismal wall. Single stent deployment in the sac reduced the jet-like flow formed prior to the proximal neck of the aneurysm, which impinged on the internal wall of the aneurysm. This jet-like flow vanished completely in the overlapping double stents case. Overlapping stents intervention led to an evident decrease in WSS; meanwhile, the pressure acting on the wall of the aneurysm was reduced slightly and presented more uniform distribution. The results therefore indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a purpose similar to that of the multilayer aneurysm repair system (MARS) manufactured by Cardiatis SA (Isnes, Belgium).  相似文献   

9.
There is still a considerable lack of quantitative information concerning the effects of stent structures on blood flow in an aneurismal cavity. In this paper, five virtual stents with different structures and wire cross-sections were designed for incorporation into the same patient-specific aneurysm model. Computational fluid dynamics simulations were performed so as to study how these five types of stents modified hemodynamic parameters. Numerical results demonstrated that the mean flow rate in the aneurismal cavity decreased the most in the model that used a stent with a rectangular wire cross-section, and that the wall shear stresses at the dome and neck of the aneurysm decreased more in models that used a stent with a circular wire cross-section or a spiral stent with a rectangular wire cross-section compared to other models. In addition, the wall pressure on the aneurysm increased slightly after implantation of the stent in all five models. This result differs from that previously published, and may help guide the design and assist clinicians in selecting an appropriate stent for treating cerebral aneurysms.  相似文献   

10.
Cerebral aneurysms constitute a major medical challenge as treatment options are limited and often associated with high risks. Statistically, up to 3% of patients with a brain aneurysm may suffer from bleeding for each year of life. Eight percent of all strokes are caused by ruptured aneurysms. In order to prevent this rupture, endovascular stenting using so called flow diverters is increasingly being regarded as an alternative to the established coil occlusion method in minimally invasive treatment. Covering the neck of an aneurysm with a flow diverter has the potential to alter the hemodynamics in such a way as to induce thrombosis within the aneurysm sac, stopping its further growth, preventing its rupture and possibly leading to complete resorption. In the present study the influence of different flow diverters is quantified considering idealized patient configurations, with a spherical sidewall aneurysm placed on either a straight or a curved parent vessel. All important hemodynamic parameters (exchange flow rate, velocity, and wall shear stress) are determined in a quantitative and accurate manner using computational fluid dynamics when varying the key geometrical properties of the aneurysm. All simulations are carried out using an incompressible, Newtonian fluid with steady conditions. As a whole, 72 different cases have been considered in this systematic study. In this manner, it becomes possible to compare the efficiency of different stents and flow diverters as a function of wire density and thickness. The results show that the intra-aneurysmal flow velocity, wall shear stress, mean velocity, and vortex topology can be considerably modified thanks to insertion of a suitable implant. Intra-aneurysmal residence time is found to increase rapidly with decreasing stent porosity. Of the three different implants considered in this study, the one with the highest wire density shows the highest increase of intra-aneurysmal residence time for both the straight and the curved parent vessels. The best hemodynamic modifications are always obtained for a small aneurysm diameter.  相似文献   

11.
The strength and direction of blood flow into and within a cerebral aneurysm are important issues in developing effective interventional strategies to stabilize the aneurysm. We tested the hypothesis that there are significant major hemodynamic features that are common to many aneurysm flows of the type studied here. This was investigated by performing computational fluid dynamic simulations of flow near 7 cerebral aneurysms using geometrical data obtained from clinical CT scans. Our numerical simulations of flow across the ostium plane of an aneurysm show that in many cases there is relatively stable flow structure that is maintained over the phase of the pulsatile flow cycle. The two main features of this flow are (1) quasi-permanent regions of flow influx and efflux across the ostium plane exist, separated by a “virtual boundary”, and (2) a helical vortex flow pattern within the aneurismal sac with swirl in two orthogonal cross-sectional planes. These numerical observations are consistent with in vitro experimental data from ultrasound color-Doppler velocimetry and other numerical and experimental studies. The observed flow patterns are found to occur in different types of aneurysms (bifurcation and sidewall), and can persist even after flow parameters are perturbed beyond the normal range of physiological flow conditions. These results suggest that in many cases, major aspects of the behavior of aneurismal hemodynamics for important classes of aneurysms can be learned from an analysis of steady, non-pulsatile flow, which is simpler and faster to simulate than time-dependent, pulsatile flow. An understanding of this fluid dynamical behavior may also prove useful in the design of stents, coils, and various other endovascular flow diverting devices.  相似文献   

12.
This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and interventional planning.  相似文献   

13.
Finite-element modeling of the hemodynamics of stented aneurysms   总被引:6,自引:0,他引:6  
BACKGROUND: Computational fluid dynamics (CFD) simulations are used to analyze the wall shear stress distribution and flow streamlines near the throat of a stented basilar side-wall aneurysm. Previous studies of stented aneurysm flows used low mesh resolution, did not include mesh convergence analyses, and depended upon conformal meshing techniques that apply only to very artificial stent geometries. METHOD OF APPROACH: We utilize general-purpose computer assisted design and unstructured mesh generation tools that apply in principle to stents and vasculature of arbitrary complexity. A mesh convergence analysis for stented steady flow is performed, varying node spacing near the stent. Physiologically realistic pulsatile simulations are then performed using the converged mesh. RESULTS: Artifact-free resolution of the wall shear stress field on stent wires requires a node spacing of approximately 1/3 wire radius. Large-scale flow features tied to the velocity field are, however, captured at coarser resolution (nodes spaced by about one wire radius or more). CONCLUSIONS: Results are consistent with previous work, but our methods yield more detailed insights into the complex flow dynamics. However, routine applications of CFD to anatomically realistic cases still depend upon further development of dedicated algorithms, most crucially to handle geometry definition and mesh generation for complicated stent deployments.  相似文献   

14.
《Journal of biomechanics》2014,47(16):3882-3890
Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic quantities that have been shown to predict aneurysm rupture, as well as maximal WSS (MWSS), energy loss (EL) and pressure loss coefficient (PLc). Sixteen pulsatile CFD simulations were carried out on four typical saccular aneurysms using 4 different waveforms and an identical inflow rate as inlet boundary conditions. Our results demonstrated that under the same mean inflow rate, different waveforms produced almost identical WSS distributions and WSS magnitudes, similar OSI distributions but drastically different OSI magnitudes. The OSI magnitude is correlated with the pulsatility index of the waveform. Furthermore, there is a linear relationship between aneurysm-averaged OSI values calculated from one waveform and those calculated from another waveform. In addition, different waveforms produced similar MWSS, EL and PLc in each aneurysm. In conclusion, inlet waveform has minimal effects on WSS, OSI distribution, MWSS, EL and PLc and a strong effect on OSI magnitude, but aneurysm-averaged OSI from different waveforms has a strong linear correlation with each other across different aneurysms, indicating that for the same aneurysm cohort, different waveforms can consistently stratify (rank) OSI of aneurysms.  相似文献   

15.
Treatment of intracranial aneurysms with flow-diverting stents is a safe and minimally invasive technique. The goal is stable embolisation that facilitates stent endothelialisation, and elimination of the aneurysm. However, it is not fully understood why some aneurysms fail to develop a stable clot even with sufficient levels of flow reduction. Computational prediction of thrombus formation dynamics can help predict the post-operative response in such challenging cases. In this work, we propose a new model of thrombus formation and platelet dynamics inside intracranial aneurysms. Our novel contribution combines platelet activation and transport with fibrin generation, which is key to characterising stable and unstable thrombus. The model is based on two types of thrombus inside aneurysms: red thrombus (fibrin- and erythrocyte-rich) can be found in unstable clots, while white thrombus (fibrin- and platelet-rich) can be found in stable clots. The thrombus generation model is coupled to a CFD model and the flow-induced platelet index (FiPi) is defined as a quantitative measure of clot stability. Our model is validated against an in vitro phantom study of two flow-diverting stents with different sizing. We demonstrate that our model accurately predicts the lower thrombus stability in the oversized stent scenario. This opens possibilities for using computational simulations to improve endovascular treatment planning and reduce adverse events, such as delayed haemorrhage of flow-diverted aneurysms.  相似文献   

16.
Haemodynamic factors, in particular wall shear stresses (WSSs) may have significant impact on growth and rupture of cerebral aneurysms. Without a means to measure WSS reliably in vivo, computational fluid dynamic (CFD) simulations are frequently employed to visualise and quantify blood flow from patient-specific computational models. With increasing interest in integrating these CFD simulations into pretreatment planning, a better understanding of the validity of the calculations in respect to computation parameters such as volume element type, mesh size and mesh composition is needed. In this study, CFD results for the two most common aneurysm types (saccular and terminal) are compared for polyhedral- vs. tetrahedral-based meshes and discussed regarding future clinical applications. For this purpose, a set of models were constructed for each aneurysm with spatially varying surface and volume mesh configurations (mesh size range: 5119-258, 481 volume elements). WSS distribution on the model wall and point-based velocity measurements were compared for each configuration model. Our results indicate a benefit of polyhedral meshes in respect to convergence speed and more homogeneous WSS patterns. Computational variations of WSS values and blood velocities are between 0.84 and 6.3% from the most simple mesh (tetrahedral elements only) and the most advanced mesh design investigated (polyhedral mesh with boundary layer).  相似文献   

17.
BACKGROUND: Computational fluid dynamics (CFD) simulations using medical-image-based anatomical vascular geometry are now gaining clinical relevance. This study aimed at validating the CFD methodology for studying cerebral aneurysms by using particle image velocimetry (PIV) measurements, with a focus on the effects of small geometric variations in aneurysm models on the flow dynamics obtained with CFD. METHOD OF APPROACH: An experimental phantom was fabricated out of silicone elastomer to best mimic a spherical aneurysm model. PIV measurements were obtained from the phantom and compared with the CFD results from an ideal spherical aneurysm model (S1). These measurements were also compared with CFD results, based on the geometry reconstructed from three-dimensional images of the experimental phantom. We further performed CFD analysis on two geometric variations, S2 and S3, of the phantom to investigate the effects of small geometric variations on the aneurysmal flow field. Results. We found poor agreement between the CFD results from the ideal spherical aneurysm model and the PIV measurements from the phantom, including inconsistent secondary flow patterns. The CFD results based on the actual phantom geometry, however, matched well with the PIV measurements. CFD of models S2 and S3 produced qualitatively similar flow fields to that of the phantom but quantitatively significant changes in key hemodynamic parameters such as vorticity, positive circulation, and wall shear stress. CONCLUSION: CFD simulation results can closely match experimental measurements as long as both are performed on the same model geometry. Small geometric variations on the aneurysm model can significantly alter the flow-field and key hemodynamic parameters. Since medical images are subjected to geometric uncertainties, image-based patient-specific CFD results must be carefully scrutinized before providing clinical feedback.  相似文献   

18.
Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CFD simulations were then carried out using a well-validated, in-house solver, based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CFD simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement between PIV and CFD suggests that CFD can reliably predict the details of the intra-aneurysmal flow dynamics observed in anatomically realistic in vitro models. Nevertheless, given the various modeling assumptions, this does not prove that they are mimicking the actual in vivo hemodynamics, and so validations against in vivo data are encouraged whenever possible.  相似文献   

19.
In experiments turbulence has previously been shown to occur in intracranial aneurysms. The effects of turbulence induced oscillatory wall stresses could be of great importance in understanding aneurysm rupture. To investigate the effects of turbulence on blood flow in an intracranial aneurysm, we performed a high resolution computational fluid dynamics (CFD) simulation in a patient specific middle cerebral artery (MCA) aneurysm using a realistic, pulsatile inflow velocity. The flow showed transition to turbulence just after peak systole, before relaminarization occurred during diastole. The turbulent structures greatly affected both the frequency of change of wall shear stress (WSS) direction and WSS magnitude, which reached a maximum value of 41.5Pa. The recorded frequencies were predominantly in the range of 1-500Hz. The current study confirms, through properly resolved CFD simulations that turbulence can occur in intracranial aneurysms.  相似文献   

20.
《Journal of biomechanics》2014,47(15):3695-3703
Most computational fluid dynamic (CFD) simulations of aneurysm hemodynamics assume constant (Newtonian) viscosity, even though blood demonstrates shear-thinning (non-Newtonian) behavior. We sought to evaluate the effect of this simplifying assumption on hemodynamic forces within cerebral aneurysms, especially in regions of low wall shear stress, which are associated with rupture. CFD analysis was performed for both viscosity models using 3D rotational angiography volumes obtained for 26 sidewall aneurysms (12 with blebs, 12 ruptured), and parametric models incorporating blebs at different locations (inflow/outflow zone). Mean and lowest 5% values of time averaged wall shear stress (TAWSS) computed over the dome were compared using Wilcoxon rank-sum test. Newtonian modeling not only resulted in higher aneurysmal TAWSS, specifically in areas of low flow and blebs, but also showed no difference between aneurysms with or without blebs. In contrast, for non-Newtonian analysis, bleb-bearing aneurysms showed significantly lower 5% TAWSS compared to those without (p=0.005), despite no significant difference in mean dome TAWSS (p=0.32). Non-Newtonian modeling also accentuated the differences in dome TAWSS between ruptured and unruptured aneurysms (p<0.001). Parametric models further confirmed that realistic non-Newtonian viscosity resulted in lower bleb TAWSS and higher focal viscosity, especially when located in the outflow zone. The results show that adopting shear-thinning non-Newtonian blood viscosity in CFD simulations of intracranial aneurysms uncovered hemodynamic differences induced by bleb presence on aneurysmal surfaces, and significantly improved discriminant statistics used in risk stratification. These findings underline the possible implications of using a realistic model of blood viscosity in predictive computational hemodynamics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号