首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple procedure for the measurement of cortisol and 11-deoxycortisol in plasma or serum is described. One-half ml. of plasma is extracted with methylene chloride. Separation of cortisol and deoxycortisol is achieved by a Sephadex LH-20 mini-column. The assay itself is achieved by the use of a commercially available cortisol kit employing rabbit anti-cortisol coated tubes. This antibody exhibits a 20% crossreactivity with 11-deoxycortisol. This procedure is extremely useful in the assessment of a pituitary-adrenal reserve in the Metyrapone test.  相似文献   

2.
A radioimmunoassay for the measurement of 11-deoxycortisol in plasma is described. Antiserum against 11-deoxycortisol was produced by immunizing rabbits with the 21-hemisuccinate of 11-deoxycortisol coupled to bovine serum albumin. The method does not require chromatography but instead makes use of a simple extraction procedure which, in combination with the antibody characteristics, is relatively specific for the 11-deoxycortisol determination. The smallest amount measurable is 5 pg. The intra-assay coefficient of variation was 6.3% before metopirone and 7.2% after metopirone. The inter-assay coefficient of variation was 12.5% before metopirone and 10.3% after metopirone. Pituitary-adrenal reserve was evaluated in control and hypopituitary subjects by a simple midnight metopirone test.  相似文献   

3.
J G Lewis  K H Yeo  P A Elder 《Steroids》1986,47(6):365-372
An enzyme-linked immunosorbent assay (ELISA) for 11-deoxycortisol is described for the first time. 11-Deoxycortisol-thyroglobulin conjugate is adsorbed onto the wells of a 96-well ELISA plate and competes with 11-deoxycortisol in the standards or plasma extract for antibody binding sites. After washing, immobilized primary antibody is probed with peroxidase-labeled goat anti-rabbit IgG. The ELISA plate is further washed and o-phenylenediamine added, color developed and the absorbance read at 492 nm. The ELISA shows good agreement with our existing 11-deoxycortisol radioimmunoassay (RIA) and has similar specificity and performance which allow its use in the routine steroid laboratory for assessing pituitary adrenal function by the metyrapone test.  相似文献   

4.
Wudy SA  Hartmann M  Homoki J 《Steroids》2002,67(10):851-857
A first assay based on stable isotope dilution/gas chromatography-mass spectrometry (ID/GC-MS) has been developed for plasma 11-deoxycortisol (Reichstein's compound S), the leading hormonal marker of 11beta-hydroxylase deficiency. A suitable internal standard being unavailable, we synthesized dideuterated 11-deoxycortisol according to a newly devised synthetic procedure. 17,21-Dihydroxy-pregna-1,4-diene-3,20-dione underwent selective deuteration using Wilkinson's catalyst. Our product [1alpha,2alpha-2H2]11-deoxycortisol was obtained in good yield (35.6%) and high isotopic purity (0.1% 2H0, 99.9% 2H2). Structural confirmation was done by MS and NMR. Our plasma work up consisted of equilibration of plasma with internal standard ([1alpha,2alpha-2H2]11-deoxycortisol), solid phase extraction with Extrelut NT columns, a clean up step using Sephadex LH-20 mini columns and preparation of heptafluorobutyrates as derivatives. Quantification was achieved by selected ion monitoring of m/z 465.40 (analyte) and m/z 467.40 (internal standard). One hundred twenty picograms of 11-deoxycortisol gave a signal to noise ratio of 10. Calibration plot was linear. Spiking experiments showed good accuracy with relative errors <3.0%. Intraassay precision CV was 4.78% and interassay precision CV was 4.56%. We succeeded in integrating our new analyte into our already existing multisteroid ID/GC-MS plasma assay, which now, in its expanded version, is capable of determining all major diagnostic steroids of androgen related disorders in a single profile: 11-deoxycortisol, 17alpha-hydroxyprogesterone, testosterone, 4-androstenedione, 17alpha-hydroxypregnenolone, dehydroepiandrosterone, androstanediol and 5alpha-dihydrotestosterone. The diagnostic potential of our multisteroid ID/GC-MS assay, the small amounts of plasma (0.5 ml) required, the rapid and convenient sample work up, the application of benchtop GC-MS instrumentation, and highest specificity offered by mass spectrometric detection prove our assay suitable for routine clinical use, especially in pediatric endocrinology.  相似文献   

5.
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.  相似文献   

6.
Affinity chromatography of glucocorticoid antisera using cross-reacting steroid-Sepharose columns and competitive elution with the immunising steroid has allowed the separation of polyclonal antibodies into fractions of varying cross-reactivity. Elution was at neutral pH in the presence of 20% acetonitrile followed by dissociation of the eluted immunoglobulin-steroid complex, by dialysis. A polyclonal cortisol antibody with an initial 70% cross-reactivity to 11-deoxycortisol yielded a fraction with 10% cross reactivity and improved affinity. This fraction was suitable for determining plasma cortisol on patients undergoing the metyrapone test whereas another fraction of similar affinity but higher cross reactivity to 11-deoxycortisol, as well as the intact antiserum, grossly over-estimated plasma cortisol on these patients. This technique should permit the use of antibody fractions for immunoassay when the intact antiserum may be unsatisfactory due to lack of specificity.  相似文献   

7.
A microbial fluctuation test, modified for the detection of environmental mutagens has been evaluated using a number of strains of the yeast Saccharomyces cerevisiae. Auxotrophic diploid cultures of yeast which produce prototrophic colonies by both mitotic gene conversion and mutation have been extensively utilized for the detection and evaluation of chemicals showing genetic activity. A number of the yeast strains utilized were shown to be suitable for use in the fluctuation test although the time scales of the experiments were considerably extended (up to 16 days) compared to those involving bacteria. The yeast strains respond to doses of mutagens at least a 100-fold lower than that required in a conventional short exposure treat and plate experiment. In experiments involving the induction of mitotic gene conversion at the tryptophan-5 and histidine-4 loci in the fluctuation test significant increases in prototrophic cells were produced in the presence of the insecticide Lindex (0.05 microng/ml), the preservative Thiomersal (0.0001 microng/ml), a mahogany hair dye (0.01 microng/ml), the herbicide Paraquat (0.02 microng/ml) and the alkylating agent ethyl methane sulphonate (0.1 microng/ml). The results demonstrate that the fluctuation test provides an extremely sensitive assay for the detection of chemicals which show genetic activity in yeast at non-toxic concentrations.  相似文献   

8.
Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500) nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program.  相似文献   

9.
A rapid and sensitive high performance liquid chromatography (HPLC) method with fluorescence detection has been developed for the determination of sumatriptan in human plasma. The procedure involved a liquid-liquid extraction of sumatriptan and terazosin (internal standard) from human plasma with ethyl acetate. Chromatography was performed by isocratic reverse phase separation on a C18 column. Fluorescence detection was achieved with an excitation wavelength of 225 nm and an emission wavelength of 350 nm. The standard curve was linear over a working range of 1-100 ng/ml and gave an average correlation coefficient of 0.9997 during validation. The limit of quantitation (LOQ) of this method was 1 ng/ml. The absolute recovery was 92.6% for sumatriptan and 95.6% for the internal standard. The inter-day and intra-day precision and accuracy were between 0.8-3.3 and 1.1-6.3%, respectively. This method is simple, sensitive and suitable for pharmacokinetics or bioequivalence studies.  相似文献   

10.
A simple, rapid and sensitive method for determination of rivastigmine in plasma samples was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography with mass spectrometry (GC-MS). The optimum conditions for the SPME procedure were: headspace extraction on a 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber; 0.5 ml of plasma modified with 1.0 ml of sodium hydroxide-sodium carbonate solution (0.7 M:0.5M); extraction temperature of 100 degrees C, with stirring at 2000 rpm for 30 min. The calibration curve showed linearity in the range from 0.2 to 80 ng/ml with regression coefficient corresponding to 0.9965 and coefficient of the variation of the points of the calibration curve lower than 10%. The quantification limit for rivastigmine in plasma was 0.2 ng/ml. The method was applied to determination of rivastigmine in canine plasma samples from animals after a single oral administration.  相似文献   

11.
The influence of ACTH fragments, possessing structural elements, common for certain groups of peptide hormones and kinins--"common" fragments and cluster of basic amino-acids--(Lys 17,18-ACTH 11-18-NH2--I; ACTH 11-13-NH2--II; NH2CO-ACTH18-20-NH2--III) on lipolytic effect of ACTH in rat isolated fat cells and on the steroidogenic effect of ACTH in isolated rat adrenal cells was studied. Fragment I exerts a steroidogenic effect (alpha=0,84) at concentrations of 1--100 microng/ml. At low concentrations (10(-8)--10(-3) microng/ml) fragment I potentiates ACTH-induced steroidogenesis. Fragment I has no effect on the lipolysis;however, it potentiates ACTH-induced lipolysis at concentrations of 10--100 microng/ml. The results obtained support our previous supposition that "common" fragments are essential secondary non-specific active sites of hormones.  相似文献   

12.
A radial diffusion assay for tissue collagenase (EC 3.4.24.3) has been devised which is simple, sensitive and capable of application to large numbers of samples. The assay employs an agarose matrix containing solubilized lathyritic rat skin collagen as substrate. Fibril formation is induced for 2 h at 37 degrees C subsequent to 41 h digestion at 28 degrees C. The procedure results in sharply defined zones of lysis which may be measured directly or after photography. The characteristics of the procedure are otherwise similar to those reported for other radial diffusion assays. The new method was used to examine the action of 10 compounds which were known or potential inhibitors of tadpole collagenase. The concentration of inhibitor required to produce 50% inhibition is reported for the following compounds: alpha2-macroglobulin, 142 microng/ml; N-acetylcysteine, greater than or equal to 100 mM; cysteine, 8.7 mM; EDTA, 0.46 mM; histidine, greater than or equal to 100 mM; 2,3-dimercaptopropanol, 0.5 mM and mercaptoacetic acid, 70 mM. The procedure also has potential for clinical determinations (e.g. tears, synovial fluid) since assay dishes may be prepared in advance and only 15 micronl of sample is required.  相似文献   

13.
Irinotecan (CPT-11) is an anticancer agent widely employed in the treatment of colorectal carcinoma. A simple, rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of CPT-11 and its metabolite SN-38 in plasma, and their preliminary clinical pharmacokinetics are described. Both deproteinisation of plasma specimens (100 μl) and addition of the internal standard, camptothecin (CPT), are achieved by incorporating to samples 100 μl of a solution of CPT (1 μg/ml) in acetonitrile–1 mM orthophosphoric acid (90:10); 200 μl of this acidified acetonitrile solution, drug-free, is also added to accomplish complete deproteinisation: this procedure reduces sample preparation time to a minimum. After deproteinisation, samples are treated with potassium dihydrogenphosphate (0.1 M) and injected into a Nucleosil C18 (5 μm, 250×4.0 mm) column. Mobile phase consists of potassium dihydrogenphosphate (0.1 M)–acetonitrile (67:33), at a flow-rate of 1 ml/min. CPT-11, SN-38 and CPT are detected by fluorescence with excitation wavelength set at 228 nm and emission wavelengths of CPT-11, SN-38 and CPT fixed, respectively, at 450, 543 and 433 nm. The limits of quantitation for CPT-11 and SN-38 are 1.0 and 0.5 ng/ml, respectively. This method shows good precision: the within day relative standard deviation (RSD) for CPT-11 (1–10 000 ng/ml) is 5.17% (range 2.15–8.27%) and for SN-38 (0.5–400 ng/ml) is 4.33% (1.32–7.78%); the between-day RSDs for CPT-11 and SN-38, in the previously described ranges, are 6.82% (5.03–10.8%) and 4.94% (2.09–9.30%), respectively. Using this assay, plasma pharmacokinetics of CPT-11, SN-38 and its glucuronidated form, SN-38G, have been determined in one patient receiving 200 mg/m2 of CPT-11 as a 90 min intravenous infusion. The peak plasma concentration of CPT-11 at the end of the infusion is 3800 ng/ml. Plasma decay is biphasic with a terminal half-life of 11.6 h. The volume of distribution at steady state (Vss) is 203 l/m2, and the total body clearance (Cl) is 14.8 l/h·m2. The maximum concentrations of SN-38 and SN-38G reach 28.9 and 151 ng/ml, respectively.  相似文献   

14.
The development and validation of a direct injection high-performance liquid chromatographic (HPLC) method, with column switching, for the determination of metyrapol enantiomers and metyrapone in human plasma is described. The system used in this work was composed of a restricted access media (RAM) bovine serum albumin (BSA) octyl column coupled to an amylose tris(3,5-dimethoxyphenylcarbamate) chiral column. Water was used as eluent for the first 5 min at a flow rate of 1.0 ml/min for the elution of the plasma proteins and then acetonitrile-water (30:70 v/v) for the transfer and analysis of metyrapol enantiomers and metyrapone, which were detected by UV at lambda = 260 nm. The total analysis time was about 32 min. The calibration curves for each enantiomer and for the metyrapone were linear in the ranges 0.075-0.75 microg/ml and 0.150-1.50 microg/ml, respectively. Recoveries, intra- and interday precision and accuracy were determined using three quality controls, one low (0.18 microg/ml), one medium (0.75 microg/ml), and one high (1.35 microg/ml) plasma concentration. Quantitative recoveries and good precision and accuracy were obtained. The limit of quantitation were 0.045 microg/ml for both enantiomers and for the metyrapone.  相似文献   

15.
Fat mobilyzing activity of synthetic tetradecapeptide, which corresponds in 31--44 amino acid sequence of human growth hormone, is studied in vitro in human fat tissue. The peptide at concentrations of 3--33 microng/ml considerably stimulated lipolysis in subdermal fat tissue, omentum and shoulder ateroma. Minimal efficient peptide concentration was 3 microng/ml in most experiments, sometimes it was 0.3 microng/ml. Direct dependency between dose logarithm and lipolysis rate was observed at dose interval of 0.3--18 microng/ml. Native growth hormone produced no activity in human fat tissue even in concentrations of 50--100 microng/ml.  相似文献   

16.
We describe a sensitive specific and simple high pressure liquid chromatographic procedure for determining 3,4-dihydroxyphenylethylene glycol (DHPG) in both plasma and tissue. DHPG is extracted from plasma or tissue extracts by adsorption onto alumina. DHPG in the alumina eluate is detected electrochemically following chromatography on a C18 reverse phase column. The method is sensitive enough to detect approximately 20 pg/ml of plasma DHPG. Both clonidine (100 μg/kg) and desmethylimipramine (2.5 mg/kg) when administered to rabbits for 3 days induced significant falls in both cardiac and plasma DHPG concentrations. These experiments indicate that both tissue and plasma DHPG concentrations may be of value in assessing both the release and re-uptake of norepinephrine at peripheral sympathetic nerve endings in vivo.  相似文献   

17.
A biotinylated 11-deoxycortisol tracer was synthesized from 11-deoxycortisol-3-carboxymethyloxime and the conjugate obtained by acylation of biotinylaminopropylammonium trifluoroacetate. This biotinylated tracer was used to develop an 11-deoxycortisol time-resolved-fluoroimmunoassay (TR-FIA). The tracer was quantified after adding streptavidine-Europium. A TR-FIA sensitive standard curve, with displacement of 20, 50, and 80% of tracer was obtained with 12.4, 70.7, and 512.8 pg of 11-deoxycortisol, respectively. After extraction followed by Celite chromatography, purified serum samples were simultaneously assayed by RIA and TR-FIA. The results obtained by the two methods were practically identical, however, this new specific, non-isotopic 11-deoxycortisol assay has the advantage of being more sensitive than RIA, thus well-suited to accurate measurement in endocrinological studies, particularly when serum 11-deoxycortisol levels in patients are just above the highest normal values. Moreover, this non-isotopic assay is cheaper than RIA.  相似文献   

18.
A simple and sensitive procedure for the quantitative estimation of Triton X-100 is described. The method is based on the formation of turbidity from Triton X-100 with phenol. The turbidity is proportional to Triton X-100 in a range of 20–80 μg/ml. Protein, mucopolysaccharide, and nucleic acid do not interfere in this turbidity formation. The method is especially useful for detection of the residue after the removal of Triton X-100 from solubilized samples.  相似文献   

19.
A rapid, selective, sensitive and reproducible HPLC–electrospray tandem mass spectrometric method has been developed for the analysis of novel triazole antifungal agents, SYN-2869 and its derivatives (SYN-2836, SYN-2903 and SYN-2921), in rat plasma using SYN-2506 as an internal standard. Isolation of these compounds from plasma and sample desalting were performed by a simple extraction procedure involving protein precipitation, vacuum-drying and reconstitution with acetonitrile. For all the agents, linearity was observed over the range of 10–10 000 ng/ml (r≥0.996) and the limit of quantitation was 10 ng/ml using a 100-μl plasma volume. A measurement rate of 400–500 samples/day/instrument could be achieved using this method.  相似文献   

20.
A high-performance liquid chromatographic method for the determination of disodium dihydrogen(cycloheptylamino)methylenebisphosphonate monohydrate (YM175) in plasma, urine and bone is described. Plasma obtained in high-dose animal studies is pretreated by Method A, a simple method using 1 ml of plasma, which is based on deproteinization of plasma followed by coprecipitation of the drug with calcium phosphate and removal of excess calcium ions by AG 50W-X8 resin. Plasma obtained in lower-dose clinical studies is treated by Method B, a more sensitive method using 10 ml of plasma, which is based on solid-phase extraction using a Sep-Pak C18 cartridge coupled with Method A. Urine and bone are treated similarly to Method B. The chromatographic system consists of a mobile phase at pH 11, an alkali-stable column and an electrochemical detector operating in the oxidation mode. The determination limit is 5 ng/ml for Method A and 0.5 ng/ml for Method B in plasma, 1 ng/ml in urine, and 25 ng/g in bone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏