1.
A virus concentration method using a cation-coated filter was developed for large-volume freshwater applications. Poliovirus type 1 (LSc 2ab Sabin strain) inoculated into 40 ml of MilliQ (ultrapure) water was adsorbed effectively to a negatively charged filter (Millipore HA, 0.45- micro m pore size) coated with aluminum ions, 99% (range, 81 to 114%) of which were recovered by elution with 1.0 mM NaOH (pH 10.8) following an acid rinse with 0.5 mM H(2)SO(4) (pH 3.0). More than 80% poliovirus recovery yields were obtained from 500-ml, 1,000-ml, and 10-liter MilliQ water samples and from tap water samples. This method, followed by TaqMan PCR detection, was applied to determine the presence of noroviruses in tap water in Tokyo, Japan. In a 14-month survey, 4 (4.1%) and 7 (7.1%) of 98 tap water samples (100 to 532 liters) contained a detectable amount of noroviruses of genotype 1 and genotype 2, respectively. This method was proved to be useful for surveying the occurrence of enteric viruses, including noroviruses, in large volumes of freshwater.  相似文献   

2.
A virus concentration method using a cation-coated filter was developed for large-volume freshwater applications. Poliovirus type 1 (LSc 2ab Sabin strain) inoculated into 40 ml of MilliQ (ultrapure) water was adsorbed effectively to a negatively charged filter (Millipore HA, 0.45-μm pore size) coated with aluminum ions, 99% (range, 81 to 114%) of which were recovered by elution with 1.0 mM NaOH (pH 10.8) following an acid rinse with 0.5 mM H2SO4 (pH 3.0). More than 80% poliovirus recovery yields were obtained from 500-ml, 1,000-ml, and 10-liter MilliQ water samples and from tap water samples. This method, followed by TaqMan PCR detection, was applied to determine the presence of noroviruses in tap water in Tokyo, Japan. In a 14-month survey, 4 (4.1%) and 7 (7.1%) of 98 tap water samples (100 to 532 liters) contained a detectable amount of noroviruses of genotype 1 and genotype 2, respectively. This method was proved to be useful for surveying the occurrence of enteric viruses, including noroviruses, in large volumes of freshwater.  相似文献   

3.
The sensitivity of several microporous virus-adsorbent media for reliably detecting low levels of poliovirus from 380 and 1,900 liters of drinking water by use of the tentative standard method was investigated. The virus-adsorbent media tested were (i) nitrocellulose membrane filters, (ii) epoxy-fiber glass-asbestos filters, (iii) yarn-wound fiber glass depth filters, and (iv) epoxy-fiber glass filter tubes. Virus was adsorbed to the filter media at pH 3.5 and eluted with glycine buffer, pH 11.5. The results from 44 samples demonstrated that poliovirus was detected with a 95% reliability at mean virus input levels of 3 to 7 plaque-forming units/380 liters when 1,900 liters of water was sampled. At mean virus input levels of less than 1 to 2 plaque-forming units/380 liters, the detection reliability was 66% in 76 samples when 1,900 liters of water was sampled. No significant difference in virus detection sensitivity was observed among the various virus adsorbent media tested. Overall virus recovery efficiency ranged from 28 to 42%, with a grand average of 35%. Members of the coxsackievirus groups A and B, echovirus, and adenovirus were also detected when 380 and 1,900 liters of water were sampled. These experimental observations attest to the sensitivity of the tentative standard method for detecting low levels of virus in large volumes of drinking water.  相似文献   

4.
The sensitivity of several microporous virus-adsorbent media for reliably detecting low levels of poliovirus from 380 and 1,900 liters of drinking water by use of the tentative standard method was investigated. The virus-adsorbent media tested were (i) nitrocellulose membrane filters, (ii) epoxy-fiber glass-asbestos filters, (iii) yarn-wound fiber glass depth filters, and (iv) epoxy-fiber glass filter tubes. Virus was adsorbed to the filter media at pH 3.5 and eluted with glycine buffer, pH 11.5. The results from 44 samples demonstrated that poliovirus was detected with a 95% reliability at mean virus input levels of 3 to 7 plaque-forming units/380 liters when 1,900 liters of water was sampled. At mean virus input levels of less than 1 to 2 plaque-forming units/380 liters, the detection reliability was 66% in 76 samples when 1,900 liters of water was sampled. No significant difference in virus detection sensitivity was observed among the various virus adsorbent media tested. Overall virus recovery efficiency ranged from 28 to 42%, with a grand average of 35%. Members of the coxsackievirus groups A and B, echovirus, and adenovirus were also detected when 380 and 1,900 liters of water were sampled. These experimental observations attest to the sensitivity of the tentative standard method for detecting low levels of virus in large volumes of drinking water.  相似文献   

5.
To determine whether suspended solids interfere with enteric virus recovery from water by microporous filter methods, the effects of bentonite clay solids at a concentration of 10 nephelometric turbidity units on the recovery of poliovirus type 1 from seeded, activated carbon-treated, filtered tap water were studied. Volumes (500 ml) of virus-laden water at pH 5.5 or 7.5, with and without 50 mM MgCl2, were filtered through 47-mm-diameter, electropositive (Virosorb 1MDS) and electronegative (Filterite) filters that had been pretreated with Tween 80 to minimize direct virus adsorption to filter surfaces. Bentonite solids enhanced virus retention on both types of filters, even under conditions in which viruses were not solids associated. However, bentonite solids also interfered with elution of retained viruses when eluting with 0.3% beef extract-50 mM glycine (pH 9.5). Under some conditions, overall virus recoveries were lower from water with bentonite solids than from solids-free control water. The results of this study indicate that clay turbidity can interfere somewhat with virus recovery by current microporous filter methods.  相似文献   

6.
Methods are described for the efficient concentration of an enterovirus from large volumes of tap water, sewage, and seawater. Virus in acidified water (pH 3.5) in the presence of aluminum chloride was adsorbed to a 10-inch (ca. 25.4 cm) fiberglass depth cartridge and a 10-inch pleated epoxy-fiberglass filter in a series at flow rates of up to 37.8 liters (10 gallons) per min. Adsorbed viruses were eluted from the filters with glycine buffer (pH 10.5 to 11.5), and the eluate was reconcentrated by using a combination of aluminum flocculation followed by hydroextraction. With this procedure, poliovirus in large volumes of tap water, seawater, and sewage could be concentrated with an average efficiency of 52, 53, and 50%, respectively. It was demonstrated that this method is capable of detecting surface solid-associated viruses originating from sewage treatment plants. No difference in virus recovery between laboratory batch studies and a set-up with acid-salt injection was found. This unified scheme for the concentration of viruses has many advantages over previously described systems. These include: high operating flow rates, low weight and small size, effectiveness with a variety of waters with widely varying qualities, and filters with a high resistance to clogging.  相似文献   

7.
To determine whether suspended solids interfere with enteric virus recovery from water by microporous filter methods, the effects of bentonite clay solids at a concentration of 10 nephelometric turbidity units on the recovery of poliovirus type 1 from seeded, activated carbon-treated, filtered tap water were studied. Volumes (500 ml) of virus-laden water at pH 5.5 or 7.5, with and without 50 mM MgCl2, were filtered through 47-mm-diameter, electropositive (Virosorb 1MDS) and electronegative (Filterite) filters that had been pretreated with Tween 80 to minimize direct virus adsorption to filter surfaces. Bentonite solids enhanced virus retention on both types of filters, even under conditions in which viruses were not solids associated. However, bentonite solids also interfered with elution of retained viruses when eluting with 0.3% beef extract-50 mM glycine (pH 9.5). Under some conditions, overall virus recoveries were lower from water with bentonite solids than from solids-free control water. The results of this study indicate that clay turbidity can interfere somewhat with virus recovery by current microporous filter methods.  相似文献   

8.
Methods are described for the efficient concentration of an enterovirus from large volumes of tap water, sewage, and seawater. Virus in acidified water (pH 3.5) in the presence of aluminum chloride was adsorbed to a 10-inch (ca. 25.4 cm) fiberglass depth cartridge and a 10-inch pleated epoxy-fiberglass filter in a series at flow rates of up to 37.8 liters (10 gallons) per min. Adsorbed viruses were eluted from the filters with glycine buffer (pH 10.5 to 11.5), and the eluate was reconcentrated by using a combination of aluminum flocculation followed by hydroextraction. With this procedure, poliovirus in large volumes of tap water, seawater, and sewage could be concentrated with an average efficiency of 52, 53, and 50%, respectively. It was demonstrated that this method is capable of detecting surface solid-associated viruses originating from sewage treatment plants. No difference in virus recovery between laboratory batch studies and a set-up with acid-salt injection was found. This unified scheme for the concentration of viruses has many advantages over previously described systems. These include: high operating flow rates, low weight and small size, effectiveness with a variety of waters with widely varying qualities, and filters with a high resistance to clogging.  相似文献   

9.
A preliminary study was carried out on evaluating a flow-through gauze sampler for its efficiency in recovering virus from both fresh and seawater. An attenuated type 1 poliovirus was used as the working model. When tap water was sampled, the amounts of virus adsorbed by the gauze pads were very small, about 2% of the total number of virus particles flowing through the device. The virus adsorption and recovery increased to 15 to 19% when seawater was sampled. Addition of NaCl to tap water produced a much better effect on virus adsorption and recovery by this device, i.e., 47% of the total virus particles in each sample. The best viral elution from the pads was obtained by using buffer solution of pH 8.0 to 9.0 containing a small amount of animal serum. Repeated elutions from the pads were necessary to recover the most virus although the first eluate contained approximately 50% of the adsorbed virus. Further development of this device appears warranted, because of (i) the simplicity of the procedure, (ii) its capability of sampling large volume of water, (iii) the low cost of collecting samples, and (iv) the feasibility of obtaining a rough quantitative assessment of viral pollutants in water examined.  相似文献   

10.
Concentration of enteroviruses from estuarine water.   总被引:11,自引:10,他引:1       下载免费PDF全文
Pleated cartridge filters readily adsorb viruses in estuarine water at low pH containing aluminum chloride. Adsorbed viruses are efficiently recovered by treating filters with glycine buffer at high pH. By using these procedures, it was possible to recover approximately 70% of the poliovirus added to 400 liters of estuarine water in 3 liters of filter eluate. Reconcentration of virus in the filter eluate in small volumes that are convenient for viral assays was more difficult. Reconcentration methods described previously for eluates from filters that process tap water or treated wastewater were inadequate when applied to eluates from filters used to process estuarine water containing large amounts of organic compounds. Two methods were found to permit efficient concentration of virus in filter eluates in small volumes. In both methods, virus in 3 liters of filter eluate was adsorbed to aluminum hydroxide flocs and then recovered in approximately 150 ml of buffered fetal calf serum. Additional reductions in volume were achieved by ultrafiltration or hydroextraction. By using these procedures 60 to 80% of the virus in 3 liters of filter eluate could be recovered in a final volume of 10 to 40 ml.  相似文献   

11.
Pleated cartridge filters readily adsorb viruses in estuarine water at low pH containing aluminum chloride. Adsorbed viruses are efficiently recovered by treating filters with glycine buffer at high pH. By using these procedures, it was possible to recover approximately 70% of the poliovirus added to 400 liters of estuarine water in 3 liters of filter eluate. Reconcentration of virus in the filter eluate in small volumes that are convenient for viral assays was more difficult. Reconcentration methods described previously for eluates from filters that process tap water or treated wastewater were inadequate when applied to eluates from filters used to process estuarine water containing large amounts of organic compounds. Two methods were found to permit efficient concentration of virus in filter eluates in small volumes. In both methods, virus in 3 liters of filter eluate was adsorbed to aluminum hydroxide flocs and then recovered in approximately 150 ml of buffered fetal calf serum. Additional reductions in volume were achieved by ultrafiltration or hydroextraction. By using these procedures 60 to 80% of the virus in 3 liters of filter eluate could be recovered in a final volume of 10 to 40 ml.  相似文献   

12.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

13.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

14.
15.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

16.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

17.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

18.
As part of our studies on the ecology of human enteric viruses, an improved method for detection of rotaviruses in water was developed, and their presence in Galveston Bay was monitored. Samples (378 liters) of estuarine water adjusted to pH 3.5 and a final AlCl3 molarity of 0.001 were filtered through 25-cm pleated cartridge-type filters (Filterite Corp., Timonium, Md.) of 3.0- and 0.45-micron porosity. Adsorbed virus was eluted with 1 liter of 10% tryptose phosphate broth, pH 9.5. Primary eluates were reconcentrated to a final volume of 10 to 20 ml by a simple and rapid magnetic iron oxide adsorption and elution procedure. Two percent casein at pH 8.5 effectively eluted rotavirus from iron oxide. A total of 21 of 72 samples of water, suspended solids, fluffy sediments, and compact sediments collected in different seasons in Galveston Bay yielded rotaviruses. Recovery of rotaviruses varied from 119 to 1,000 PFU/378 liters of water, 1,200 PFU/1,000 g of compact sediment, 800 to 3,800 PFU/378 liters of fluffy sediment, and 1,800 to 4,980 PFU from suspended solids derived from 378 liters of water based on immunofluorescent foci counts on cover slip cultures of fetal monkey kidney cells.  相似文献   

19.
Current methods to concentrate viruses from large volumes of water are prone to inconsistent results and are costly and complex procedurally. Ultrafiltration can utilize size exclusion rather than adsorption and (or) elution to concentrate viruses and, therefore, may offer greater flexibility in developing methods that can provide more consistent recoveries among different viruses and widely varying water conditions. Two small scale ultrafiltration systems (hollow fiber and tangential flow) were tested with a virus suspended in 2 L of reagent grade, tap, ground, or surface water. Three model viruses were used (bacteriophages PP7 and T1 and poliovirus) to compare and characterize the recovery of viruses with the two ultrafiltration systems. Pretreatment of the ultrafilters with blocking agents and the use of elution agents can serve to prevent viral adsorption to the filter surface or to elute bound virus and keep viral agents suspended in the retentate. The use of a blocking and elution step concentrated viruses (>60% recovery) from widely varying water qualities, including surface water, such that a single method can be used to efficiently concentrate viruses from all of the water types tested. Both ultrafiltration systems appear to be able to efficiently recover viruses; however, the hollow fiber systems provided slightly better results in the 2-L volumes tested.  相似文献   

20.
Human viral contamination in drinking and recreational water may persist for extensive periods of time and cause a significant health risk concern. The aim of this study is to evaluate a viral recovery method using a new electropositive charged nanoalumina filter and to compare results with the widely used negatively charged HAWP filter by Millipore Inc. The recovery of infectious recombinant adenovirus type 5 (rAd5) was tested using the Fluorescence-Activated Cell Sorting (FACS) assay, in parallel with viral genomes recovery assay by quantitative PCR (qPCR). The mean infectivity recoveries were 82-91% by nanoalumina filters eluted with 3% beef extract (BE, pH6.0), and 78-90% by HAWP filters eluted with 3% BE (pH 9.0), respectively, from 1 L of environmental samples seeded with 1pfu/mL rAd5. The mean genome recoveries were 16-35% by nanoalumina filters eluted with BE (pH 6.0), and 29-66% by HAWP filters eluted with NaOH (pH 10.8) from different types of water, respectively. Water quality, concentration of viruses, filters, and elution buffers are factors that determine the viral recovery efficiencies. The nanoalumina filters also had higher filtration rates than HAWP filters for large volumes of environmental water samples (up to10 L), thus, have an advantage in concentrating infectious viruses from environments without pre-filtration, adjusting pH or adding multivalent cations.  相似文献   