首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study demonstrates the increased versatility of the Chiralcel OJ-H stationary phase when using various alcohol/acetonitrile mobile phases. This chiral stationary phase has traditionally been employed in the normal phase mode and more recently with neat alcohols as eluents. Selected isomeric human mineralocorticoid receptor (hMR) antagonist pharmaceutical candidates and synthetic intermediates were separated using the Chiralcel OJ-H HPLC column with novel polar cosolvent eluent systems. The capacity factors, resolution, and selectivity of the chiral separations were assessed while varying the alcohol/acetonitrile composition and alcohol identity. The mixed polar eluents provide separations that are nearly always superior to both the traditional hexane-rich and single-alcohol "polar organic" eluents for the compounds tested in this article.  相似文献   

2.
Analytical HPLC methods using carbamate chiral stationary phases of polysaccharide derivatives were developed for the enantiomeric resolution of five racemic mixtures of xanthonolignoids: rac-trans-kielcorin C, rac-cis-kielcorin C, rac-trans-kielcorin D, rac-trans-isokielcorin D, and rac-trans-kielcorin E. The separations were evaluated with the stationary phases cellulose tris-3,5-dimethylphenylcarbamate, amylose tris-3,5-dimethylphenylcarbamate, amylose tris-(S)-1-phenylethylcarbamate, and amylose tris-3,5-dimethoxyphenylcarbamate under normal, reversed-phase, and polar organic elution conditions. Chiral recognition of those chiral stationary phases, the influence of mobile phases on the enantiomers separation, and the effects of structural features of the solutes on the chiral discrimination observed are discussed. The best performance was achieved on an amylose tris-3,5-dimethylphenylcarbamate phase. Polar organic conditions gave shorter retention factors and better resolutions and were a valuable alternative to the alcohol-hexane or reversed-phase conditions.  相似文献   

3.
The enantiomeric separation of 21 ruthenium (II) polypyridyl complexes was achieved with a novel class of cyclofructan‐based chiral stationary phases (CSPs) in the polar organic mode. Aromatic derivatives on the chiral selectors proved to be essential for enantioselectivity. The R‐napthylethyl carbamate functionalized cyclofructan 6 (LARIHC CF6‐RN) column proved to be the most effective overall, while the dimethylphenyl carbamate cyclofructan 7 (LARIHC CF7‐DMP) showed complementary selectivity. A combination of acid and base additives was necessary for optimal separations. The retention factor vs. acetonitrile/methanol ratio plot showed a U‐shaped retention curve, indicating that different interactions take place at different polar organic solvent compositions. The separation results indicated that π–π interactions, steric effects, and hydrogen bonding contribute to the enantiomeric separation of ruthenium (II) polypyridyl complexes with cyclofructan chiral stationary phases in the polar organic mode. Chirality 27:64–70, 2015. © 2014 Wiley Periodicals, Inc.  相似文献   

4.
Oligosaccharide separation on reversed-phase high-performance liquid chormatographic columns have been examined using a range of aqueous solvents. Addition of anionic, cationic and non-ionic surfactants, tetramethyl urea and organic solvents to the mobile phase cause faster elution of oligosaccharides, and allow the separation of the larger oligomers in an acceptable time. Addition of neutral, inorganic salts increase the retention factors considerably, and allows good resolution of some compounds poorly resolved in water alone.The mechanism operating in the separations approximates to that invoked in the solvophobic theory of reversed-phase chromatography. There is some evidence also of hydrogen bond effects. The improvements described should prove useful in the isolation and analysis of neutral oligosaccharides in general, and in structural analyses of polysaccharides in paritcular.  相似文献   

5.
Use of silica stationary phase and aqueous–organic mobile phases could significantly enhance LC–MS–MS method sensitivity. The LC conditions were compatible with MS detection. Analytes with basic functional groups were eluted with acidic mobile phases and detected by MS in the positive ion mode. Analytes with acid functional groups were eluted with mobile phases at neutral pH and detected by MS in the negative ion mode. Analytes poorly retained on reversed-phase columns showed good retention on silica columns. Compared with reversed-phase LC–MS–MS, 5–8-fold sensitivity increases were observed for basic polar ionic compounds when using silica columns and aqueous–organic mobile phase. Up to a 20-fold sensitivity increase was observed for acidic polar ionic compounds. Silica columns and aqueous–organic mobile phases were used for assaying nicotine, cotinine, and albuterol in biological fluids.  相似文献   

6.
Rao RN  Kumar KN  Naidu CG 《Chirality》2012,24(8):652-660
Liquid chromatographic separation of darunavir enantiomers on covalently bonded and physically adsorbed polysaccharide chiral stationary phases was studied at different temperatures. The separations were accomplished under normal-phase conditions by using different combinations of hexane, organic modifiers (2-propanol, 1-propanol and ethanol), and diethylamine as mobile phase solvents. The effect of organic modifiers and the column temperature on retention, separation, and resolution was investigated. The observed differences were explained in terms of the coated and immobilized nature of the two columns. Van't Hoff plots (ln k' vs. 1/T, ln α vs. 1/T) and apparent thermodynamic parameters were derived to understand the effect of temperature on separation.  相似文献   

7.
Patti A  Pedotti S  Sanfilippo C 《Chirality》2007,19(5):344-351
The direct HPLC enantiomeric separation of several ferrocenylalcohols on the commercially available Chiralcel OD and Chiralcel OJ columns has been evaluated in normal-phase mode. Almost all the compounds were resolved on one or both chiral stationary phases (CSPs) with separation factor (alpha) ranging from 1.06 to 2.88 while the resolution (R(s)) varied from 0.63 to 12.70 In the separation of the alpha-ferrocenylalcohols 1a-e and the phenyl analogues 2a-e, which were all resolved except 1c, a similar trend in the retention behavior for the two series of alcohols was evidenced and the selectivity was roughly complementary on the two investigated CSP. For three ferrocenylacohols, chosen as model compounds, the influence of the mobile phase composition and temperature on the enantioseparation were investigated and additional information on the chiral recognition mechanism were deduced from the chromatographic behavior of their acetylderivatives.  相似文献   

8.
Vancomycin immobilized on silica served as the chiral stationary phase (CSP) in this investigation with polar organic solvents as the mobile phase in liquid chromatography (LC). It was shown that trace amounts of water were beneficial for improving peak shape and efficiency. To regulate the retention and selectivity an acid and/or base were added to the mobile phase where an excess of acid was shown to be preferential for enantioseparation. An unusual increase in selectivity with increasing temperature was shown for the acidic drug, thalidomide. Additionally, nonlinear van't Hoff plots were obtained for metoprolol enantiomers that showed increased retention with increasing temperature. Metoprolol also showed unusual behavior in the polar organic phase when water was added to resemble reversed-phase chromatography, with minimum retention observed at high water or high methanol concentrations. In both instances a high degree of electrostatic interaction between metoprolol and vancomycin was concluded. Metoprolol and ten of its analogs were examined on this CSP to evaluate the enantiorecognition process. A comparison in enantioselectivity for a number of acidic and basic drugs using this CSP was also carried out using the polar organic phase, reversed phase, and normal phase LC which were all compared to the results obtained in supercritical fluid chromatography (SFC). Polar organic phase LC offered a better separation of basic molecules while reversed phase LC was preferred for the resolution of acids. SFC showed the broadest enantioselectivity overall and normal phase LC indicated similar properties, as expected, to SFC but with lower column efficiency. Copyright 2000 Wiley-Liss, Inc.  相似文献   

9.
P M Young  T E Wheat 《BioTechniques》1991,10(2):228-235
The standard method for separating peptide mixtures is reversed-phase high-performance liquid chromatography with gradients of increasing concentrations of acetonitrile in the presence of trifluoroacetic acid. With modern instruments and columns, complex peptide mixtures can be separated, and low picomole amounts can be collected in tens of microliters. Difficult separations are addressed by modifying the gradient slope or organic eluant composition. Further improvements in resolution are often needed, requiring fundamental changes in mobile phase composition or selection of complementary chromatographic separation mechanisms. For the present study, tryptic digests of cytochrome c from various species were separated in the presence of dilute hydrochloric acid by reversed phase on a Waters Delta-PakTM C18 high-performance insert column and by strong cation exchange on a Waters Protein-PakTM SP 8HR. Different and enhanced reversed-phase selectivity was obtained by replacing trifluoroacetic acid with dilute hydrochloric acid at the same pH. The increased optical clarity of hydrochloric acid-based mobile phases in the low ultraviolet wavelengths yielded increased sensitivity. Very different selectivity was observed with the cation-exchange chromatography. These data expand the options for peptide mapping by providing additional selectivity combined with increased mass sensitivity and spectral information in the low ultraviolet.  相似文献   

10.
Continuing our earlier study of the retention behaviour in reversed-phase systems with aqueous mobile phases containing surfactants in concentrations lower (submicellar systems) and higher (micellar systems) than the critical micellar concentration (CMC), we investigated the chromatographic behaviour of various non-ionic solutes in mixed aqueous-organic micellar and submicellar mobile phases and their dependence on the methanol concentration. CMC values were measured for two cationic surfactant and one anionic surfactant in mixed aqueous-methanolic solvents, and were found to increase slightly with increasing methanol concentration. Depending on the character of the surfactant, a limiting concentration of methanol was found, above which micelles do not occur anymore. Sorption isotherms of the surfactants on an octylsilica gel column were measured as a function of the concentration of methanol in aqueous-methanolic solvents. A modified Langmuir equation was used to describe the distribution of the surfactants between the stationary and the mobile phases in the concentration range below CMC. The retention of several polar solutes was measured on an octylsilica gel column both in micellar and submicellar mobile phases containing methanol. The dependencies of the capacity factors of the solutes studied on the concentration of methanol in the mobile phase can be suitably described by the same form of equation as that conventionally used for aqueous-organic mobile phases that do not contain surfactants, but the slopes of the dependencies for a given solute are different in the two ranges of surfactant concentrations. The ratio of the two slopes is controlled by the interaction with micelles and is approximately equal to, below or above 1, depending on whether the solutes do or do not associate with the micelles, or are repulsed from them. Simultaneous control of the concentrations of the organic solvent and of the surfactant in the mobile phase can be used for fine tuning the selectivity of separation as a complement to commonly used adjusting concentrations of two organic solvents in ternary aqueous-organic mobile phases. These effects are illustrated by practical examples of submicellar HPLC with mobile phases containing methanol.  相似文献   

11.
Caccamese S  Bianca S  Carter GT 《Chirality》2009,21(6):569-577
A direct liquid chromatographic enantioselective separation of venlafaxine and 11 analogs was obtained in the normal phase mode using Chiralpak AD. For some compounds, a comparison between the enantioseparation using coated and immobilized amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phases (Chiralpak AD and Chiralpak IA, respectively) was made. The best separations were achieved on Chiralpak AD with ethanol as alcoholic modifier in a mobile phase made basic by DEA addition: separation factor ranges between 2.08 and 1.15 and resolution factor between 7.0 and 1.0. Using the same CSP and 2-propanol doped with TFA as acidic modifier, 10 compounds were enantioseparated with separation factor ranging between 1.40 and 1.04 and resolution factor between 3.1 and 0.3. The use of ethanol as alcoholic modifier also has the advantage of better solubility of the compounds in the mobile phase. The nature of the substituent (electron donating or withdrawing) affects in general the separation factor. A memory effect that involves a long equilibration time of the CSP is present when switching from an acidic mobile phase to a basic one.  相似文献   

12.
Chen S  Ward T 《Chirality》2004,16(5):318-330
A variety of compounds containing amines (i.e., amino acids, amino alcohols, etc.) were chemically derivatized with a variety of electrophilic tagging reagents to elucidate the chiral recognition sites on a teicoplanin-bonded chiral stationary phase (CSP) and on R-naphthylethylcarbamate-beta-cyclodextrin (RN-beta-CD)-bonded CSP. Solutes were separated under optimum chromatographic conditions on teicoplanin and RN-beta-CD CSPs for comparison using an acetonitrile-based mobile phase. It was noted that the size of the analyte or tagging reagent exerted a greater influence on compounds separated on teicoplanin than on RN-beta-CD when using the polar organic mode. This suggests that chiral recognition on teicoplanin CSP is more sensitive to size and indicates that the hydrophobic pocket of teicoplanin plays a significant role in chiral recognition in this mode. However, the type of functional groups had a greater impact than the size of analyte on separations obtained from RN-beta-CD phase in the polar-organic mode. Specifically, the pi-pi interaction was enhanced by derivatizing the aromatic ring of the tagging reagent with electron-withdrawing groups and thus altered the resolution substantially. For both phases, chiral recognition is most pronounced when the stereogenic center of the analyte is near the tagging moiety and surrounded by functional groups (e.g., carboxylic, etc.) which are favorable for hydrogen bonding.  相似文献   

13.
A systematic optimization of the HPLC separation of a complex mixture containing urinary steroids (anabolics and corticoids), boldenone and bolasterone (synthetic anabolics) by micellar liquid chromatography has been carried out. The isocratic micellar mobile phases (from binary to quaternary) consisted of sodium dodecyl sulphate and organic modifiers such as acetonitrile, tetrahydrofuran, propanol, butanol or pentanol. The effect of the organic modifiers, surfactant concentration, temperature, ionic strength and flow-rate on the separation has been studied. A micellar mobile phase made of 5% propanol and 40 mM surfactant allowed the separation of 13 steroids in about 23 min. A bivariant optimization method for the micellar mobile phase surfactant-propanol corroborated the above results. The separations obtained show good perspectives for future developments.  相似文献   

14.
As supercritical fluid chromatography becomes more accepted as a facile means for the separation of chiral compounds, the need for mobile phases that can readily solubilize these polar compounds grows. Prior studies suggest that HFC-134a may prove suitable due to its very high eluotropic strength compared to carbon dioxide-based mobile phases. A comparison is made between ethanol-modified carbon dioxide, HFC-134a, and decafluoropentane as to their relative eluotropic strength, selectivity, and efficiency for three chiral compounds using a Whelk O-1 chiral bonded phase. The bulk component of the mobile phase was found to have relatively little effect on chiral selectivity over the range of 5° to 95°C. Chirality 9:693–698, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

15.
The separation of tryptophan enantiomers was carried out with medium-pressure liquid chromatography using BSA (bovine serum albumin)-bonded silica as a chiral stationary phase. The influence of various experimental factors such as pH and ionic strength of mobile phase, separation temperature, and the presence of organic additives on the resolution was studied. In order to expand this system to preparative scale, the loadability of sample and the stability of stationary phase for repeated use were also examined. The separation of tryptophan enantiomers was successful with this system. The data indicated that a higher separation factor (α) was obtained at a higher pH and lower temperature and ionic strength in mobile phase. Addition of organic additives (acetonitrile and 2-propanol) in mobile phase contributed to reduce the retention time of L-tryptophan. About 30% of the separation factor was reduced after 80 days of repeated use.  相似文献   

16.
The normal phase mode liquid chromatographic enantiomer separation capability of a quinine tert-butyl-carbamate-type chiral stationary phase (CSP) has been investigated for a set of polar [1,5-b]-quinazoline-1,5-dione derivatives. This class of chiral heterocycles is currently under development as potential alpha-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) and/or N-methyl-D-aspartic acid (NMDA) receptor antagonists. The effect of the nature and concentration of polar modifier, i.e., ethanol and isopropanol, in n-hexane-based mobile phases, as well as the substituent pattern of the phenyl ring attached to the quinazolone framework on retention factor, enantioselectivity, and resolution was investigated. The Soczewiński competitive adsorption model was used to describe the relationship between the retention and the binary mobile phase compositions. According to this model, linear plots of the logarithms of retention factor versus molar fractions of the polar modifiers were obtained over a wide concentration range (X(B) between 0.15 and 0.35). Addition of equimolar ethanol yields higher resolution than isopropanol, R(S) values ranging between 1.54 and 2.75, whereas the latter allows to achieve moderately increased enatioselectivity. The resolution was further improved by using a ternary mixture of n-hexane:methanol:isopropanol/85:5:10 (v/v). The most pronounced selectivity factor alpha and resolution R(S) values were obtained for the para-hydroxy substituted compound, indicating that chiral recognition is sensitive to steric and stereoelectronic factors. In the course of optimization, the temperature-dependence on the chiral separation was also investigated. It turned out that the enantiomer separation is predominantly enthalpically driven in normal phase mode.  相似文献   

17.
The direct separation of enantiomeric amines has been carried out using a chiral counter ion, (?)-2,3:4,6,-di-O-isopropylidene-2-keto-L -gulonic acid [(?)-DIKGA] dissolved in polar mobile phases, water:methanol or isopropanol:acetonitrile. High separation factors, α = 1.2–1.7, were obtained for several compounds of pharmacological interest such as metoprolol, oxprenolol, remoxipride, mefloquine and p-OH-ephedrine. © 1993 Wiley-Liss, Inc.  相似文献   

18.
The well documented hydrolysis of the α-hydroxy-δ-lactone ring moiety in camptothecin and related analogues is routinely monitored using high-performance liquid chromatography (HPLC). Previous HPLC separations of the lactone and carboxylate forms of camptothecins have often required mobile phases containing three to four components; ion-pairing reagent to provide adequate retention of the carboxylate form of the drug; buffer to control the ionic strength and pH of the mobile phase; acetonitrile to control the retention of the lactone form and, in some instances, sodium dodecyl sulfate to reduce peak tailing. Because of the complexity of the mobile phases employed, development of these assays can be a laborious process, requiring re-optimization for each new analogue. In this study, we have developed a simple HPLC methodology for the simultaneous separation of the lactone and carboxylate forms of numerous camptothecin analogues. The mobile phase employed includes only triethylamine acetate (TEAA) buffer and acetonitrile. In this application, triethylamine serves multiple roles; as the ion-pairing reagent, as a masking agent for underivatized silanols and as the major buffer component. By altering only the composition of TEAA buffer with respect to acetonitrile, method development becomes a more streamlined and time efficient process. In this publication, we present the simultaneous separation of the lactone and carboxylate forms of camptothecin and four related analogues, namely, topotecan, GI 147211, 10-aminocamptothecin and the CPT-I I-SN-38 drug-metabolite pair. It is proposed that this new mobile phase, consisting of only triethylamine acetate buffer and acetonitrile, can be used for the analysis of the several camptothecin derivatives presently in clinical trials as well as the numerous other analogues in preclinical development.  相似文献   

19.
Direct high‐performance liquid chromatographic (HPLC) separation of four bicyclo[2.2.2]octane based 2‐amino‐3‐carboxylic acid enantiomers were developed on chiral stationary phases (CSPs) containing different macrocyclic glycopeptide antibiotic selectors. The analyses were performed under reversed‐phase, polar organic and polar ionic mode on macrocyclic‐glycopeptide‐based Chirobiotic T, T2, TAG, and R columns. The effects of the mobile phase composition including the acid and base modifier, the structure of the analytes, and the temperature on the separations were investigated. Experiments were achieved at constant mobile phase compositions on different stationary phases in the temperature range 5–40°C. Thermodynamic parameters were calculated from plots of ln k or ln α versus 1/T. It was recognized that the enantioseparations in reversed‐phase and polar organic mode were enthalpically driven, but under polar‐ionic conditions entropically driven enantioseparation was observed as well. Baseline separation and determination of elution sequence were achieved in all cases. Chirality 26:200–208, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

20.
A direct, isocratic, and simple reversed-phase HPLC method was described for the separation of enantiomers of the proton pump inhibitor, rac-pantoprazole (PAN) using cellulose-based chiral stationary phases (Chiralcel OD-R and Chiralcel OJ-R). Some structurally related chiral benzimidazole sulfoxides, rac-omeprazole (OME) and raclansoprazole (LAN), were also studied. Chiralcel OJ-R was successful in the resolution of enantiomers of rac-PAN and rac-OME, while Chiralcel OD-R was most suitable for resolving the enantiomers of rac-LAN. Highest enantioselectivity to rac-PAN and rac-OME was achieved on Chiralcel OJ-R by using acetonitrile as an organic modifier, whereas methanol afforded better resolution of rac-LAN on Chiralcel OD-R than acetonitrile. Increases in buffer concentration and column temperature decreased retention and did not improve the resolution of the enantiomers on both columns. Using a mixture of 50 mM sodium perchlorate solution and acetonitrile as a mobile phase at a flow rate of 0.5 ml/min, maximum separation factors of 1.26 and 1.13 were obtained for the enantiomers of rac-PAN and rac-OME using a Chiralcel OJ-R column, while maximum separation factor of 1.16 was obtained for the enantiomers of rac-LAN using a Chiralcel OD-R column. © 1995 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号