首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A model of a reactor-type biosensor based on the Rhodococcus erythropolis HL PM-1 was developed for amperometric detection of 2,4-dinitrophenol (2,4-DNP). The effects of the matrix material (agar and calcium alginate gels, ceramic support, and cellulose powder) on the biosensor signal concentration dependence, detection time, and biosensor stability were studied. In case of bacterial cells immobilized on cellulose powder, the lower limit of 2,4-DNP detection was 20 microM and the time of single analysis, the biosensor recovery included, was 30-50 min. In the continuous detection mode, the biosensor response was maintained at a stable level without biosensor inactivation for ten days. The biosensor can be used as an element of a complex analytical system for detecting nitroaromatic compounds in samples.  相似文献   

2.
A high density microelectrode array biosensor was developed for the detection of Escherichia coli O157:H7. The biosensor was fabricated from (100) silicon with a 2 microm layer of thermal oxide as an insulating layer, an active area of 9.6 mm2 and consists of an interdigitated gold electrode array. The sensor surface was functionalised for bacterial detection using heterobifunctional crosslinkers and immobilised polyclonal antibodies to create a biological sensing surface. Bacteria suspended in solution became attached to the immobilised antibodies when the biosensor was tested in liquid samples. The change in impedance caused by the bacteria was measured over a frequency range of 100 Hz-10 M Hz. The biosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The biosensor was able to discriminate between cellular concentrations of 10(4)-10(7)CFU/mL and has applications in detecting pathogens in food samples.  相似文献   

3.
An amperometric flow biosensor, using laccase from Rigidoporus lignosus as bioelement was developed. The laccase was kinetically characterized towards various phenolics both in solution and immobilized to a hydrophilic matrix by carbodiimide chemistry. A bioreactor connected to an amperometric flow cell by a FIA system was filled with the immobilized enzyme and the operational conditions of this biosensor were optimized as regards pH. Under the adopted experimental conditions, the immobilized enzyme oxidizes all the substrate molecules avoiding the need of cumbersome calibration procedures. The biosensor sensitivity, which was found to be 100 nA/microM for some of the tested substrates, resulted to be constant for more than 100 working days. This biosensor permits the detection of phenolics in aqueous solutions at concentrations in the nanomolar range and was successfully used to detect phenolics in wastewaters from olive oil mill without sample preparation.  相似文献   

4.
A model of a reactor-type biosensor based on the Rhodococcus erythropolis HL PM-1 was developed for amperometric detection of 2,4-dinitrophenol (2,4-DNP). The effects of the matrix material (agar and calcium alginate gels, ceramic support, and cellulose powder) on the biosensor signal concentration dependence, detection time, and biosensor stability were studied. In the case of bacterial cells immobilized on cellulose powder, the lower limit of 2,4-DNP detection was 20 M and the time of single analysis, the biosensor recovery included, was 30–50 min. In the continuous detection mode, the biosensor response was maintained at a stable level without biosensor inactivation for ten days. The biosensor can be used as an element of a complex analytical system for detecting nitroaromatic compounds in samples.  相似文献   

5.
Pan D  Chen J  Nie L  Tao W  Yao S 《Analytical biochemistry》2004,324(1):115-122
Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.  相似文献   

6.
Paper supports were used to develop a simple, inexpensive, fast and sensitive electrochemical immunosensor for the analysis of antibiotic residues in milk samples, where single-walled carbon nanotubes (SWNTs) and a simple dip-dry coating method were employed to prepare the highly sensitive biosensor. Well-dispersed SWNTs were impregnated with an antibody against neomycin to obtain a composite coating solution, followed by dipping the filtration paper in the solution to fabricate the sensitive biosensor which had high electrical conductivity. Based on the impedance change in the entire paper supported biosensor with increased concentrations of neomycin, the limit detection of the optimized method was 0.04 ng mL(-1) and a linear detection range from 0.2 to 125 ng mL(-1), well below the European Union regulations for neomycin in this matrix. This paper supported biosensor was applied to determine neomycin in milk samples after a simple sample treatment, with spiked recoveries which ranged from 93.25 to 110.47%. A variety of antibiotic residues in milk samples could be determined following similar sensor preparation.  相似文献   

7.
Strain Comamonas testosteroni TI, capable of degrading the nonionic surfactant (NIS) nonylphenolethoxylate (OP-10), was used for constructing a pilot cellular biosensor. The lower NIS detection limit for the biosensor was 0.25 mg/l. We studied the substrate specificity of the biosensor with respect to a wide range of organic compounds: surfactants, polyaromatic compounds (PAC), carbohydrates, alcohols, etc. It was shown that the biosensor based on Comamonas testosteroni TI did not respond to glucose, which was an advantage over the formerly described biosensor based on Pseudomonas rathonis T. The amplitude of the sensor response remained stable for 10 days.  相似文献   

8.
We have developed a stable and selective ATP biosensor for long-term in vitro tissue monitoring. The electrode was fabricated by entrapping glucose oxidase (GOx) and hexokinase (HEX) in a poly-phenol film on a Pt microelectrode. The biosensor was stable to a fixed concentration of glucose for over 20 min and had a limit of detection of 9.9 ± 3.2 nM, with a sensitivity of 45.8 ± 1.22 pA μM(-1). Most significantly of all, the response on the ATP biosensor did not alter in the presence of 1mM ascorbic acid, 5 μM dopamine, 5 μM serotonin, 5 μM ADP and 5 μM AMP. The ATP biosensor was also shown to have excellent stability over 7 days, and showed only a 23.92 ± 3.55% loss in sensitivity. The ATP biosensor was utilised for the in vitro detection of ATP from gastrointestinal tissue. The ATP biosensor response was stable for 5h during in vitro recordings from ileum tissue. ATP release was shown to be greater from the mucosal surface in the ileum compared to the colon.  相似文献   

9.
Aeromonas hydrophila P69.1 (A. hydrophila) was used to construct a semi-specific biosensor to estimate biochemical oxygen demand (BOD) in high fat and grease content wastewaters. A. hydrophila cells were grown in fat containing medium to induce necessary enzymes for transport and degradation of fatty substances. Universal biosensor based on non-specific Pseudomonas fluorescens P75 (P. fluorescens) was used to conduct comparison experiments. Biosensors were calibrated using OECD synthetic wastewater and steady-state method, subsequently several experiments with synthetic and industrial wastewaters were conducted. A linear range up to 45 mg l(-1) BOD(7) was gained using A. hydrophila biosensor, in comparison to 40 mg l(-1) BOD(7) obtained using P. fluorescens biosensors. The lower limit of detection was 5 mg l(-1) BOD(7). Service life of A. hydrophila and P. fluorescens biosensors were 110 and 115 days, respectively. The response time of the biosensors depended on the BOD(7) of measuring solution and was up to 20 min when analyzing different wastewaters. Both biosensors underestimated BOD in meat industry wastewater from 43% up to 71%, but more accurate results could be obtained with A. hydrophila biosensor. Semi-specific A. hydrophila biosensor was able to measure proportion of fat found in wastewater sample, while other refractory compounds remained undetectable to both biosensors.  相似文献   

10.
An urea biosensor based on urease-BSA (bovine serum albumin) membrane immobilised on the surface of an ion-sensitive field effect transistor (ISFET) has been studied in a mix buffer solution composed of potassium phosphate, Tris, citric acid and sodium tetraborate. In this mix buffer, the biosensor showed a dynamic larger than the one observed in a phosphate or Tris buffer. Investigation of the individual effect of each component of the buffer solution on the biosensor response has shown that tetraborate anion acts as a strong competitive inhibitor for the hydrolysis reaction of urea catalysed by urease. The biosensor response was investigated in a phosphate buffer with different concentrations of tetraborate anion. The results showed that the apparent constant of Michaelis-Menten, K(m(app)), increases from 4.3 to 79.3 mM, for experiments realised without and with 0.5 mM sodium tetraborate, respectively. The mean value, determined graphically, for the inhibition constant, K(i), was 29 microM. The graphical representation of biosensor calibration curves in semilogarithmic co-ordinates showed that the linear range of the biosensor can be extended up to three orders of magnitude, allowing an urea detection in a concentration range 0-100 mM.  相似文献   

11.
Porous silicon-based biosensor for pathogen detection   总被引:7,自引:0,他引:7  
A porous silicon-based biosensor for rapid detection of bacteria was fabricated. Silicon (0.01 ohmcm, p-type) was anodized electrochemically in an electrochemical Teflon cell containing ethanoic hydrofluoric acid solution to produce sponge-like porous layer of silicon. Anodizing conditions of 5 mA/cm2 for 85 min proved best for biosensor fabrication. A single-tube chemiluminescence-based assay, previously developed, was adapted to the biosensor for detection of Escherichia coli. Porous silicon chips were functionalized with a dioxetane-Polymyxin B (cell wall permeabilizer) mixture by diffusion and adsorption on to the porous surface. The reaction of beta-galactosidase enzyme from E. coli with the dioxetane substrate generated light at 530 nm. Light emission for the porous silicon biosensor chip with E. coli was significantly greater than that of the control and planar silicon chip with E. coli (P<0.01). Sensitivity of the porous silicon biosensor was determined to be 101-102 colony forming units (CFU) of E. coli. The porous silicon-based biosensor was fabricated and functionalized to successfully detect E. coli and has potential applications in food and environmental testing.  相似文献   

12.
A fluorescent glucose biosensor was constructed by immobilizing glucose oxidase on a bamboo inner shell membrane with glutaraldehyde as a cross-linker. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution with a concomitant increase in the fluorescence intensity of an oxygen transducer, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(Pi) ditetrakis(4-chlorophenyl)borate. The enzyme immobilization, effect of pH, temperature and ionic strength have been studied in detail. The biosensor exhibited repeatable response to a 2.0 mM glucose solution with a relative standard deviation of 3.0% (n = 10). It showed good storage stability and maintained 95% of its initial response after it had been kept at 4 degrees C for 8 months. The biosensor has a linear response range of 0.0-0.6 mM glucose with a detection limit of 58 microM (S/N = 3). Common potential interferants in samples do not pose any significant interference on the response of the glucose biosensor. It was successfully applied to the determination of glucose content in some commercial wines and medical glucose injections.  相似文献   

13.
Nanosized flower-like ZnO was synthesized by a simple hydrothermal method which is a convenient, environment friendly, inexpensive and efficient process. Raman spectroscopy, X-ray diffraction (XRD) and scanning electron microscope (SEM) were used to confirm the material structure and the crystallite microstructure. Then ZnO was dispersed in the chitosan solution to form a ZnO/chitosan composite matrix for the fabrication of H2O2 biosensor. This composite combined the advantages of inorganic species (ZnO) and organic polymer (chitosan). The parameters affecting the fabrication and experimental conditions of biosensors were optimized. Using hydroquinone as the mediator, the biosensor showed a fast response of less than 5s with the linear range of 1.0x10(-5) to 1.8x10(-3) M H2O2 with a correlation coefficient of 0.995 (n=20). The detection limit of the sensor was found to be 2.0 microM, based on a signal-to-noise ratio of 3. The biosensor exhibited satisfactory reproducibility and stability and retained about 78% of its original response after 40 days storage in a phosphate buffer at 4 degrees C.  相似文献   

14.
Shan D  He Y  Wang S  Xue H  Zheng H 《Analytical biochemistry》2006,356(2):215-221
A novel glucose biosensor was constructed by electrochemical entrapment of glucose oxidase (GOD) into porous poly(acrylonitrile-co-acrylic acid), which was synthesized via radical polymerization of acrylonitrile and acrylic acid. The obtained biosensor showed a better stability and higher sensitivity than the biosensor prepared by simple physical adsorption. Effects of some experimental variables such as immobilization time, enzyme concentration, pH, applied potential, and temperature on the amperometric response of the sensor were investigated. The biosensor exhibited a rapid response to glucose (< 30s) with a linear range of 5 x 10(-6) to 3 x 10(-3)M and a sensitivity of 6.82 mAM(-1)cm(-2). The apparent Michaelis-Menten constant (K(M)(app)) was 7.3mM.  相似文献   

15.
An absorption-based surface plasmon resonance (SPR(Abs)) biosensor probe has been developed for simple and reproducible measurements of hydrogen peroxide using a modified Trinder's reagent (a chromogenic reagent). The reagent enabled the determination of the hydrogen peroxide concentration by the development of deep color dyes (lambda(max)=630nm) through the oxidative coupling reaction with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethylaniline sodium salt monohydrate (MAOS; C(13)H(20)NNaO(4)S.H(2)O) and 4-aminoantipyrine (4-AA) in the presence of hydrogen peroxide and horseradish peroxidase (HRP). In the present study, urea as an adduct of hydrogen peroxide for color development could be omitted from the measurement solution. The measurement solution containing 5mM hydrogen peroxide was deeply colored at a high absorbance value calculated as 46.7cm(-1) and was directly applied to the SPR(Abs) biosensing without dilution. The measurement was simply performed by dropping the measurement solution onto the surface of the SPR sensor probe, and the SPR(Abs) biosensor response to hydrogen peroxide was obtained as a reflectivity change in the SPR spectrum. After investigation of the pH profiles in the SPR(Abs) biosensor probe, a linear calibration curve was obtained between 1.0 and 50mM hydrogen peroxide (r=0.991, six points, average of relative standard deviation; 0.152%, n=3) with a detection limit of 0.5mM. To examine the applicability of this SPR(Abs) biosensor probe, 20mM glucose detection using glucose oxidase was also confirmed without influence of the refractive index in the measurement solution. Thus, the SPR(Abs) biosensor probe employing the modified Trinder's reagent demonstrated applicability to other analyte biosensing tools.  相似文献   

16.
A biosensor based on flow injection of the recognition element has been developed. As a model a pH-transducer was used, and urease was chosen as the recognition element. The pH-transducer was immersed in an internal flow-through chamber which was in contact with the sample solution via a semi-permeable membrane. The recognition element, urease, was injected into the buffer solution passing through the biosensor. The enzyme catalysed the hydrolysis of urea and the concomitant increase in pH was recorded. The biosensor response time was about three minutes at a constant flow rate of 0·05 ml/min. The linear range of the calibration curve of the biosensor was 0–5 mM. The observed detection limit was approximately 0.1 mM. The sample throughput was 6–12 per hour. The pH-response of the biosensor, for a sample solution containing urea (3·26 mM), showed a reproducibility (r.s.d) of 28% (n = 5) and a repeatability (r.s.d.) of 8% (n = 5). Operation at elevated temperatures (up to 50°C) was demonstrated. The presence of glucose (28 mM), acetone (6·7 mM), citric acid (0·2 mM) or sodium acetate (0·6 mM) in the sample solution did not interfere with the sensor response. A lowering of the biosensor response which was observed in the presence of copper ions (due to urease inhibition) could be completely eliminated by adding EDTA to the urease solution. Thus, this work demonstrates a new type of biosensors, based on SIRE-technology (Sensors with Injectable Recognition Elements), which show high accuracy and stability, quick response and high sample throughput. These features suggest the suitability of the system for automation. Such sensors should readily be combined with other enzymes or enzyme systems. The enzyme (urease) cost per analysis (injection) for the biosensor was estimated to be approximately US$0·02. This could be substantially reduced by further optimisation and miniaturisation.  相似文献   

17.
Ultrasensitive molecular beacon (MB) DNA biosensors, with micrometer to submicrometer sizes, have been developed for DNA/RNA analysis. The fluorescence-based biosensors have been applied in DNA/ RNA detection without the need for a dye-labeled target molecule or an intercalation reagent in the testing solution. Molecular beacons are hairpin-shaped oligonucleotides that report the presence of specific nucleic acids. We have designed a surface-immobilizable biotinylated ssDNA molecular beacon for DNA hybridization at a liquid-solid interface. The MBs have been immobilized onto ultrasmall optical fiber probes through avidin-biotin binding. The MB DNA biosensor has been used directly to detect, in real time, its target DNA molecules without the need for a competitive assay. The biosensor is stable and reproducible. The MB DNA biosensor has selectivity with single base-pair mismatch identification capability. The concentration detection limits and mass detection limits are 0.3 nM and 15 amol for a 105-microm biosensor, and 10 nM and 0.27 amol for a submicrometer biosensor, respectively. We have also prepared molecular beacon DNA biosensor arrays for simultaneous analysis of multiple DNA sequences in the same solution. The newly developed DNA biosensors have been used for the precise quantification of a specific rat gamma-actin mRNA sequence amplified by the polymerase chain reaction.  相似文献   

18.
In this study, a novel acetylcholinesterase-based biosensor was fabricated. Acetylcholinesterase (AChE) was immobilized onto a glassy carbon electrode (GCE) with the aid of Cu–Mg–Al calcined layered double hydroxide (CLDH). CLDH can provide a bigger effective surface area for AChE loading, which could improve the precision and stability of AChE biosensor. However, the poor electroconductibility of CLDHs could lead to the low sensitivity of AChE biosensor. In order to effectively compensate the disadvantages of CLDHs, graphene–gold nanocomposites were used for improving the electron transfer rate. Thus, the graphene–gold nanocomposite (GN-AuNPs) was firstly modified onto the GCE, and then the prepared CLDH-AChE composite was immobilized onto the modified GCE to construct a sensitive AChE biosensor for pesticides detection. Relevant parameters were studied in detail and optimized, including the pH of the acetylthiocholine chloride (ATCl) solution, the amount of AChE immobilized on the biosensor and the inhibition time governing the analytical performance of the biosensor. The biosensor detected chlorpyrifos at concentrations ranging from 0.05 to 150 μg/L. The detection limit for chlorpyrifos was 0.05 μg/L.  相似文献   

19.
Strain Comamonas testosteroni TI, capable of degrading the nonionic surfactant (NIS) nonylphenolethoxylate (OP-10), was used for constructing a pilot cellular biosensor. The lower NIS detection limit for the biosensor was 0.25 mg/l. We studied the substrate specificity of the biosensor with respect to a wide range of organic compounds: surfactants, polyaromatic compounds (PAC), carbohydrates, alcohols, etc. It was shown that the biosensor based on Comamonas testosteroni TI did not respond to glucose, which was an advantage over the formerly described biosensor based on Pseudomonas rathonis T. The amplitude of the sensor response remained stable for 10 days.  相似文献   

20.
An uric acid biosensor fabricated from a uricase-immobilized eggshell membrane and an oxygen electrode was presented. The detection schemes involve the enzymatic reactions of the uricase leading to the depletion of dissolved oxygen level upon exposure to uric acid solution. The decrease in oxygen level was monitored and related to the uric acid concentration. The scanning electron micrographs show the microstructure of the eggshell membrane within which the uricase is successfully immobilized. The effects of enzyme loading, pH, temperature, and phosphate buffer concentration on the response of the biosensor were investigated in detail. The uric acid biosensor has a linear response range of 4.0-640 microM with a detection limit of 2.0 microM (S/N=3). The response time was less than 100 s. The biosensor exhibited good repeatable response to a 0.10mM uric acid solution with a relative standard deviation of 3.1% (n=7). The reproducibility of fabrication of the biosensors using four different membranes was good with a R.S.D. of 3.2%. The biosensor showed extremely good stability with a shelf-life of at least 3 months. Some common potential interferents in samples such as glucose, urea, ascorbic acid, lactic acid, glycine, DL-alpha-alanine, DL-cysteine, KCl, NaCl, CaCl2, MgSO4, and NH4Cl showed no interferences on the response of the uric acid biosensor. The biosensor was successfully applied to determine the uric acid level in some human serum and urine samples, and the results agreed well with those obtained by a commercial colorimetric assay kit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号