Objectives

To evaluate the postoperative stability of osteoporotic distal radius fractures fixed with distal locking screws with different length.

Methods

A comminuted extra-articular dorsally unstable distal radius fracture, treated with volar locking plate system, was created. The 18 specimens were randomized into 3 groups based on distal locked screws with different length: Group A had unicortical screws with 50% length to the dorsal cortex. Group B had unicortical screws with 75% length to the dorsal cortex. Group C had bicortical screws. Axial compression and bending loads were imposed on the models before and after cycling testing as well as load to clinical and catastrophic failure.

Results

Minimum change in stiffness was observed before and after fatigue for all groups. The final stiffness to bending forces was statistically similar in all groups, but stiffness to axial compression was statistically significant different: Group A approached significance with respect to groups B and C (P = 0.017, 0.009), whereas stiffness in group B and C was statistically similar (P = 0.93). Load to clinical failure was significantly less for group A (456.54±78.59 N) compared with groups B (580.24±73.85 N) and C (591.07±38.40 N). Load to catastrophic failure was statistically similar between groups, but mean values for Group A were 18% less than means for Group C.

Conclusions

The volar locking plate system fixed with unicortical locking screws with at least 75% length not only produced early stability for osteoporotic distal radius fractures, but also avoided extensor tendon complications due to dorsal screw protrusion.  相似文献   

2.
目的:研究锁定钢板固定术后内侧柱的支撑能力与肱骨近端骨折患者预后的相关关系。方法:选取107例肱骨近端骨折患者作为研究对象,根据不同内侧柱支撑重建方式将所有患者分为四组,其中A组患者48例,均接受肱骨近端内侧骨皮质解剖复位以重建内侧柱支持;B组患者20例,均使用1枚支撑螺钉置入肱骨头内下方的软骨下骨,C组患者14例,均使用2枚或2枚以上支撑螺钉置入肱骨头内下方的软骨下骨;D组患者25例,均未进行肱骨近端内侧骨皮质解剖复位亦未使用锁定螺钉固定。比较各组患者术后Constant评分、VAS(visual analogue scale)评分、骨折愈合时间、肱骨头高度丟失值、肱骨头内翻角、并发症发生情况及二次手术率。结果:与无支撑重建组相比,骨皮质解剖复位组、单枚螺钉支撑重建组以及多枚螺钉支撑重建组的VAS评分、骨折愈合时间、肱骨头高度丟失值以及肱骨头内翻角均明显降低,而Constant评分明显升高,其中骨皮质解剖复位组的变化幅度最大多枚螺钉支撑重建组次之,单枚螺钉支撑重建组变化幅度最小,差异具有统计学意义(t=23.100,22.130,7.267,68.440,47.900,均P0.001);与无支撑重建组相比,骨皮质解剖复位组、单枚螺钉支撑重建组以及多枚螺钉支撑重建组的术后总并发症发生率和二次手术率均明显降低,其中骨皮质解剖复位组的降低幅度最大,单枚螺钉支撑重建组次之,多枚螺钉支撑重建组降低幅度最小差异具有统计学意义(X~2=12.938,11.904,P=0.005,0.008)。结论:锁骨钢板固定术后内侧柱的支撑能力与肱骨近端异型解剖钢板患者预后相关,内侧柱支撑能力的越高患者术后骨折愈合、肩关节恢复越佳,而并发症发生率以及二次手术率越低。  相似文献   

3.

Purpose

Operative treatment of unstable posterior wall fractures of acetabulum has been widely recommended. This laboratory study was undertaken to evaluate static fixation strength of three common fixation constructs: interfragmentary screws alone, in combination with conventional reconstruction plate, or locking reconstruction plate.

Methods

Six formalin-preserved cadaveric pelvises were used for this investigation. A posterior wall fracture was created along an arc of 40–90 degree about the acetabular rim. Three groups of different fixation constructs (two interfragmentary screws alone; two interfragmentary screws and a conventional reconstruction plate; two interfragmentary screws and a locking reconstruction) were compared. Pelvises were axial loaded with six cycles of 1500 N. Dislocation of superior and inferior fracture site was analysed with a multidirectional ultrasonic measuring system. Results: No statistically significant difference was found at each of the superior and inferior fracture sites between the three types of fixation. In each group, the vector dislocation at superior fracture site was significantly larger than inferior one.

Conclusions

All those three described fixation constructs can provide sufficient stability for posterior acetabular fractures and allow early mobilization under experimental conditions. Higher posterior acetabular fracture line, transecting the weight-bearing surface, may indicate a substantial increase in instability, and need more stable pattern of fixation.  相似文献   

4.

Introduction

Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0.

Methods

Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0). A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured.

Results

The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N).

Conclusions

The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.  相似文献   

5.

Background

Radial nerve palsy associated with fractures of the shaft of the humerus is the most common nerve lesion complicating fractures of long bones. However, the management of radial nerve injuries associated with humeral fractures is debatable. There was no consensus between observation and early exploration.

Methods and Findings

The PubMed, Embase, Cochrane Central Register of Controlled Trials, Google Scholar, CINAHL, International Bibliography of the Social Sciences, and Social Sciences Citation Index were searched. Two authors independently searched for relevant studies in any language from 1966 to Jan 2013. Thirty studies with 2952 humeral fractures participants were identified. Thirteen studies favored conservative strategy. No significant difference between early exploration and no exploration groups (OR, 1.03, 95% CI 0.61, 1.72; I2 = 0.0%, p = 0.918 n.s.). Three studies recommend early radial nerve exploration in patients with open fractures of humerus with radial nerve injury. Five studies proposed early exploration was performed in high-energy humeral shaft fractures with radial nerve injury.

Conclusions

The conservative strategy was a good choice for patients with low-energy closed fractures of humerus with radial nerve injury. We recommend early radial nerve exploration (within the first 2 weeks) in patients with open fractures or high-energy closed fractures of humerus with radial nerve injury.  相似文献   

6.

Objective

This biomechanical study compared the torsional strength and stiffness of a locking compression plate with all locking versus nonlocking screws and examined the effect of placing a locking unicortical or nonlocking bicortical screw nearest the fracture gap in a synthetic bone model.

Results

Synthetic bone models simulating a diaphyseal fracture without anatomic reduction were tested using four screw configurations: all bicortical locking (ABL), all bicortical nonlocking (ABN), a hybrid construct with a bicortical nonlocking screw nearest the fracture gap (BN), and a unicortical locking screw placed nearest the fracture gap (UL). Torsional stiffness, rotation and torque at failure were compared via ANOVA and post hoc pairwise comparisons (p < 0.05). ABN and BN had the highest stiffness (p < 0.01) with ABL greater than UL (p < 0.01). Rotation at failure was greatest for ABL (p < 0.01) with UL greater than ABN (p < 0.05). Unicortical locking screws nearest the fracture gap decreased stiffness, without significantly affecting torque or rotation at failure. Construct stiffness was found to exist in a very narrow range of 0.9–1.2 N m/deg with standard deviations of 0.1 N m/deg in all cases. The results of this study support the use of nonlocking screws in a hybrid construct to increase torsional stiffness.
  相似文献   

7.

Introduction

Treatment of femoral neck fractures in young adults may require total hip arthroplasty or hip hemiarthroplasty using a bipolar cup. The latter can, however, result in migration of the femoral head and poor long-term results.

Case presentation

We report a case of femoral head migration after hemiarthroplasty performed for femoral neck fracture that had occurred 22 years earlier, when the patient (a Japanese man) was 20 years old. He experienced peri-prosthetic fracture of the femur, subsequent migration of the prosthesis, and a massive bone defect of the pelvic side acetabular roof. After bone union of the femoral shaft fracture, the patient was referred to our hospital for reconstruction of the acetabular roof. Intra-operatively, we placed two alloimplants of bone from around the transplanted femoral head into the weight-bearing region of the acetabular roof using an impaction bone graft method. We then implanted an acetabular roof reinforcement plate and a cemented polyethylene cup in the position of the original acetabular cup. Eighteen months post-operatively, X-rays showed union of the transplanted bone.

Conclusions

Treatment of femoral neck fractures in young adults is usually accomplished by osteosynthesis, but it may be complicated by femoral head avascular necrosis or by infection or osteomyelitis. In such cases, once an infection has subsided, either hip hemiarthroplasty using a bipolar cup or total hip arthroplasty may be required. However, if the acetabular side articular cartilage is damaged, a bipolar cup should not be used. Total hip arthroplasty should be performed to prevent migration of the implant.  相似文献   

8.
熊春龙  李永清  刘晓英 《蛇志》2016,(3):309-310
目的比较肱骨近端加压锁定钢板与传统钢板治疗肱骨近端骨折的临床治疗效果。方法选取我院2014年1月~2015年1月骨外科门诊收治的肱骨近端骨折患者60例,随机分为治疗组和对照组各30例。治疗组采用肱骨近端加压锁定钢板治疗,对照组采用传统钢板治疗,比较两组的Neer功能评分、骨折愈合时间、并发症发生情况。结果两组患者Neer功能评分与治疗前比较均有明显提高,治疗组提高水平明显优于对照组;而且治疗组骨折愈合时间、并发症发生情况均低于对照组,两组比较差异具有统计学意义(P0.05)。结论肱骨近端加压锁定钢板相比传统钢板治疗肱骨近端骨折的临床疗效更优,促进了患者的骨折愈合速度,降低了并发症发生率,具有临床推广和应用价值。  相似文献   

9.
The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding.  相似文献   

10.

Objectives

To determine the predictive value and sensitivity of demographic features and injuries (indicators) for maltreatment-related codes in hospital discharge records of children admitted with a head or neck injury or fracture.

Methods

Study design: Population-based, cross sectional study. Setting: NHS hospitals in England. Subjects: Children under five years old admitted acutely to hospital with head or neck injury or fracture. Data source: Hospital Episodes Statistics, 1997 to 2009. Main outcome measure: Maltreatment-related injury admissions, defined by ICD10 codes, were used to calculate for each indicator (demographic feature and/or type of injury): i) the predictive value (proportion of injury admissions that were maltreatment-related); ii) sensitivity (proportion of all maltreatment-related injury admissions with the indicator).

Results

Of 260,294 childhood admissions for fracture or head or neck injury, 3.2% (8,337) were maltreatment-related. With increasing age of the child, the predictive value for maltreatment-related injury declined but sensitivity increased. Half of the maltreatment-related admissions occurred in children older than one year, and 63% occurred in children with head injuries without fractures or intracranial injury.

Conclusions

Highly predictive injuries accounted for very few maltreatment-related admissions. Protocols that focus on high-risk injuries may miss the majority of maltreated children.  相似文献   

11.

Background

Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae.

Methods

Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively). Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests.

Results

No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws.

Conclusions

Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.  相似文献   

12.
At present biomechanical testing of fracture plating strategies is conducted using animal or cadaveric whole bone models. This may introduce experimental error into these studies. This communication summarises the design and validation of a novel bone and fibre-reinforced plastic construct conceived to minimise intra-experimental error. A tubular surrogate humerus was produced with dimension and strength matched to that of the human humerus. Bone inserts placed into the wall of the tube allow for the fixation of the plates with bone screws. Three-point bending tests of the flexural rigidity of the surrogate humerus (EI=100.1 (SD 6.0)Nm(2)) showed it to be comparable to the human humerus. Further, pull-out tests of the screws showed that the bone slots adequately mimicked the whole bone scenario. This testing construct will be used for a comparative study of humeral plating techniques.  相似文献   

13.

Introduction

Sonic Hedgehog (SHH) is a new signalling pathway in bone repair. Evidence exist that SHH pathway plays a significant role in vasculogenesis and limb development during embryogenesis. Some in vitro and animal studies has already proven its potential for bone regeneration. However, no data on the role of SHH in the human fracture healing have been published so far.

Methods

Seventy-five patients with long bone fractures were included into the study and divided in 2 groups. First group contained 69 patients with normal fracture healing. Four patients with impaired fracture healing formed the second group. 34 volunteers donated blood samples as control. Serum samples were collected over a period of 1 year following a standardized time schedule. In addition, SHH levels were measured in fracture haematoma and serum of 16 patients with bone fractures.

Results

Fracture haematoma and patients serum both contained lower SHH concentrations compared to control serum. The comparison between the patients'' serum SHH level and the control serum revealed lower levels for the patients at all measurement time points. Significantly lower concentrations were observed at weeks 1 and 2 after fracture. SHH levels were slightly decreased in patients with impaired fracture healing without statistical significance.

Conclusion

This is the first study to report local and systemic concentration of SHH in human fracture healing and SHH serum levels in healthy adults. A significant reduction of the SHH levels during the inflammatory phase of fracture healing was found. SHH concentrations in fracture haematoma and serum were lower than the concentration in control serum for the rest of the healing period. Our findings indicate that there is no relevant involvement of SHH in human fracture healing. Fracture repair process seem to reduce the SHH level in human. Further studies are definitely needed to clarify the underlying mechanisms.  相似文献   

14.

Objective

The aim of our study was to elucidate the pathophysiology of systemic sclerosis-related osteoporosis and the prevalence of vertebral fragility fracture in postmenopausal women with systemic sclerosis (SSc).

Methodology

Fifty-four postmenopausal women with scleroderma and 54 postmenopausal controls matched for age, BMI, and smoking habits were studied. BMD was measured by dual energy-x-ray absorptiometry at spine and femur, and by ultrasonography at calcaneus The markers of bone turnover included serum osteocalcin and urinary deoxypyridinoline. All subjects had a spine X-ray to ascertain the presence of vertebral fractures.

Results

bone mineral density at lumbar spine (BMD 0.78±0.08 vs 0.88±0.07; p<0,001), femoral neck (BMD: 0.56±0.04 vs 0.72±0.07; p<0,001) and total femur (BMD: 0.57±0.04 vs 0.71±0.06; p<0,001) and ultrasound parameter at calcaneus (SI: 80.10±5.10 vs 94.80±6.10 p<0,001) were significantly lower in scleroderma compared with controls; bone turnover markers and parathyroid hormone level were significantly higher in scleroderma compared with controls, while serum of 25(OH)D3 was significantly lower. In scleroderma group the serum levels of 25(OH)D3 significantly correlated with PTH levels, BMD, stiffness index and bone turnover markers. One or more moderate or severe vertebral fractures were found in 13 patients with scleroderma, wherease in control group only one patient had a mild vertebral fracture.

Conclusion

Our data shows, for the first time, that vertebral fractures are frequent in subjects with scleroderma, and suggest that lower levels of 25(OH)D3 may play a role in the risk of osteoporosis and vertebral fractures.  相似文献   

15.

Objective

Reduced bone mineral density (BMD), assessed by Dual Energy X-ray absorptiometry (DXA), is a well-known risk factor for fragility fracture. A large proportion of patients with fracture have only slightly reduced BMD. Assessment of other bone structure features than BMD may improve identification of individuals at increased fracture risk. Digital X-ray radiogrammetry (DXR), which is a feasible tool for measurement of metacarpal cortical bone density, also gives an estimate of cortical bone porosity. Our primary aim was to explore the association between cortical porosity in the hand assessed by DXR and distal radius fracture.

Methods

This case-control study included 123 women >50 years with distal radius fracture, and 170 controls. DXR was used to measure metacarpal BMD (DXR-BMD), cortical porosity (DXR-porosity), thickness (DXR-CT) and bone width (DXR-W) of the hand. Femoral neck BMD was measured by DXA.

Results

The fracture group had a statistically significant lower DXR-BMD (0.492 vs. 0.524 g/cm2 p<0.001), higher cortical DXR-porosity (0.01256 vs. 0.01093, p<0.001), less DXR-CT (0.148 vs. 0.161cm, p<0.001) and lower femoral neck DXA-BMD (0.789 vs. 0.844 g/cm2, p = 0.001) than the controls. In logistic regression analysis adjusted for age, a significant association with distal radius fracture (OR, 95% CI) was found for body mass index (0.930, 0.880–0.983), DXA-BMD (0.996, 0.995–0.999), DXR-BMD (0.990, 0.985–0.998), DXR-porosity (1.468, 1.278–1.687) and DXR-CT (0.997, 0.996–0.999). In an adjusted model, DXR-porosity remained the only variable associated with distal radius fracture (1.415, 1.194–1.677).

Conclusion

DXR derived porosity is associated with fracture at distal radius and might be a sensitive marker for skeletal fragility.  相似文献   

16.
In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no "gold standard" treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 ± 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 ± 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p ≥ 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 ± 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic "spiral" pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture.  相似文献   

17.

Background

Hip fractures are a major public health burden. In industrialized countries about 20% of all femoral fractures occur in care dependent persons living in nursing care and assisted living facilities. Preventive strategies for these groups are needed as the access to medical services differs from independent home dwelling older persons at risk of osteoporotic fractures. It was the objective of the study to evaluate the effect of a fall and fracture prevention program on the incidence of femoral fracture in nursing homes in Bavaria, Germany.

Methods

In a translational intervention study a fall prevention program was introduced in 256 nursing homes with 13,653 residents. The control group consisted of 893 nursing homes with 31,668 residents. The intervention consisted of staff education on fall and fracture prevention strategies, progressive strength and balance training, and on institutional advice on environmental adaptations. Incident femoral fractures served as outcome measure.

Results

In the years before the intervention risk of a femoral fracture did not differ between the intervention group (IG) and control group (CG). During the one-year intervention period femoral fracture rates were 33.6 (IG) and 41.0/1000 person years (CG), respectively. The adjusted relative risk of a femoral fracture was 0.82 (95% CI 0.72-0.93) in residents exposed to the fall and fracture prevention program compared to residents from CG.

Conclusions

The state-wide dissemination of a multi-factorial fall and fracture prevention program was able to reduce femoral fractures in residents of nursing homes.  相似文献   

18.

Background

Avascular necrosis (AVN) refers to the death of osteocytes and osteoblasts. Sites such as the femoral head, the head of the humerus and the mandibula with restricted access to local blood supply are particularly vulnerable to osteonecrosis.A combination of several factors is responsible for ischaemia and is associated with AVN: corticosteroids, alcohol abuse, Cushing''s syndrome, SLE, systemic vasculitis, RA, scleroderma, haemoglobinopathies, radiotherapy. Management is based on proper diagnosis and treatment – conservative, pharmacological or surgical.Radiotherapy has become an integral part of the therapeutic programme of cancer patients. However, early and late after-effects of irradiation still constitute a significant issue in clinical practice.

Aim

The aim of this report is to present two cases of acetabular protrusion and femoral head deformities after a therapeutic pelvic irradiation and draw physicians’ attention to that clinical problem which continues to be underestimated.

Materials and methods

This report documents two cases of acetabular protrusion and femoral head deformities after a therapeutic pelvic radiation.

Results

Avascular necrosis (AVN) constitutes a severe and challenging long-term complication in radiation oncology.

Conclusion

It is necessary to take into account bone structures among organ at risk (OAR) involved in irradiation fields. The detailed analysis of the dose distribution and the use of collimators allow to decrease the total dose to OAR.An adequate management, early diagnosis and prompt, proper treatment may protect patients from long-term morbidities.  相似文献   

19.

Introduction

The prevention of fragility fractures in patients with sarcoidosis is a serious concern and the potential risk of hypercalcemia limits vitamin D and calcium supplementation. The objective of this study was to evaluate the risk factors for low bone mineral density (BMD) and fractures in sarcoidosis. In particular, we aimed to determine the link among bone fragility and calcium and vitamin D metabolism in this population.

Methods

We performed a cross-sectional analysis on 142 consecutive patients with histologically proven sarcoidosis. BMD and prevalence of vertebral fractures on X-rays were assessed and the association with potential risk factors was studied by regression analysis.

Results

Fragility fractures occurred in 23.5% of patients, despite a normal mean BMD in the study population. In a multivariate analysis, low dietary calcium, fracture, age, gender and menopause were associated with increased risk of low BMD. Low dietary calcium, high current corticosteroid dose and low creatinine clearance were associated with increased risk of fracture. Serum 25(OH)D between 10 and 20 ng/ml was significantly associated with higher BMD. Conversely, values greater than 20 ng/ml were associated with increased risk of fracture. Serum 25(OH)D level was inversely correlated with disease activity. Of note, vitamin D supplements increased serum 25(OH)D in a dose-dependent manner but had no effect on serum calcium level.

Conclusions

Sarcoidosis patients have a high risk of fracture despite not having a lowered BMD suggesting that other independent factors are involved. Current corticosteroid dose, low dietary calcium and serum 25(OH)D levels are associated with bone fragility. In sarcoidosis, calcium and vitamin D supplementation might be warranted, but desirable 25(OH)D serum levels might be lower than those advised for the general population.  相似文献   

20.
Hendrick OM  Ide JS  Luo X  Li CS 《PloS one》2010,5(10):e13155

Background

Conflict detection and subsequent behavioral adjustment are critical to daily life, and how this process is controlled has been increasingly of interest. A medial cortical region which includes the anterior cingulate cortex (ACC) has been theorized to act as a conflict detector that can direct prefrontal activity for behavioral adjustments. This conflict monitoring hypothesis was supported by many imaging studies of the Stroop task, with a focus on non-error processes. Here we sought to examine whether this circuit could be generalized to the stop signal task (SST), another behavioral paradigm widely used to study cognitive control. In particular, with a procedure to elicit errors in the SST, we examined whether error and non-error control were mediated by the same pathways.

Methodology/Principal Findings

In functional magnetic resonance imaging of 60 healthy adults, we demonstrated that the medial cortical activity during stop success (SS) as compared to go success (G) trials is correlated with increased prefrontal activity in post-stop SS as compared to post-go SS trials, though this correlation was not specific to the medial cortical region. Furthermore, thalamic and insular rather than medial cortical activation during stop error (SE) as compared to G trials correlated with increased prefrontal activity in post-stop SS as compared to post-go SS trials.

Conclusions/Significance

Taken together, these new findings challenge a specific role of the ACC and support distinct pathways for error and non-error conflict processing in cognitive control.  相似文献   