首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We tested whether biventricular resynchronization explains contractile function changes with univentricular and biventricular pacing in heart failure patients with varying magnitudes of baseline biventricular asynchrony. Thirty patients (New York Hospital Association class > or = III, QRS duration > or =120 ms) were tested. Contractile function was measured by left ventricular maximum first derivative of pressure over time (dP/dtmax). Biventricular mechanical asynchrony was quantified by the normalized pressure-pressure (NPP) loop area formed by the cross-plot of right and left intraventricular pressure curves from each cardiac cycle. Any ventricular pacing increased dP/dtmax if it decreased baseline NPP loop area and almost always worsened dP/dtmax and asynchrony when baseline NPP loop area <0.3. The quantitative relationship between dP/dtmax and NPP loop area change depended on ventricular pacing site and timing relative to intrinsic activation. For similar NPP loop decreases, dP/dtmax increased 16% more with left and biventricular pacing compared with right ventricular pacing. In conclusion, right, left, or biventricular pacing can improve contractile function only in patients having sufficient baseline biventricular asynchrony. However, biventricular resynchronization is only one of the improvement mechanisms.  相似文献   

2.
The goal of the present study was to assess the effects of left ventricular (LV) pacing sites (apex vs. free wall) on radial synchrony and global LV performance in a canine model of contraction dyssynchrony. Ultrasound tissue Doppler imaging and hemodynamic (LV pressure-volume) data were collected in seven anesthetized, opened-chest dogs. Right atrial (RA) pacing served as the control, and contraction dyssynchrony was created by simultaneous RA and right ventricular (RV) pacing to induce a left bundle-branch block-like contraction pattern. Cardiac resynchronization therapy (CRT) was implemented by adding simultaneous LV pacing to the RV pacing mode at either the LV apex (CRTa) or free wall (CRTf). A new index of synchrony was developed via pair-wise cross-correlation analysis of tissue Doppler radial strain from six midmyocardial cross-sectional regions, with a value of 15 indicating perfect synchrony. Compared with RA pacing, RV pacing significantly decreased radial synchrony (11.1 +/- 0.8 vs. 4.8 +/- 1.2, P < 0.01) and global LV performance (cardiac output: 2.0 +/- 0.3 vs. 1.4 +/- 0.1 l/min and stroke work: 137 +/- 22 vs. 60 +/- 14 mJ, P < 0.05). Although both CRTa and CRTf significantly improved radial synchrony, only CRTa markedly improved global function (cardiac output: 2.1 +/- 0.2 l/min and stroke work: 113 +/- 13 mJ, P < 0.01 vs. RV pacing). Furthermore, CRTa decreased LV end-systolic volume compared with RV pacing without any change in LV end-systolic pressure, indicating an augmented global LV contractile state. Thus, LV apical pacing appears to be a superior pacing site in the context of CRT. The dissociation between changes in synchrony and global LV performance with CRTf suggests that regional analysis from a single plane may not be sufficient to adequately characterize contraction synchrony.  相似文献   

3.

Background

Echocardiography plays an integral role in the diagnosis of congestive heart failure including measurement of left heart pressure as well as mechanical dyssynchrony.

Methods

In this report we describe novel therapeutic uses of echo pulsed wave Doppler in atrioventricular pacemaker optimization in patients who had either not derived significant symptomatic benefit post biventricular pacemaker implantation or deteriorated after deriving initial benefit. In these patients atrioventricular optimization showed novel findings and improved cardiac output and symptoms.

Results

In 3 patients with Cheyne Stokes pattern of respiration echo Doppler showed worsening of mitral regurgitation during hyperpneac phase in one patient, marked E and A fusion in another patient and exaggerated ventricular interdependence in a third patient thus highlighting mechanisms of adverse effects of Cheyne Stokes respiration in patients with heart failure. All 3 patients required a very short atrioventricular delay programming for best cardiac output. In one patient with recurrent congestive heart failure post cardiac resynchronization, mitral inflow pulse wave Doppler showed no A wave until a sensed atrioventricular delay of 190 ms was reached and showed progressive improvement in mitral inflow pattern until an atrioventricular delay of 290 ms. In 2 patients atrioventricular delay as short as 50 ms was required to allow E and A separation and prevent diastolic mitral regurgitation. All patients developed marked improvement in congestive heart failure symptoms post echo-guided biv pacemaker optimization.

Conclusion

These findings highlight the value of echo-guided pacemaker optimization in symptomatic patients post cardiac resynchronization treatment.  相似文献   

4.
Cardiac resynchronization therapy is not commonly used in the early postoperative period in patients undergoing cardiac surgery who have left ventricular (LV) dysfunction and a history of heart failure. We performed a prospective randomized clinical trial to compare atrial synchronous right ventricular (DDD RV) and biventricular (DDD BIV) pacing within 72 hours after cardiac surgery in patients with an EF ≤35 %, a QRS interval longer than 120 msec and who had LV dyssynchrony detected by real-time three-dimensional echocardiography (RT3DE). Epicardial pacing was provided by a modified Medtronic INSYNC III pacemaker. An LV epicardial pacing lead was implanted on the latest activated segment of the LV based on RT3DE. The study included 18 patients with ischemic heart disease, with or without valvular heart disease (14 men, 4 women, average age 71 years). Patients undergoing DDD BIV pacing had a statistically significant greater CO and CI (CO 6.7±1.8 l/min, CI 3.4±0.7 l/min/m(2)) than patients undergoing DDD RV pacing (CO 5.5±1.4 l/min, CI 2.8±0.7 l/min/m(2)), p<0.001. DDD BIV pacing in the early postoperative period after cardiac surgery corrects LV dyssynchrony and has better hemodynamic results than DDD RV pacing.  相似文献   

5.
Approximately one third of patients treated with cardiac resynchronization therapy do not derive any detectable benefit. In these patients, acute invasive hemodynamic evaluation can be used for therapy optimization. This report describes the use of systematic invasive hemodynamic measurements for clinical decision making in a patient who experienced severe ventricular arrhythmias and clinical deterioration following a biventricular upgrade.  相似文献   

6.
Mechanical dyssynchrony is an important codeterminant of cardiac dysfunction in heart failure. Treatment, either medical, surgical, or by pacing, may improve cardiac function partly by improving mechanical synchrony. Consequently, the quantification of ventricular mechanical (dys)synchrony may have important diagnostic and prognostic value and may help to determine optimal therapy. Therefore, we introduced new indexes to quantify temporal and spatial aspects of mechanical dyssynchrony derived from online segmental conductance catheter signals obtained during diagnostic cardiac catheterization. To test the feasibility and usefulness of our approach, we determined cardiac function and left ventricular mechanical dyssynchrony by the conductance catheter in heart failure patients with intraventricular conduction delay (n = 12) and in patients with coronary artery disease (n = 6) and relatively preserved left ventricular function. The heart failure patients showed depressed systolic and diastolic function. However, the most marked hemodynamic differences between the groups were found for mechanical dyssynchrony, indicating a high sensitivity and specificity of the new indexes. Comparison of conductance catheter-derived indexes with septal-to-lateral dyssynchrony derived by tissue-Doppler velocity imaging showed highly significant correlations. The proposed indexes provide additional, new, and quantitative information on temporal and spatial aspects of mechanical dyssynchrony. They may refine diagnosis of cardiac dysfunction and evaluation of interventions, and ultimately help to select optimal therapy.  相似文献   

7.
Temporary sequential biventricular pacing (BiVP) is a promising treatment for postoperative cardiac dysfunction, but the mechanism for improvement in right ventricular (RV) dysfunction is not understood. In the present study, cardiac output (CO) was optimized by sequential BiVP in six anesthetized, open-chest pigs during control and acute RV pressure overload (RVPO). Ventricular contractility was assessed by the maximum rate of increase of ventricular pressure (dP/dt(max)). Mechanical interventricular synchrony was measured by the area of the normalized RV-left ventricular (LV) pressure diagram (A(PP)). Positive A(PP) indicates RV pressure preceding LV pressure, whereas zero indicates complete synchrony. In the control state, CO was maximized with nearly simultaneous stimulation of the RV and LV, which increased RV (P = 0.006) and LV dP/dt(max) (P = 0.002). During RVPO, CO was maximized with RV-first pacing, which increased RV dP/dt(max) (P = 0.007), but did not affect LV dP/dt(max), and decreased the left-to-right, end-diastolic pressure gradient (P = 0.023). Percent increase of RV dP/dt(max) was greater than LV dP/dt(max) (P = 0.014). There were no increases in end-diastolic pressure to account for increases in dP/dt(max). In control and RVPO, RV dP/dt(max) was linearly related to A(PP) (r = 0.779, P < 0.001). The relation of CO to A(PP) was curvilinear, with a peak in CO with positive A(PP) in the control state (P = 0.004) and with A(PP) approaching zero during RVPO (P = 0.001). These observations imply that, in our model, BiVP optimization improves CO by augmenting RV contractility. This is mediated by changes in mechanical interventricular synchrony. Afterload increases during RVPO exaggerate this effect, making CO critically dependent on simultaneous pressure generation in the RV and LV, with support of RV contractility by transmission of LV pressure across the interventricular septum.  相似文献   

8.
Cardiac resynchronization therapy has been most typically achieved by biventricular stimulation. However, left ventricular (LV) free-wall pacing appears equally effective in acute and chronic clinical studies. Recent data suggest electrical synchrony measured epicardially is not required to yield effective mechanical synchronization, whereas endocardial mapping data suggest synchrony (fusion with intrinsic conduction) is important. To better understand this disparity, we simultaneously mapped both endocardial and epicardial electrical activation during LV free-wall pacing at varying atrioventricular delays (AV delay 0-150 ms) in six normal dogs with the use of a 64-electrode LV endocardial basket and a 128-electrode epicardial sock. The transition from dyssynchronous LV-paced activation to synchronous RA-paced activation was studied by constructing activation time maps for both endo- and epicardial surfaces as a function of increasing AV delay. The AV delay at the transition from dyssynchronous to synchronous activation was defined as the transition delay (AVt). AVt was variable among experiments, in the range of 44-93 ms on the epicardium and 47-105 ms on the endocardium. Differences in endo- and epicardial AVt were smaller (-17 to +12 ms) and not significant on average (-5.0 +/- 5.2 ms). In no instance was the transition to synchrony complete on one surface without substantial concurrent transition on the other surface. We conclude that both epicardial and endocardial synchrony due to fusion of native with ventricular stimulation occur nearly concurrently. Assessment of electrical epicardial delay, as often used clinically during cardiac resynchronization therapy lead placement, should provide adequate assessment of stimulation delay for inner wall layers as well.  相似文献   

9.
This study explores the use of interventricular asynchrony (interVA) for optimizing cardiac resynchronization therapy (CRT), an idea emerging from a simple pathway model of conduction in the ventricles. Measurements were performed in six dogs with chronic left bundle branch block (LBBB) and in 29 patients of the Pacing Therapies for Congestive Heart Failure (PATH-CHF)-I study. In the dogs, intraventricular asynchrony (intraVA) was determined using left ventricular (LV) endocardial activation maps. In dogs and patients, the maximum rate of rise of LV pressure (LV dP/dt(max)) and the pulse pressure (PP) and interVA [time delay between upslope of LV and right ventricular (RV) pressure curves] were measured during LV, RV, and biventricular (BiV) pacing with various atrioventricular (AV) delays. Measurements in the canine hearts supported the pathway model in that optimal resynchronization occurred at approximately 50% reduction of intraVA and at an interVA value halfway that during LBBB and LV pacing. In patients with significant hemodynamic response during pacing (n = 22), intrinsic interVA and interVA at peak improvement (interVA(p)) varied widely between patients (from -83 to -15 ms and from -42 to +31 ms, respectively). However, the model predicted individual interVA(p) accurately (SD of +/-6 ms and +/-12 ms for LV dP/dt(max) and PP, respectively). At equal interVA, LV and BiV pacing produced equal hemodynamic response, but in 11 of 22 responders, BiV pacing reduced interVA insufficiently to reach the maximum hemodynamic response. LV pacing at short AV delay proved to result in better hemodynamics than predicted by the model, indicating that additional factors determine hemodynamics during LV preexcitation. Guided by a simple pathway model, interVA measurements accurately predict optimal hemodynamic performance in individual CRT patients.  相似文献   

10.
Right ventricular apical pacing may cause or worsen mitral regurgitation (MR). Potential mechanisms for this adverse sequelae include intraventricular dyssynchrony, altered papillary muscle function, pacing-induced cardiomyopathy with left ventricular dilation, and annular dilation. In contrast, biventricular (BiV) pacing may improve MR presumably by opposing the negative effects. Whether or not left ventricular lead location is important in treating mitral regurgitation in patients with pacemakers is unknown.We report a case of severe MR and left ventricular (LV) systolic failure in a patient with right ventricular pacing. Multiple potential etiologies for the worsening valve function were noted, and a stepwise iterative optimizing scheme that included basal lateral LV pacing improved mitral valve function and ameliorated heart failure symptoms.  相似文献   

11.
Cardiac resynchronization therapy device (CRT-P and CRT-D) implantation has increased tremendously with increasing operator experience, eligible patients and expansion of indications. Refinements in devices and algorithms now aid physicians to improve biventricular pacing and optimize CRT. We report a case in which an interesting device program was used to achieve biventricular pacing after repeated dislodgement of the atrial lead in a patient implanted with CRT-D.  相似文献   

12.
13.
We describe two cases in which a biventricular implantable cardioverter defibrillator for cardiac resynchronization therapy had to be placed on the right side due to unsuitability of the left subclavian vein. Endocardial implantation of a left ventricular lead through the coronary sinus was previously attempted but was unsuccessful. Implantation of the epicardial left ventricular pacing lead was performed through video-assisted thoracic surgery on the left side. The connector end of the left ventricular pacing lead was tunnelized through the anterior mediastinum into the right pleural space. The right-sided pocket was then opened. A tunnel was created from the pocket to the thoracic wall, and the pleural space was entered over the second rib. The lead was retrieved from the right pleural space and connected with the Cardiac resynchronization therapy-device (CRT-D). Both procedures and postoperative periods were uneventful. Intrathoracic left-to-right tunneling of an epicardial left ventricular lead by video-assisted thoracic surgery is feasible and safe. It provides an alternative to subcutaneous tunneling.  相似文献   

14.
Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS) heart failure may depend on the position of the LV lead in relation to the original activation pattern. In six nonfailing and six failing dogs, electrical DYSS was created by atrioventricular sequential pacing of the right ventricular apex. ENDO was compared with EPI biventricular pacing at five LV sites. In failing hearts, increases in the maximum rate of LV pressure change (dP/dt; r = 0.64), ejection fraction (r = 0.49), and minimum dP/dt (r = 0.51), relative to DYSS, were positively correlated (P < 0.01) with activation time at the LV pacing site during ENDO but not EPI pacing. ENDO pacing at sites with longer activation delays led to greater improvements in hemodynamic parameters and was associated with an overall reduction in electrical DYSS compared with EPI pacing (P < 0.05). These findings were qualitatively similar for nonfailing hearts. Improvement in hemodynamic function increased with activation time at the LV pacing site during ENDO but not EPI pacing. At the anterolateral wall, end-systolic transmural function was greater with local ENDO compared with EPI pacing. ENDO pacing and intrinsic activation delay may have important implications for management of DYSS heart failure.  相似文献   

15.

Background

Little is known about the effect of cardiac resynchronization therapy (CRT) on endo- and epicardial ventricular activation. Noninvasive imaging of cardiac electrophysiology (NICE) is a novel imaging tool for visualization of both epi- and endocardial ventricular electrical activation.

Methodology/Principal Findings

NICE was performed in ten patients with congestive heart failure (CHF) undergoing CRT and in ten patients without structural heart disease (control group). NICE is a fusion of data from high-resolution ECG mapping with a model of the patient''s individual cardiothoracic anatomy created from magnetic resonance imaging. Beat-to-beat endocardial and epicardial ventricular activation sequences were computed during native rhythm as well as during ventricular pacing using a bidomain theory-based heart model to solve the related inverse problem. During right ventricular (RV) pacing control patients showed a deterioration of the ventricular activation sequence similar to the intrinsic activation pattern of CHF patients. Left ventricular propagation velocities were significantly decreased in CHF patients as compared to the control group (1.6±0.4 versus 2.1±0.5 m/sec; p<0.05). CHF patients showed right-to-left septal activation with the latest activation epicardially in the lateral wall of the left ventricle. Biventricular pacing resulted in a resynchronization of the ventricular activation sequence and in a marked decrease of total LV activation duration as compared to intrinsic conduction and RV pacing (129±16 versus 157±28 and 173±25 ms; both p<0.05).

Conclusions/Significance

Endocardial and epicardial ventricular activation can be visualized noninvasively by NICE. Identification of individual ventricular activation properties may help identify responders to CRT and to further improve response to CRT by facilitating a patient-specific lead placement and device programming.  相似文献   

16.
BackgroundAtrial fibrillation (AF) is correlated with a poor biventricular pacing and inadequate response to cardiac resynchronization therapy (CRT). Biventricular pacing improvement can be achieved by conducting the atrioventricular junction ablation (AVJA). We aimed to investigate the benefit of AVJA for permanent AF and heart failure with reduced ejection fraction (HFrEF) patients receiving CRT.MethodsIn August 2020, a systematic review and meta-analysis study comparing CRT plus AVJA versus CRT for permanent AF and HFrEF patients was conducted. Relevant articles were identified through the electronic scientific database such as ClinicalTrials.gov, ProQuest, ScienceDirect, PubMed, and Cochrane. The pooled risk ratio (RR) and pooled mean difference (MD) were estimated.ResultsA total of 3199 patients from 14 cohort studies were involved in this study. Additional AVJA reduced cardiovascular mortality (RR = 0.75, 95% confidence interval [CI] = 0.61 to 0.93, P < 0.01) in permanent AF and HFrEF patients receiving CRT. Biventricular pacing rate was higher in CRT plus AVJA group (MD = 8.65%, 95% CI = 5.62 to 11.67, P < 0.01) than in CRT alone group. The reverse remodeling characterized by the reduction of left ventricular end-diastolic diameter (LVEDD) was greater in the CRT plus AVJA group (MD = ?2.11 mm, 95% CI = ?3.79 to ?0.42, P = 0.01).ConclusionIn permanent AF and HFrEF patients receiving CRT, AVJA effectively increased the biventricular pacing rate. Adequate biventricular pacing rate provided a better response to the CRT marked by the greater ventricular reverse remodeling and survival from cardiovascular mortality.  相似文献   

17.
The aim of this study was to evaluate the impact of a low-intensity training program on subclinical cardiac dysfunction and on dyssynchrony in moderately obese middle aged men. Ten obese and 14 age-matched normal-weight men (BMI: 33.6 ± 1.0 and 24.2 ± 0.5 kg/m(2)) were included. Obese men participated in an 8-week low-intensity training program without concomitant diet. Cardiac function and myocardial synchrony were assessed by echocardiography with tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). At baseline, obese men showed diastolic dysfunction on standard echocardiography, lower strain values (systolic strain: 15.9 ± 0.9 vs. 18.8 ± 0.3%, diastolic strain rate: 0.81 ± 0.09 vs. 1.05 ± 0.06 s(-1)), and significant intraventricular dyssynchrony (systolic: 13.3 ± 2.1 vs. 5.4 ± 2.1 ms, diastolic: 17.4 ± 3.2 vs. 9.1 ± 2.1 ms) (P < 0.05 vs. controls for all variables). Training improved aerobic fitness, decreased systolic blood pressure and heart rate, and reduced fat mass without weight loss. Diastolic function, strain values (systolic strain: 17.4 ± 0.9%, diastolic strain rate: 0.96 ± 0.12 s(-1)) and intraventricular dyssynchrony (systolic: 3.3 ± 1.7 ms, diastolic: 5.5 ± 3.4 ms) improved significantly after training (P < 0.05 vs. baseline values for all variables), reaching levels similar to those of normal-weight men. In conclusion, in obese men, a short and easy-to-perform low intensity training program restored diastolic function and cardiac synchrony and improved body composition without weight loss.  相似文献   

18.

Objective

The purpose of this study was to determine if anodal stimulation accounts for failure to benefit from cardiac resynchronization therapy (CRT) in some patients.

Background

Approximately 30-40% of patients with moderate to severe heart failure do not have symptomatic nor echocardiographic improvement in cardiac function following CRT. Modern CRT devices allow the option of programming left ventricular (LV) lead pacing as LV tip to right ventricular (RV) lead coil to potentially improve pacing thresholds. However, anodal stimulation can result in unintentional RV pacing (anode) instead of LV pacing (cathode).

Methods

Patients enrolled in our center''s CRT registry had an echocardiogram, 6-minute walk (6MW), and Minnesota Living with HF Questionnaire (MLHFQ) pre-implant and 6 months after CRT. Electrocardiograms (12 lead) during RV, LV, and biventricular (BiV) pacing were obtained at the end of the implant in 102 patients. Anodal stimulation was defined as LV pacing QRS morphology on EKG being identical to RV pacing or consistent with fusion with RV and LV electrode capture. LV end systolic volume (LVESV) was measured by echo biplane Simpson''s method and CRT responder was defined as 15% or greater reduction in LVESV.

Results

Of the 102 patients, 46 (45.1%) had the final LV lead pacing configuration programmed LV (tip or ring) to RV (coil or ring). 3 of the 46 subjects (6.5%) had EKG findings consistent with anodal stimulation, not corrected intraoperatively. All anodal stimulation patients were nonresponders to CRT by echo criteria (reduction in LVESV 13.3 ± 0.6%, increase in EF 5.0 ± 1.4%) compared to 46% responders for those without anodal stimulation, (change in LVESV 18.7 ± 25.6%, EF 7.6 ±10.9%). None of the anodal stimulation patients were responders for the 6 minute walk, compared to 32 of 66 (48%) of those without anodal stimulation.

Conclusion

Anodal stimulation is a potential underrecognized and ameliorable cause of poor response to CRT.  相似文献   

19.

Background

Dual chamber pacing improves functional status and reduces left ventricular outflow tract gradients in some, but not all patients with hypertrophic cardiomyopathy (HCM) by altering ventricular depolarisation. We investigated the use of biventricular (BIV) pacing in symptomatic patients with HCM.

Method

8 patients aged 58±7yrs with symptomatic HCM underwent BIV pacing. 5 patients had LVOT gradients >30mmHg. Ventricular electrodes were placed in the right ventricle (RV) and a branch of the coronary sinus. An atrial electrode was inserted to achieve BIV pacing with a short AV delay. The short-term effects of different pacing modalities were assessed using 2-D and Doppler echocardiography. Symptoms and exercise tolerance were assessed after a month of each pacing mode. Long-term follow up data was available for 5 years.

Results

Baseline EF was 67±14% and mean QRS duration was 132±26msecs. BIV pacing reduced QRS duration compared to RV pacing (129±46 vs. 205±54msecs, p<0.005). Five of the seven patients had baseline LVOT gradients (mean 67±25mmHg) that decreased to 41±15mm Hg with RV pacing (p<0.01) and 25±15mmHg with BIV pacing (p<0.005). Improvements in exercise time with active pacing occurred in six out of eight patients (75%), three (37.5%) had optimal exercise times with RV pacing and three with BIV pacing. Of the three patients with short term improvements with BIV pacing, one died 4 years post implant, one deteriorated with LV dilatation and one had the system explanted for infection.

Conclusion

BIV pacing showed short-term beneficial effects in some patients over and above RV pacing alone.  相似文献   

20.
Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Left bundle branch block ablation and repeated microembolizations were performed in dogs to induce electrical dysynchrony and to reduce LV ejection fraction to <35%. LVdP/dt(max) and other hemodynamic indexes were measured with a conductance catheter during LV epicardial, LV endocardial, biventricular (BiV) epicardial, BiV endocardial, and TriV pacing performed at three atrioventricular delays. LV endocardial pacing was obtained with a clinically available pacing system. The optimal site was defined as the site that increased dP/dt(max) by the largest percentage. Implantation of the endocardial lead was feasible in all canines (n = 8) without increased mitral regurgitation seen with transesophageal echocardiography and with full access to the different LV endocardial pacing sites. BiV endocardial pacing increased dP/dt(max) more than BiV epicardial and TriV pacing on average (P < 0.01) and at the optimal site (P < 0.01). There were no significant differences between BiV epicardial and TriV pacing. BiV endocardial pacing was superior to BiV epicardial and to TriV pacing in terms of acute hemodynamic response. Further investigation is needed to confirm the chronic benefit of this approach in humans.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号