首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

A clinical parameter commonly used to assess the neurological status of an individual is the tendon reflex response. However, the clinical method of evaluation often leads to subjective conclusions that may differ between examiners. Moreover, attempts to quantify the reflex response, especially in older age groups, have produced inconsistent results. This study aims to examine the influence of age on the magnitude of the patellar tendon reflex response.

Methodology/Principal Findings

This study was conducted using the motion analysis technique with the reflex responses measured in terms of knee angles. Forty healthy subjects were selected and categorized into three different age groups. Patellar reflexes were elicited from both the left and right patellar tendons of each subject at three different tapping angles and using the Jendrassik maneuver. The findings suggested that age has a significant effect on the magnitude of the reflex response. An angle of 45° may be the ideal tapping angle at which the reflex can be elicited to detect age-related differences in reflex response. The reflex responses were also not influenced by gender and were observed to be fairly symmetrical.

Conclusions/Significance

Neurologically normal individuals will experience an age-dependent decline in patellar reflex response.  相似文献   

2.
3.
4.
The photomotogram (P.M.G.) of the Achilles tendon reflex was studied in 26 patients with hypothermia (rectal temperature 33·3°C or less), 10 of whom also had myxoedema (serum protein bound iodine 2·8 μg/100 ml or less). No reflex could be elicited in eight (31%) of these patients, including three of those with myxoedema. Hypothermia increases both the contraction and the relaxation times of the reflex, the relaxation phase being particularly prolonged in those with myxoedema. In those patients from whom the reflex was elicited the ratio of the contraction time to the “half-relaxation time” in the P.M.G. was less than unity in six of the seven with myxoedema, and considerably greater than unity in eight of the 11 (73%) who were euthyroid. Thus, analysis of the Achilles tendon reflex P.M.G. correctly predicted the thyroid status in 14 of the 18 hypothermic patients in whom the Achilles tendon reflex was present (78%). The wider use of this rapid test of thyroid function would allow a more rational use of thyroid hormones in hypothermic patients and so lead to a better assessment of their value.  相似文献   

5.
目的 评价“中国医院住院患者体验和满意监测量表”的信度与效度,为改进量表、推广应用提供依据。方法 采用邮寄方式对出院患者进行问卷调查,使用SPSS数据分析软件,分别对量表的内部一致性、折半信度、内容效度及结构效度进行评价。结果 量表总体Cronbach’s ɑ系数为0.956,所包含6个维度的Cronbach’s ɑ系数均大于0.8。分半信度为0.971。各条目与量表总体的相关系数介于0.51~0.79之间。以所有条目为变量进行因子分析,共提取5个公因子,其累计贡献率为66.2%,各条目至少在其中一个公因子上负荷值大于0.4。结论 量表具有良好的信度和效度,适用于中国医院住院患者满意度的测评。  相似文献   

6.
7.
简单介绍如何利用SPSS软件对试卷的可信度和有效度进行分析,目的帮助广大教师掌握试卷的定量分析技术,提高自己的课堂考试试卷的质量,增强科学解释考试结果以及从考试结果中提取有用信息的能力。  相似文献   

8.

Background

Patellar tendinopathy (PT) is one of the most common knee disorders among athletes. Changes in morphology and elasticity of the painful tendon and how these relate to the self-perceived pain and dysfunction remain unclear.

Objectives

To compare the morphology and elastic properties of patellar tendons between athlete with and without unilateral PT and to examine its association with self-perceived pain and dysfunction.

Methods

In this cross-sectional study, 33 male athletes (20 healthy and 13 with unilateral PT) were enrolled. The morphology and elastic properties of the patellar tendon were assessed by the grey and elastography mode of supersonic shear imaging (SSI) technique while the intensity of pressure pain, self-perceived pain and dysfunction were quantified with a 10-lb force to the most painful site and the Victorian Institute of Sport Assessment-patella (VISA-P) questionnaire, respectively.

Results

In athletes with unilateral PT, the painful tendons had higher shear elastic modulus (SEM) and larger tendon than the non-painful side (p<0.05) or the dominant side of the healthy athletes (p<0.05). Significant correlations were found between tendon SEM ratio (SEM of painful over non-painful tendon) and the intensity of pressure pain (rho  = 0.62; p = 0.024), VISA-P scores (rho  = −0.61; p = 0.026), and the sub-scores of the VISA-P scores on going down stairs, lunge, single leg hopping and squatting (rho ranged from −0.63 to −0.67; p<0.05).

Conclusions

Athletes with unilateral PT had stiffer and larger tendon on the painful side than the non-painful side and the dominant side of healthy athletes. No significant differences on the patellar tendon morphology and elastic properties were detected between the dominant and non-dominant knees of the healthy control. The ratio of the SEM of painful to non-painful sides was associated with pain and dysfunction among athletes with unilateral PT.  相似文献   

9.
Abstract

Manual skill is now widely recognised as an important aspect of training in surgery. However, measurement of the skill of a surgeon has in the past been rather subjective in nature, relying on the judgement of experts in the analysis of videotapes. Objective measurements can be made by analysing the velocities of a surgeon's hands during a procedure. In particular, we have found that the number of movements made during a typical procedure will decrease as the surgeon's skill increases. Velocity traces display purposeful movements corrupted by uncorrelated noise from sources such as hand tremor and measurement artefacts. However, we have found that it is possible to filter the noise effectively. Furthermore, we have shown that the skill measurement obtained by counting movements is highly robust to over or under filtering.  相似文献   

10.
This study evaluated the validity and reliability of the BodyMetrix™ BX2000 A-mode ultrasound for estimating percent body fat (%BF) in athletes by comparing it to skinfolds and the BOD POD. Forty-five (22 males, 23 females) National Collegiate Athletic Association (NCAA) Division-I athletes volunteered for this study. Subjects were measured once in the BOD POD then twice by two technicians for skinfolds and ultrasound. A one-way repeated-measures ANOVA revealed significant differences between body composition methods (F = 13.24, p < 0.01, η² = 0.24). This difference was further explained by a sex-specific effect such that the mean difference between ultrasound and BOD POD was large for females (~ 5% BF) but small for males (~ 1.5% BF). Linear regression using the %BF estimate from ultrasound to predict %BF from BOD POD resulted in an R2 = 0.849, SEE = 2.6% BF and a TE = 4.4% BF. The inter-rater intraclass correlation (ICC) for skinfold was 0.966 with a large 95% confidence interval (CI) of 0.328 to 0.991. The inter-rater ICC for ultrasound was 0.987 with a much smaller 95% CI of 0.976 to 0.993. Both skinfolds and ultrasound had test-retest ICCs ≥ 0.996. The BX2000 ultrasound device had excellent test-retest reliability, and its inter-rater reliability was superior to the skinfold method. The validity of this method is questionable, particularly for female athletes. However, due to its excellent reliability, coaches and trainers should consider this portable and easy to use A-mode ultrasound to assess body composition changes in athletes.  相似文献   

11.
A set of procedures is offered for assessing interraler reliability and certain aspects of validity of codes in cross-cultural studies. The method assumes that at least two independent raters have coded more than one trait. Each trait coded by one rater is correlated with each trait coded by a second, and all the codings by a single rater are intercorrelated with each other. The results are presented in a multitrait-multi-rater matrix. From this matrix it is possible to determine the interrater reliability and discriminant validity of trails in addition to a higher order concept based on pairs of traits.  相似文献   

12.

Objective

To evaluate the psychometric properties and clinical utility of Chinese Multidimensional Health Assessment Questionnaire (MDHAQ-C) in patients with rheumatoid arthritis (RA) in China.

Methods

162 RA patients were recruited in the evaluation process. The reliability of the questionnaire was tested by internal consistency and item analysis. Convergent validity was assessed by correlations of MDHAQ-C with Health Assessment Questionnaire (HAQ), the 36-item Short-Form Health Survey (SF-36) and the Hospital anxiety and depression scales (HAD). Discriminant validity was tested in groups of patients with varied disease activities and functional classes. To evaluate the clinical values, correlations were calculated between MDHAQ-C and indices of clinical relevance and disease activity. Agreement with the Disease Activity Score (DAS28) and Clinical Disease Activity Index (CDAI) was estimated.

Results

The Cronbach''s alpha was 0.944 in the Function scale (FN) and 0.768 in the scale of psychological status (PS). The item analysis indicated all the items of FN and PS are correlated at an acceptable level. MDHAQ-C correlated with the questionnaires significantly in most scales and scores of scales differed significantly in groups of different disease activity and functional status. MDHAQ-C has moderate to high correlation with most clinical indices and high correlation with a spearman coefficient of 0.701 for DAS 28 and 0.843 for CDAI. The overall agreement of categories was satisfying.

Conclusion

MDHAQ-C is a reliable, valid instrument for functional measurement and a feasible, informative quantitative index for busy clinical settings in Chinese RA patients.  相似文献   

13.

Background

High aerobic fitness is consistently associated with a favorable metabolic risk profile in children. Direct measurement of peak oxygen consumption (VO2peak) is often not feasible, thus indirect tests such as the Andersen test are required in many settings. The present study seeks to determine the reliability and validity of the Andersen test in 10-year-old children.

Methods

A total of 118 10-year-old children (67 boys and 51 girls) were recruited from one school and performed four VO2peak tests over three weeks: three Andersen tests (indirect) and one continuous progressive treadmill test (direct). Of these, 104 children provided valid data on all Andersen tests and 103 children also provided valid data on the direct treadmill test. Reliability and validity were assessed using Bland Altman plots and linear regression analysis.

Results

Bias (mean change) and random error (limits of agreement) were 26.7±125.2 m for test 2 vs. test 1 (p<.001 for mean difference) and 3.9±88.8 m for test 3 vs. test 2 (p = .514 for mean difference). The equation to estimate VO2peak suggested by Andersen et al. (2008) showed a poor fit in the present sample; thus, we suggest a new equation: VO2peak = 23.262+0.050*Andersen distance –3.858*gender –0.376*body weight (R2 = 0.61, standard error of the estimate = 5.69, p<.001, boys = 0, girls = 1).

Conclusions

The Andersen test provided reliable and valid data on a group level. However, a substantial degree of individual variability was found for estimates of VO2peak. Researchers should be aware of the amount of noise in indirect tests that estimate aerobic fitness.  相似文献   

14.

Introduction

Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power.

Methods

30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change.

Results

Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79).

Conclusions

Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.  相似文献   

15.
While considerable knowledge has been gained through the use of established cognitive and motor assessment tools, there is a considerable interest and need for the development of a battery of reliable and validated assessment tools that provide real-time and remote analysis of cognitive and motor function in the elderly. Smartphones appear to be an obvious choice for the development of these “next-generation” assessment tools for geriatric research, although to date no studies have reported on the use of smartphone-based applications for the study of cognition in the elderly. The primary focus of the current study was to assess the feasibility, reliability, and validity of a smartphone-based application for the assessment of cognitive function in the elderly. A total of 57 non-demented elderly individuals were administered a newly developed smartphone application-based Color-Shape Test (CST) in order to determine its utility in measuring cognitive processing speed in the elderly. Validity of this novel cognitive task was assessed by correlating performance on the CST with scores on widely accepted assessments of cognitive function. Scores on the CST were significantly correlated with global cognition (Mini-Mental State Exam: r = 0.515, p<0.0001) and multiple measures of processing speed and attention (Digit Span: r = 0.427, p<0.0001; Trail Making Test: r = −0.651, p<0.00001; Digit Symbol Test: r = 0.508, p<0.0001). The CST was not correlated with naming and verbal fluency tasks (Boston Naming Test, Vegetable/Animal Naming) or memory tasks (Logical Memory Test). Test re-test reliability was observed to be significant (r = 0.726; p = 0.02). Together, these data are the first to demonstrate the feasibility, reliability, and validity of using a smartphone-based application for the purpose of assessing cognitive function in the elderly. The importance of these findings for the establishment of smartphone-based assessment batteries of cognitive and motor function in the elderly is discussed.  相似文献   

16.
17.
Objective: Implied in measures of binge eating is the assumption that individuals agree on what comprises a large amount of food. However, whether individuals estimate food amounts similarly or whether estimation of food amounts varies as a function of personal characteristics is unknown. The Food Amount Rating Scale (FARS) is a standardized set of stimuli for assessing individuals’ judgment of food amounts. Research Methods and Procedures: Two versions of the FARS were developed, and their psychometric properties were assessed. These versions are the same in all respects except that the rater is instructed to rate various food amounts for the average woman on Form W and for the average man on Form M. Results: Content validity was confirmed by 14 researchers and research assistants in the field of eating disorders. The FARS is a 24-item inventory with adequate test–retest reliability (Form W = 0.85; Form M = 0.87) and split–half reliability (Form W = 0.90; Form M = 0.89). Convergent validity is suggested by the finding that ratings for the average woman (Form W) were significantly higher than ratings for the average man (Form M). Discussion: The FARS is a psychometrically sound tool for use in basic research focused on identifying whether the subjective judgment of food amounts varies as a function of personal characteristics and in clinical research where it may be important to know how individuals judge food amounts.  相似文献   

18.
镍钛聚髌器治疗髌骨骨折的电测分析   总被引:13,自引:0,他引:13  
应用电阻测度应变技术,得到镍钛聚髌器这一记忆合金内固定器的应力-应变关系曲线,较为精确地测定了镍钛聚髌器动态聚合加压髌骨于解剖位的生物力学力值,结果表明:镍钛聚髌器可从9个方向产生向心聚合力,纵向为主,记忆加压力值为13.67Kg,侧向为辅,永加压力值为5.19Kg,并具有一定的耐疲劳性。本实验为临床使用及指导病人术后功能锻炼提供了科学的依据,并为研究动态记忆力学下的骨愈合机理提供了实验基础。  相似文献   

19.
Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号