1.
PurposeTo define optimal planning target volume (PTV) margins for intensity modulated radiotherapy (IMRT) ± knee-heel support (KHS) in patients treated with adjuvant radiotherapy.MethodsComputed tomography (CT) scans ± KHS of 10 patients were taken before and at 3rd and 5th week of treatment, fused and compared with initial IMRT plans.ResultsA PTV margin of 15 mm in anteroposterior (AP) and superoinferior (SI) directions and 5 mm in lateral directions were found to be adequate without any difference between ± KHS except for the SI shifts in CTV-primary at the 3rd week. Five mm margin for iliac CTV was found to be inadequate in 10–20% of patients in SI directions however when 7 mm margin was given for iliac PTV, it was found to be adequate. For presacral CTV, it was found that the most striking shift of the target volume was in the direction of AP. KHS caused significantly less volume of rectum and bladder in the treated volume.ConclusionsPTV margin of 15 mm in SI and AP, and 5 mm in lateral directions for CTV-primary were found to be adequate. A minimum of 7 mm PTV margin should be given to iliac CTV. The remarkable shifting in presacral CTV was believed to be due to the unforeseen hip malposition of obese patients. The KHS seems not to provide additional beneficial effect in decreasing the shifts both in CTV-primary and lymphatic, however it may have a beneficial effect of decreasing the OAR volume in PTV margins.  相似文献   

2.
PurposeTo assess the potential of cone beam CT (CBCT) derived adaptive RapidArc treatment for esophageal cancers in reducing the dose to organs at risk (OAR).Methods and materialsTen patients with esophageal cancer were CT scanned in free breathing pattern. The PTV is generated by adding a 3D margin of 1 cm to the CTV as per ICRU 62 recommendations. The double arc RapidArc plan (Clin_RA) was generated for the PTV. Patients were setup using kV orthogonal images and kV-CBCT scan was acquired daily during first week of therapy, then weekly. These images were exported to the Eclipse TPS. The adaptive CTV which includes tumor and involved nodes was delineated in each CBCT image set for the length of the PTV. The composite CTV from first week CBCT was generated using Boolean union operator and 5 mm margin was added circumferentially to generate adaptive PTV (PTV1). Adaptive RapidArc plan (Adap_RA) was generated. NTCP and DVH of the OARs of the two plans were compared. Similarly, PTV2 was generated from weekly CBCT. PTV2 was evaluated for the coverage of 95% isodose of Adap_RA plan.ResultsThe PTV1 and PTV2 volumes covered by 95% isodose in adaptive plans were 93.51 ± 1.17% and 94.59 ± 1.43% respectively. The lung V10Gy, V20Gy and mean dose in Adap_RA plan was reduced by 17.43% (p = 0.0012), 34.64% (p = 0.0019) and 16.50% (p = 0.0002) respectively compared to Clin_RA. The Adap_RA plan reduces the heart D35% and mean dose by 17.35% (p = 0.0011) and 17.16% (p = 0.0012). No significant reduction in spinal cord and liver doses were observed. NTCP for the lung (0.42% vs. 0.08%) and heart (1.39% vs. 0.090%) was reduced significantly in adaptive plans.ConclusionThe adaptive re-planning strategy based on the first week CBCT dataset significantly reduces the doses and NTCP to OARs.  相似文献   

3.
PurposeThe purpose of this work is to compare the positioning accuracy achieved by three different imaging techniques and planar vs. CBCT imaging for two common IGRT indications.MethodsA collective of prostate cancer and head-and-neck cancer patients treated at our institution during the year 2013 was retrospectively analyzed. For all treatment fractions (3078 in total), the kind of acquired set-up image and the performed couch shift before treatment were assessed. The distribution of couch corrections was compared for three different imaging systems available at our institution: the treatment beam line operating at 6 MV, a dedicated imaging beam line of nominally 1 MV, and the kVision system at 70–121 kV. Shifts were analyzed for planar and cone-beam CT images. Based on the set-up corrections, CTV to PTV expansion margins were calculated.ResultsThe difference in set-up corrections performed for the three energies and both techniques (planar vs. CBCT) was not significant for head-and-neck cancer patients. For prostate cancer all shifts had equal variance. Averages ranged from −0.7 to +0.7 mm. The set-up margins calculated on the basis of the observed shifts are 4.0 mm (AP) and 3.8 mm (SI, LR) for the head-and-neck PTV and 6.6 mm (SI), 6.7 mm (AP) and 7.9 mm (LR) for the prostate cancer patients.ConclusionsFor three different linac-based imaging energies and planar/CBCT imaging, no relevant differences in set-up shifts were observed. The suggested set-up margins for these indications are of the order of 4 mm for head-and-neck and 6–8 mm for prostate treatment.  相似文献   

4.
PurposeTo evaluate the impact of thermoplastic mask immobilization in the setup reproducibility and delivered dose for Helical Tomotherapy (HT) of the breast/chest wall.Methods16 patients treated with Accuray Hi-Art HT for breast-cancer were considered. Patients were positioned supine with arms extended above the head using Civco Wing Board (WB) system. In 50% of patients an Orfit thermoplastic mask was added in order to improve immobilization.Before each treatment fraction a megavoltage CT (MVCT) scan was taken and registered to the planning CT by experienced medical staff. The impact of thermoplastic mask was investigated analysing MVCT shift-roll data and MVCT dose distribution using Planned Adaptive software.ResultsIn the analysed cases, the addition of thermoplastic mask had minor impact on the lateral, longitudinal and roll data distribution. Variance of vertical shifts was significantly reduced in the WB + Orfit group. Van Herk's margins were not affected by addition of thermoplastic immobilization.In both groups, target coverage (V95) and maximum dose (D1) were almost identical to planned values. D1 of organs at risk were not significantly different in the two groups.ConclusionsAnalysis of shift-roll data shows no improvement in the group of patients immobilized with the addition of thermoplastic mask. Van Herk's margin is quite large (7–10 mm) in both groups evidencing the need to perform daily setup correction. The adapted dose distribution complies well with the planned one, showing that if MVCT is used before each treatment fraction, a 3 mm margin (setup component) for CTVs expansion could be adequate.  相似文献   

5.
PurposeTo evaluate the patients’ set-up error-induced perturbation effects on 4D dose distributions (4DDD) of range-adapted internal target volume-based (raITV) treatment plan using lung and liver 4DCT data sets.MethodsWe enrolled 20 patients with lung and liver cancer treated with respiratory-gated carbon-ion beam scanning therapy. PTVs were generated by adding a 2 mm range-adapted set-up margin on the raITVs. Set-up errors were simulated by shifting the beam isocenter in three translational directions of ±2 mm, ±4 mm, and ±6 mm. 4DDDs were calculated for both nominal and isocenter-shifted situations. Dose metrics of CTV dose coverage (D95) and normal tissue sparing were evaluated. Statistical significance with p < 0.01 was considered by Wilcoxon signed rank test.ResultsThe CTV dose coverage was more sensitive to set-up errors for lung cases than for liver cases, and more serious in superior-inferior direction. The sufficient CTV-D95 > 98% could be achieved with set-up errors less than ±2 mm in all shift directions both for lung and liver cases. With the increase of set-up error, the CTV dose coverage decreased gradually. The clinical criterial of CTV-D95 > 95% could not be fulfilled with set-up error reached to ±4 mm for lung cases, and ±6 mm for liver cases. OAR doses did not have a significant difference with each set-up error for both lung and liver cases.ConclusionsThe range-adapted set-up margin successfully prevented dose degradation of 4DDDs in the presence of the same magnitude of set-up error for raITV-based carbon-ion beam scanning therapy.  相似文献   

6.
In typical treatment planning of 3D IMRT, the incident energy fluence is optimized to achieve a homogeneous dose distribution to the PTV. The PTV includes the tumour but also healthy tissues that may have a different dose response for the same incident energy fluence, like bony structures included in the PTV (mandibles in head and neck tumours or femoral bones in sarcomas). Dose to medium optimization compensates for this heterogeneous response, leading to a non-homogeneous energy fluence in the PTV and a non-homogeneous dose in the CTV in the presence of geometric errors. We illustrate qualitatively this statement in a cylindrical geometry where the PTV includes a CTV (7 cm diameter) made of water surrounded by ICRU compact bone (1.2 cm thickness); such configuration was chosen to exaggerate the aforementioned effect. Optimization was performed assuming dose equals photon energy fluence times mass energy absorption coefficient. Bone has a 4% lower dose response in a 6 MV flattening filter free spectrum. After optimization either in medium or assuming everything as water composition, the geometry was shifted by 1.2 cm and dose recomputed. As expected, compensating for the under-response of the bone material during optimization in medium leads to an overdosage of the CTV when patient geometric errors are taken into account. Optimization in dose assuming everything as water composition leads to a uniform coverage. Robust optimization or forcing a uniform atomic composition in the PTV margin may resolve this incompatibility between the PTV concept and dose to medium optimization.  相似文献   

7.
PurposeThe aim of this study was to account for interfractional clinical target volume (CTV) shape variation and apply this to the planning target volume (PTV) margin for prostate cancer radiation treatment plans.MethodsInterfractional CTV shape variations were estimated from weekly cone-beam computed tomography (CBCT) images using statistical point distribution models. The interfractional CTV shape variation was taken into account in the van Herk’s margin formula. The PTV margins without and with the CTV shape variation, i.e., standard (PTVori) and new (PTVshape) margins, were applied to 10 clinical cases that had weekly CBCT images acquired during their treatment sessions. Each patient was replanned for low-, intermediate-, and high-risk CTVs, using both margins. The dose indices (D98 and V70) of treatment plans with the two margins were compared on weekly pseudo-planning computed tomography (PCT) images, which were defined as PCT images registered using a deformable image registration technique with weekly CBCT images, including contours of the CTV, rectum, and bladder.ResultsThe percentage of treatment fractions of patients who received CTV D98 greater than 95% of a prescribed dose increased from 80.3 (PTVori) to 81.8% (PTVshape) for low-risk CTVs, 78.8 (PTVori) to 87.9% (PTVshape) for intermediate-risk CTVs, and 80.3 (PTVori) to 87.9% (PTVshape) for high-risk CTVs. In most cases, the dose indices of the rectum and bladder were acceptable in clinical practice.ConclusionThe results of this study suggest that interfractional CTV shape variations should be taken into account when determining PTV margins to increase CTV coverages.  相似文献   

8.
BackgroundThe No Action Protocol (NAL) was used to diminish the systematic set-up error. Recently, owing to the development of image registration technologies, the on-line positioning control is more often used. This method significantly reduces the CTV–PTV margin at the expense of the lengthening of a treatment session. The efficiency of NAL in decreasing the total treatment time for Head&Neck patients was investigated.MethodsResults of set-up control of 30 patients were analyzed. The set-up control was carried out on-line. For each patient and each fraction, the set-error and the time needed for making the set-up control procedure were measured. Next, retrospectively, the NAL was applied to this data. The number of initial errors (without interventions) and after NAL protocol were compared in terms of errors larger than 3 and 4 mm. The average and total time used for portal control was calculated and compared.ResultsThe number of setup errors in the posterior-anterior, inferior-superior, and right–left directions ≥3 mm and ≥4 mm were 98, 79, and 91 sessions and 44, 38 and 30 sessions out of 884 sessions. After NAL protocol the number of errors ≥3 mm and ≥4 mm decreased to 84, 57, and 39 sessions and 31, 15 and 10 sessions, respectively. The average time needed for one set-up control was 5.1 min. NAL protocol allows saving 4049 min for the whole group.ConclusionsFor locations where the random set-up errors are small, the NAL enables a very precise treatment of patients. Implementation of this protocol significantly decreases the total treatment time.  相似文献   

9.
PurposeTo compare the planning target volume (PTV) margins needed for prostate patients who have used hydrogel spacer or rectal balloon during proton treatments.MethodTotal of 190 prostate patients treated with proton therapy during 2017 were selected for this study. Of these patients, 96 had hydrogel spacer injection and 94 patients had only rectal balloons insertion. All patients had implanted gold markers inside the prostate for daily target alignment. Post-treatment radigraphs were obtained to evaluate prostate intrafraction motion. The systematic and random components of patient setup residual error and prostate intrafraction motion error were obtained. PTV margins were calculated using the van Herk formula for both patient groups.ResultsFor setup residual error, the mean values in the superior-inferior (SI) direction and the variances in the left–right (LR) direction were statistically different between the two groups. For intrafraction motion, there were significant differences of the mean values in the SI direction and of the variances in both LR and anterior-posterior (AP) directions. The population PTV margins for hydrogel spacer group were 2.6 mm, 3.3 mm, and 1.6 mm in LR, SI, AP directions, respectively. For the rectal balloon group, the PTV margins were 2.1 mm, 3.1 mm, and 2.0 mm in LR, SI, AP directions, respectively.ConclusionStatistically significant differences were observed in the patient setup and prostate intrafraction motion errors of the two patient groups. However, under the current protocol of bladder preparation and daily marker-based x-ray image-guidance, population PTV margins were comparable between the two patient groups.  相似文献   

10.
PurposeImage guided adaptive radiotherapy (IGART) strategies can be used to include the temporal aspects of radiotherapy treatment. A dosimetric evaluation of on- and off-line adaptive strategies are done in this study.MethodsA library of equivalent uniform dose (EUD)-based Intensity Modulated Radiotherapy Treatment plans with incrementally increasing clinical target volume (CTV)-to-planning target volume (PTV) margins were developed for 10 patients. Utilizing daily computed tomography (CT) images an on-line strategy using a margin-of-the-day (MOD) concept that selects the best plan from the library was employed. This was compared to an off-line strategy with full analysis of accumulated dose between fractions where dosimetric deviations from the treatment intent triggered plan adaptation. A fixed margin treatment approach was used as benchmark.ResultsUsing fixed margins of <15 mm lead to under-dosages of more than 5 Gy in total delivered dose. The average CTV EUD for the off-line and on-line strategy was 50.0 ± 5.0 Gy and 50.4 ± 2.0 Gy respectively and OAR doses were comparable.ConclusionA fixed margin treatment approach yields a significant probability of CTV under-dosage. Using EUD dose metrics CTV coverage can be restored in both the off-line and on-line adaptive strategies at acceptable OAR dose levels. Considering the workload and time on the treatment machine, the off-line strategy proves to be sufficient and more practical.  相似文献   

11.
PurposeDue to limited field size of Magnetic Resonance Linear Accelerators (MR-Linac), some treatments could require a dual-isocenter planning approach to achieve a complete target coverage and thus exploit the benefits of the online adaptation. This study evaluates the dosimetric accuracy of the dual-isocenter intensity modulated radiation therapy (IMRT) delivery technique for MR-Linac.Material and MethodsDual-isocenter multi leaf collimator (MLC) and couch accuracy tests have been performed to evaluate the delivery accuracy of the system. A mono-isocenter plan delivered in clinical practice has then been retrospectively re-planned with dual-isocenter technique. The dual-isocenter plan has been re-calculated and delivered on a 3-dimensional (3D) ArcCHECK phantom and 2-dimensional (2D) films to assess its dosimetric accuracy in terms of gamma analysis. Clinical and planning target volume (CTV and PTV respectively) coverage robustness was then investigated after the introduction of ± 2 mm and ± 5 mm positioning errors by shifting the couch.ResultsMLC and couch accuracy tests confirmed the system accuracy in delivering a dual-isocenter irradiation.2D/3D gamma analysis results occurred always to be above 95% if considered a gamma criteria 1%/2 mm and 1%/1 mm respectively for the 2D and 3D analysis.The mean variations for CTV D98% and PTV V95% were 0.2% and 1.1% respectively when positioning error was introduced separately in each direction, while the maximum observed variations were 0.9% (CTV) and 3.7% (PTV).ConclusionThe dosimetric accuracy of dual-isocenter irradiation has been verified for MR-Linac, achieving accurate and robust treatment strategy and improving dose conformality also in presence of targets whose extension exceeds the nominal maximum field size.  相似文献   

12.
PurposeAccurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins.Materials and methodsThe internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors.ResultsThe mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively.ConclusionsOn-line image guidance with the ITV–CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT.  相似文献   

13.

Purpose

To investigate the impact of clinical target volume (CTV) shape and size on CTV to planning target volume (PTV) margin expansion.

Methods and Materials

Using numerical integration methods, margins accounting for random errors and systematic errors were calculated for CTVs of different shapes and sizes. We use and to represent the coefficients, for random errors and systematic errors, respectively, that ensure that every point of the CTV receives ≥95% of the prescribed dose.

Results

The part of the margin accounting for random errors depends on CTV shape and size; generally, a convex part of a CTV would have a larger margin than a concave part. However, the part of the margin accounting for systematic errors is independent of CTV shape and size.

Conclusions

CTV shape and size should be considered when generating a PTV. For a complex CTV, the margins of the various parts of the CTV are different and related to local forms.  相似文献   

14.
PurposeThis study aims to investigate the feasibility of using convolutional neural networks to predict an accurate and high resolution dose distribution from an approximated and low resolution input dose.MethodsSixty-six patients were treated for prostate cancer with VMAT. We created the treatment plans using the Acuros XB algorithm with 2 mm grid size, followed by the dose calculated using the anisotropic analytical algorithm with 5 mm grid with the same plan parameters. U-net model was used to predict 2 mm grid dose from 5 mm grid dose. We investigated the two models differing for the training data used as input, one used just the low resolution dose (D model) and the other combined the low resolution dose with CT data (DC model). Dice similarity coefficient (DSC) was calculated to ascertain how well the shape of the dose-volume is matched. We conducted gamma analysis for the following: DVH from the two models and the reference DVH for all prostate structures.ResultsThe DSC values in the DC model were significantly higher than those in the D model (p < 0.01). For the CTV, PTV, and bladder, the gamma passing rates in the DC model were significantly higher than those in the D model (p < 0.002–0.02). The mean doses in the CTV and PTV for the DC model were significantly better matched to those in the reference dose (p < 0.0001).ConclusionsThe proposed U-net model with dose and CT image used as input predicted more accurate dose.  相似文献   

15.
AimThe aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy.BackgroundRadiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks.Materials and methodsA total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated.ResultsThe best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p  0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior–inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm.ConclusionsSetup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.  相似文献   

16.
AimPatient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose.BackgroundRT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results.Materials and methodsThe formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1–2, C5–7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula.ResultsSystematic residual errors of the landmarks were reduced maximally by 49.8% (p  0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible.ConclusionsRemarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.  相似文献   

17.
BackgroundIntensity Modulated Arc Therapy (IMAT) can be planned and delivered via several techniques. Advanced Radiotherapy (ARTORL) is a prospective study that aims to evaluate the treatment costs and clinical aspects of implementing these IMAT techniques for head and neck cancers. In this context, we evaluated the potential dosimetric gain of Helical Tomotherapy (TomoTherapy, Accuray, HT) versus VMAT (Rapid'Arc®, Varian Medical System, RA) for oropharyngeal cancer (OC).Material and methodsThirty patients were selected from our database in whom bilateral neck irradiation and treatment to the primary were indicated. Each patient was planned twice using both HT and RA planning systems using a simultaneous integrated boost approach. For the planning target volumes (PTV) and organs at risk, ICRU 83 reporting guidelines were followed. RA and HT plans were compared using paired Student's t-test.ResultsRA and HT produced plans with a good coverage of PTVs and acceptable sparing of OARs. Although some dosimetric differences were statistically significant, they remained small. However, the near maximal dose to the PRV of spinal cord and brain stem was lower with HT. Regarding normal tissue, HT increased the volume irradiated at doses between 4 and 20 Gy compared to RA.ConclusionIn OC, HT and RA showed similar dosimetric results. They represent the maximum gains obtained with photon beams. The medicoeconomic evaluation of our study is ongoing and may reveal differences between these techniques in terms of MU number, fraction time, and clinical evaluation.  相似文献   

18.
19.
This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ - 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.  相似文献   

20.
摘要 目的:探究锥形束CT(CBCT)引导放疗摆位误差对中上段食管癌患者受照射剂量的影响。方法:选取2017年5月~2019年5月于我院收治的60例中上段食管癌患者为研究对象,所有患者均行CBCT图像、计划CT图像采集。在患者放疗前进行CBCT扫描,将CBCT图像与计划CT图像匹配,得到左右(x轴)、头脚(y轴)、前后(z轴)三个方向的线性误差,分析出现的误差及误差的分布规律。利用模拟实际照射系统,进行模拟计划,得到实际照射靶区及正常组织受照射剂量,将其与治疗前计划比较,研究摆位误差对患者受照剂量的影响。结果:患者整体摆位误差为x轴(2.91±2.20)mm,y轴(3.89±2.17)mm,z轴(2.44±1.64)mm,x轴的MPTV为4.054 mm,y轴的MPTV为8.183 mm,z轴的MPTV为3.482 mm。模拟计划的CI、PTV的Dmin、Dmean、D95%均低于标准计划差异显著(P均<0.05),而模拟计划的HI低于标准计划(P<0.05)。模拟计划的脊髓Dmax高于标准计划(P<0.05),而标准计划与模拟计划的双肺V20、Dmean,心脏V40差异比较无统计学意义(P均>0.05)。结论:CBCT引导放疗摆位误差对中上段食管癌患者影响较小,提高PTV受照射剂量及治疗准确程度,对脊髓有保护效果。摆位误差对心、肺的剂量分布无明显影响。  相似文献   