共查询到20条相似文献,搜索用时 31 毫秒
1.
M. J. Rose E. J. Woolf B. K. Matuszewski 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,738(2):8
A method is described for the determination of celecoxib in human plasma. Samples were extracted using 3M Empore membrane extraction cartridges and separated under normal-phase HPLC conditions using a Nucleosil-NO2 (150×4.6 mm, 5 μm) column. Detection was accomplished using UV absorbance at 260 nm. The HPLC method included a column switching procedure, in which late eluting compounds were diverted to waste, to reduce run-time to 12 min. The assay was linear in the concentration range of 25–2000 ng/ml when 1-ml aliquots of plasma were extracted. Recoveries of celecoxib were greater than 91% over the calibration curve range. Intraday precision and accuracy for this assay were 5.7% C.V. or better and within 2.3% of nominal, respectively. The assay was used to analyze samples collected during human clinical studies. 相似文献
2.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,676(1):147-152
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifampin in human plasma. Rifampin and sulindac (internal standard) are extracted from human plasma using a C2 Bond Elut extraction column. A 100-μl volume of 0.1 M HCl is added to the plasma before extraction to increase the retenction of the compounds on the extraction column. Methanol (1 ml) is used to elute the compounds and 0.5 ml of 3 mg/ml ascorbic acid in water is added to the final eluate to reduce the oxidation of rifampin. Separation is achieved by reversed-phase chromatography on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate-acetonitrile (55:45, v/v). Detection is by ultraviolet absorbance at 340 nm. The retention times of rifampin and internal standard are approximately 4.4 and 7.8 min, respectively. The assay is linear in concentration ranges of 50 to 35 000 ng/ml. The quantitation limit is 50 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility. 相似文献
3.
4.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,676(1):125-130
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility. 相似文献
5.
Mei-Yi Zeng Zhi-Liang Lu Song-Cheng Yang Min Zhang Jie Liao Shu-Ling Liu Xi-He Teng 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,681(2):299
A reversed-phase high-performance liquid chromatographic method for the determination of benflumetol in human plasma is described. Benflumetol in plasma samples was extracted with a glacial acetic acid-ethyl acetate (1:100, v/v) mixture at pH 4.0. Chromatography was performed on a Spherisorb C18 column using a methanol-water-glacial acetic acid-diethyl amine (93:6:1:0.03, v/v) mixture as the mobile phase and UV-VIS detection at 335 nm. The identity and purity of the benflumetol peak were carefully examined, and the internal standard method was applied for its quantitation. The absolute recovery of benflumetol in spiked plasma samples was 92.91% over the concentration range 5–4000 ng/ml. The recovery of internal standard “8212” at a concentration of 300 ng/ml in spiked plasma was 84.85%. The detection limit of benflumetol was 11.8 ng/ml. Plasma concentration-time profiles in healthy volunteer adults were measured after a single-dose oral administration of 500 mg of benflumetol. The assay procedures were within the quality control limits. 相似文献
6.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,665(2):404-409
A simple HPLC method has been developed for the determination of ticlopidine in human plasma. Plasma samples were buffered at pH 9 and extracted with n-heptane-isoamyl alcohol (98.5: 1.5, v/v). Imipramine was used as internal standard. Chromatography was performed isocratically with acetonitrile-methanol-0.05 M KH2PO4 (20:25:55, v/v) at pH 3.0 containing 3% triethylamine at a flow-rate of 1 ml/min. A reversed-phase column, Supelcosil LC-8-DB, 15 cm × 4.6 mm I.D., 5 μm particle size, was used. The effluent was monitored by UV absorbance detection at 235 nm. The method showed good accuracy, precision and linearity in the concentration range 5–1200 ng/ml. The limit of quantitation was 5 ng/ml, with a precision (C.V.) of 8.91%, which is the same as that achieved by other authors with a previously published GC-MS method. The procedure described in this paper is simple and allows the routine assessment of ticlopidine plasma concentration in pharmacokinetic studies following therapeutic doses in human subjects. 相似文献
7.
Karadas F Surai PF Sparks NH Grammenidis E 《Comparative biochemistry and physiology. Part A, Molecular & integrative physiology》2005,140(4):430-435
The effects of supplementation of the maternal diet of quail with three natural sources of carotenoids (alfalfa nutrient concentrate (PX agrotrade mark), tomato powder and marigold extract) on the accumulation of retinol and retinyl esters in egg yolk and in the liver of the new hatchling and maternal were investigated. The present study showed that the vitamin A in quail egg yolk was present in 4 different forms, namely retinol (R 52-62%), retinyl linoleate (RL 9-11%), retinyl stearate (RS 4%), retinyl oleate (RO 11-15%) and retinyl palmitate (RP 13-22%). The retinyl ester profile of the liver of newly hatched quail (R 2-4%, RL 8-12%, RS 19-21%, RO 12-15%, RP 50-55%) differs from that of egg yolk but was similar to that of the liver of adult quail (R 1%, RL 5-6%, RS 21-28%, RO 9-12%, RP 54-63%). It has been shown that RO and RP concentrations in egg yolk and the liver of day old quail chick significantly increased as a result of carotenoid supplementation of the maternal diet. 相似文献
8.
J.G Supko J.R Soglia R.V Nair 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,714(2):416
The hydrocyanated derivative of the antitumor antibiotic quinocarmycin, DX-52-1 (I), exhibits impressive activity against human melanoma xenograft models in vivo. Phase I clinical trials to evaluate this compound as an antineoplastic agent have been initiated by the US National Cancer Institute. We have developed an HPLC assay for the determination of I in human plasma involving automated column switching and UV detection at 210 nm. The preparation of samples for chromatographic analysis entails the preliminary removal of plasma proteins by precipitation with acetonitrile, acidifying the clear supernatant to pH 4.5, then extracting twice with tert.-butyl methyl ether to recover the drug. A heart-cutting procedure employing two HPLC columns with contrasting retention characteristics under isocratic reversed-phase conditions was used to achieve the selectivity required for low wavelength UV detection of the analyte. The sample extract was initially loaded onto a column packed with a cyanopropyl stationary phase. During the predetermined time interval that I eluted from this column, a fully automated six-position switching valve was used to direct the effluent onto an octadecylsilane analytical column. The assay has been thoroughly validated with regard to linearity, inter- and intra-day accuracy and precision, recovery, selectivity and specificity. Using a sample volume of 1.0 ml, the lowest concentration of I quantified with acceptable day-to-day reproducibility was found to be 2.56 ng/ml (R.S.D. 18.9%, n=21, 4 months). This proved to be sufficiently sensitive for pharmacokinetic drug level monitoring in cancer patients treated with a 6-h continuous intravenous infusion of I, even at the starting dose of 3 mg/m2. The successful performance and reliability of the assay has been demonstrated through extensive application to the routine analysis of plasma specimens acquired during a phase I clinical trial of the drug. 相似文献
9.
Determination of scutellarin in rat plasma by high-performance liquid chromatography with ultraviolet detection 总被引:9,自引:0,他引:9
Zhong D Yang B Chen X Li K Xu J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,796(2):439-444
A validated high-performance liquid chromatography method is described for the determination of scutellarin in rat plasma using a liquid-liquid extraction and ultraviolet (UV) absorbance detection. The separation used a Diamonsil ODS column (250 mm x 4.6mm i.d., 5 microm particle size) with an isocratic mobile phase consisting of methanol-acetonitrile-50mM dihydrogen ammonium phosphate buffer (22:15:63 (v/v/v), adjusted to pH 2.5 with 1M phosphoric acid). The ultraviolet detector operated at 335 nm. Plasma samples were extracted with ethyl acetate after acidification. The extraction recovery of scutellarin ranged from 68.1 to 80.5%. High selectivity and a low quantitation limit (0.050 microg/ml) were achieved. The linear range was 0.050-12.5 microg/ml, correlation coefficient r=0.9981. The method has a good reproducibility, R.S.D. values were below 7.9% for within-day and between-day precision. The method is simple, rapid, and applicable to preliminary pharmacokinetic studies of scutellarin in rats. 相似文献
10.
Laszlo Virag Berend Mets Subhash Jamdar 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,681(2):263
An isocratic high-performance liquid chromatographic method with ultraviolet detection at 235 nm is described for the determination of cocaine and its metabolites benzoylecgonine, norcocaine and ecgonine methyl ester in rat plasma, collected during toxicity studies. Following simultaneous solid-phase extraction of all analytes and the internal standard tropacocaine, cocaine, benzoylecgonine and norcocaine were separated on a C18 column. Ecgonine methyl ester and cocaine were separated on coupled cyanopropyl and silica columns, following derivatization of ecgonine methyl ester to p-fluorococaine. The extraction efficiencies of these compounds from plasma ranged from 78 to 87%, while the limits of detection ranged from 35 to 90 ng/ml. The assay was linear from 300 to 5000 ng/ml, and the within-day precision 2 to 8% over this concentration range. 相似文献
11.
S Cisternino J Schlatter J.L Saulnier 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,714(2):1018
A simple, rapid and reproducible high-performance liquid chromatographic assay for cisapride and norcisapride in human plasma is described. Samples of plasma (150 μl) were extracted using a C18 solid-phase cartridge. Regenerated tubes were eluted with 1.0 ml of methanol, dried, redissolved in 150 μl of methanol and injected. Chromatography was performed at room temperature by pumping acetonitrile–methanol–0.015 M phosphate buffer pH 2.2–2.3 (680:194:126, v/v/v) at 0.8 ml/min through a C18 reversed-phase column. Cisapride, norcisapride and internal standard were detected by absorbance at 276 nm and were eluted at 4.3, 5.3 and 8.1 min, respectively. Calibration plots in plasma were linear (r>0.998) from 10 to 150 ng/ml. Intraday precisions for cisapride and norcisapride were 3.3% and 5.4%, respectively. Interday precisions for cisapride and norcisapride were 9.6% and 9.0%, respectively. Drugs used which might be coadministered were tested for interference. 相似文献
12.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,728(1):125-131
Direct injection high-performance liquid chromatographic (HPLC) methods with column switching and UV detection were developed for the rapid and accurate determination of S-1090 in human plasma and urine. An internal-surface reversed-phase pre-column and a C18 analytical column were used for the plasma assay. Two pre-columns packed with cyano and phenyl materials and a C18 analytical column were used for the urine assay. The calibration curves for plasma and urine assays were linear in the ranges 0.09–9 μg/ml and 0.5–100 μg/ml of S-1090, respectively. The relative standard deviations for plasma and urine assays were less than 6% with low relative errors. The established HPLC methods were demonstrated to be useful for clinical pharmacokinetic studies after oral administration of S-1090. 相似文献
13.
M. J. Royer-Morrot M. Rambourg I. Jacob 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,581(2)
A reversed-phase liquid chromatographic method with ultraviolet detection for the determination of zopiclone in plasma is described. It is rapid, sensitive, reproducible and linear over a wide range. The method was used to study plasma zopiclone concentrations in a case of acute intoxication after oral ingestion of 300 mg of the drug. The plasma level was 1600 ng/ml 4.5 h after the dose and the elimination half-life was 3.5 h. 相似文献
14.
We report robust HPLC/UV methods for quantifying retinyl esters (RE), retinol (ROL), and retinal (RAL) applicable to diverse biological samples with lower limits of detection of 0.7, 0.2, and 0.2 pmol, respectively, and linear ranges greater than 3 orders of magnitude. These assays function well with small, complex biological samples (10-20 mg tissue). Coefficients of variation range from 5.9 to 10.0% (intraday) and from 5.9 to 11.0% (interday). Quantification of endogenous RE, ROL, and RAL in mouse serum and tissues (liver, kidney, adipose, muscle, spleen, testis, skin, brain, and brain regions) reveals utility. Ability to discriminate spatial concentrations of ROL and RE is illustrated with C57BL/6 mouse brain loci (hippocampus, cortex, olfactory bulb, thalamus, cerebellum, and striatum). We also developed a method to distinguish isomeric forms of ROL to investigate precursors of retinoic acid. The ROL isomer assay has limits of detection between 3.5 and 4.5 pmol and has a linear range and coefficient of variation similar to those of the ROL/RE and RAL assays. The assays described here provide for sensitive and rigorous quantification of endogenous RE, ROL, and RAL to elucidate retinoid homeostasis in disease states such as Alzheimer’s disease, type 2 diabetes, obesity, and cancer. 相似文献
15.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,734(1):63-71
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies. 相似文献
16.
LLerena A Dorado P Berecz R González A Jesús Norberto M de la Rubia A Cáceres M 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(1):25-31
A rapid high-performance liquid chromatographic method is described for the simultaneous determination of the widely used antidepressant drug, fluoxetine and its principal metabolite norfluoxetine in plasma. After liquid-liquid extraction the compounds were separated in a reversed-phase column and assayed by ultraviolet absorption at 226 nm. The analytical interference from psychoactive drugs and their metabolites was also studied. The extraction recoveries were 93 and 87% for norfluoxetine and fluoxetine, respectively. The limit of quantitation under the described conditions was 14 nmol/l for both compounds. The method was found to be reproducible with coefficients of variation less than 10%. A great variability in plasma concentrations of fluoxetine and norfluoxetine as well as in fluoxetine/norfluoxetine ratios was found among the 29 patients studied. This result suggests the implication of genetically polymorphic enzymes, presumably CYP2D6, CYP2C9 and CYP2C19 in the metabolism of fluoxetine to norfluoxetine. Therapeutic drug monitoring should thus be useful in patients treated with regular doses. 相似文献
17.
Cui Y Gurley B Ang CY Leakey J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,768(1):129-135
The role of the Mg2+ cation on antihypertensive molecule binding on human serum albumin (HSA) was studied by affinity chromatography. The thermodynamic data corresponding to this binding were determined for a wide range of Mg2+ concentrations (c). For the nifedipine molecule, an increase in the Mg2+ concentration produced a decrease in binding due to a decrease in the electrostatic interactions. For verapamil and diltiazem, which have the highest solvent accessible surface area, the solute binding on HSA was divided into two Mg2+ concentration regions. For a low c value below c(c) (approximately 1.6 mmol/l), the binding dependence with c was similar to that of nifedipine. For c above c(c) the hydrophobic effect created in the bulk solvent associated with a decrease in the van der Waals interactions between the solute molecule and the HSA implied a decrease in its binding. These results showed that for patients with hypertension, an Mg2+ supplementation during treatment with these antihypertensive molecules can increase the active pharmacological molecule concentration. 相似文献
18.
F. Kees M. Bucher G. Mair H. Grobecker 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,753(2):50
A high-performance liquid chromatographic method is described for the determination of opipramol in human plasma. Opipramol was extracted into tert.-butylmethyl ether, separated on a cyanopropyl silica column and detected at 254 nm. Imipramine was used as internal standard. The limit of quantitation was 250 pg/ml using 1.5 ml plasma. Precision was better than 9%, inaccuracy less than 8%. The assay is more sensitive than previously published methods, and it has been applied to the analysis of plasma samples from a pharmacokinetic study. 相似文献
19.
Determination of olanzapine in plasma by high-performance liquid chromatography using ultraviolet absorbance detection 总被引:2,自引:0,他引:2
Dusci LJ Peter Hackett L Fellows LM Ilett KF 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,773(2):191-197
A rapid method for the determination of olanzapine in plasma using high-performance liquid chromatography with ultra violet detection is described. Olanzapine was extracted from plasma with a mixture of hexane/dichloromethane (85:15), and then back extracted into phosphate buffer pH 2.8. Separation was achieved on a RP Select B C(18) column and commonly administered drugs did not interfere with the assay. The limit of quantitation was 1.5 microg/l and the inter-day and intra-day relative standard deviations were less than 10%. Olanzapine was shown to be stable in plasma for up to 7 days when stored at 4 degrees C. Moreover, the addition of ascorbic acid was not necessary for the achievement of chemical stability during storage, or during the assay procedure. The method has been used to measure olanzapine concentrations in patients treated with various doses of the drug varying from 5 to 40 mg/day. 相似文献
20.
Michele L. Foisy Jean-Pierre Sommadossi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,721(2):1377
A rapid, sensitive and specific high-performance liquid chromatography (HPLC) procedure for the quantification of indinavir, a potent human immunodeficiency virus (HIV) protease inhibitor, in human plasma is described. Following C18 solid-phase extraction, indinavir was chromatographed on a reversed-phase C8 column using a simple binary mobile phase of phosphate buffer–acetonitrile (60:40, v/v). UV detection at 210 nm led to an adequate sensitivity without interference from endogenous matrix components. The limit of quantification was 25 ng/ml with a 0.1 ml plasma sample. The standard curve was linear across the range from 25 to 2500 ng/ml with an average recovery of 91.4%. The mean relative standard deviations for concentrations within the standard curve ranged between 1.4 and 9.7%. Quality control standards gave satisfactory intra- and inter-assay precision (R.S.D. from 3.5 to 15.8%) and accuracy within 15% of the nominal concentration. Sample handling experiments, including HIV heat inactivation, demonstrated analyte stability under expected handling processes. The assay is suitable for the analysis of samples from adult and pediatric patients infected with HIV. 相似文献