首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An N-acetyl-β-d-hexosaminidase has been purified from primary wheat leaves (Triticum aestivum L.) by freeze-thawing, (NH4)2SO4 precipitation, methanol precipitation, gel filtration, cation exchange chromatography and affinity chromatography on concanavalin A-Sepharose. The activity of the purified preparations could be stabilised by addition of Triton X-100 and the enzyme was stored at -20°C without significant loss of activity. The enzyme hydrolysed pNP-β-d-GlcNAc (optimum pH 5.2, Km 0.29 mM, Vmax 2.56 μkat mg−1) and pNP-β-d-GalNAc (optimum pH 4.4, Km 0.27 mM, Vmax 2.50 μkat mg−1). Five major isozymes were identified, with isoelectric points in the range 5.13–5.36. All five isozymes possessed both N-acety-β-d-glucosaminidase and N-acetyl-β-d-galactosaminidase activity. Inhibition studies and mixed substrate analysis suggested that both substrates are catalysed by the same active site. Both activities were inhibited by GlcNAc, 2-acetamido-2-deoxygluconolactone, GalNAc and the ions of mercury, silver and copper. The Kis for inhibition of N-acetyl-β-d-glucosaminidase activity were: GlcNAc (15.3 mM) and GalNAc (3.4mM). For inhibition of N-acety-β-d-galactosaminidase activity the corresponding values were: GlcNAc (18.2 mM) and GalNac (2.5 mM). The enzyme was considerably less active at releasing pNP from pNP-β-d-(GlcNAc)2 and pNP-β-d-(GlcNAc)3 than from pNP-β-d-GlcNAc. The ability of the N-acetyl-β-d-hexosaminidase to relase GlcNAc from chitin oligomers (GlcNAc)2 (optimum pH 5.0) and (GlcNAc)3−6 (optimum pH 4.4) was also low. Analysis of the reaction products revealed that the initial products from the hydrolysis of (GlcNAc)n were predominantly (GlcNAc)n−1 and GlcNAc.  相似文献   

2.
Leech blood apparently contains considerably less chloride than generally used in physiological experi ments. Instead of 85–130 mM Cl used in experimental salines, leech blood contains around 40 mM Cl and up to 45 mM organic anions, in particular malate. We have reinvestigated the distribution of Cl across the cell membrane of identified glial cells and neurones in the central nervous system of the leech Hirudo medicinalis L., using double-barrelled Cl- and pH-selective micro electrodes, in a conventional leech saline, and in a saline with a low Cl concentration (40 mM), containing 40 mM malate. The interference of anions other than Clto the response of the ion-selective microelectrodes was estimated in Cl-free salines (Cl replaced by malate and/or gluconate). The results show that the absolute intracellu lar Cl activities (aCli) in glial cells and neurones, but not the electrochemical gradients of Cl across the glial and the neuronal cell membranes, are altered in the low Cl, malate-based saline. In Retzius neurones, aCli is lower than expected from electrochemical equilibrium, while in pressure neurones and in neuropil glial cells, aCli is distributed close to its equilibrium in both salines, re spectively. The steady-state intracellular pH values in the glial cells and Retzius neurones are little affected (0.1 pH units) in the low Cl, malate-based saline.  相似文献   

3.
The potential of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) have been investigated for the separation and quantitative determination of 10 quinolone antibiotics. The influence of different conditions, such as the buffer and pH of the electrolyte, the surfactant and the ion-pairing agents added to the electrolyte and the organic modifier were studied. A buffer consisting of 40 mM sodium tetraborate at pH 8.1 containing 10% (v/v) methanol was found to be a highly efficient electrophoretic system for separating lomefloxacin, enoxacin, norfloxacin, pipemidic acid, ofloxacin, piromidic acid, flumequine, oxolinic acid, cinoxacin and nalidixic acid. A solid-phase extraction method to remove the sample matrix (pig plasma samples) was developed on a C18 cartridge using a mixture of methanol–water (70:30, v/v). The method is specific and reproducible and mean recoveries were in the range 94.0±4.2% and 123.3±4.1% for pig plasma samples over the range used. A linear relationship between concentration and peak area for each compound in pig plasma samples was obtained in the concentration range 5–20 mg l−1 and detection limits were between 1.1 and 2.4 mg l−1.  相似文献   

4.
The yeast Cryptococcus flavus secretes a glycosylated α-amylase (Amy1) when grown in a starch-containing medium. The effects of N-glycosylation on secretion, enzyme activity, and stability of this glycoprotein were studied. Addition of tunicamycin (TM) to the medium at a concentration higher than 0.5 μg mL−1 affected C. flavus growth. Amy1 activity increased by 55% in the intracellular fraction after C. flavus growth in the presence of 0.5 μg mL−1 TM. SDS–PAGE and gel activity detection showed that native enzyme and deglycosylated enzyme had apparent molecular mass of 68 and 64.5 kDa, respectively. The N-glycosylation process did not affect either optimum pH or optimum temperature. The KM values of native and non-glycosylated α-amylases were 0.052 and 0.098 mg mL−1, and Vmax values were 0.038 and 0.047 mg min−1, respectively. However, the non-glycosylated form was more sensitive to inactivation by both the proteolytic enzyme trypsin and high temperature. Furthermore, the activity of the non-glycosylated enzyme was affected by Hg2+ and Cu2+ suggesting that N-glycosylation is involved in the folding of Amy1.  相似文献   

5.
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde–N-acetylcysteine (OPA–NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8±2×10−2 min−1 in solution versus 7.7±1.1×10−4 min−1 on the (C18) solid support. The results obtained showed that forming the derivative on the packing support (C18) gave the best results following this procedure: conditioning the cartridges with borate buffer (1 ml, 0.5 M, pH 8), retention of the analyte, addition of 0.8 ml of OPA–NAC reagent, 0.2 ml borate buffer 0.8 M (pH 8) and elution of the isoindol with 3 ml of MeOH–borate buffer (9:1). The different derivatization procedures have been used to study the stability of the reaction products OPA–NAC polyamines formed in urine matrix using spermine as model compound. Similar results were obtained for standard solutions and urine samples.  相似文献   

6.
Capillary zone electrophoresis was employed for the measurement of chloramphenicol using end-column amperometric detection with a carbon fiber micro-disk array electrode, at a constant potential of −1.00 V vs. saturated calomel electrode. The effect of oxygen in the buffer has been investigated. It is found that when the area of the carbon fiber electrode is smaller than 1.1 mm2, the interference of oxygen can be overcome. In this procedure deoxygenation is not necessary. The effect of pH, the concentration of the buffer and the high separation voltage across the capillary on the migration time, electrophoretic peak current and separation efficiency has been studied. The optimum conditions of separation and detection are 8.4×10−4 mol/l HOAc–3.2×10−3 mol/l NaOAc for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The calibration plot was found to be linear in the range 5×10−6 to 1×10−3 mol/l and the limit of detection is 9.1×10−7 mol/l or 1.4 fmol (S/N=2). The relative standard deviation is 1.1% for the migration time and 2.3% for the electrophoretic peak current. The method was applied to the determination of chloramphenicol in human serum.  相似文献   

7.
A sensitive and reliable high-performance liquid chromatographic (HPLC) method, using a solid-phase extraction (SPE), was established and validated for determination of p,p′-DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] and its metabolite p,p′-DDE [1,1-(2,2-dichloroethanylidene)-bis(4-chlorobenzene)] in rat plasma, liver and brain. After being diluted with water, plasma, liver and brain samples were applied to a solid-phase extraction C18 cartridge. The extraction containing p,p′-DDT and p,p′-DDE from the cartridge were cleaned-up using a Florisil Sep-Pak cartridge. The samples were analyzed by HPLC using UV detection at 238 nm. The limit of detection for p,p′-DDT and p,p′-DDE was 0.1 mg kg−1 liver or brain and 0.1 mg l−1 plasma. For six replicate samples at 40, 4 and 0.2 mg kg−1, intra-day precision values were within 4.9% for plasma, 6.4% for liver, and 9.7% for brain. Inter-day precision values at 4 mg kg−1 were within 8.2% for plasma and tissues. The method performances were shown to be selective for p,p′-DDT and p,p′-DDE, and linear over the range 0.04–12 mg kg−1 (mg l−1 for plasma). The absolute recoveries of p,p′-DDT and p,p′-DDE in rat plasma and tissues were over 92%. The method was proved to be applicable to the pharmacokinetic study of DDT in rats after a single oral administration.  相似文献   

8.
A simple, highly selective and reproducible reversed-phase high-performance liquid chromatography method has been developed for the analysis of the new anti-cancer pro-drug AQ4N. The sample pre-treatment involves a simple protein precipitation protocol, using methanol. Chromatographic separations were performed using a HiChrom HIRPB (25 cm×4.6 mm I.D.) column, with mobile phase of acetonitrile–ammonium formate buffer (0.05 M) (22:78, v/v), with final pH adjusted to 3.6 with formic acid. The flow-rate was maintained at 1.2 ml min−1. Detection was via photodiode array performed in the UV range at 242 nm and, since the compounds are an intense blue colour, in the visible range at 612 nm. The structurally related compound mitoxantrone was used as internal standard. The validated quantification range of the method was 0.05–10.0 μg ml−1 in mouse plasma. The inter-day relative standard deviations (RSDs) (n=5) ranged from 18.4% and 12.1% at 0.05 μg ml−1 to 2.9% and 3.3% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The intra-day RSDs for supplemented mouse plasma (n=6) ranged from 8.2% and 14.2% at 0.05 μg ml−1 to 7.6% and 11.5% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The overall recovery of the procedure for AQ4N was 89.4±1.77% and 76.1±7.26% for AQ4. The limit of detection was 50 ng ml−1 with a 100 μl sample volume. The method described provides a suitable technique for the future analysis of low levels of AQ4N and AQ4 in clinical samples.  相似文献   

9.
A hydrogen peroxide permselective membrane with asymmetric structure was prepared and -glucose oxidase (EC 1.1.3.4) was immobilized onto the porous layer. The activity of the immobilized -glucose oxidase membrane was 0.34 units cm−2 and the activity yield was 6.8% of that of the native enzyme. Optimum pH, optimum temperature, pH stability and temperature stability were found to be pH 5.0, 30–40°C, pH 4.0–7.0 and below 55°C, respectively. The apparent Michaelis constant of the immobilized -glucose oxidase membrane was 1.6 × 10−3 mol l−1 and that of free enzyme was 4.8 × 10−2 mol l−1. An enzyme electrode was constructed by combination of a hydrogen peroxide electrode with the immobilized -glucose oxidase membrane. The enzyme electrode responded linearly to -glucose over the concentration 0–1000 mg dl−1 within 10 s. When the enzyme electrode was applied to the determination of -glucose in human serum, within day precision (CV) was 1.29% for -glucose concentration with a mean value of 106.8 mg dl−1. The correlation coefficient between the enzyme electrode method and the conventional colorimetric method using a free enzyme was 0.984. The immobilized -glucose oxidase membrane was sufficiently stable to perform 1000 assays (2 to 4 weeks operation) for the determination of -glucose in human whole blood. The dried membrane retained 77% of its initial activity after storage at 4°C for 16 months.  相似文献   

10.
The Cl conductance in isolated skin of frogs (Rana catesbeiana) acclimated to 30 mM solutions of NaCl, Na2SO4, MgCl2 and distilled water (DW) was studied. Transepithelial potential difference (PDtrans), short-circuit current (ISC) and total conductance (Gt) were measured under conditions such that there was Cl flux in the presence and absence of Na+ transport. The Cl content of the mucosal solution was acutely replaced with SO42− or gluconate to evaluate the effect of removal of Cl conductance on electrophysiological parameters. Mitochondria-rich cell density (DMRC) was also measured. Skins from frogs acclimated to NaCl and Na2SO4 showed the lowest and the highest DMRC, respectively, but no difference could be found between the skins from frogs acclimated to DW and MgCl2 indicating that DMRC is not unconditionally dependent on environmental Cl in this species. Frogs acclimated to NaCl showed marked differences when compared to the other groups: the highest Gt, probably represented by a higher paracellular conductance; the lowest transepithelial electrical potential difference which remained invariant after replacement of mucosal Cl with SO42− or replacement of mucosal Cl with gluconate and an inwardly oriented positive current in the absence of bilateral Na+.  相似文献   

11.
A decrease in nutrient Cl results in an increased negativity of the nutrient relative to the secretory side. The possibility emerged that Cl transport could be attributed to a neutral mechanism involving Cl in the nutrient membrane coupled to a simple Cl conductance pathway in the secretory membrane. The decrease in PD (potential difference) with a decrease in nutrient Cl could arise from a decrease in cellular Cl so that the ratio of Cl in cell to Cl in secretory solution was decreased. Experiments were designed to determine whether there was a need to assume a simple Cl conductance pathway. A 10-fold decrease in Cl gave in HCO3-containing nutrient solutions a PD decrease of 20 mV, in HCO3-free nutrient solutions, a PD decrease of 13.5 mV, and in HCO3-free and Na+-free solutions, a PD decrease of 6.7 mV. The decrease of 6.7 mV could not be attributed to a neutral ClHCO3 exchanger or a NaCl symport. Also there was no evidence for a KCl symport from changes in Cl in presence and absence of K+. It followed that the decrease of 6.7 mV provided evidence for a simple Cl conductance pathway in the nutrient membrane.  相似文献   

12.
An isocratic reversed-phase HPLC method was developed to determine cefepime levels in plasma and vitreous fluid. Cefepime and the internal standard cefadroxil were separated on a Shandon Hypersil BDS C18 column by using a mobile phase of 25 mM sodium dihydrogen phosphate monohydrate (pH 3) and methanol (87:13, v/v). Ultraviolet detection was carried out at 270 nm. The retention times were 4.80 min for cefepime and 7.70 min for cefadroxil. This fast procedure which involves an efficient protein precipitation step (addition of HClO4), allows a quantification limit of 2.52 μg ml−1 and a detection limit of 0.83 μg ml−1. Recoveries and absolute recoveries of cefepime from plasma were 96.13–99.44% and 94–102.5% respectively. The intra-day and inter-day reproducibilities were less than 2% for cefepime at 10, 30, 50 μg ml−1 (n=10).The method was proved to be suitable for determining cefepime levels in human plasma and was modified to measure vitreous fluid samples.  相似文献   

13.
A new electrochemical method to monitor biotin–streptavidin interaction on carbon paste electrode, based on silver electrodeposition catalyzed by colloidal gold, was investigated. Silver reduction potential changed when colloidal gold was attached to an electrode surface through the biotin–streptavidin interaction. Thus, the direct reduction of silver ions on the electrode surface could be avoided and therefore, they were only reduced to metallic silver on the colloidal gold particle surface, forming a shell around these particles. When an anodic scan was performed, this shell of silver was oxidized and an oxidation process at +0.08 V was recorded in NH3 1.0 M. Biotinylated albumin was adsorbed on the pretreated electrode surface. This modified electrode was immersed in colloidal gold-streptavidin labeled solutions. The carbon paste electrode was then activated in adequate medium (NaOH 0.1 M and H2SO4 0.1 M) to remove proteins from the electrode surface while colloidal gold particles remained adsorbed on it. Then, a silver electrodeposition at −0.18 V for 2 min and anodic stripping voltammetry were carried out in NH3 1.0 M containing 2.0×10−5 M of silver lactate. An electrode surface preparation was carried out to obtain a good reproducibility of the analytical signal (5.3%), using a new electrode for each experiment. In addition, a sequential competitive assay was carried out to determine streptavidin. A linear relationship between peak current and logarithm of streptavidin concentration from 2.25×10−15 to 2.24×10−12 M and a limit of detection of 2.0×10−15 M were obtained.  相似文献   

14.
A high-performance liquid chromatographic method for the determination of penicillamine in plasma, whole blood, and urine samples is described. The method uses a commercially available electrochemical detector at a potential of +0.1 V versus the Ag/AgCl reference electrode. This method is selective and sensitive for sulfhydryl compounds. The chromatography separates penicillamine from other endogenous sulfhydryl compounds with a limit of detection for penicillamine in biological samples of ca. 10−7M.  相似文献   

15.
A column-switching liquid chromatography–electrospray ionization-tandem mass spectrometric (LC–ESI-MS–MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 μl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0–acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate–acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M−H] were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M−H] in MS–MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M−H−Glu], which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025–100 μg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78–103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.  相似文献   

16.
Non-protein-bound iron in human synovial fluid was determined using high-performance liquid chromatography with electrochemical detection. The procedure was based on the separation of the iron—diethylenetriaminepentaacetic acid (DPTA) complex formed directly on a chromatographic column containing an anion-exchange resin followed by electrochemical detection. The method enabled more than 0.1 μM Fe(III) to be determined with an injection volume of 10 μl. A mixture of synovial fluid, 20 μM DTPA and acetate buffer was incubated in the presence and absence of superoxide (O2) generated by a xanthine—xanthine oxidase system and was ultrafiltered through a 30 000 molecular mass cut-off filter. No iron was detected in the ultrafiltrate at physiological pH. However, the presence of iron was observed in the ultrafiltrate at low pH, and O2 and decreased pH, iron may be released into the synovial fluid.  相似文献   

17.
A multi-functional enzyme ICChI with chitinase/lysozyme/exochitinase activity from the latex of Ipomoea carnea subsp. fistulosa was purified to homogeneity using ammonium sulphate precipitation, hydrophobic interaction and size exclusion chromatography. The enzyme is glycosylated (14–15%), has a molecular mass of 34.94 kDa (MALDI–TOF) and an isoelectric point of pH 5.3. The enzyme is stable in pH range 5.0–9.0, 80 °C and the optimal activity is observed at pH 6.0 and 60 °C. Using p-nitrophenyl-N-acetyl-β-d-glucosaminide, the kinetic parameters Km, Vmax, Kcat and specificity constant of the enzyme were calculated as 0.5 mM, 2.5 × 10−8 mol min−1 μg enzyme−1, 29.0 s−1 and 58.0 mM−1 s−1 respectively. The extinction coefficient was estimated as 20.56 M−1 cm−1. The protein contains eight tryptophan, 20 tyrosine and six cysteine residues forming three disulfide bridges. The polyclonal antibodies raised and immunodiffusion suggests that the antigenic determinants of ICChI are unique. The first fifteen N-terminal residues G–E–I–A–I–Y–W–G–Q–N–G–G–E–G–S exhibited considerable similarity to other known chitinases. Owing to these unique properties the reported enzyme would find applications in agricultural, pharmaceutical, biomedical and biotechnological fields.  相似文献   

18.
A system of an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatograph-mass spectrometer (GC–MS) was developed for the simultaneous analysis of seven barbiturates in human serum. A sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading 1.5 ml of a diluted serum sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into the GC–MS. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.1 to 10 μg ml−1 for all barbiturates extracted. The proposed method was applied to 27 clinical serum samples from three patients who were administrated secobarbital.  相似文献   

19.
Hydroxylated radical products of salicylic acid are often used as a relative measurement in free radical research. Several analytical methods exist to determine the amount of 2,3-dihydroxybenzoic acid and 2,5-dihydroxybenzoic acid. In this study we use capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) in order to determine these free radical products. The CZE experiment was optimized with a CZE simulation program in order to achieve an optimal pH. Calibration curves were recorded in the range 10−6–10−4 M and the detection limit was determined. For both CZE and MECC it was 2·10−7 M. Both methods resulted in a reproducible analysis of salicylate and its hydroxylated free radical products in 6 min.  相似文献   

20.
(1) Thylakoids isolated from leaves of two salt-tolerant higher plant species were found to require high (greater than 250 mM) concentrations of Cl for maximal rates of photosynthetic O2 evolution and maximum variable chlorophyll a fluorescence yield. These activities were also tolerant to extremely high (2–3 M) salt concentrations. Their pH dependence was markedly different in the absence and presence of sufficient salt levels. (2) When Cl was provided as CaCl2, as opposed to MgCl2, KCl or NaCl, higher rates of O2 evolution were obtained, suggesting that Ca2+ has an important role in Photosystem II reactions. (3) The site of Cl action was located on the electron donor side of Photosystem II. (4) O2 evolution in the presence of optimal Cl concentrations showed a pH dependence closely matched by that of 35Cl-NMR line broadening, which is indicative of Cl binding. This pH-dependent 35Cl-NMR line-width broadening was not altered significantly by treatment of the thylakoids with EDTA; it was, however, abolished by heat treatment. (5) Only anions with similar ionic radii (Br, NO3) were effective in replacing Cl. Small anions such as F and OH were inhibitory; larger ions had no effect. The inhibition by F is due, at least in part, to displacement of Cl. The selectivity is attributed to a combination of steric and ionic field effects. (6) It is proposed that Cl facilitates Photosystem II electron transport by reversible ionic binding to the O2-evolving complex itself or to the thylakoid membrane in close proximity to it.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号