首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A robust high-throughput single-nucleotide polymorphism (SNP) genotyping method is reported, which applies allele-specific extension to achieve allelic discrimination and uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to measure the natural molecular weight difference of oligonucleotides for determination of the base in a single-nucleotide polymorphic location. Tenfold PCR is performed successfully by carefully designing the primers and adjusting the conditions of PCR. In addition, two ways used for PCR product purification are compared and the matrix used in mass spectrometry for high-throughput oligonucleotide analysis is evaluated. The result here shows that the method is very effective and suitable for high-throughput genotyping of SNPs.  相似文献   

3.
与传统的微生物鉴定技术相比,基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry, MALDI-TOF MS)是一种准确、可靠和快速的鉴定和分型的技术。本文通过检索近年来国内外相关研究论文,总结最新的研究进展,发现MALDI-TOF MS在临床病原微生物、食源性微生物以及环境微生物等鉴定中有较大的优势,加快了微生物鉴定的进程,同时探索该技术在新领域的最新进展和面临的挑战,以期为我国基质辅助激光解吸电离飞行时间质谱技术的发展提供参考。  相似文献   

4.
To evaluate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) as a tool for rapid identification of common clinical bacterial isolates, we analyzed 25 carefully selected isolates of pathogenic Escherichia coli (E. coli) and additional Enterobacteriaceae members. Organisms were prepared according to clinical microbiological protocols and analyzed with minimal additional processing. Spectra were reproducible from preparation to preparation and comprised 40-100 peaks primarily representing intracellular proteins with masses up to 25 kDa. Spectra of 14 genetically diverse bacteremic isolates of E. coli were compared with isolates representing other genera within the Enterobacteriaceae family. Using a new spectrum comparison algorithm, E. coli isolates were closely related to each other and were readily distinguishable from other Enterobacteriaceae, including Salmonella and Shigella. Presently, the methodology permits the analysis of 40 unknown isolates per hour per instrument. These results suggest that MALDI-ToF MS offers a rapid and reliable approach for performing phyloproteomics i.e., identification of unknown bacterial isolates based on similarities within protein biomarker databases.  相似文献   

5.

Background

MALDI-TOF MS recently emerged as a valuable identification tool for bacteria and yeasts and revolutionized the daily clinical laboratory routine. But it has not been established for routine mould identification. This study aimed to validate a standardized procedure for MALDI-TOF MS-based mould identification in clinical laboratory.

Materials and Methods

First, pre-extraction and extraction procedures were optimized. With this standardized procedure, a 143 mould strains reference spectra library was built. Then, the mould isolates cultured from sequential clinical samples were prospectively subjected to this MALDI-TOF MS based-identification assay. MALDI-TOF MS-based identification was considered correct if it was concordant with the phenotypic identification; otherwise, the gold standard was DNA sequence comparison-based identification.

Results

The optimized procedure comprised a culture on sabouraud-gentamicin-chloramphenicol agar followed by a chemical extraction of the fungal colonies with formic acid and acetonitril. The identification was done using a reference database built with references from at least four culture replicates. For five months, 197 clinical isolates were analyzed; 20 were excluded because they were not identified at the species level. MALDI-TOF MS-based approach correctly identified 87% (154/177) of the isolates analyzed in a routine clinical laboratory activity. It failed in 12% (21/177), whose species were not represented in the reference library. MALDI-TOF MS-based identification was correct in 154 out of the remaining 156 isolates. One Beauveria bassiana was not identified and one Rhizopus oryzae was misidentified as Mucor circinelloides.

Conclusions

This work''s seminal finding is that a standardized procedure can also be used for MALDI-TOF MS-based identification of a wide array of clinically relevant mould species. It thus makes it possible to identify moulds in the routine clinical laboratory setting and opens new avenues for the development of an integrated MALDI-TOF MS-based solution for the identification of any clinically relevant microorganism.  相似文献   

6.
7.
The DNA of all organisms is persistently damaged by endogenous reactive molecules. Most of the single-base endogenous damage is repaired through the base excision repair (BER) pathway that is initiated by members of the DNA glycosylase family. Although the BER pathway is often considered to proceed through a common abasic site intermediate, emerging evidence indicates that there are likely distinct branches reflected by the multitude of chemically different 3′ and 5′ ends generated at the repair site. In this study, we have applied matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF–MS) to the analysis of model DNA substrates acted on by recombinant glycosylases. We examine the chemical identity of several possible abasic site and nicked intermediates generated by monofunctional and bifunctional glycosylases. Our results suggest that the intermediate from endoIII/Nth might not be a simple β-elimination product as described previously. On the basis of 18O incorporation experiments, we propose a new mechanism for the endoIII/Nth family of glycosylases that may resolve several of the previous controversies. We further demonstrate that the use of an array of lesion-containing oligonucleotides can be used to rapidly examine the substrate preferences of a given glycosylase. Some of the lesions examined here can be acted on by more than one glycosylase, resulting in a spectrum of damaged intermediates for each lesion, suggesting that the sequence and coordination of repair activities that act on these lesions may influence the biological outcome of damage repair.  相似文献   

8.
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive.  相似文献   

9.
A method is described for the quantitative determination of peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Known limitations imposed by crystal heterogeneity, peptide ionization differences, data handling, and protein quantification with MALDI-TOF mass spectrometry are addressed in this method with a "seed crystal" protocol for analyte-matrix formation, the use of internal protein standards, and a software package called maldi_quant. The seed crystal protocol, a new variation of the fast-evaporation method, minimizes crystal heterogeneity and allows for consistent collection of protein spectra. The software maldi_quant permits rapid and automated analysis of peak intensity data, normalization of peak intensities to internal standards, and peak intensity deconvolution and estimation for vicinal peaks. Using insulin proteins in a background of other unrelated peptides, this method shows an overall coefficient of variance of 4.4%, and a quantitative working range of 0.58-37.5 ng bovine insulin per spot. Coupling of this methodology to powerful analytical procedures such as immunoprecipitation is likely to lead to the rapid and reliable quantification of biologically relevant proteins and their closely related variants.  相似文献   

10.
The aim of this study was to discriminate 30 Vibrio strains isolated from two wastewater treatment plants from Agadir, Morocco by two molecular typing methods, pulsed-field gel electrophoresis (PFGE) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Out of the 30 strains of Vibrio examined in this study, 5 isolates could not be typed by PFGE and consistently appeared as a smear on the gel. In general, high genetic biodiversity among the Vibrio strains was found regardless to the isolation source. The results of MALDI TOF analysis show a high congruence of strain grouping demonstrating the accuracy and reliability of MALDI-TOF MS.  相似文献   

11.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) serves as a rapid and accurate means to determine masses of proteins independent of their shapes or interactions with other molecules. It provides one of the most fundamental characterizations of major plasma proteins. Purified proteins in saline or serum specimens were prepared for analysis by dilution, mixing with a solution of sinapinic acid, and drying on a target plate. Specimens were analyzed in a linear TOF mode with external calibration. Analyses of 24 purified plasma proteins showed predominance of singly charged ions with lesser amounts of dimer and doubly charged monomer, and provided measured masses for these proteins. A number of proteins, including albumin, transferrin, apolipoproteins A-I, A-II, C-I, C-II, and C-III, and prealbumin, could be analyzed directly in serum with appropriate dilution. Measured values for masses of major plasma proteins will assist in analysis of serum and plasma. It is possible to analyze a number of components by MALDI-TOF/MS directly in diluted serum. Extremely simple sample preparation techniques may be useful in analyzing structural variation of several major plasma proteins, particularly those with masses <30 kDa, including a number of apolipoproteins and markers of nutritional status or acute phase responses.  相似文献   

12.
Three ultrasonic energy sources were studied to speed up the sample treatment for in-solution protein identification by peptide mass fingerprint using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Protein reduction, alkylation, and enzymatic digestion steps were done in 15 min. Nine proteins, including zinc resistance-associated protein precursor from Desulfovibrio desulfuricans strain G20 and split-soret cytochrome c from D. desulfuricans ATCC27774 were successfully identified with the new protocol.  相似文献   

13.
14.
A nonradioactive assay for protein tyrosine phosphatases (PTPs), employing a tyrosine-phosphorylated peptide as a substrate, has been developed and applied to analyze purified enzymes, cell extracts, and immunoprecipitates. The reaction was followed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) in a linear and positive ion mode with delayed extraction. MALDI-TOF MS detects a loss of peptide mass by 80 Da as a result of dephosphorylation and, more importantly, it yields phospho-peptide to dephosphorylated product peak intensity ratios proportional to their concentration ratios. A strong bias of the MALDI-TOF MS toward detection of the non-phospho-peptide allows accurate detection of small fractions of dephosphorylation. The method is highly sensitive and reproducible. It can be applied to general assays of protein phosphatases with various phospho-peptides as substrates.  相似文献   

15.
Histone lysine methyltransferases (HKMTs) are enzymes that play an essential role in epigenetic regulation. Thus, identification of inhibitors specifically targeting these enzymes represents a challenge for the development of new antitumor therapeutics. Several methods for measuring HKMT activity are already available. Most of them use indirect measurement of the enzymatic reaction through radioactive labeling or antibody-recognized products or coupled enzymatic assays. Mass spectrometry (MS) represents an interesting alternative approach because it allows direct detection and quantification of enzymatic reactions and can be used to determine kinetics and to screen small molecules as potential inhibitors. Application of mass spectrometry to the study of HKMTs has not been fully explored yet. We describe here the development of a simple reliable label-free MALDI-TOF MS-based assay for the detection and quantification of peptide methylation, using SET7/9 as a model enzyme. Importantly, the use of expensive internal standard often required in mass spectrometry quantitative analysis is not necessary in this assay. This MS assay allowed us to determine enzyme kinetic parameters as well as IC50 for a known inhibitor of this enzyme. Furthermore, a comparative study with an antibody-based immunosorbent assay showed that the MS assay is more reliable and suitable for the screening of inhibitors.  相似文献   

16.

Background

MALDI-TOF mass spectrometry is currently used in microbiological diagnosis to characterize bacterial populations. Our aim was to determine whether this technique could be applied to intact eukaryotic cells, and in particular, to cells involved in the immune response.

Methodology/Principal Findings

A comparison of frozen monocytes, T lymphocytes and polymorphonuclear leukocytes revealed specific peak profiles. We also found that twenty cell types had specific profiles, permitting the establishment of a cell database. The circulating immune cells, namely monocytes, T lymphocytes and polymorphonuclear cells, were distinct from tissue immune cells such as monocyte-derived macrophages and dendritic cells. In addition, MALDI-TOF mass spectrometry was valuable to easily identify the signatures of monocytes and T lymphocytes in peripheral mononuclear cells.

Conclusions/Significance

This method was rapid and easy to perform, and unlike flow cytometry, it did not require any additional components such as specific antibodies. The MALDI-TOF mass spectrometry approach could be extended to analyze the cell composition of tissues and the activation state of immune cells.  相似文献   

17.
Many cancers are characterized by changes in protein phosphorylation as a result of kinase dysregulation. Disruption of Abl kinase signaling through the Philadelphia chromosome (causing the Bcr-Abl mutation) in chronic myeloid leukemia (CML) has provided a paradigm for development of kinase inhibitor drugs such as the specific inhibitor imatinib (also known as STI571 or Gleevec). However, because patients are treated indefinitely with this drug to maintain remission, resistance is increasingly becoming an issue. Although there are many ways to detect kinase activity, most lack the ability to “multiplex” the analysis (i.e., to detect more than one substrate simultaneously). Here we report a novel biosensor for detecting Abl kinase activity and sensitivity to inhibitor in live intact cells overexpressing a CML model Abl kinase construct. This straightforward methodology could eventually provide a new tool for detecting kinase activity and inhibitor drug response in cancer cells that overexpress oncogenic kinases.  相似文献   

18.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been used for many years to rapidly identify whole bacteria. However, no consistent methodology exists for the rapid identification of bacteria cultured in liquid media. Thus, in this study we explored the use of MALDI-TOF MS analysis for rapid identification of cells cultured in liquid media. We determined that 2,5-dihydroxybenzoic acid (50 mg mL?1, 50% acetonitrile, 0.1% trifluoroacetic acid) was the best matrix solution for MALDI-TOF MS for this type of study. Moreover, the tested strains were successfully differentiated by principal component analysis, and the main characteristics of the mass peaks for each species were found in mixed culture samples. In addition, we found that the minimum number of cells for detection was 1.8×103. In conclusion, our findings suggest that MS-based techniques can be developed as an auxiliary method for rapidly and accurately identifying bacteria cultured in liquid media.  相似文献   

19.
Ricin, the toxin component of Ricinus communis is considered as a potential chemical weapon. Several complementary techniques are required to confirm its presence in environmental samples. Here, we report a method combining immunocapture and analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the accurate detection of different species of R. communis. Liquid environmental samples were applied to magnetic particles coated with a monoclonal antibody directed against the B-chain of the toxin. After acidic elution, tryptic peptides of the A- and B-chains were obtained by accelerated digestion with trypsin in the presence of acetonitrile. Of the 20 peptides observed by MALDI-TOF MS, three were chosen for detection ( m/ z 1013.6, m/ z 1310.6 and m/ z 1728.9, which correspond to peptides 161-LEQLAGNLR-169, 150-YTFAFGGNYDR-160, and 233-SAPDPSVITLENSWGR-248, respectively). Their selection was based on several parameters such as detection sensitivity, specificity toward ricin forms and absence of isotopic overlap with unrelated peptides. To increase assay reproducibility, stable isotope-labeled peptides were incorporated during the sample preparation phase. The final assay has a limit of detection estimated at approximately 50 ng/mL ( approximately 0.8 nM) of ricin in buffer. No interference was observed when the assay was applied to ricin-spiked milk samples. In addition, several varieties of R. communis or from different geographical origins were also shown to be detectable. The present assay provides a new tool with a total analytical time of approximately 5 h, which is particularly relevant in the context of a bioterrorist incident.  相似文献   

20.
Cartilage extracellular matrix molecules synthesized and maintained by chondrocytes form a strong, elastic tissue functioning to cushion and protect the subchondral bone. Osteoarthritis is characterized by degradation of cartilage extracellular matrix molecules resulting in fibrillation, irreversible erosion, and eventual failure of the tissue. With recent interest in the degradation of cartilage extracellular matrix molecules, a need for more detailed structural information exists. Posttranslational modifications are believed to play a role in determining the susceptibility of these molecules to proteolytic degradation during the development of osteoarthritis. The purpose of this paper is to show how the application of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry to extracellular matrix protein and proteoglycan structure will help elucidate problems in extracellular matrix biochemistry. Methodological issues relating to the high molecular weight, polydispersity, and high degree of posttranslational modification of these molecules are discussed. MALDI-TOF mass spectrometry provides an improved level of detail for extracellular matrix protein and proteoglycan structure and is useful in addressing issues surrounding the causes of degradation during osteoarthritis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号