首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
磁性氧化铁纳米颗粒在磁共振成像方面的应用,已经在全世界范围内得到了广泛的关注,相关研究也被各国科学家高度重视.目前,磁性氧化铁纳米颗粒正在从早期的基于被动识别的肝部磁共振造影,快速转向基于主动识别的磁共振分子影像应用.本文将围绕磁性氧化铁纳米颗粒的生物体内应用,着重介绍磁性纳米颗粒的制备及其在疾病诊断,尤其是在肿瘤早期...  相似文献   

2.

Object

To better understand the fate of islet isografts and allografts, we utilized a magnetic resonance (MR) imaging technique to monitor mouse islets labeled with a novel MR contrast agent, chitosan-coated superparamagnetic iron oxide (CSPIO) nanoparticles.

Materials and Methods

After being incubated with and without CSPIO (10 µg/ml), C57BL/6 mouse islets were examined under transmission electron microscope (TEM) and their insulin secretion was measured. Cytotoxicity was examined in α (αTC1) and β (NIT-1 and βTC) cell lines as well as islets. C57BL/6 mice were used as donors and inbred C57BL/6 and Balb/c mice were used as recipients of islet transplantation. Three hundred islets were transplanted under the left kidney capsule of each mouse and then MR was performed in the recipients periodically. At the end of study, the islet graft was removed for histology and TEM studies.

Results

After incubation of mouse islets with CSPIO (10 µg/mL), TEM showed CSPIO in endocytotic vesicles of α- and β-cells at 8 h. Incubation with CSPIO did not affect insulin secretion from islets and death rates of αTC1, NIT-1 and βTC cell lines as well as islets. After syngeneic and allogeneic transplantation, grafts of CSPIO-labeled islets were visualized on MR scans as persistent hypointense areas. At 8 weeks after syngeneic transplantation and 31 days after allogeneic transplantation, histology of CSPIO-labeled islet grafts showed colocalized insulin and iron staining in the same areas but the size of allografts decreased with time. TEM with elementary iron mapping demonstrated CSPIO distributed in the cytoplasm of islet cells, which maintained intact ultrastructure.

Conclusion

Our results indicate that after syngeneic and allogeneic transplantation, islets labeled with CSPIO nanoparticles can be effectively and safely imaged by MR.  相似文献   

3.
余正贤  俞海平  胡蝶  朱艳  王如建 《生物磁学》2013,(34):6797-6800
分子影像学是近年来分子生物学和影像学相结合而形成的新型交叉学科,磁共振分子成像技术是分子影像学的重要手段之一,为临床医学诊断提供重要依据。但是由于不同组织之间的弛豫时间相互重叠等问题,导致较小的病变难以显示,磁共振造影剂能提高对软组织的分辨率,其中超顺磁性氧化铁纳米探针作为近年来发展起来的一种新型磁共振分子造影剂。由于具有敏感性、安全性、大的比表面积、高稳定性、靶向性等优点,近年来已成为国内外研究的热点之一。本文就超顺磁性氧化铁纳米探针的增强原理、制备工艺及靶向作用做一综述,以期为该技术的应用与研究提供借鉴和启示。  相似文献   

4.
Comprised mainly of monocytes and tissue macrophages, the reticuloendothelial system (RES) plays two major roles in iron metabolism: it recycles iron from senescent red blood cells and it serves as a large storage depot for excess iron. Although iron recycling by the RES represents the largest pathway of iron efflux in the body, the precise mechanisms involved have remained elusive. However, studies characterizing the function and regulation of Nramp1, DMT1, HFE, FPN1, CD163, and hepcidin are rapidly expanding our knowledge of the molecular aspects of RE iron handling. This review summarizes fundamental physiological and biochemical aspects of iron metabolism in the RES and focuses on how recent studies have advanced our understanding of these areas. Also discussed are novel insights into the molecular mechanisms contributing to the abnormal RE iron metabolism characteristic of hereditary hemochromatosis and the anemia of chronic disease.  相似文献   

5.

Background

Gadolinium (Gd), with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA), or other derivatives (at 0.1 mmole/kg recommended dose), distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF), particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.

Methodology/Principal Findings

To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP) containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T1) relaxivity, r1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.

Conclusions/Significance

The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug-target definition in system biology profiling, increasing the margin of safety in treatment of cancers and other diseases.  相似文献   

6.

Purpose

To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion.

Material and Methods

This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion.

Results

Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%.

Conclusion

Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.  相似文献   

7.

Background

Iron oxide nanoparticles (IONs) are a promising nanoplatform for contrast-enhanced MRI. Recently, magnetic particle imaging (MPI) was introduced as a new imaging modality, which is able to directly visualize magnetic particles and could serve as a more sensitive and quantitative alternative to MRI. However, MPI requires magnetic particles with specific magnetic properties for optimal use. Current commercially available iron oxide formulations perform suboptimal in MPI, which is triggering research into optimized synthesis strategies. Most synthesis procedures aim at size control of iron oxide nanoparticles rather than control over the magnetic properties. In this study, we report on the synthesis, characterization and application of a novel ION platform for sensitive MPI and MRI.

Methods and Results

IONs were synthesized using a thermal-decomposition method and subsequently phase-transferred by encapsulation into lipidic micelles (ION-Micelles). Next, the material and magnetic properties of the ION-Micelles were analyzed. Most notably, vibrating sample magnetometry measurements showed that the effective magnetic core size of the IONs is 16 nm. In addition, magnetic particle spectrometry (MPS) measurements were performed. MPS is essentially zero-dimensional MPI and therefore allows to probe the potential of iron oxide formulations for MPI. ION-Micelles induced up to 200 times higher signal in MPS measurements than commercially available iron oxide formulations (Endorem, Resovist and Sinerem) and thus likely allow for significantly more sensitive MPI. In addition, the potential of the ION-Micelle platform for molecular MPI and MRI was showcased by MPS and MRI measurements of fibrin-binding peptide functionalized ION-Micelles (FibPep-ION-Micelles) bound to blood clots.

Conclusions

The presented data underlines the potential of the ION-Micelle nanoplatform for sensitive (molecular) MPI and warrants further investigation of the FibPep-ION-Micelle platform for in vivo, non-invasive imaging of fibrin in preclinical disease models of thrombus-related pathologies and atherosclerosis.  相似文献   

8.
Adequately selecting a therapeutic approach for bladder cancer depends on accurate grading and staging. Substantial inaccuracy of clinical staging with bimanual examination, cystoscopy, and transurethral resection of bladder tumor has facilitated the increasing utility of magnetic resonance imaging to evaluate bladder cancer. Diffusion-weighted imaging (DWI) is a noninvasive functional magnetic resonance imaging technique. The high tissue contrast between cancers and surrounding tissues on DWI is derived from the difference of water molecules motion. DWI is potentially a useful tool for the detection, characterization, and staging of bladder cancers; it can also monitor posttreatment response and provide information on predicting tumor biophysical behaviors. Despite advancements in DWI techniques and the use of quantitative analysis to evaluate the apparent diffusion coefficient values, there are some inherent limitations in DWI interpretation related to relatively poor spatial resolution, lack of cancer specificity, and lack of standardized image acquisition protocols and data analysis procedures that restrict the application of DWI and reproducibility of apparent diffusion coefficient values. In addition, inadequate bladder distension, artifacts, thinness of bladder wall, cancerous mimickers of normal bladder wall and benign lesions, and variations in the manifestation of bladder cancer may interfere with diagnosis and monitoring of treatment. Recognition of these pitfalls and limitations can minimize their impact on image interpretation, and carefully applying the analyzed results and combining with pathologic grading and staging to clinical practice can contribute to the selection of an adequate treatment method to improve patient care.  相似文献   

9.
磁共振成像设备发展趋势   总被引:2,自引:0,他引:2  
本文主要叙述了磁共振设备的原理、构造、产品发展趋势。并对提高磁共振图像分辨的新技术,如Tim全景矩阵成像、自由浪潮技术、高清晰MRI技术和双梯度技术作了综述。  相似文献   

10.

Objective

To investigate the feasibility of gadolinium (Gd) contrast-enhanced magnetic resonance lymphangiography (MRL) in breast cancer patients within a typical clinical setting, and to establish a Gd-MRL protocol and identify potential MRL biomarkers for differentiating metastatic from non-metastatic lymph nodes.

Materials and Methods

32 patients with unilateral breast cancer were enrolled and divided into 4 groups of 8 patients. Groups I, II, and III received 1.0, 0.5, and 0.3 ml of intradermal contrast; group IV received two 0.5 ml doses of intradermal contrast. MRL images were acquired on a 3.0 T system and evaluated independently by two radiologists for the number and size of enhancing lymph nodes, lymph node contrast uptake kinetics, lymph vessel size, and contrast enhancement patterns within lymph nodes.

Results

Group III patients had a statistically significant decrease in the total number of enhancing axillary lymph nodes and lymphatic vessels compared to all other groups. While group IV patients had a statistically significant faster time to reach the maximum peak enhancement over group I and II (by 3 minutes), there was no other statistically significant difference between imaging results between groups I, II, and IV. 27 out of 128 lymphatic vessels (21%) showed dilatation, and all patients with dilated lymphatic vessels were pathologically proven to have metastases. Using the pattern of enhancement defects as the sole criterion for identifying metastatic lymph nodes during Gd-MRL interpretation, and using histopathology as the gold standard, the sensitivity and specificity were estimated to be 86% and 95%, respectively.

Conclusion

Gd-MRL can adequately depict the lymphatic system, can define sentinel lymph nodes, and has the potential to differentiate between metastatic and non-metastatic lymph nodes in breast cancer patients.  相似文献   

11.
血栓性疾病是临床常见疾病,涉及全身各脏器,其发生与血管损伤、血液成分变化及局部血流淤滞等改变有关.P-选择素作为血小板/内皮细胞活化标志及黏附受体,参与血栓形成起始过程,并是连接炎症与血栓的重要介质和靶分子.为此,进行了以P-选择素为靶标的分子磁共振成像(magnetic resonance imaging,MRI)在血栓早期诊断中的应用研究.利用自制的抗P-选择素单抗(PsL-EGFmAb),制备了具有P-选择素靶特异性的MR对比剂(Gd-DTPA)n-BSA-PsL- EGFmAb,并在体外MR成像基础上,进行了犬静脉血栓模型活体观察.结果显示,该对比剂可明显增强体外模拟血小板血栓和全血血栓的显像信号.进一步发现,相应于P-选择素在建模后即刻犬受损静脉血管内膜及形成的血栓部位表达,模型犬在损伤局部注射对比剂后30 min,MR成像即显示高于周围肌肉显影的血管信号,1 h可见附壁血栓增强信号,至3 h随血栓形成增大而持续强化,显示了与P-选择素表达一致的信号强化效果.另从股静脉损伤部位的远心端注射对比剂后30 min至1 h,也显示上述成像效果,2 h 至4 h血栓信号强度由明显上升渐见趋缓,延迟24 h信号强度减弱.此外,该对比剂对实验犬的生命体征及心、肺、肝、肾等理化指标均无明显影响.研究结果提示,研制的MR对比剂对P-选择素具有靶向特异性,可活体内早期定位显像及反映血栓形成状态,且对机体重要脏器功能无影响,这为早期诊断血栓性疾病提供了一种可行的方法.  相似文献   

12.
磁共振成像是诊断早期前列腺癌及评价分期最好的影像学技术之一,然而常规MRI-T2WI在诊断中存在较低的特异性缺陷.随着核磁技术的发展,对前列腺癌的诊断发展到从定性到定量、从形态到功能的变化,本文主要就近年来的磁共振功能成像技术在前列腺癌诊断中的研究进展作一论述.  相似文献   

13.

Purpose

To develop a diffusion-tensor-imaging (DTI) protocol that is sensitive to the complex diffusion and perfusion properties of the healthy and malignant pancreas tissues.

Materials and Methods

Twenty-eight healthy volunteers and nine patients with pancreatic-ductal-adenocacinoma (PDAC), were scanned at 3T with T2-weighted and DTI sequences. Healthy volunteers were also scanned with multi-b diffusion-weighted-imaging (DWI), whereas a standard clinical protocol complemented the PDAC patients’ scans. Image processing at pixel resolution yielded parametric maps of three directional diffusion coefficients λ1, λ2, λ3, apparent diffusion coefficient (ADC), and fractional anisotropy (FA), as well as a λ1-vector map, and a main diffusion-direction map.

Results

DTI measurements of healthy pancreatic tissue at b-values 0,500 s/mm2yielded: λ1 = (2.65±0.35)×10−3, λ2 = (1.87±0.22)×10−3, λ3 = (1.20±0.18)×10−3, ADC = (1.91±0.22)×10−3 (all in mm2/s units) and FA = 0.38±0.06. Using b-values of 100,500 s/mm2 led to a significant reduction in λ1, λ2, λ3 and ADC (p<.0001) and a significant increase (p<0.0001) in FA. The reduction in the diffusion coefficients suggested a contribution of a fast intra-voxel-incoherent-motion (IVIM) component at b≤100 s/mm2, which was confirmed by the multi-b DWI results. In PDACs, λ1, λ2, λ3 and ADC in both 0,500 s/mm2 and 100,500 s/mm2 b-values sets, as well as the reduction in these diffusion coefficients between the two sets, were significantly lower in comparison to the distal normal pancreatic tissue, suggesting higher cellularity and diminution of the fast-IVIM component in the cancer tissue.

Conclusion

DTI using two reference b-values 0 and 100 s/mm2 enabled characterization of the water diffusion and anisotropy of the healthy pancreas, taking into account a contribution of IVIM. The reduction in the diffusion coefficients of PDAC, as compared to normal pancreatic tissue, and the smaller change in these coefficients in PDAC when the reference b-value was modified from 0 to 100 s/mm2, helped identifying the presence of malignancy.  相似文献   

14.
目的:评估磁共振波谱成像(Proton Magnetic Resonance Spectroscopy,1H-MRS)联合磁共振扩散加权成像(Diffusion Weighted Imaging,DWI)在鉴别脑胶质瘤及孤立的脑转移瘤中的作用。方法:应用3.0T磁共振扫描仪,对临床手术确诊及组织病理学诊断证实的49例脑肿瘤患者(35例多形性胶质母细胞瘤,14例脑转移瘤)进行常规磁共振成像、磁共振波谱成像及磁共振扩散加权成像,并并对获得的数据进一步测量瘤内及瘤周区的代谢比、N-乙酰天门冬氨酸(NAA)、胆碱(Cho)、肌酸(Cr)值以及表观弥散系数(ADC值),分析两肿瘤组之间不同参数的统计学差异。此外,我们研究了感兴趣区域(ROI)的大小对肿瘤区域的病变扩散性能潜在影响。结果:胶质母细胞瘤瘤周N-乙酰天门冬氨酸(NAA)、肌酸(Cr),胆碱(Cho)/Cr,Cho/NAA和r CBV显著高于颅内转移瘤(P0.05);ADC值在两肿瘤组之间无显著差异(P0.05)。结论:在瘤周区1H-MRS有助于鉴别胶质母细胞瘤与单发的脑转移瘤。在瘤内扩散性的定量特性依赖ROI大小的设置。  相似文献   

15.
16.

Object

We sought to detect an acute soft tissue infection in rats by magnetic resonance imaging (MRI) using granulocytes, previously labeled with superparamagnetic particles of iron oxide (SPIO).

Materials and Methods

Parasternal infection was induced by subcutaneous inoculation of Staphylococcus aureus suspension in rats. Granulocytes isolated from isogenic donor rats were labeled with SPIO. Infected rats were imaged by MRI before, 6 and 12 hours after intravenous injection of SPIO-labeled or unlabeled granulocytes. MR findings were correlated with histological analysis by Prussian blue staining and with re-isolated SPIO-labeled granulocytes from the infectious area by magnetic cell separation.

Results

Susceptibility effects were present in infected sites on post-contrast T2*-weighted MR images in all animals of the experimental group. Regions of decreased signal intensity (SI) in MRI were detected at 6 hours after granulocyte administration and were more pronounced at 12 hours. SPIO-labeled granulocytes were identified by Prussian blue staining in the infected tissue and could be successfully re-isolated from the infected area by magnetic cell separation.

Conclusion

The application of SPIO-labeled granulocytes in MRI offers new perspectives in diagnostic specificity and sensitifity to detect early infectious processes.  相似文献   

17.
Endometriosis is defined as the presence of endometrial tissue outside the uterine, which may affect nearly 60% of women in reproductive age. Deep infiltrating endometriosis (DIE) defined as an endometriotic lesion penetrating into the retroperitoneal space or the wall of the pelvic organs to a depth of at least 5 mm represents the most diagnostic challenge. Herein, we reported the use of hyaluronic acid (HA)-modified magnetic iron oxide nanoparticles (HA-Fe3O4 NPs) for magnetic resonance (MR) imaging of endometriotic lesions in the rodent model. Sixteen endometriotic lesions were surgically induced in eight rats by autologous transplantation. Four weeks after lesion induction, three rats were scanned via MR imaging after tail vein injection of the HA-Fe3O4 NPs. Accordingly, the remaining five mice were sacrificed in the corresponding time points. The ectopic uterine tissues (EUTs) were confirmed by histological analysis. Quantification of Fe in the EUT was also performed by inductively coupled plasma-optical emission spectroscopy. Our results showed that by using the HA-Fe3O4 NPs, the EUTs were able to be visualized via T2-weighted MR imaging at 2 hours post injection, corroborating the Prussian blue staining results. The developed HA-Fe3O4 NPs could be used as negative contrast agents for sensitively detecting endometriosis in a mouse model and may be applied for future hyperthermia treatment of endometriosis.  相似文献   

18.

Objective

To generate high-resolution maps of the viscoelastic properties of human brain parenchyma for presurgical quantitative assessment in glioblastoma (GB).

Methods

Twenty-two GB patients underwent routine presurgical work-up supplemented by additional multifrequency magnetic resonance elastography. Two three-dimensional viscoelastic parameter maps, magnitude |G*|, and phase angle φ of the complex shear modulus were reconstructed by inversion of full wave field data in 2-mm isotropic resolution at seven harmonic drive frequencies ranging from 30 to 60 Hz.

Results

Mechanical brain maps confirmed that GB are composed of stiff and soft compartments, resulting in high intratumor heterogeneity. GB could be easily differentiated from healthy reference tissue by their reduced viscous behavior quantified by φ (0.37±0.08 vs. 0.58±0.07). |G*|, which in solids more relates to the material''s stiffness, was significantly reduced in GB with a mean value of 1.32±0.26 kPa compared to 1.54±0.27 kPa in healthy tissue (P = 0.001). However, some GB (5 of 22) showed increased stiffness.

Conclusion

GB are generally less viscous and softer than healthy brain parenchyma. Unrelated to the morphology-based contrast of standard magnetic resonance imaging, elastography provides an entirely new neuroradiological marker and contrast related to the biomechanical properties of tumors.  相似文献   

19.
Mapping of the human brain by means of functional magnetic resonance imaging (fMRI) is an emerging field in cognitive and clinical neuroscience. Current techniques to detect activated areas of the brain mostly proceed in two steps. First, conventional methods of correlation, regression, and time series analysis are used to assess activation by a separate, pixelwise comparison of the fMRI signal time courses to the reference function of a presented stimulus. Spatial aspects caused by correlations between neighboring pixels are considered in a separate second step, if at all. The aim of this article is to present hierarchical Bayesian approaches that allow one to simultaneously incorporate temporal and spatial dependencies between pixels directly in the model formulation. For reasons of computational feasibility, models have to be comparatively parsimonious, without oversimplifying. We introduce parametric and semiparametric spatial and spatiotemporal models that proved appropriate and illustrate their performance applied to visual fMRI data.  相似文献   

20.
目的:评估和比较高分辨率计算机断层成像(high resolution computer tomography,HRCT)与磁共振成像(magnetic resonance imaging,MRI)对中耳胆脂瘤的诊断价值。方法:回顾性分析临床初步诊断为中耳胆脂瘤患者55人(63耳)在术前5天内进行的16排HRCT和1.5T MRI诊断结果,以病理诊断为基础对HRCT和MRI的诊断结果进行对比研究,统计分析HRCT和MRI的灵敏度、特异度、阳性预期值、阴性预期值,以及Kappa检验两者之间的内在观察一致性。结果:63耳中,病理确诊为中耳胆脂瘤40耳。HRCT正确诊断30例,假阳性11例,假阴性10例,灵敏度、特异度、阳性预期值以及阴性预期值分别为75%、52.17%、73.17%、54.55%。MRI正确诊断37例,假阳性和假阴性各为3例,灵敏度、特异度、阳性预期值以及阴性预期值分别为92.5%、86.96%、75%和86.96%。HRCT与MRI诊断结果之间的内在观察一致性Kappa=0.274(P0.05)。剔除既往有手术史的10耳,只针对无手术史的53耳,HRCT与MRI诊断结果之间的内在观察一致性增高,吻合度一般,Kappa=0.462(P0.05)。结论:MRI的总体阳性检出率高于HRCT,尤其是对中耳胆脂瘤手术后复发的诊断;HRCT与MRI两者相结合对于中耳胆脂瘤的明确诊断具有互补作用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号