首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 8 毫秒
1.
The design and construction of a pressure- and flow-insensitive reference liquid junction for use in ion concentration electrode measuring systems is described. The junction is inexpensive, is very easily and rapidly constructed, is rugged, and is adaptable to various applications. When used in a pH-measuring system, drift, pressure artifacts, and flow artifacts are negligible. The response time of the system appears to be less than 10 ms. Using the pH electrode device as described, the dissociation reaction rate constant of H2CO3 at 24 degrees C was determined to be 22 s-1.  相似文献   

2.
Long term recordings of bioelectric potential have often been done by a pair of conventional polarizable electrodes, especially in field works. Such electrodes are apt to produce a big potential difference due to incidental polarization. We developed an electrode system which consists of unpolarizable Ag/AgCl type electrodes, liquid salt bridges and paraffin-coated injection needle which was stuck into the xylem apoplast. To avoid the invasion of air which often cuts the liquid junction between the electrodes and the xylem fluid, a tiny hydrostatic pressure (ca. 1 kPa, 10 cm difference in water level) was always applied to the liquid in the salt bridge. This simple device enabled us to continue long ter recording of the xylem potential over two months. We present in this paper the theoretical basis to get informations, without destruction of the plant bodies, about the physiological state of the root system under-ground by the observation of the xylem potential. A model experiment was carried out to warrant the theory.  相似文献   

3.
目的: 通过对比内置和外置参考电极的微丝电极阵列在记录大鼠脑神经元放电过程中的优缺点,优化微丝电极阵列的制作与埋置,为多通道电生理实时记录系统提供更加实惠、优异的媒介工具。方法: 采用镍铬合金丝、电路板、电极引脚和地线(银线)制作16通道的微丝电极阵列,通过内置(参考电极与电极阵列并列排布)或外置(参考电极与地线分别焊接在电极一侧的两端)微丝电极阵列的参考电极,观察对比两种电极在记录大鼠ACC脑区神经元放电中的区别。实验大鼠分为内置组(8只)和外置组(9只),检测指标有信噪比(n=8)、放电幅度(n=380)和放电频率(n=54)。结果: 内置与外置参考电极的微丝电极阵列均可顺利记录出大鼠ACC脑区神经元的电信号;与外置组相比,内置组的神经元电信号具有信噪比高(P<0.05)、背景信号幅度小、受噪音干扰小,和放电幅度大(P<0.05)的优点;锋电位放电频率没有显著差异(P>0.05)。结论: 在记录大鼠ACC脑区神经元电活动时,内置参考电极的微丝电极阵列记录到更高信噪比、更大放电幅度的电信号,为多通道电生理技术提供更加可靠的工具。  相似文献   

4.
5.
We have studied topographical differences in averaged EEG amplitudes in alpha domain recorded in 10–20 system during “eyes closed” test. These differences appeared due to the use of 13 reference schemes: top and bottom of the chin (P1, P2); nose (N); top and bottom of the back of the neck (Sh1, Sh2); upper back (C); united electrodes at the base of the neck anteriorly and posteriorly (2Sh); united, ipsilateral, and individual ear electrodes (A12, Sym, A1, A2); vertex (Cz); and averaged reference (AR). Six experiments for each of the ten subjects were carried out with grounded and ungrounded states of three distant basic references P2, C, and 2Sh. Pairwise comparisons of topographic consistency of 13 reference schemes were carried out on the proposed complex of three independent indicators with evaluative criterion, followed by centroid-based clustering of the reference schemes and its discriminant verification. As a result, we have established (1) that most coordinated topography is provided by the following reference electrodes—A12, P1, P2, Sym; (2) reference electrodes A1, Sh2, A2, Sh1, AR, Cz are characterized by individually varying topography, which may lead to contradictory conclusions obtained when they are used; (3) no significant reasons have been found for preferring a grounded (neutral) states of reference electrodes, that makes the search for or mathematical construct of an infinitely remote neutral reference electrode less important.  相似文献   

6.
Many organic anions bind free Ca2+, the total concentration of which must be adjusted in experimental solutions. Because published values for the apparent dissociation constant (Kapp) describing the Ca2+ affinity of short chain fatty acids (SCFAs) and gluconate are highly variable, Ca2+ electrodes coupled to either a 3 M KCl or a Na+ selective electrode were used to redetermine Kapp. All solutions contained 130 mM Na+, whereas the concentration of the studied anion was varied from 15 to 120 mM, replacing Cl that was decreased concomitantly to maintain osmolarity. This induces changes in the liquid junction potential (LJP) at the 3 M KCl reference electrode, leading to a systematic underestimation of Kapp if left uncorrected. Because the Na+ concentration in all solutions was constant, a Na+ electrode was used to directly measure the changes in the LJP at the 3 M KCl reference, which were under 5 mV but twice those predicted by the Henderson equation. Determination of Kapp either after correction for these LJP changes or via direct reference to a Na+ electrode showed that SCFAs do not bind Ca2+ and that the Kapp for the binding of Ca2+ to gluconate at pH 7.4, ionic strength 0.15 M, and 23 °C was 52.7 mM.  相似文献   

7.
Germination experiments with specific germination mutants of Bacillus subtilis, including a newly isolated mutant affected in pressure-induced germination, suggest that a pressure of 100 MPa triggers the germination cascades that are induced by the nutrient germinant alanine (Ala) and by a mixture of asparagine, glucose, fructose, and potassium ions (AGFK), by activating the receptors for alanine and asparagine, GerA and GerB, respectively. As opposed to germination at 100 MPa, germination at 600 MPa apparently short-cuts at least part of the Ala- and AGFK-induced germination pathways. Inhibitors of nutrient-induced germination (HgCl(2) and Nalpha-P-tosyl-L-arginine methyl ester) also inhibit pressure-induced germination at 600 MPa, suggesting that germination at 600 MPa involves activation of a true physiological germination pathway and is therefore not merely a physico-chemical process in which water is forced into the spore protoplast.  相似文献   

8.
We studied monocular pattern ERG (PERG) in 10 normal subjects and a patient with optic neuritis. No clinically significant PERG could be recorded from the occluded eye with any reference (ipsilateral ear or temple, or midfrontal), indicating that cross-contamination is not present with binocular testing. Ipsilateral temple reference minimized VEP (P100/N100) contribution to the PERG N95 which occurred with ipsilateral ear or midfrontal reference. The conclusions were confirmed by results from the patient, who had marked monocular delay of a normal amplitude P100. Twenty-four subjects were tested with monocular and binocular stimulation using an ipsilateral temple reference. There were differences in PERG latencies and amplitudes although the interside amplitude ratio showed smaller differences with binocular stimulation. Increasing check size (17, 35 and 70 min) decreased P50 and N95 latencies and increased P50 amplitude.  相似文献   

9.
By replacing the glass-based pH electrode (L. R. Pucacco, S. K. Corona, H. R. Jacobson, and N. W. Carter (1986) Anal. Biochem. 153, 251-261) with a liquid membrane-based pH electrode, a relatively easy-to-manufacture modified Thomas electrode has been developed. The liquid membrane-based modified Thomas electrode can be manufactured without the special equipment (forge) and materials (glass) required to make the glass membrane pH microelectrode (L. R. Pucacco and N. W. Carter (1976) Anal. Biochem. 73, 501-512). The sensitivity (57.4 +/- 0.22 mV/pH unit), response time (20.0 +/- 2.67 s), and electrical resistance (3.48 +/- 0.67 X 10(11) ohm) of this electrode are similar to those of the glass-based version.  相似文献   

10.
The electrochemistry of L-cysteine (CySH) in neutral aqueous media was investigated using carbon ionic liquid electrode (CILE). Comparative experiments were carried out using glassy carbon electrodes. At CILE, highly reproducible and well-defined cyclic voltammograms were obtained for l-cysteine with a peak potential of 0.49V vs Ag/AgCl, showing that CILE manifests a good electrocatalytic activity toward oxidation of l-cysteine. A linear dynamic range of 2-210microM with an experimental detection limit of 2microM was obtained. The method was successfully applied to the determination of l-cysteine in a sample of soya milk. Cysteine oxidation at CILE does not result in deactivation of the electrode surface. Mechanistic studies showed that, at CILE, the overall CySH oxidation is controlled by the oxidation of the CyS(-) electroactive species.  相似文献   

11.
12.
13.
A linear sweep voltammetric method is used for direct simultaneous determination of l-cysteine and l-cysteine disulfide (cystine) based on carbon ionic liquid electrode. With carbon ionic liquid electrode as a high performance electrode, two oxidation peaks for l-cysteine (0.62 V) and l-cysteine disulfide (1.3 V) were observed with a significant separation of about 680 mV (vs. Ag/AgCl) in phosphate buffer solution (pH 6.0). The linear ranges were obtained as 1.0–450 and 5.0–700 μM and detection limits were estimated to be 0.298 and 4.258 μM for l-cysteine and l-cysteine disulfide, respectively. This composite electrode was applied for simultaneous determination of l-cysteine and l-cysteine disulfide in two real samples, artificial urine and nutrient broth. Satisfactory results were obtained which clearly indicate the applicability of the proposed electrode for simultaneous determination of these compounds in complex matrices.  相似文献   

14.
A general model of the transient behaviour of an oxygen probe is derived on more general assumptions than those previously considered. The present state of the art is shorly discussed in its relation to the newly derived equations: (1) the reducibility of the three-layer diffusional model to two-layer ones is discussed, and the two-layer model considering the membrane and the liquid film is verified experimentally, (2) experimental and theoretical treatments of transient probe characteristics determination are examined, and (3) the influence of chemical reactions of the first order as well as of zero order (microorgaganism respiration) in measured media on transientd probe characteristics is quantified.  相似文献   

15.
In this communication, we describe a novel and facile method for the immobilization of NAD(+)/NADH on an electrode surface using a hydrophobic ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C4mim][Tf(2)N]). By taking advantage of the insolubility of NAD(+)/NADH in hydrophobic ionic liquids, it is expected that NAD(+)/NADH can be retained on the electrode's surface. Alcohol dehydrogenase (ADH) and NAD(+)/NADH were immobilized with a gelatin hydrogel on an electrode that was modified with an electropolymerized ruthenium complex containing 5-amino-1,10-phenanthroline (pAPRu) as a mediator for NADH oxidation. The (ADH, NAD(+))/pAPRu-immobilized electrode exhibited the electrocatalytic oxidation of ethanol in [C4mim][Tf(2)N]. The obtained catalytic current in [C4mim][Tf(2)N] was comparable to that in buffer solution containing NAD(+). It was confirmed by UV-vis spectroscopy that NAD(+) did not dissolve in the [C4mim][Tf(2)N] and was retained on the electrode's surface. Furthermore, we succeeded in constructing an ethanol/O(2) biofuel cell comprised of an (ADH, NAD(+))/pAPRu anode and a bilirubin oxidase cathode using [C4mim][Tf(2)N] as an electrolyte.  相似文献   

16.
17.
18.
To investigate the time sequence of cardiac growth factor formation, echocardiographic and hemodynamic measurements were performed at scheduled times, and mRNAs for angiotensinogen, prepro-endothelin-1 (ppET-1), and insulin-like growth factor I (IGF-I) were quantified with RT-PCR and localized with in situ hybridization in pigs (fluothane anesthesia) by use of pressure or volume overload (aortic banding and aorta-cava fistula, respectively). Relative peptide formation was also measured by radioimmunoassay. In pressure overload, angiotensinogen and ppET-1 mRNA overexpression on myocytes (13 times vs. sham at 3 h and 112 times at 6 h, respectively) was followed by recovery (12 h) of initially decreased (0.5-6 h) myocardial contractility. In volume overload, contractility was not decreased, the angiotensinogen gene was slightly upregulated at 6 h (6.7 times), and ppET-1 was not overexpressed. IGF-I mRNA was overexpressed on myocytes (at 24 h) in both volume and pressure overload (14 times and 37 times, respectively). In the latter setting, a second ppET-1 overexpression was detectable on myocytes at 7 days. In conclusion, acute cardiac adaptation responses involve different growth factor activation over time in pressure versus volume overload; growth factors initially support myocardial contractility and thereafter induce myocardial hypertrophy.  相似文献   

19.
Left ventricular (LV) adrenomedullin (AM) gene expression differs between pressure overload (POL) and volume overload (VOL) and angiotensin II could be a critical stimulator of AM gene expression in POL and VOL models. Calcitonin receptor-like receptor (CRLR) co-expressed with receptor activity modifying protein 2 (RAMP2) or RAMP3 functions as an AM receptor. Levels of CRLR, RAMP2 and RAMP3 mRNA that were significantly increased within 24 h returned to the basal level at 5 days after the imposition of POL in the present study. In contrast, mRNA levels of CRLR and RAMP2 gradually increased over 6 weeks after the imposition of VOL. Continuous infusion of angiotensin II stimulated LV AM gene and AM receptor gene expression independently of LV peak-systolic and LV end-diastolic pressure. The gene expression of LV AM receptors increased in different types of cardiac overload. The present study revealed an intimate association between the AM signaling system and angiotensin II.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号