首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method for rapid sensitive detection of DNA or RNA was designed using a composite screen-printed carbon electrode modified with multi-walled carbon nanotubes (MWNTs). MWNTs showed catalytic characteristics for the direct electrochemical oxidation of guanine or adenine residues of signal strand DNA (ssDNA) and adenine residues of RNA, leading to indicator-free detection of ssDNA and RNA concentrations. With an accumulation time of 5 min, the proposed method could be used for detection of calf thymus ssDNA ranging from 17.0 to 345 microg ml(-1) with a detection limit of 2.0 microg ml(-1) at 3 sigma and yeast tRNA ranging from 8.2 microg ml(-1) to 4.1 mg ml(-1). AC impedance was employed to characterize the surface of modified electrodes. The advantages of convenient fabrication, low-cost detection, short analysis time and combination with nanotechnology for increasing the sensitivity made the subject worthy of special emphasis in the research programs and sources of new commercial products.  相似文献   

2.
Liu JX  Zhou WJ  Gong JL  Tang L  Zhang Y  Yu HY  Wang B  Xu XM  Zeng GM 《Bioresource technology》2008,99(18):8748-8751
An electrochemical sensor for detection of the activity of laccase from Penicillium simplicissimum isolated from the composting has been developed. The sensor is based on glassy carbon electrode modified with multi-wall carbon nanotubes (CNTs). The introduction of CNTs into this system can greatly enhance the electrochemical signal in this assay more sensitively, selectively and rapidly than that in conventional spectrophotometric assays. It was found that the optimal pH value of the electrolyte was 5.6. The results showed a good linear correlation between the current and the concentration of laccase activities measured by spectrophotometry, where the current slope was measured by chronoamperometry with a coefficient of 0.9835. Therefore, this electrochemical sensor can be used for rapid detection of laccase activity from P. simplicissimum. Furthermore, it may be potentially used for rapid quantification of P. simplicissimum according to the relationship between the laccase activities and the biomass.  相似文献   

3.
A high-performance amperometric fructosyl valine (FV) biosensor was developed, based on immobilization of fructosyl amino-acid oxidase (FAO) on core-shell magnetic bionanoparticles modified gold electrode. Chitosan was used to introduce amino groups onto the surface of core-shell magnetic bionanoparticles (MNPs). With FAO as an enzyme model, a new fructosyl valine biosensor was fabricated. The biosensor showed optimum response, when operated at 50 mVs(-1) in 0.1M potassium phosphate buffer, pH 7.5 and 35°C. The biosensor exhibited excellent sensitivity [the detection limit is down to 0.1mM for FV], fast response time (less than 4s), wide linear range (from 0 to 2mM). Analytical recovery of added FV was 95.00-98.50%. Within batch and between batch coefficients of variation were <2.58% and <5.63%, respectively. The enzyme electrode was used 250 times over 3 months, when stored at 4°C.  相似文献   

4.
A method for the electrochemical detection of antioxidants has been developed, which is based on a radical measurement with a cytochrome c modified electrode. A controlled enzymatic production system for superoxide radicals based on xanthine oxidase was used. The addition of antioxidants facilitated the decomposition of the radical in addition to the spontaneous dismutation. The steady-state of superoxide generation and decomposition was thus shifted to a new situation due to the higher decomposition rate after antioxidant addition. This resulted in a decreased current level at the electrode. Antioxidant activity could be quantified from the response of the sensor electrode by the percentage of the signal decrease. The 50% inhibition value (IC(50)) for different antioxidants was calculated and the antioxidant activity of numerous substances was compared. Thus, a hierarchy of superoxide radical scavenging abilities of flavonoids was established: flavanols>flavonols>flavones>flavonones>isoflavonones.  相似文献   

5.
A new electrochemical DNA biosensor for bovine papillomavirus (BPV) detection that was based on screen-printed electrodes was comprehensively studied by electrochemical methods of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A BPV probe was immobilised on a working electrode (gold) modified with a polymeric film of poly-L-lysine (PLL) and chitosan. The experimental design was carried out to evaluate the influence of polymers, probe concentration (BPV probe) and immobilisation time on the electrochemical reduction of methylene blue (MB). The polymer poly-L-lysine (PLL), a probe concentration of 1μM and an immobilisation time of 60min showed the best result for the BPV probe immobilisation. With the hybridisation of a complementary target sequence (BPV target), the electrochemical signal decreased compared to a BPV probe immobilised on the modified PLL-gold electrode. Viral DNA that was extracted from cattle with papillomatosis also showed a decrease in the MB electrochemical reduction, which suggested that the decreased electrochemical signal corresponded to a bovine papillomavirus infection. The hybridisation specificity experiments further indicated that the biosensor could discriminate the complementary sequence from the non-complementary sequence. Thus, the results showed that the development of analytical devices, such as a biosensor, could assist in the rapid and efficient detection of bovine papillomavirus DNA and help in the prevention and treatment of papillomatosis in cattle.  相似文献   

6.
The performance of a new glucose biosensor based on the combination of biocatalytic activity of glucose oxidase (GOx) with the electrocatalytic properties of CNTs and neutral red (NR) for the determination of glucose is described. This sensor is comprised of a multiwalled carbon nanotubes (MWNTs) conduit functionalized with NR and Nafion (Nf) as a binder and glucose oxidase as a biocatalyst. Neutral red was covalently immobilized on carboxylic acid groups of the CNTs via carbodiimide reaction. The functionalized MWNTs were characterized by microscopic, spectroscopic and thermal methods. The MWNT-NR-GOx-Nf nanobiocomposite was prepared by mixing the GOx solution with NR functionalized CNTs followed by mixing homogeneously with Nafion. The performance of the MWNT-NR-GOx-Nf nanobiocomposite modified electrode was examined by electrochemical impedance spectroscopy and cyclic voltammetry. The catalytic reduction of hydrogen peroxide liberated from the enzymatic reaction of glucose oxidase upon glucose with NR functionalized CNTs leads to the selective detection of glucose. The excellent electrocatalytic activity and the influence of nanobiocomposite film result in good characteristics such as low potential detection of glucose with a large determination range from 1 x 10(-8) to 1 x 10(-3)M with a detection limit of 3 x 10(-9)M glucose, a short response time (with 4s), good stability and anti-interferent ability. The improved electrocatalytic activity and stability made the MWNT-NR-GOx-Nf nanobiocomposite biosensor system a potential platform to immobilize different enzymes for other bioelectrochemical applications.  相似文献   

7.
The level of uric acid (UA) has a high relationship with gout, hyperuricemia and Lesch-Nyan syndrome. The determination of UA is an important indicator for clinics and diagnoses of kidney failure. An amperometric UA biosensor based on an Ir-modified carbon (Ir-C) working electrode with immobilizing uricase (EC 1.7.3.3) was developed by thick film screen printing technique. This is the first time to report the utilization of an uricase/Ir-C electrode for the determination of UA by using chronoamperometric (CA) method. The high selectivity of UA biosensor was achieved due to the reduction of H(2)O(2) oxidation potential based on Ir-C electrode. Using uricase/Ir-C as the sensing electrode, the interference from the electroactive biological species, such as ascorbic acid (AA) and UA (might be directly oxidized on the sensing electrode) was slight at the sensing potential of 0.25 V (versus Ag/AgCl). UA was detected amperometrically based on uricase/Ir-C electrode with a sensitivity of 16.60 microAmM(-1) over the concentration range of 0.1-0.8 mMUA, which was within the normal range in blood. The detection limit of UA biosensor was 0.01 mM (S/N=6.18) in pH 7 phosphate buffer solution (PBS) at 37 degrees C. The effects of pH, temperature, and enzymatic loading on the sensing characteristics of the UA biosensor were also investigated in this study.  相似文献   

8.
In this work, we present an electrochemical DNA sensor based on silver nanoparticles/poly(trans-3-(3-pyridyl) acrylic acid) (PPAA)/multiwalled carbon nanotubes with carboxyl groups (MWCNTs-COOH) modified glassy carbon electrode (GCE). The polymer film was electropolymerized onto MWCNTs-COOH modified electrode by cyclic voltammetry (CV), and then silver nanoparticles were electrodeposited on the surface of PPAA/MWCNTs-COOH composite film. Thiol group end single-stranded DNA (HS-ssDNA) probe was easily covalently linked onto the surface of silver nanoparticles through a 5′ thiol linker. The DNA hybridization events were monitored based on the signal of the intercalated adriamycin by differential pulse voltammetry (DPV). Based on the response of adriamycin, only the complementary oligonucleotides gave an obvious current signal compared with the three-base mismatched and noncomplementary oligonucleotides. Under the optimal conditions, the increase of reduction peak current of adriamycin was linear with the logarithm of the concentration of the complementary oligonucleotides from 9.0 × 10−12 to 9.0 × 10−9 M with a detection limit of 3.2 × 10−12 M. In addition, this DNA sensor exhibited an excellent reproducibility and stability during DNA hybridization assay.  相似文献   

9.
A biosensor for trace metal ions based on horseradish peroxidase (HRP) immobilized on maize tassel-multiwalled carbon nanotube (MT-MWCNT) through electrostatic interactions is described herein. The biosensor was characterized using Fourier transform infrared (FTIR), UV–vis spectrometry, voltammetric and amperometric methods. The FTIR and UV–vis results inferred that HRP was not denatured during its immobilization on MT-MWCNT composite. The biosensing principle was based on the determination of the cathodic responses of the immobilized HRP to H2O2, before and after incubation in trace metal standard solutions. Under optimum conditions, the inhibition rates of trace metals were proportional to their concentrations in the range of 0.092–0.55 mg L−1, 0.068–2 mg L−1 for Pb2+ and Cu2+ respectively. The limits of detection were 2.5 μg L−1 for Pb2+ and 4.2 μg L−1 for Cu2+. Representative Dixon and Cornish-Bowden plots were used to deduce the mode of inhibition induced by the trace metal ions. The inhibition was reversible and mixed for both metal ions. Furthermore, the biosensor showed good stability, selectivity, repeatability and reproducibility.  相似文献   

10.
A biosensor for glucose using glucose dehydrogenase immobilized on a chemically modified graphite electrode was supplied with coenzyme, nicotinamide adenine dinucleotide (NAD+), through pores in the material. A graphite rod was hollowed out, leaving 0.3 mm at the end contacting the solution, filled with 10 mM NAD+ and pressurized. The response factor was 40% of that obtained when 2 mM NAD+ was mixed with the sample solution in a flow system. The coenzyme consumption was 11 microliters h-1 representing a 500-fold saving compared to supply through the bulk solution. The biosensor had a linear calibration curve from the detection limit, 1 microM, to 2 mM glucose and a repeatability of 0.3%. The graphite electrode was modified by adsorption of a bis-(benzophenoxazinyl)-terephthaloyl derivative in order to be able to oxidize NADH at 0 mV versus Ag/AgCl, 0.1 M KCl.  相似文献   

11.
The report is on an electrochemical biosensor with remarkably improved sensitivity toward nitrite. In this strategy, positively charged gold nanoparticle (PCNA) is used in combination with multiwall carbon nanotubes (MWCNT) by electrostatic adsorption for fabricating PCNA/MWCNT films. Then hemoglobin (Hb) biocatalyst will easily be attached to the surface of the combination films aforementioned. After that, the Hb/PCNA films are immobilized onto the Hb/PCNA/MWCNT films through layer-by-layer assembly technique. The (Hb/PCNA)2/MWNT/GC electrode thus prepared exhibits enhanced electrocatalytic behavior to the reduction of nitrite at −0.10 V versus SCE in 0.05 M H2SO4 solution. On condition of the low detecting potential and low pH, interference caused by direct electrochemical oxidation or oxidizable substances can be prevented. Therefore, the modified electrode shows fast response time, very high sensitivity, good selectivity and stability. The current response of the sensor increases linearly with nitrite concentration from a range of 3.6 × 10−6 to 3.0 × 10−3 M with a detection limit(S /N = 3) of 9.6 × 10−7 M.  相似文献   

12.
Overoxidized polypyrrole/multi-walled carbon nanotubes (OPPy/MWNTs) modified electrode has been developed for sensitively detecting dopamine (DA). OPPy films developed outside MWNTs might have a porous morphology. Thus, OPPy/MWNTs films developed by this method do not reject ascorbic acid (AA). However, OPPy/MWNTs modified electrode shows largely enhancing oxidative current responses of DA. When combined with liquid chromatography, it not only obtains a low detection limit of 7.5 × 10?10 mol L?1 for DA, but also improves the selectivity of DA detection. Mechanisms for the enhancement are also well discussed in this paper. With this approach, microdialysis has been employed for successful assessment of DA in rat striatum.  相似文献   

13.
A novel screen-printed electrode (SPEs) on sheets of vegetable parchment was prepared. The obtained SPEs were stable, convenient, inexpensive and suitable for large-area screen-printing. With these SPEs, we explored the fabrication of a novel, disposable and highly sensitive electro-analytical immunosensor using graphene nanosheets (GS) and horseradish peroxidase (HRP)-labeled signal antibody functionalized with gold nanoparticles (HRP-Ab(2)/Au NPs). GS was used to increase the conductivity and stability of this immunosensor due to its fast electron transportation and good biocompatibility. Au NPs could not only provide a large surface area for the immobilization of HRP-Ab(2) but also enhance the electroreduction between HRP and H(2)O(2) to amplify the electrochemical signal on the sandwich immuno-complexes modified SPEs. The proposed SPEs were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical methods involving cyclic voltammetry (CV), and electrochemical impedence method. Using prostate specific antigen (PSA) as a model analyte, this immunosensor showed a wide linear range over 6 orders of magnitude with the minimum value down to 2pgmL(-1). In addition, this immunosensor could avoid the need of deoxygenation for the electrochemical immunoassay. Thus, it provided a promising potential in clinical applications.  相似文献   

14.
Perturbation of the tubulin/microtubule dynamic in cells is perhaps the single most important mode of action of anticancer drugs. Standard methods for identifying and evaluating compounds for their ability to alter tubulin polymerization are low throughput, labor intensive, expensive, or make their assessment in vitro. Here we report a method to rapidly quantify the extent of tubulin polymerization in whole cells using flow cytometry, and we use this technique to evaluate compounds that stabilize and destabilize microtubule formation. This facile method is useful for conveniently, quantitatively, and cost-effectively comparing small molecules that perturb tubulin polymerization.  相似文献   

15.
《IRBM》2008,29(2-3):202-207
This paper deals with the development of a disposable electrochemical sensor for the detection of hydrogen peroxide, using screen-printed carbon-based electrodes (SPCEs) modified with multi-wall carbon nanotubes (MWCNs) dispersed in a polyethylenimine (PEI) mixture. The modified sensors showed an excellent electrocatalytic activity towards the analyte, respect to the high overvoltage characterising unmodified screen-printed sensors. The composition of the PEI/MWCNT dispersion was optimised in order to improve the sensitivity and reproducibility. The optimised sensor showed good reproducibility (10% RSD calculated on three experiments repeated on the same electrode), whereas a reproducibility of 15% as RSD was calculated on electrodes from different preparations. Preliminary experiments carried out using glucose oxidase (GOD) as biorecognition element gave rise to promising results indicating that these new devices may represent interesting components for biosensor construction.  相似文献   

16.
A sulfite oxidase (SOX) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto Prussian blue nanoparticles/polypyrrole (PBNPs/PPY) nanocomposite film electrodeposited onto the surface of gold (Au) electrode. An electrochemical sulfite biosensor was fabricated using SOX/PBNPs/PPY/Au electrode as working electrode, Ag/AgCl as standard electrode and Pt wire as auxiliary electrode connected through a potentiostat. The working electrode was characterized by Fourier Transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) at different stages of its construction. The biosensor showed optimum response within 2 s, when operated at 20 mV s−1 in 0.1 M Tris–HCl buffer, pH 8.0 and at 30 °C. Linear range and minimum detection limit were 0.5–1000 μM and 0.1 μM (S/N = 3) respectively. The sensor was evaluated with 95.0% recovery of added sulfite in red wine samples and 1.9% and 3.3% within and between batch coefficients of variation respectively. There was a good correlation (r = 0.96) between red wine samples sulfite value by standard DTNB method and the present method. The sensor was employed for determination of sulfite level in red, white and rose wine samples. The enzyme electrode was used 300 times over a period of 4 months, when stored at 4 °C.  相似文献   

17.
A sensitive electrochemical method for DNA hybridization based on immobilization of DNA probe and [Ru(NH3)5Cl]PF6 complex onto nickel oxide nanomaterials (NiOxnp) modified glassy carbon electrode was developed. Due to strong affinity of NiOxnp for phosphate groups, oligonucleotides probe with a terminal 5′-phosphate group was attached to the surface of the modified electrode. DNA immobilization and hybridization were characterized by electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry using K3Fe(CN)6/K4Fe(CN)6 and [Ru(NH3)5Cl]PF6 as probe and indicator, respectively. The Ru-complex current response indicates only the complementary sequence showing an obvious current signal in comparison to non-complementary and three or single point mismatched sequences. The fabricated biosensor possessed good selectivity and sensitivity for complementary probe, taxon: 32630 tumor necrosis factor (TNF). The linear dynamic range, sensitivity and detection limit of the proposed biosensor were 4 × 10−10 M to 1 × 10−8 M, 34.32 nA nM−1 and 6.8 × 10−11 M, respectively. Excellent reproducibility and stability, quite simple and inexpensive preparation are the other advantages of proposed biosensor.  相似文献   

18.
19.
Herein, a novel third-generation glucose biosensor based on unique hollow nanostructured Pt decorated multiwall carbon nanotubes (HPt-CNTs) composites was successfully constructed. The HPt-CNTs composites were successfully prepared and cast on the glassy carbon electrode (GCE) surface directly. With the help of electrostatic adsorption and covalent attachment, the negative l-cysteine (l-cys) and the positive poly(diallydimethylammonium) chloride (PDDA) protected gold nanoparticles (PDDA-Au) were modified on the resulting electrode surface subsequently, which provided further immobilization of glucose oxidase (GOD). Exploitation of the unique properties of HPt-CNTs composites led to the achievement of direct electron transfer between the electrode and the redox active centers of GOD, and the electrode exhibited a pair of well-defined reversible redox peaks with a fast heterogeneous electron transfer rate. In particular, the detection limit (4 × 10−7 M) of this biosensor was significantly lower and the linear range (1.2 μM–8.4 mM) was much wider than similar carbon nanotubes (CNTs) and Pt-based glucose biosensors. The resulted biosensor also showed high sensitivity and freedom of interference from other co-existing electroactive species, indicating that our facile procedure of immobilizing GOD exhibited better response and had potential application for glucose analysis.  相似文献   

20.
An amperometric assay for the determination of inorganic phosphate (Pi) in urine has been developed without the need for sample preparation. A screen-printed carbon electrode modified with the electrocatalyst cobalt phthalocyanine (CoPC–SPCE) and covered with a cellulose acetate membrane (CAM) serves as the sensor. The sensor detects hydrogen peroxide (H2O2), which is produced as a result of the oxidative decarboxylation of pyruvate, catalyzed by pyruvate oxidase (PyOd), in the presence of Pi, oxygen, and cofactors. Following optimization of solution conditions, and in the presence of a urine sample, a linear range was found to exist between the rate of current increase and phosphate concentration over the range of 2.27 × 10−5 to 1.81 × 10−4 M, and the limit of detection was found to be 4.27 × 10−6 M. The assay was applied to the determination of phosphate ions in the urine of a normal subject, and the mean concentration in unspiked urine was found to be 3.40 × 10−5 M with a coefficient of variation of 8.0% (n = 5). The mean recovery of phosphate added to urine samples was 98.7% with a coefficient of variation of 5.5% (n = 3). To the authors’ knowledge, this is the first report of an amperometric assay for Pi that incorporates a CoPC–SPCE as the sensing device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号