1.
PurposeAccurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins.Materials and methodsThe internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors.ResultsThe mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively.ConclusionsOn-line image guidance with the ITV–CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT.  相似文献   

2.
AimThe aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy.BackgroundRadiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks.Materials and methodsA total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated.ResultsThe best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p  0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior–inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm.ConclusionsSetup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.  相似文献   

3.
PurposeTo show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system.MethodsA method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images. A TD treatment was simulated on a chest phantom equipped with a breast attachment. MVCT and MV2D images were performed for 7 different shifted positions of the phantom and registered by 10 different operators with the simulation kilovoltage CT images.ResultsCompared to MVCT, MV2D imaging reduces the dose by a factor of up to 45 and the acquisition time by a factor of up to 49. Comparing the registration shift values obtained for the phantom images obtained with MVCT in the coarse mode to those obtained with MV2D, the mean difference is 1.0 ± 1.1 mm, −1.1 mm ± 1.1, and −0.1 ± 2.2 mm, respectively, in the lateral, longitudinal, and vertical directions.ConclusionsWith dual advantages (very fast imaging and a potentially reduced dose to the heart and contralateral organs), MV2D topographic images may be an attractive alternative to MVCT for the localization of breast cancer patients treated with TomoDirect.  相似文献   

4.
The aim of this study was to quantify the tibio-femoral contact point (CP) locations in healthy and osteoarthritic (OA) subjects during a weight-bearing squat using stand-alone biplanar X-ray images.Ten healthy and 9 severe OA subjects performed quasi-static squats. Bi-planar X-ray images were recorded at 0°, 15°, 30°, 45°, and 70° of knee flexion. A reconstruction/registration process was used to create 3D models of tibia, fibula, and femur from bi-planar X-rays and to measure their positions at each posture. A weighted centroid of proximity algorithm was used to calculate the tibio-femoral CP locations. The accuracy of the reconstruction/registration process in measuring the quasi-static kinematics and the contact parameters was evaluated in a validation study.The quasi-static kinematics data revealed that in OA knees, adduction angles were greater (p<0.01), and the femur was located more medially relative to the tibia (p<0.01). Similarly, the average CP locations on the medial and lateral tibial plateaus of the OA patients were shifted (6.5±0.7 mm; p<0.01) and (9.6±3.1 mm; p<0.01) medially compared to the healthy group. From 0° to 70° flexion, CPs moved 8.1±5.3 mm and 8.9±5.3 mm posteriorly on the medial and lateral plateaus of healthy knees; while in OA joints CPs moved 10.1±8.4 mm and 3.6±2.8 mm posteriorly. The average minimum tibio-femoral bone-to-bone distances of the OA joints were lower in both compartments (p<0.01).The CPs in the OA joints were located more medially and displayed a higher ratio of medial to lateral posterior translations compared to healthy joints.  相似文献   

5.
Numerous techniques have been employed to monitor humeral head translation due to its involvement with several shoulder pathologies. However, most of the techniques were not validated. The objective of this study is to compare the accuracy of manual digitization and contour registration in measuring superior translation of the humeral head. Eight pairs of cadaver scapulae and humerii bones were harvested for this study. Each scapula and humerus was secured in a customized jig that allowed for control of humeral head translations and a vise that permitted rotations of the scapula about three axes. Fluoroscopy was used to take images of the shoulder bones. Scapular orientation was manipulated in different positions while the humerus was at 90° of humeral elevation in the scapular plane. Humeral head translation was measured using the two methods and was compared to the known translation. Additionally, accuracy of the contour registration method to measure 2-D scapular rotations was assessed. The range for the root mean square (RMS) error for manual digitization method was 0.27 mm - 0.43 mm and the contour registration method had a RMS error ranging from 0.18 mm - 0.40 mm. In addition, the RMS error for the scapular angle rotation using the contour registration method was 2.4°. Both methods showed acceptable errors. However, on average, the contour registration method showed lesser measurement error compared to the manual digitization method. In addition, the contour registration method was able to show good accuracy in measuring rotation that is useful in 2-D image analysis.  相似文献   

6.
Due to noises, speckles, etc., automatic prostate segmentation is rather challenging, and using only low-level information such as intensity gradient is insufficient and unable to tackle the problem. In this paper, we propose an automatic prostate segmentation method combining intrinsic properties of TRUS images with the high-level shape prior information. First, intrinsic properties of TRUS images, such as the intensity transition near the prostate boundary as well as the speckle induced texture features obtained by Gabor filter banks, are integrated to deform the model to the target contour. These properties make our method insensitive to high gradient regions introduced by noises and speckles. Then, the preliminary segmentation is fine-tuned by the non-parametric shape prior, which is optimally distilled by non-parametric kernel density estimation as it can approximate arbitrary distributions. The refinement is along the direction of mean shift vector, and considerably strengthens the robustness of the method. The performance of our method is validated by experimental results. Compared with the state of the art, the accuracy and robustness of the method is quite promising, and the mean absolute distance is only 1.21 ± 0.85 mm.  相似文献   

7.
Image registration, the process of optimally aligning homologous structures in multiple images, has recently been demonstrated to support automated pixel-level analysis of pedobarographic images and, subsequently, to extract unique and biomechanically relevant information from plantar pressure data. Recent registration methods have focused on robustness, with slow but globally powerful algorithms. In this paper, we present an alternative registration approach that affords both speed and accuracy, with the goal of making pedobarographic image registration more practical for near-real-time laboratory and clinical applications. The current algorithm first extracts centroid-based curvature trajectories from pressure image contours, and then optimally matches these curvature profiles using optimization based on dynamic programming. Special cases of disconnected images (that occur in high-arched subjects, for example) are dealt with by introducing an artificial spatially linear bridge between adjacent image clusters. Two registration algorithms were developed: a ‘geometric’ algorithm, which exclusively matched geometry, and a ‘hybrid’ algorithm, which performed subsequent pseudo-optimization. After testing the two algorithms on 30 control image pairs considered in a previous study, we found that, when compared with previously published results, the hybrid algorithm improved overlap ratio (p=0.010), but both current algorithms had slightly higher mean-squared error, assumedly because they did not consider pixel intensity. Nonetheless, both algorithms greatly improved the computational efficiency (25±8 and 53±9 ms per image pair for geometric and hybrid registrations, respectively). These results imply that registration-based pixel-level pressure image analyses can, eventually, be implemented for practical clinical purposes.  相似文献   

8.
Research has raised a growing concern about the accuracy of rescaled generic musculoskeletal models for estimating a subject's musculoskeletal geometry. Information extracted from magnetic resonance (MR) images can improve the subject-specific detail and accuracy of musculoskeletal models. Nevertheless, methods that allow efficient, automated definition of subject-specific muscular models for use in biomechanical analysis of gait have not yet been published to the best of our knowledge. We report a novel method for automated definition of subject-specific muscle paths using non-rigid image registration between an atlas image and the subject's MR images. We validated this approach quantitatively by measuring the distance between automatically and manually defined coordinates of muscle attachment sites. Data was collected for 34 muscles in each lower limb of 5 paediatric subjects diagnosed with diplegic cerebral palsy and presenting varying degrees of increased femoral anteversion. Distances showed an overall median Euclidean error of 6.1 mm: 2.0 mm along the medio-lateral direction, 1.8 mm along the anterior–posterior direction and 3.8 mm along the superior–inferior direction. A qualitative validation between automatically defined muscle points and the muscular geometry observed in the subject's medical image data corroborated the quantitative validation. This automated approach followed by visual inspection and, if needed, correction to the muscle paths, reduced the time required for defining 34 lower-limb muscle paths from around 3.5 to 1 h. Furthermore, the method was also applicable to aberrant skeletal geometry. Using the proposed method, defining MR-based musculoskeletal models becomes a time efficient and more accurate alternative to rescaling generic models.  相似文献   

9.
Rotator cuff (RC) tears may be associated with increased glenohumeral instability; however, this instability is difficult to quantify using currently available diagnostic tools. Recently, the three-dimensional (3D) reconstruction and registration method of the scapula and humeral head, based on sequences of low-dose biplane X-ray images, has been proposed for glenohumeral displacement assessment. This research aimed to evaluate the accuracy and reproducibility of this technique and to investigate its potential with a preliminary application comparing RC tear patients and asymptomatic volunteers. Accuracy was assessed using CT scan model registration on biplane X-ray images for five cadaveric shoulder specimens and showed differences ranging from 0.6 to 1.4 mm depending on the direction of interest. Intra- and interobserver reproducibility was assessed through two operators who repeated the reconstruction of five subjects three times, allowing defining 95% confidence interval ranging from ±1.8 to ±3.6 mm. Intraclass correlation coefficient varied between 0.84 and 0.98. Comparison between RC tear patients and asymptomatic volunteers showed differences of glenohumeral displacements, especially in the superoinferior direction when shoulder was abducted at 20° and 45°. This study thus assessed the accuracy of the low-dose 3D biplane X-ray reconstruction technique for glenohumeral displacement assessment and showed potential in biomechanical and clinical research.  相似文献   

10.
IntroductionTo commission the Monte Carlo (MC) algorithm based model of CyberKnife robotic stereotactic system (CK) and evaluate the feasibility of patient specific QA using the ArcCHECK cylindrical 3D-array (AC) with Multiplug inserts (MP).ResultsFour configurations were used for simple beam setup and two for patient QA, replacing water equivalent inserts by lung. For twelve collimators (5–60 mm) in simple setup, mean (SD) differences between MC and RayTracing algorithm (RT) of the number of points failing the 3%/1 mm gamma criteria were 1(1), 1(3), 1(2) and 1(2) for the four MP configurations. Tracking fiducials were placed within AC for patient QA. Single lung insert setup resulted in mean gamma-index 2%/2 mm of 90.5% (range [74.3–95.9]) and 82.3% ([66.8–94.5]) for MC and RT respectively, while 93.5% ([86.8–98.2]) and 86.2% ([68.7–95.4]) in presence of largest inhomogeneities, showing significant differences (p < 0.05).DiscussionAfter evaluating the potential effects, 1.12 g/cc PMMA and 0.09 g/cc lung material assignment showed the best results. Overall, MC-based model showed superior results compared to RT for simple and patient specific testing, using a 2%/2 mm criteria. Results are comparable with other reported commissionings for flattening filter free (FFF) delivery. Further improvement of MC calculation might be challenging as Multiplan has limited material library.ConclusionsThe AC with Multiplug allowed for comprehensive commissioning of CyberKnife MC algorithm and is useful for patient specific QA for stereotactic body radiation therapy. MC calculation accuracy might be limited due to Multiplan’s insufficient material library; still results are comparable with other reported commissioning measurements using FFF beams.  相似文献   

11.
AimPatient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose.BackgroundRT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results.Materials and methodsThe formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1–2, C5–7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula.ResultsSystematic residual errors of the landmarks were reduced maximally by 49.8% (p  0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible.ConclusionsRemarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.  相似文献   

12.
PurposeTo evaluate the spatial accuracy of a frameless cone-beam computed tomography (CBCT)-guided cranial radiosurgery (SRS) using an end-to-end (E2E) phantom test methodology.Methods and materialsFive clinical SRS plans were mapped to an acrylic phantom containing a radiochromic film. The resulting phantom-based plans (E2E plans) were delivered four times. The phantom was setup on the treatment table with intentional misalignments, and CBCT-imaging was used to align it prior to E2E plan delivery. Comparisons (global gamma analysis) of the planned and delivered dose to the film were performed using a commercial triple-channel film dosimetry software. The necessary distance-to-agreement to achieve a 95% (DTA95) gamma passing rate for a fixed 3% dose difference provided an estimate of the spatial accuracy of CBCT-guided SRS. Systematic (∑) and random (σ) error components, as well as 95% confidence levels were derived for the DTA95 metric.ResultsThe overall systematic spatial accuracy averaged over all tests was 1.4 mm (SD: 0.2 mm), with a corresponding 95% confidence level of 1.8 mm. The systematic (Σ) and random (σ) spatial components of the accuracy derived from the E2E tests were 0.2 mm and 0.8 mm, respectively.ConclusionsThe E2E methodology used in this study allowed an estimation of the spatial accuracy of our CBCT-guided SRS procedure. Subsequently, a PTV margin of 2.0 mm is currently used in our department.  相似文献   

13.
Identifying spinal instability is an important aim for proper surgical treatment. Analysis of functional X-ray images delivers measurements of the range of motion (RoM) and the center of rotation (CoR). In today's practice, CoR determination is often omitted, due to the lack of accurate methods. The aim of this work was to investigate the accuracy of a new analysis software (FXA?) based on an in vitro experiment.Six bovine spinal specimens (L3-4) were mounted in a robot (KR125, Kuka). CoRs were predefined by locking the robot actuator tool center point to the estimated position of the physiologic CoR and taking a baseline X-ray. Specimens were deflected to various RoMpreset flexion/extension angles about the CoRpreset. Lateral functional radiographs were acquired and specimen movements were recorded using an optical motion tracking system (Optotrak Certus). RoM and CoR errors were calculated from presets for both methods. Prior to the experiment, the FXA? software was verified with artificially generated images.For the artificial images, FXA? yielded a mean RoM-error of 0.01±0.03° (bias±standard deviation). In the experiment, RoM-error of the FXA?-software (deviation from presets) was 0.04±0.13°, and 0.10±0.16° for the Optotrak, respectively. Both correlated with 0.998 (p<0.001). For RoM<1.0°, FXA? determined CoR positions with a bias>20 mm. This bias progressively decreased from RoM=1° (bias=6.0 mm) to RoM=9° (bias<1.5 mm).Under the assumption that CoR location variances <5 mm are clinically irrelevant on the lumbar spine, the FXA? method can accurately determine CoRs for RoMs>1°. Utilizing FXA?, polysegmental RoMs, CoRs and implant migration measurements could be performed in daily practice.  相似文献   

14.
PurposeThe purpose of our study is to evaluate the challenges in identification of postoperative complexes (POC), the utility of clips in delineation of clinical target volume for boost in LABC downstaged with neoadjuvant chemotherapy (NACT) and to correlate this with patterns of recurrence.Methods and materialsLABC patients who underwent NACT followed by BCS and radiotherapy (2007–2014) were the subject of our analysis. The data on visibility and characteristics of postoperative cavity (POC), concordance of its volume with clip volume on radiation planning scan were retrieved. A 1 cm margin beyond POC was delineated as a clinical target volume (CTV). Postoperative whole breast and supraclavicular radiotherapy (50 Gy/25fractions/5wk or 42.4 Gy/16#/3 wk) followed by boost (10−16 Gy/5-8#/1–1.5wk) were delivered. Patterns of recurrence were evaluated.ResultsOut of 60 patients, 28.3% patients had stage II disease and 71.7% had stage III disease. 25% patients achieved pathological CR (complete response). The median POC volume was 30 cc and the median clip volume was 40 cc. The concordance of POC volume with clip volume was seen in 80%. Clips served as a good surrogate for POC in 80% of patients. At a median follow-up of 65 months (IQ range 32–84 months), and a lost to follow-up rate of 11.6 %, 3.3% (n = 2) patients had local recurrence (LR) and 8.3% (n = 5) had regional recurrence (LRR) in the supraclavicular region.ConclusionsDelineation of post NACT excision cavity as POC for boost radiotherapy is safe. Clips serve as a good surrogate for CTV delineation in 75% patients.  相似文献   

15.
BackgroundHIFU can achieve PVI, but severe esophageal complications have happened. We analyzed relative position of HIFU balloon catheter (BC) to esophageal temperature (ET) probe and correlated it to ET changes.Methods and ResultsBefore each ablation relative position of HIFU BC to ET probe was recorded in RAO 30° and LAO 40°. We compared ablations where ET at end of ablation was < 38.5°C or ≥ 38.5°C and < 40.0°C or ≥ 40.0°C.A total of 600 images from 311 ablations in 28 patients (18 male, age 63 ± 7 years), were analyzed. ET ≥ 38.5°C was reached when distance from BC to ET probe was: < 20 mm in LAO for RSPV and < 29 mm in LAO for RIPV. For RIPV ET ≥ 38.5°C was reached when angle between BC and ET probe was significantly smaller in LAO and RAO. ET ≥ 40.0°C was reached when distance of BC to ET probe was: < 20 mm in LAO for RIPV, < 14 mm in RAO for RIPV, < 18 mm in RAO for LIPV. ET increased to ≥ 40.0°C when distance from BC to ET probe was significantly longer in LAO for LIPV. For RIPV ET ≥ 40.0°C was reached when angle between BC and ET probe was significantly smaller in LAO.ConclusionsThere is a relationship between distance/angle of HIFU BC to ET probe and ET: shorter distances and smaller angles can cause higher ET.  相似文献   

16.
The aim of this study was to evaluate the accuracy with which mobile biplane X-ray imaging can be used to measure patellofemoral kinematics of the intact knee during overground gait. A unique mobile X-ray imaging system tracked and recorded biplane fluoroscopic images of two human cadaver knees during simulated overground walking at a speed of 0.7 m/s. Six-degree-of-freedom patellofemoral kinematics were calculated using a bone volumetric model-based method and the results then compared against those derived from a gold-standard bead-based method. RMS errors for patellar anterior translation, superior translation and lateral shift were 0.19 mm, 0.34 mm and 0.37 mm, respectively. RMS errors for patellar flexion, lateral tilt and lateral rotation were 1.08°, 1.15° and 1.46°, respectively. The maximum RMS error for patellofemoral translations was approximately one-half that reported previously for tibiofemoral translations using the same mobile X-ray imaging system while the maximum RMS error for patellofemoral rotations was nearly two times larger than corresponding errors reported for tibiofemoral rotations. The lower accuracy in measuring patellofemoral rotational motion is likely explained by the symmetric nature of the patellar geometry and the smaller size of the patella compared to the tibia.  相似文献   

17.
Dual-isotope SPECT (DI-SPECT) studies offer significant advantages over sequential scans, foremost among them faster acquisition and perfect image registration. However, reconstructed images may be affected by substantial cross-talk contamination rendering them inadequate for diagnosis. This effect is especially strong for isotopes with close photopeak energies, such as 99mTc (140 keV) and 123I (159 keV). In this paper we present an iterative DI-SPECT reconstruction method which includes accurate, analytically computed scatter corrections provided by the APD (analytical photon distribution) algorithm. This algorithm calculates first and second order Compton scatter (based on the Klein–Nishina formula) and first order Rayleigh scatter. Both self-scatter and cross-talk between the two isotopes are evaluated using patient specific attenuation maps and an initial activity distribution estimate. To validate our method we performed experiments using the Data Spectrum, Inc. thorax phantom and a SPECT/CT camera system. Reconstructed images demonstrate significant improvement in data quantitation. Their quantitative accuracy increases up to a factor of two, even for activity ratios which strongly enhance cross-talk effects and seriously degrade projections.  相似文献   

18.
The rising cost of musculoskeletal pathology, disease, and injury creates a pressing need for accurate and reliable methods to quantify 3D musculoskeletal motion, fostering a renewed interest in this area over the past few years. To date, cine-phase contrast (PC) MRI remains the only technique capable of non-invasively tracking in vivo 3D musculoskeletal motion during volitional activity, but current scan times are long on the 1.5T MR platform (~2.5 min or 75 movement cycles). With the clinical availability of higher field strength magnets (3.0T) that have increased signal-to-noise ratios, it is likely that scan times can be reduced while improving accuracy. Therefore, the purpose of this study is to validate cine-PC MRI on a 3.0T platform, in terms of accuracy, precision, and subject-repeatability, and to determine if scan time could be minimized. On the 3.0T platform it is possible to limit scan time to 2 min, with sub-millimeter accuracy (<0.33 mm/0.97°), excellent technique precision (<0.18°), and strong subject-repeatability (<0.73 mm/1.10°). This represents reduction in imaging time by 25% (42 s), a 50% improvement in accuracy, and a 72% improvement in technique precision over the original 1.5T platform. Scan time can be reduced to 1 min (30 movement cycles), but the improvements in accuracy are not as large.  相似文献   

19.
PurposeWithin the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis.MethodsTest objects were imaged at 38 keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated.ResultsFor a voxel size of (60 μm)3, images without phase retrieval showed higher spatial resolution (6.7 mm−1 at 10% MTF) than corresponding images with phase retrieval (2.5 mm−1). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130 μm could be detected in both types of images.ConclusionsThe investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise.  相似文献   

20.
We recently developed a simple noninvasive 123I-IMP microsphere (SIMS) method using chest dynamic planar images and brain single photon emission computed tomography. The SIMS method is an automatic analysis method, except for the process of setting the region of interest (ROI) of the input function. If a fully automatic ROI setting algorithm can be developed to determine the input function for the SIMS method, repeatability and reproducibility of the analysis of regional cerebral blood flow (rCBF) of the SIMS method can be guaranteed. The purpose of this study is to develop a fully automatic input function determination program for the SIMS method and to confirm the clinical usefulness of this program.The automatic input function determination program consists of two ROI setting programs for the PA and lung regions, and it is developed using the image phase analysis of a chest RI angiogram. To confirm the clinical usefulness of this program, the rCBF in 34 patients measured using the automatic method were compared with the values obtained through the manual setting method.Input functions by the automatic and manual methods were approximately equal. A good correlation was observed between the rCBF values obtained by the automatic method and those obtained by the manual setting method (r = 0.96, p < 0.01).Further, the total time taken for the automatic SIMS analysis is 1–2 min as compared to 20–30 min for the current analysis, and therefore, this technique contributes to the improvement of the throughput of nuclear medical examinations.  相似文献   